English

Installation Instructions - For Service Persons Only

Part no: MB4000

micro ScanDisk
2 GB micro
SD

SD

2000x Remotes, 8 User Passwords, microSD Card, USB


2 x Relays, 1 x Siren, AC fail, RS-485, Low battery detect,
4000 x GSM numbers, Full event log.

12VDC

III
TABLE OF CONTENTS
Program mode Pg1
Specifications, Features & Applications Pg2
Mounting hints Pg2
Wiring Diagram Pg.3
Time & Date Setting Pg.4
Programming a Remote or RF device Pg.4
Deleting a RF device Pg.5
Programming Custom Text Pg.5
Enrol a BUS device Pg.5
Enrol Repeaters Pg.6
GSM numbers Pg.6
Set Relay outputs Pg.7
Set Passwords Pg.7
Backup the system Pg.7
Install a Backup Pg.8
Defaulting the unit Pg.8
Testing remotes Pg.8
AC Fail explained Pg.9
User menu Pg.9
How to operate the system Pg.10
Viewing Events & Saving Events to the microSD card Pg.10
Firmware update Pg.11

PROGRAM MODE
Follow the instructions to enter into Program mode with the ADMIN code before you begin

28/06/2013 16:56:03 ENTER PASSWORD 1 SET TIME/DATE


2 PROGRAM RF
Mb4000 MIMIC BASE 1234 3 ENROL BUS DEVICE
4 ENROL REPEATERS
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Press the Enter button Use the Keypad to type in the Use the Down arrow key to
units ADMIN code. select the Menu you wish to
Default is: 1;2;3;4 Program. Press Enter to
continue or Scroll down to
Exit to go out of Program mode

Pg.1
Specification, Features & Applications
Specification:
Encryption: Code-Hopping
Operating Range: 500m (Open air)
Frequency: 403MHz or 433MHz
Memory Capacity: 2000 Remotes
Events memory: 2000 Time/Date
Outputs: 2 Dry Relays
1 x SIREN (800mA)
Connectivity: 1 x AC Fail (150mA)
1 x USB(2)
Inputs: 1 x microSD (FAT32)
GSM & LAN (UARTS)
RS-485
Voltage Input: 9.8V - 16VDC Features
Current draw: 80mA Memory Capacity of 2000 Remotes
Dimensions (lxbxh): 167 x 130 x 35mm Low battery detection
Gross Weight: 0.6 Kg
microSD card for backing up
Operating Temp: -3°C to 60°C
Warranty: 24 Months USB 2.0
Release Date: June 2013 40 Character custom text programmable
SMS Input & Output commands
Programming remotes via an SMS
Applications Internal Piezo buzzer notification
Shopping Centre Panic System
Up to 8 x Data receivers per unit
Frail Care Nurse-call System
Monitoring Software GUI with Reporting
Retirement Village Alarm Monitoring
User codes & full event logging of all actions
Housing Estate Alarm Monitoring
Keeps time & date for a day if de-powered
Office Park Alarm Monitoring
Resort Alarm Monitoring

Approvals:
This product is approved for use in residential, commercial and light
Industrial environment and complies with the essential protection
requirements of the R&TTE Directive 1999/EC on the approximation
of the laws of the Member states relating to electromagnetic
compatibility and radio spectrum.

Certifications:
IEC 60950-1:2005 + A1:2009
III

Order Codes:
MB4 0 0 0
Mimic Base control panel: Code-hopping MB4000

For more info visit our web site: www.sherlotronics.com


Pg.2
Wiring Diagram

AC SIREN RELAY RELAY DATA BUS


NEG +12V MON NEG +12V COM1 NO1 NC1 COM1 NO1 NC1 B A NEG 12V

microSD USB
NEG Card
holder
+12V
RS-485 BUS +12V
NEG
B
A

AC FAIL Max: 4
Do not exceed
1000m cable run
Relay 1 Relay 2

COM

COM
DATA RECEIVER

Siren
Please refer to [3] PROGRAM ASKDRX]
NORMALLY OPEN

NORMALLY OPEN
-+ menu after you have powered the Data
NORMALLY CLOSED

NORMALLY CLOSED
receiver up for the first time.
You can enrol up to 8 x Receivers.

Pg.3
[1] TIME / DATE SETTING
Follow the instructions to enter into Program mode with the ADMIN code before you begin

1 SET TIME/DATE - SET DATE / TIME - - SET DATE / TIME -


2 PROGRAM RF
3 PROGRAM ASKDRX dd/mm/YYYY hh:mm:ss dd/mm/YYYY hh:mm:ss
4 ENROL REPEATERS 29/05/2013 16: 53 :00 29/05/2013 16: 53 :00
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Use the up & down buttons Use the Left & Right and When finished press the ENTER
to Select SET TIME/DATE enter the applicable date Then scroll down to Exit and press
Press the Enter followed by the time. the Enter button again

[2] PROGRAM A REMOTE CONTROL or TRANSMITTER DEVICE


Please note: Before you begin, make sure the ASKDRX Data Receiver is wired up and programmed in
before you start. Follow step [3] on page 5. [3] PROGRAM ASKDRX

2 PROGRAM RF No: 1 EMPTY No: 1


3 PROGRAM ASKDRX ------------TEXT------------- 1 - LEARN RF
4 ENROL REPEATERS 2 - DELETE RF.
5 GSM NUMBERS
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Use the up & down buttons Press either the > to select Press button 1 to Learn
to Select PROGRAM RF a No: that is EMPTY or you can in a RF Remote control devices
Press the Enter type in a number. to the units memory.
Once you have decided on a
No: Press the MEMORY
button.
PRESS REMOTE BUTTON
3X TO LEARN IN.

>
Memory Reset Cancel > ^
^ 3 beeps
1 2abc 3def

4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space


Press three times
The screen will prompt: PRESS REMOTE BUTTON 3x LEARN IN.

Once it is Learn in the unit will Beep to confirm when you press the remote.
To test that the remote is Learnt in, press the remote few times and make
sure the unit beeps to acknowledge that it is correctly learnt in. To Exit back to the MAIN Menu, Press the
ENTER button or continue with Learning in additional Remotes to the unit.

Pg.4
[2] DELETE RF DEVICE
Follow the instructions to enter into Program mode with the ADMIN code before you begin

2 PROGRAM RF No: 1 FULL No: 1


3 PROGRAM ASKDRX ------------TEXT------------- 1 - LEARN RF
4 ENROL REPEATERS 2 - DELETE RF
5 GSM NUMBER
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Use the up & down buttons Press either the > to select Press button 2 to Delete the RF
to Select PROGRAM RF a No: that is FULL or type Remote control from the units
Press the Enter in the No. Press the MEMORY memory. The unit will Beep and
button to continue. display [DEVICE DELETED]

[2] PROGRAM IDENTIFICATION TEXT


Follow the instructions to enter into Program mode with the ADMIN code before you begin

2 PROGRAM RF No: 1 FULL No: 1 FULL


3 PROGRAM ASKDRX ------------TEXT------------- ------------TEXT------------
4 ENROL REPEATERS _
5 GSM NUMBER
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Use the up & down buttons Press the Down button to make You can now type in the description
to Select LEARN/DELETE RF the cursor drop to the bottom of the remote using the keypad.
Press the Enter of the screen. Use the < & > buttons to go back
and forth and use the Up button once
finished the description to program a
new No:
[3] PROGRAM THE DATA RECEIVER
Follow the instructions to enter into Program mode with the ADMIN code before you begin. Always Delete ALL
devices first if you start a new installation or have done a Factory Default, then Auto Learn all.

3 PROGRAM ASKDRX PROGRAM ASKDRX AUTO LEARN


4 ENROL REPEATERS 1: AUTO LEARN
5 GSM NUMBER 2: DELETE ALL ID:1 24031
6 SET RELAY OUTPUT 3: EXIT
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Make sure the Data Receiver You can either Auto learn all Up to 4 ASKDRX’s can be Learn
(ASKDRX) is wired up as per device automatically or Delete into the MB4000. Make a note of each
the wiring diagram before you all. We recommend first deleting units ID code if installing more than 1 unit.
continue. all before you start a new Press Enter when you are done
installation.
Pg.5
[4] ENROL REPEATERS
Follow the instructions to enter into Program mode with the ADMIN code before you begin
4 ENROL REPEATERS REPEATER:1 EMPTY REPEATER:1
5 GSM NUMBER REPEATER:2 EMPTY 1 - ADD REPEATER
6 SET RELAY OUTPUT REPEATER:3 EMPTY 2 - DELETE REPEATER
7 SET PASSWORD REPEATER:4 EMPTY
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Make sure the Data Receiver is Select a Repeater No: using the Press button 1 to ADD
wired up as per the wiring diagram Up / Down keys followed by the Repeater to the unit for
before you start. Press the Enter pressing the MEMORY button Supervision of the Device.
button to continue. The unit does a supervision
check every 4 hours.

ENROL REPEATER NOW.. REPEATER:1 FULL


REPEATER:2 EMPTY
9E01AC23ACEFDE20 REPEATER:3 EMPTY
REPEATER:4 EMPTY
>
Memory Reset Cancel > ^ >
>
Memory Reset Cancel ^
^
1 2abc 3def ^
1 2abc 3def

4ghi 5jkl 6mno Enter


4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space


7pqrs 8tuv 9wxyz 0space

Now bridge the SUPERVISION Select a Repeater No: using the


jumpers on the RPT-800_V2 Up / Down keys followed by
Repeater unit. pressing the MEMORY button
or Press Enter to go back to the
main menu screen
[5] GSM Numbers
Follow the instructions to enter into Program mode with the ADMIN code before you begin

5 GSM NUMBER SELECT GSM NUMBER CALLING CODE: +27


6 SET RELAY OUTPUT 1 - SET MASTER CELL1:
7 SET PASSWORD 2 - SET INDIVIDUAL CELL2:
8 BACKUP SYSTEM CELL3:
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Use the up & down buttons Press either button 1 or 2. Using the Keypad enter the GSM
to Select GSM NUMBERS 8 Master numbers can be number that will receive a SMS.
Press the Enter set and 2 individually numbers Press the RESET button for 2sec
per remote RF device. to clear the blocks if you make
an error or to try and clear a zero to
type a calling code like +27_.
Please refer to this link : http://wikitravel.org/en/List_of_country_calling_codes on the web
for reference to all the international calling codes used. The unit is set for South Africa
as its default code which is +27_.
Pg.6
[6] SET RELAY OUTPUTS
Follow the instructions to enter into Program mode with the ADMIN code before you begin
6 SET RELAY OUTPUT RELAY1 [003] RELAY1 [003]
7 SET PASSWORDS RELAY2 [180] RELAY2 [180]
8 BACKUP SYSTEM
9 INSTALL BACKUP *Time is in seconds* *Time is in seconds*
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Use the up & down buttons Use the Left & Right and When finished press the ENTER
to Select SET RELAY OUTPUT up & down button to move the to return to the Main menu.
Press the Enter cursor. A max of 999 seconds
can be set.
[7] SET PASSWORDS
Follow the instructions to enter into Program mode with the ADMIN code before you begin

7 SET PASSWORDS 1 USER 1: **** 1 USER 1: 2576


8 BACKUP SYSTEM 2 USER 2: **** 2 USER 2: ****
9 INSTALL BACKUP 3 USER 3: **** 3 USER 3: ****
10 FIRMWARE VERSION 4 USER 4: **** 4 USER 4: ****
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Enter a unique 4-digit code for the When finished press the ENTER
Use the up & down buttons user. Use the up & down keys to return to the Main menu.
to Select SET PASSWORDS to move to other users. Press &
Press the Enter hold RESET to clear a whole code
if not in use.
Note: If you want to RESET the ADMIN password back to default, then power up the unit whilst pressing
the Cancel button. Default is: 1;2;3;4

[8] BACKUP THE SYSTEM


Follow the instructions to enter into Program mode with the ADMIN code before you begin
8 BACKUP SYSTEM CONFIRM REQUEST BACKING UP TO MICRO
9 INSTALL BACKUP
10 FIRMWARE VERSION 1) YES SD CARD 100%
11 DEFAULT 2) NO
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Make sure you have a clean When finished press the ENTER
formatted microSD card Press button 1. to return to the Main menu.
inserted. You can format a card
in menu 13. Press Enter
Pg.7
[9] INSTALL A BACKUP
Follow the instructions to enter into Program mode with the ADMIN code before you begin

9 INSTALL BACKUP CONFIRM REQUEST -INSTALLING BACKUP-


10 FIRMWARE VERSION CODES - DONE
11 DEFAULT 1) YES TEXT - DONE
12 TEST 2) NO CELL -DONE
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Make sure you have a clean Press button 1. The unit will start the backup
formatted microSD card process which will take about
inserted. Press Enter 80 seconds.

[11] DEFAULTING THE UNIT


Follow the instructions to enter into Program mode with the ADMIN code before you begin
11 DEFAULT 1 CELL NUMBERS CONFIRM REQUEST
12 TEST 2 REMOTE CODES
13 FORMAT SD CARD 3 EVENTS 1) YES
14 EXIT 4 TEXT 2) NO
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

When finished scroll to 6 Exit


Use the up & down buttons You can just clear certain parts to go back to the MAIN Menu.
to Select SET RELAY OUTPUT of the units memory or do a full
Press the Enter Factory Default. Scroll down to the
relevant function and press Enter

[12] TESTING REMOTES


Follow the instructions to enter into Program mode with the ADMIN code before you begin

12 TEST PRESS REMOTE TO TEST PRESS REMOTE TO TEST


13 FORMAT SD CARD REMOTE: 1
14 EXIT CUSTOM TEXT HERE
AND HERE
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Use the up & down buttons You can TEST to see if the remotes When finished press Enter
to Select TEST that you programmed in are working. to return to the MAIN menu.
Press the Enter The unit should beep and display the
remote No: The TEST mode will not
trigger the GSM output or switch the
Siren and Relays on.
Pg.8
AC FAIL
The unit will trigger an AC FAIL event if the AC MON input is 28/06/2013 16:56:03
connected to the 3.2A power-supply AC Fail output. The AC
Monitoring input requires a +12V logic level to work. When [AC FAIL]
+12V restores to 0V the unit will clear the AC FAIL message. >
>
Memory Reset Cancel ^
Please note: The unit will not activate its Relays or Siren output
^
when it detects a AC fail conditions. It will only Send out a SMS 1 2abc 3def

message and log the Event into the event register. 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space

USER MENU
Follow the instructions below to enter into USER Program mode with a USER code before you begin

28/06/2013 16:56:03 ENTER PASSWORD 1 SET TIME/DATE


2 SET RELAY OUTPUT
MB4000 MIMIC BASE 1234 3 BACKUP SYSTEM
4 FIRMWARE VERSION
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Press the Enter button Use the Keypad to type in any Use the Down arrow key to
of the 8 USER codes. select the Menu you wish to
Program. Press Enter to
continue or Scroll down to
Exit to go out of Program mode

The USER PIN code will give the user five menu functions. The following menus are available for the
USER pin code to access.

1. Setting the Time & Date


2. Setting the Relay contact time
3. Backing up the system to a microSD card
4. Checking the Firmware version
5. Testing remotes

Any changes made to the unit will be logged in the event log with the USER’S PIN CODE and the changes
that were made to the unit. This will prevent any unauthorised changes made to the unit.

Pg.9
HOW TO OPERATE THE SYSTEM
The MB4000 unit will respond as a 24hour input to remote controls or Alarm transmitters that are
programmed to the unit. When a valid signal is received the unit will sound its internal buzzer and
will prompt the user to Enter a PIN CODE. The pin code is a 4 digit number that is issued to a user on
installation of the product. The unit is able to store up to 45 Events in a buffer memory if they are not
reset by a PIN code. A pin code will need to be entered to reset each signal received.
The ADMIN code is a PIN CODE issued for either entering the unit into Program mode or can RESET
all events in memory at once. The ADMIN default code is 1,2,3,4 and should be changed when
the unit is installed.

Receiving a signal screen


Date the signal was received
Time of the activation
MB4000
Remote no#
The unit can 28/06/2013 16:56:03
store from #1 E:1 Event number stored
#1 - #2000 in buffer memory
TESTING A PANIC Up to 45 can be stacked
BUTTON into its memory.

Up to 40 Characters of Custom
text that was programmed to the
remote No#

VIEWING EVENTS / SAVING EVENTS TO MICROSD CARD


You can either View the events that the unit has stored in its memory, or save them to a microSD card.
Press the MEMORY button on the far top left of the keypad and follow the prompts on the screen.

28/06/2013 16:56:03 --EVENTS DISPLAY-- 10/07/2013 17:59:20


1) SAVE TO SD CARD No:1 ADMIN
MB4000 MIMIC BASE 2) VIEW EVENTS TESTING A PANIC
3) EXIT BUTTON
> > >
Memory Reset Cancel > ^ Memory Reset Cancel > ^ Memory Reset Cancel > ^
^ ^ ^
1 2abc 3def 1 2abc 3def 1 2abc 3def

4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter 4ghi 5jkl 6mno Enter

7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space 7pqrs 8tuv 9wxyz 0space

Saving Events to a microSD card

First make sure the microSD card is formatted to FAT32. Then insert the
card into the slot on the bottom right of the unit.
Press MEMORY, followed by 1. The unit will then start the process.
When done you can eject the microSD card and view it on a pc in either
Note pad or Import it to Excel.
ScanDisk
micro
SD
2 GB

Pg.10
FIRMWARE UPDATE
It is possible to update the units Firmware. Please consult with us for the availability of a new software
version. As we make improvements we will make the firmware available.

The procedure to update the firmware is as follows.


Save the firmware onto a formatted microSD card. De-Power the MB4000 unit and then insert the microSD
card into the card holder. Power up the MB4000. The unit will detect that the microSD card has a firmware
and update file automatically. The Display will read [FIRMWARE UPDATE]. This takes approx 10 seconds.
Remove the card after the firmware is updated.
NB:- Do not leave the microSD card in the unit if it has a firmware update file.

SOFTWARE VERSIONS DONE


V8.1..........First release date 16/07/2013 MB4000_V1
V8.2..........Second release date 30/08/2013
* Minor bug fixes for the LCD sprint functions
* ASKDRX devices have been made for 8 devices
* Auto exit from Events menu after 30 seconds from no operation
* Reset of events can now be cleared from just typing the password
V8.3.........Updated keeloq sync counter
V8.4.........Updated Flash driver (bug fix)
V8.5.........Updated USB connection for the monitor GUI
V8.6.........Improved SPI routine, USB works only in routines test and standby routines
V9............New Feature added. Learning in Remotes and Text over the air using a SMS
message. A separate USB dongle reads the remote controls code. (Optional extra)

Sherlotronics SA (PTY) Ltd


251 Aintree Ave, Northriding
Commercial Park, Northriding
Randburg, Johannesburg
South Africa.
Tel: +27 (0)11 462-5101
Fax: +27 (0)11 462-8177
email: [email protected]
web: www.sherlotronics.co.za remote control at its best
Pg.11

You might also like