0% found this document useful (0 votes)
626 views1 page

OPC 43 Grade: ACC Limited

This document provides test results for ordinary Portland cement from a cement works. It includes 15 test parameters for chemical composition and physical analysis. The test results all comply with the requirements of IS 269: 2015 for ordinary Portland cement.

Uploaded by

Rajneesh kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
626 views1 page

OPC 43 Grade: ACC Limited

This document provides test results for ordinary Portland cement from a cement works. It includes 15 test parameters for chemical composition and physical analysis. The test results all comply with the requirements of IS 269: 2015 for ordinary Portland cement.

Uploaded by

Rajneesh kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

IS 269: 2015

ACC Limited
Registered Office: Cement House, 121, Maharishi Karve Road, Mumbai – 400020
CM/L 9092177 Unit: Gagal Cement Works

(For Ordinary Portland Cement)


OPC 43 Grade
Dispatched during 35 Quantity 1000 From 27/08/2023 To 02/09/2023
Week No.
Test Certificate 35 GL/LAB/TC/O43/2023-
03/10/2023 Reference No. 35
No. Dated
Test Requirement as per
S.N. Parameters
Results IS 269: 2015
Chemical Composition
1 Lime Saturation Factor 0.90 0.66 - 1.02
2 Ratio of Percentage of Al2O3 to Fe2O3 1.54 0.66 minimum
3 Loss on Ignition (% by mass) 2.49 Not More than 5.0%
4 Magnesia (MgO) (% by mass) 2.77 Not More than 6.0%
5 Sulphuric Anhydride (SO3):(% by Mass) 2.97 Not More than 3.5%

6 Chloride Content (% by Mass) 0.007 Not More than 0.1% for general purpose & not more
than 0.05% for pre-stressed structures
7 Insoluble Residue (% by mass) # 2.02 Not More than 5.0%
Physical Analysis
Fineness
8 Blaine’s / Specific Surface Area (m2/kg) 365 Not Less than 225
Compressive Strength (MPa)
9 72 ± 1h (3 Days) 32.4 Not less than 23.0
10 168 ± 2h (7 Days) 37.7 Not less than 33.0
11 672 ± 4h (28 Days)* 51.4 Not less than 43.0
Setting Time (Minutes)
12 Initial 120 Not less than 30
13 Final 170 Not more than 600
Soundness
14 Le-Chatelier Expansion (mm) 1.0 Not more than 10.0
15 Auto-Clave Expansion (%) 0.20 Not more than 0.8
16 Normal Consistency (%) 29.0
Temp. During Testing (0C) 27.0 (27 ± 2)0 C
# Type of PI (Performance Improver) added (As per IS 269:2015 clause 5.1.1)
# PI (Percent Addition by mass) - Not more than 5.0%
* Compressive Strength (in MPa) of 28 Days value is of Week No 35

The test results of above cement comply with the requirements of IS 269: 2015 for Ordinary Portland Cement.

Special test (If any) Name of the test Test result

Head Quality) Head Production

You might also like