XNX
XNX
XNX
A universal transmitter for toxic, oxygen and combustible gas detection compatible with all Honeywell gas sensing technologies
Flammable gas detection 0 to 100% LFL/LEL Point IR with heated optics provides immunity to poisoning and no hidden faults Open-path IR flammable gas detection in LEL-m measurement Electrochemical cell offers toxic gas detection in ppm IR cell provides CO2 and combustible gas monitoring Robust and reliable operation in explosive areas and harsh environments 3 versions - supports mV (Catalytic Bead and IR Cell), Electrochemical Cell and IR (point and open-path) gas detection Multi-Purpose Detector (MPD) with field serviceable mV, Catalytic bead and IR Cell capability 4-20mA with HART as standard Multiple communications options include up to 3 relays, MODBUS and FOUNDATION H1 Fieldbus (pending) Optional local IS port for handheld HART configurator
High performance
The XNX Universal Transmitter marks a new turn in gas detection from Honeywell Analytics. It supports the widest range of sensors on a common platform and offers a modular choice of inputs and outputs.
XNX is designed for flexible integration, simple installation, user friendly operation and straightforward maintenance. It is ideal for use with a range of gas monitoring controllers or industry standard PLCs. Users are assured of being protected in all conditions with Honeywell Analytics gas monitoring solutions.
XNXs modular design enables Honeywell Analytics to offer appropriate, cost effective solutions to a wide range of gas detection requirements. The XNX Universal Transmitter is an excellent choice for those who want a total integrated monitoring and safety solution for an industrial plant. With the XNX, you are freed from the need to add extra controllers, junction boxes, relays, monitors and other equipment accessories.
Flexible Operation
Catalytic Bead
Easy to Use
Large, backlit, easy-to-view LCD display offers multisensory indicators (visual icons, colored buttons, text, etc.) to display gas and sensor readings User interface supported by 8 selectable languages (English, Spanish, German, Italian, Portuguese, French, Russian, Chinese) Self-test and fault indication features Non-intrusive, one-man operation Quick calibration with auto-inhibit 3 or 4 wire operation, source, sink or isolated Use with conduit or cable installations Simple plug-in sensors and replaceable cells NEMA 4X IP66 rated for rugged indoor/outdoor use Minimal training required One-man operation Plug-in sensor replacement All necessary accessories included Offshore Oil & Gas production platforms Onshore Oil terminals Refineries Gas Transmission Gas Distribution LNG terminals Gas storage terminals Chemical plants Petrochemical plants Solvent recovery operations
IR Cell
Electrochemical
Infrared
Easy to Install
Cost Effective
Applications
mV
EC
IR
Communications
Installation Details
Mechanical
The XNXs powerful advanced communications module adds increased functionality and flexibility to a gas detection network. Standard HART communications, along with optional Modbus, Foundation Fieldbus (pending) or relays, interface with a PLC and a host of other protocol compatible devices found in industrial applications. Back-lit, easy-to-read LCD display with icons includes a broad range of language options including English, Spanish, French, Italian, Portuguese, German, Russian and Chinese to meet global requirements.
The XNX enclosure is available in a painted stainless steel or aluminum housing with a marine grade coating. Five threaded conduits/cable entries are available in Metric or NPT versions, and ruggedized mounting options provide ultimate installation flexibility. Instrumentation built on various sensing technologies can be attached locally to the transmitter or remotely with the appropriate
accessories. Inside, customer and sensor connections to the unit are designed to protect against dangerous electrical misconnections. With pending approvals to UL, CSA and ATEX requirements for Hazardous Locations, and IP66/67 rating to protect against dirt/water ingress, the XNX serves the most demanding industrial environments.
Ordering Information
The XNX part numbering system contains all necessary information to convey the product configuration including options. Agency, Port Thread, Enclosure Material, Sensor Personality define the standard unit. Three option fields are used to define optional Relay or Fieldbus interfaces and factory installed local HART. To order XNX parts, call 800-538-0363.
XNX-AM
Enclosure q Stainless - S
Sensor and Range q q None - NNN MPD-AM (Catalytic Bead %LEL) - CB1 MPD-AMIF1 (IR %LEL Flam) - IF1 MPD-AMIV1 (IR CH4 0-5% Vol) - IV1 MPD-AMIC1 (IR CO 0-2% Vol) - IC1
Aluminum - A Infrared - I
Foundation Fieldbus - F
TM
Technical Summary
Technical Summary
XNX Transmitter Material Cable Entries Termination Mounting User interface Signal Environmental Temperature Humidity IP Rating Options Form C and SPDT 3 Relays, 240 VAC, 5A (2 Alarm, 1 Fault) (Mutually exclusive with Modbus and Fieldbus Options) Power 18V to 32V (24V nominal) Hazardous Area Approvals (Pending) ATEX: Ex II 2 G D, EEx [ia] IIC T5 (Tamb -40C to +65C) UL: Class I, Div 1, Groups B, C, and D / Class 1, Zone 1 AEx d IIC T5 (Tamb -40C to +65C) CSA: Class I, Div 1, Groups B, C, and D T5 (Tamb -40C to +65C) Performance Approvals (Pending) EU ATEX, EN45544, EN50104, EN50270, EN50271, EN13980, EN60079, EN60079-18, -1, -7, -29-1, EN45544-1, -2 NA UL 913, UL 1203, CSA 22.2 No. 152 Other IEC61508 (SIL Assessment, SIL 2), IECEx OD 005 -40C to +65C / -40F to +149F (sensor dependent) 20 to 90% RH non-condensing NEMA 4X IP65 LM25 Aluminum, painted (SS316 painted optional) 5 conduits/cable entries (2 right, 2 left, 1 bottom) Available in NPT, or M25 Cage Clamp pluggable Terminal Blocks with retaining screws, 0.5 to 2.5mm (12-28 AWG) XNX Enclosure Bracket (ears on casting for u-bolt). Integral cast mounting flanges provide secure mounting to surfaces, channels or up to 6 Pipe. Optional Remote sensor (up to 50 ft / 15.2 M) for Cat Bead and Toxic Standard Custom Backlit LCD. 2.5 High Resolution DOT Matrix Display. Discrete Alarm and Status indication. Reliable Non-Intrusive 4 button interface magnetic wand access. Optional HART Handheld with IS Port Standard HART over 3-wire 4-20mA (sink or source). Optional Modbus over RS-485 and Foundation Fieldbus
Relay Module (Optional) Description Installation Rating Electrical Connections Provides three fully user configurable relay outputs that can be switched based on the current gas level and/or status of the transmitter. Provides 2 x SPCO alarm and 1 x SPCO fault relays. Single Pole Double Throw SPDT. Option PCB Factory installed in display module. Fitted into housing base either at the factory or in the field by qualified service engineer. Maximum: 240VAC, 5A (non inductive load) Fault: Common, Normally Open, Normally Closed Alarm 1: Common, Normally Open, Normally Closed Alarm 2: Common, Normally Open, Normally Closed Default Fault Relay: Normally energized Non latching Signal inhibit as fault Alarm 1 / 2 Relays: Normally de-energized Non latching Alarm rising on gas reading Alarm level 20% and 40% of scale Hysteresis of 2% of scale Re-setting of Latched Relays Note Relay Specific Functions via HART Interface Description Installation Connections Physical Layer Maximum No. of Nodes Functions Supported Configurable Options Fault Relay: Normally energized / normally de-energized None Enable/disable A1 / A2 Relays: Normally energized / de-energized Latching / non latching Alarm on rising / falling Alarm level 10% to 90% of full scale Minimum: 5V, 10mA (non inductive load)
Configuration
Easily accessible interface on display (if used) or via HART interface (local or remote) Use of the Relay Module or Other Communications Module (E.g. Foundation Fieldbus) is mutually exclusive. However, relay function may be used in conjunction with standard communication output i.e. 4-20mA with HART. Relay status information / Reset of latched conditions / Configuration of relays Forcing of relay state Reset through non intrusive User Interface. Remote Switch closure using Remote Reset input Remotely through HART Foundation Fieldbus compliant digital communications interface enables connection of the XNX transmitter to a multi-drop Foundation Fieldbus H1 network. Fitted into housing base either at the factory or in the field by qualified service engineer. Sig+, Sig- and Screen Conforms to IEC 1158-2 and ISA 50.02, 31.25Kbits/s 32 Gas Reading Gas Name and Units of measurement Instrument status (OK, warning, fault, over-range) General/Device Information Remote zero and span calibration (detector dependent) Detailed Sensor Information Including: Optical Signal Level Dynamic Reserve (Excel Only) Raw reading 24V supply voltage Temperature RTC (Excel Only) Calibration and Configuration status Detailed Fault and Warning Information: Fault and Alarm History Zero Calibration
Display Module & User Interface (Standard) Display Type Information Displayed Backlit LCD Base Information: Gas Reading Gas Name and Units of measurement Fault and Alarm Status Large Numeric concentration or LEL display Bar graph showing current reading, set points and full scale. Security settings allow multi level operator access for set-up, configuration and calibration Event history stores Time and Date of all Alarm, Diagnostic, Configuration events
Modbus RTU Module (Optional) Description Installation Connections Physical Layer Maximum No. of Nodes Protocol Functions Supported The Modbus output module provides an Isolated RS485 output to enable the connection of the XNX transmitter to a multi-drop Modbus network Fitted into housing base either at the factory or in the field by qualified service engineer. RS485+, RS485-, Drain Isolated RS485, 1200 to 19.2K Baud 254 XNX compatible transmitters only Modbus RTU As per Foundation Fieldbus Module (Optional) - see above
4-20mA & HART (Standard Supply) Description Non-intrusive Interface Operating Modes Output Range 4-20mA Signal Accuracy Max loop resistance Functions Supported via HART Fully configurable isolated 4-20mA & HART output module providing current sink, current source and isolated modes of operation. (supports HART 6.0 protocol) Optional local IS port to enable HOT connection of a HART handheld configurator Current sink / Current source / Isolated current sink /Conventional or with HART data 0 to 22mA +/- 1% FS 600 Ohms at 24Vdc loop supply Gas Reading Gas Name and Units of measurement 4-20mA signal level General/Device Information Installation Configuration Forcing of 4-20mA output Detailed Sensor Information Including: Optical Signal Level Dynamic Reserve (Excel Only) Raw reading 24V supply voltage Temperature RTC (Excel Only) Calibration and Configuration status Detailed Fault and Warning Information Fault and Alarm History Zero Calibration
Further information is available upon request. * Foundation Fieldbus not available at time of publication. Please call your Honeywell Analytics sales person. XNXTM is a registered trademark of Honeywell International. HART is a registered trademark of the HART Communication Foundation. MODBUS is a registered trademark of Schneider Automation Inc. FoundationTM is a trademark of Fieldbus Foundation.
Local IS HART Port (Optional) Description Installation Environmental Protection Provides externally accessible IS connections to the XNX transmitter to enable HOT connection of HC275/375 HART or equivalent hand held configurator. Fitted to one of the cable entries on the XNX transmitter. Terminals protected by cover to IP 66 when not in use
Commercial
Industrial
Vulcain-brand gas detection from standalone units to fully engineered, multipoint systems, all offering cost-effective regulatory compliance Applications: parking structures, chillers, mechanical rooms, office towers, commercial buildings, shopping centers, swimming pools, golf courses, schools and universities, laboratories
Renowned Sieger and Manning gas detection systems with advanced electrochemical, infrared and open path sensing technologies Applications: oil and gas, cold storage, water/wastewater treatment, chemicals, engine rooms, plastics and fibers, agriculture, printing and light industrial
Portables
Single or multi-gas Lumidor and other premium detectors with compact, lightweight designs ranging from simple alarm only units to advanced, fully configurable and serviceable instruments Applications: underground utility and electricity ducts, boiler rooms, post-fire sites, sewers, industrial plants, industrial hygiene, first responder teams, remote fleets
High Tech/Government
Find out more www.honeywellanalytics.com Contact Honeywell Analytics: Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 8210 [email protected]
A complete portfolio of gas and chemical detection instrumentation including infrared spectroscopy (MST) with no cross interference, to Chemcassette paperbased solutions (MDA Scientific) offering detection down to parts per billion Applications: semiconductor manufacturing and nanotechnology, aerospace propulsion and safety, specialty chemicals industry, research laboratories, emergency response
Europe, Middle East, Africa Life Safety Distribution AG Wilstrasse 11-U31 CH-8610 Uster Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 [email protected]
Technical Services
24/7 global network includes post-sales service and Systems Integration teams Emergency call out, service contracts, on/off-site repair, training and commissioning Complete range of spares, consumables and accessories
Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (I) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050 Korea Tel: +82 (0)2 2025 0307 Fax: +82 (0)2 2025 0329 [email protected]
HWA6181
Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.
H_XNX_DS01071_V1 9/08 2008 Honeywell Analytics