Manual Ensacadoras
Manual Ensacadoras
AF-50K-103A
Operating instruction
1
directory
Chapter 1 An overview of the ...................................................................... 6
2
6.7 Calibration scale interface description ......................................... 28
3
Chapter 11 Unpack and inspect ................................................................ 48
4
Shenzhen Jermaine Technology Co., Ltd. All Rights Reserved.
Without the permission of shenzhen German technology co., LTD., no
unit or individual shall copy, transmit, transcribe or translate into other
languages in any form or means.
Due to the continuous improvement and update of our products, our
company reserves the right to modify this manual at any time without
notice.To this end, please visit the company's website frequently for timely
information.
Company website http://www.gmweighing.com/
5
Chapter 1 Overview
Weighing 10 ~ 50 kg
scale
Measuring 86L
bucket volume
6
1.1.2 Product features
4. Automatic correction
1. Intelligent: only need to set the target value, automatically adjust the
optimal speed under the condition of ensuring accuracy.
7
2. Precautions for safe use
5. Please cut off the power supply and air source when installing
the metering bucket.
8
Chapter 2. Structure characteristics and
working principle
1.3 Structure
FIG. 1
9
customers.0 is required for use.4 to 0.6 mpa, 1.The air source of 2m³/h is connected to
the air terminal, and the power supply, signal communication and control port (such
as serial port connection end, USB connection and I/O control port) are located in the
electric control box.
This product in order not to damage the sensor in transit. The measuring
hopper is disassembled and inverted in the frame of the scale body. After
receiving the product, it is necessary to install the metering bucket.
10
This product metering bucket adopts quick loading and quick unloading
design. One person can complete the installation of the metering bucket in
10 minutes.
-> takes out the measuring hopper from the frame of the scale body and
turns it upright (as shown in the figure below).
-> Insert the metering bucket horizontally into the metering bucket bracket
(as shown by the red arrow in the figure below).
Note that the beveled side of the metering bucket should be stuck on the
beveled side of the bracket.
- After > is inserted in place, align the holes and tighten the four lifting ring
bolts.
11
1.5 The working principle of
12
the discharge door, to complete a quantitative process; Before
starting the next quantification process, the device first carries
out a period of pre-feeding delay, and then carries out the next
feeding, and so on.
Please note that the standard product does not include the
function of clamping loose bag, which needs to be matched with
"clamping loose bag and double scale interlocking PLC" to realize.
13
Product size
14
Electrical connections
Air source access port Φ6 air pipe (air source standard: 0.4 to
0.5 mpa 1.2 m after/h)
15
1: Input port: 4 customizable switch input interfaces (IN1, IN2, IN3, IN4),
valid for low level, the definition of each port can be selected by
oneself.
2: Output ports: 6 customizable switching output interfaces (01, 02, 03, 04,
05, 06), the definition of each port can be selected by oneself.
3: Motor control port 1: the first group of motor control (M24+, PU1, DR1,
ZT1), used for feeding motor
4: Sensor wire port: sensor wiring port (EX+, EX-, DR1, ZT1).
5: Power line port: the instrument's 24V power port (24+, 24-).
7: status indicator light: used to indicate the internal working status of the
instrument and the input/output status.
8: Motor control port 2: the second group of motor control (M24+, PU2, DR2,
ZT2), currently not in use, reserved, PU2, DR2, ZT2 can be used as ordinary
IO port.
16
Please note that the IO port's 24V+/- and the power 24V
terminals are not connected inside the control panel.IO ports can be
powered with either an internal or external 24V power supply.
Menu description
Login screen
17
1.8 Description of touch screen login permissions
Interface description:
System date time: the date and time of the current system.
Weight display area: display the current weight and weight unit. If
the weight overflows or the sensor overflows, there will be a
reminder in Chinese in this area, such as: positive weight overflow,
negative weight overflow, etc.
User password input box: select the user account and enter the
corresponding user password
18
[In order to ensure the security of the device, please change the
initial password in time.]
Interface description:
19
total of the current formula respectively. Click the right button to
do so
Recorded data cleaning.
4. Identification box 4 shows the current state of the device at run
time, and the corresponding manual operation can be carried out when
the device is stopped
Action (Invalid run-time action).For example, in the stop state,
click "Quick Add" button to realize "Manual Quick Add"......
5. Identification box 5 represents the amount of advance that can be
set for the current formulation of the current material.
6. Identification box 6 represents the opening setting of the feeding
door for the current formulation of the current material.
7. Identification box 7 represents the time taken by each process of
the last packaging process and the results of the packaging.
8. Below the button, you can prompt the operation or enter the
corresponding page.
Interface description:
20
Working parameters: the basic parameters of the product can be set on
the working parameters interface, such as the zero clearing
range, zero clearing time, discharging mode and so on.
Historical data: the historical data interface can query the previous
packaging records and export the packaging record data to
the U disk at the same time.
21
button, will automatically adjust the data as the current
formula value after the nc data, if you quit, debugging
data recovery as conservative data of factory.
Input/output: in this interface, users can define and set the input
quantity and output quantity according to their own needs.
Among them, this control board has 4 input switches and 6
output switches (for detailed introduction, please see
4).Switching quantity description).
Users can also reset the parameters, but also for the time
and screen display related Settings.
22
1.11 Work parameter interface description
Interface description:
23
will automatically clear to zero.
24
(17)Unloading mode: time control Unloading: set the time, when the
discharge.
Delay discharge in zero zone: Delay discharge begins
after reaching zero zone.
(18)Over-range protection: when turned on, from the calibration
zero point (plus the zero cleared part), the weight is large
Is equal to specification *1.2, it is determined to be OFL,
regardless of whether the maximum range is exceeded.Prevent clearing
will be heavier
After the quantity is cleared to 0, it shows that the weight is
small, but the material has actually overflowed.
(19)Positive error mode: in the feeding process after opening, the
error band generated by the feeding result will be biased to
positive.
(20)Timing mode: discharge signal output continuous discharge time
(set in the formula parameters) and then off.discharge
After the end of the discharge of abnormal judgment;
Zero zone mode, signal signal output, until
The weight is lower than the zero zone value, then
start the unloading delay time, when the time is up, close the
unloading
The signal.After entering the discharge delay, there
is no need to judge the weight.
25
Formula parameters 1 Figure
Interface description:
26
opening of this formula is used
The opening under a table.
(12)Number of combinations: This is a read-only item. If model 0350
is selected, set the target value to 7kg-Between 10kg, the equipment
will be set to the combination feeding mode, that is, the first weighing
only Rough packaging of 5kg, the second weight is packaged on the basis
of the target value - the first weight.
(13)Time-delay T1 before feeding: at the beginning of the
quantitative process, the feeding process starts after the time delay
T1.
(14)OSS switch: The switch with OSS detection enabled.
(15)Out of tolerance: In the quantitative process, if the weighing
value > target value + over tolerance value, it will be judged as out
of tolerance.
(16)Defect value: In the quantitative process, if the weighing value
is less than the target value - the defect value, it is judged as the
defect value.
(17)Over-under-error alarm time: The duration of the output of the
over-under-error alarm after the over-error and under-error are
detected
After this time, the automatic output of over and under error alarm is invalid.
(18)Pause switch: in case of overbalance or underbalance, the meter
will stop and wait for the user to deal with it. At this time, "clear
alarm" can be provided.
Then continue to run; It can also return to the stop state after "emergency
stop".
27
1.13 Calibration scale interface description
Interface specification
(1)Unit: fixed as Kg
(2)Minimum Division: 1 2 5 10 20 50 optional.
(3)Over capacity mode: the display on the screen after exceeding the
range.
(4)Decimal point: fixed to 0.000 decimal places.
(5)Maximum Division: 0 ~ 999.999 can be set.
1. Zero point calibration: empty the hopper and close the discharge door.After
the weight is stabilized, click [Zero Calibration]. During the calibration
process, the above weight display area will display the calibration results, and
stability will be displayed after successful calibration.
2. Gain calibration: add a weight to the weighing mechanism. After the weight
is stable, click the weight input box of the weight and input the weight of the
weight to conduct gain calibration.After successful calibration, the weight
displayed in the weight display area is the weight of the input
weight.Otherwise gain calibration fails, try again.
28
1.13.2 Material calibration steps
1, zero calibration: the method is the same as the zero calibration of the
weight calibration scale.
2. Gain calibration:
B. After the bag is put, click "Clamp Bag" to clip the bag, then click "Unload"
to unload all the physical material in the hopper into the bag, click "Clamp
Bag" again to loosen the bag and weigh the material in the bag (pay attention
to remove the weight of the bag).
C. Click the input box of "Double Balance Weight" and enter the material
weight obtained by Double Balance for calibration. Wait for the calibration to
be successful.After successful weight calibration is completed, exit the menu.
29
1.14 Switching quantity interface description
30
signal and pulse signal of the motor.
(5)Switching quantity test: after opening, it can test whether the
signal of the corresponding switching quantity is normal
Input side definition:
The default
The port number Custom list
definitions
0: No definition
1: start
IN1 0 no definition 2: stop
3: stop
4: reset
5: Feeding is allowed
6: Discharging is allowed
IN2 0 no definition 7: Clear the alarm
8. Reserves (not used)
9: Open/close the discharge
door
10: manual unloading
IN3 0 no definition 11: Manual slow add
12: manually add
13: manual fast add
14: Manual cleaning
15: Start/stop (double edge)
0 no definition
16: Start/Emergency Stop
IN4
(double edge)
17: Manual unloading (double
edge)
ZT1 0 no definition 18: manual slow adding
(double edge)
19: manually add (double
edge)
20: manual fast adding
ZT2 0 no definition (double edge)
21: Manual cleaning (double
edge)
22: reset
23: Emergency stop (level)
24: The feeding door is
closed in place
25: opening limit of feeding
door
26: The discharge door is
closed in place
27: discharge door closing
limit
31
Output end definition:
The default
The port number Custom list
definitions
0: No definition
IN1
0 no definition 1: run
2: Feeding request
IN2 3: quick add
0 no definition
4: add
IN3 5: slow
0 no definition
6: fixed value
IN4 0 no definition 7: discharge
8: over and under difference
IN5 0 no definition 9: alarm
10. Reserves (not used)
IN6 0 no definition 11: The preset number of
DR1 0 no definition packages is complete
12. Complete the packaging at
one time
PU1 0 no definition
13: stop
14: Discharging motor is in
DR2 0 no definition positive rotation
15: Discharging motor reverse
PU2 0 no definition 16: feeding stepper motor DR
17: Discharging stepper motor
DR
32
1.15 Control parameter interface description
Interface specification
Interface description:
33
(2)Protocol type: communication protocol, select the protocol of
serial communication.
(3)Baud rate: Select the baud rate of the serial port.
(4)Byte format: data format.Initial value.1-8-E-1 (8-bit data bit -
parity - 1-bit stop;)
(5)Double register order: Modbus high and low word. The order of
high word first is ABCD, and low word first The order is CDAB.
(6)HMI current communication parameters: display the current
communication parameters of the touch screen.
(7)Current status of serial port 2: displays the current status of
serial port 2.
Interface description:
34
1.18 Description of the interface of automatic balance
adjustment
Interface description:
(1)Material number/name: You can set the material number and name.
(2)Recipe number/target value: Sets the recipe number and target
value.
(3)Adaptive & Automatic Adjustment Scale Grade: It can be divided
into four grades in total. Grade 0 is the fastest and the grade is
higher
The higher the speed is, the slower the
time difference between adjacent levels is 0.2 s.
(4)Open degree automatic adjustment: this function is not open.
(5)Feeding level: not set, display the current feeding level.
35
automatically adjustable scale level automatically adjustable
scale, the scale number of arrival device will automatically
stop, at the same time, the user can choose according to
automatic adjusting the scale value save or give up, keep will
automatically adjusting the scale of values stored to the current
formula, give up the automatic adjusting the scale of value
reduction is conservative values.If the scale adjustment fails to
meet the user's requirements, the customer can start the
automatic scale adjustment again, and the equipment will be
adjusted and corrected again on the basis of the previous scale
adjustment.Users can also modify parameters such as advance and
opening according to the current permissions.
Interface description:
Displays the current login user, can change the password and set the
automatic login.
36
The user level of this system is divided into four levels, from high
to low: reserved user (used by manufacturers), engineer, administrator
and operator.
★ Change password
Path: Parameter Settings User Management Change Password Click the
password input box to follow the prompts
37
System information 2 figure
Interface description:
38
System information 1 is the equipment information diagram.You can
see the name of the device, model, software version, manufacturer,
support phone number, and so on.
USB flash drive upgrade interface, click the USB flash drive
upgrade from the system information 1 diagram to enter the USB flash
39
drive upgrade diagram, enter the USB flash drive upgrade interface to
upgrade the program USB flash drive. The steps are as follows. Please
check the chapter of USB flash disk upgrade system:
Can export HMI internal history data to USB drive.After the USB
flash drive is inserted in the back of the HMI, the controller
recognizes the USB flash drive normally, and the button "USB flash
drive export" will display black.Otherwise, the data path and
filename are exported as follows:
40
"USB flash character :\data_gm\ gmf01packdata_yyyymmdd.csv '"
(yyyymmdd: indicates the date of the export time).Excel software can
be opened to view and process.
Please note that the USB flash drive needs to be plugged into
the USB port at the back of the HMI.
First plug in the USB flash drive, click the USB flash drive
upgrade from the system information 1 diagram to enter the USB flash
drive upgrade diagram, enter the USB flash drive upgrade interface
can be upgraded to the program USB flash drive. Here are the steps:
-> inserts a USB disk with upgrade file into the USB interface of
the main control board. The path and file name of the upgrade file
are as follows:
Please note that the USB disk needs to be inserted into the USB
interface of the main control board.
-> waits for the interface to show that the USB flash drive is
ready, and the upgrade file version number is displayed: if not
ready, please check whether the USB flash drive (USB2.0,FAT32 format)
and directory name and file name are correct.
41
If the upgrade was successful, it will be shown as successful,
otherwise it will be shown as failed. The upgrade file stored on the
USB flash drive will look like the image above.
[If you do not have the upgrade file, you need to call the technical
support department of our company to get the USB disk upgrade file]
When the external input operation signal is valid, the meter enters
the running state and starts the automatic packaging process.
5. After feeding, output fixed value signal and start fixed time.
42
9. Over-under-error switch, if turned on, will be processed for
the over-under-error function.
11. When the discharge time is up, turn off the discharge output
and output the completion signal.
After the over and under detection function is turned on, the
current feeding result will be judged after the completion of the
fixed value holding time in the operation process:
The feeding result > target value + out of tolerance value is judged
as out of tolerance, and the out of tolerance alarm signal is
output.
When the overage and underage situation occurs, if the overage and
underage pause switch is turned on, the controller will temporarily
determine the packaging process and prompt the overage and underage
43
pause and wait for the user to process. The user can input clear
alarm signal to continue the packaging process or input emergency
stop signal to enter the stop state and no further packaging.
44
single scale is not
set to 0
1. Equipment not 1. To a scale
calibrated 2. Fast ban than the appropriate
2. The fast disable is time to reduce
The actual
too large than the 3. Increase the pressure
weighing
time setting
3 has been
3. Air source pressure
out of
is too low,
tolerance
resulting in a long
closing time of the
feeding door
1.There are strong 1.Check and exclude
winds or strong 2.Check the sensor and replace it
Indicated vibrations in the if necessary
4 value is surrounding
not stable environment
2.Weight sensor
failure
1.Weight sensor 1.Check the sensor and replace it
failure if necessary
The
2.It was not cleared 2.Stop reset
weighing
before use 3.recalibrate
5 weight is
4. Equipment not 4.Increase discharge time
not up to
calibrated appropriately
standard
5. Incomplete
discharge
1.U disk is damaged 1.Replace the U disk
Data
2.Interface of U disk 2.Check the interface
6 cannot be
in electric control
exported
box is damaged
45
Maintenance and warranty
In order to ensure the weighing accuracy of the equipment, do not place the
equipment in a cold and wet environment. Clean the dust caused by materials
inside the equipment regularly according to the use situation. Remember to
close the door of the electric control box after daily use or maintenance.
● Warranty principle
46
⚫
Adopt reverse measures for transport protection restoration. Here are the
steps:
2. The lower flange of the equipment is fixed on the bottom plate of the
transport wooden box by bolts.
47
5.
1.Accessories: equipment side panel open key, packing list, invoice, product
specification and quality inspection list
2.Open the box to check whether the accessories are complete and whether
the equipment packaging is damaged
48