Systemair HHFlex

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

HHFlex Item number: #G1072

HHFlex Air Handling Units


Modular air handling solution that can be tailored
to any application. Ideal for hospitals, industry,
marine and offshore.
Innovative
Energy efficient
Robust
Tested and certified

Find more details in our online catalogue

Modular and customizable Certified performance


HHFlex air handling units have a modular platform design, enabling The HHFlex is independently tested and fully Eurovent certified. It is
you to tailor the unit to your project, based on required airflow and engineered with the requirements of hospitals and the pharmaceutical
specific demands. industry in mind, and of course hygiene certified.

High-quality components Wide range


The HHFlex is manufactured with high-quality components, including: More than 68 sizes are available to cover a range of 1.000 to 125.000
Heat recovery systems m³/h. Units can be:
Humidifiers Inside or outside
Filters Side-by-side, stacked, vertical or ceiling-mounted
Heat exchangers (heating and/or cooling) Delivery in sections or flat-packed
Sound attenuators

Article name: HHFlex | Product link: https://shop.systemair.com/en/productPermalink?p=143546 | Item number: G1072 | Document type: Product card | Created at: 2024-02-21
| Generated by: Systemair Online Catalogue | Language: English
Page 1 of 5
HHFlex Item number: #G1072

Certifications

AHU No: 20.11.009


Range: HH Flex

Eurovent Certified Performance HygienicByDesign

The HHFlex air handling unit offers virtually unlimited customization, making it suitable for nearly all applications. It is easy to install, commission, clean and
maintain. Reliable technology and sturdy panel and frame construction make the HHFlex a robust unit.
Filters are changed easily and quickly, and the large access doors facilitate easy inspection. High hygienic standards make the HHFlex suitable for health facilities
and the pharmaceutical industry. Strong corrosion resistance and ATEX explosion-proofing make the HHFlex suitable for use in marine and offshore, as well as
industrial applications.

Features

Panel construction Fans Filters


Rigid panels with 60 mm isolation. Model Both plug fans and centrifugal fans are Filters can be either slide-in or built-in.
box results (acc. EN1886): available. Fan selection is depending on Slide-in filters can be changed from the
Thermal bridging class TB2 the required flows and pressures. service side of the AHU; built-in filters
Thermal insulation class T2 Various motor types can be selected from require access through an inspection
Air leakage class L2 IE3 (AC with frequency converter) to IE5 section.
Deflection class D2 (EC motor with integrated speed control). Available filter types:
Filter bypass class F9 Panel filters
Bag filters
Panels in stainless steel are optional to Pleat filters
provide for maximum corrosion resistance. Carbon (cylinder) filters
HEPA filters
...

Dampers Rotary heat exchangers Plate heat exchangers


The dampers comply with tightness class 3 A rotary heat exchangers provides the A plate heat exchanger provides a heat
or higher (acc. EN 1751:2014). The heat recovery system with the shortest recovery system with separated airflows,
dampers have counter rotating length. They are available in three variants: preventing transfer of odors and moisture.
aerodynamically shaped damper blades Condensation Plate heat exchangers are available in two
made of aluminium, which ensure low Sorption hybrid (hygroscopic) variants:
pressure loss when open. Sorption Cross flow
Damper blades can be coated to provide Counter flow
additional protection. Rotary heat exchangers have an efficiency
up to 87%, depending on operating Both are made of aluminum. Cross flow
conditions. They recover both heat and has an efficiency of up to 85% depending
moisture. on air speed and unit size; counter flow
has an efficiency of up to 90%.
Plate heat exchangers are fitted with a by-
pass for capacity control and frost
protection. They also come with a built-in
sloped drip tray.

Article name: HHFlex | Product link: https://shop.systemair.com/en/productPermalink?p=143546 | Item number: G1072 | Document type: Product card | Created at: 2024-02-21
| Generated by: Systemair Online Catalogue | Language: English
Page 2 of 5
HHFlex Item number: #G1072

Run-around coils Heaters Coolers


Run-around coils, also called twin-coils, Heaters are used for heating the supply air Coolers are used for cooling the supply air
provide heat recovery when the two and come in four types: and come in two types:
airflows must be kept completely separate, Water coil Water coil
or when the airflows are in different places. DX coil DX coil
They have an efficiency of up to 80% Steam coil
depending on air speed through the coil. Electrical heating element Coils are made of copper tubes and
aluminum fins. In case of a water coil, the
Coils are made of copper tubes and coil is connected to a chiller or similar
aluminum fins. In case of a water or steam cooling system.
coil, the coil is connected to a heating or DX coils are used with heat pumps; in this
steam system. A frost protection case refrigerant runs through the heat
thermostat can be mounted. exchanger.
DX coils are used with heat pumps; in this
case refrigerant runs through the heat
exchanger.
Electrical heaters are equipped with a
safety thermostat and optional power
control.

Change-over and DX coils Humidifiers Sound attentuators


Change-over coils are used for heating or A humidifier is used to control the humidity The sound attenuator is an absorption
cooling of the supply air. There are two of the supply air. It is made as a complete attenuator with baffles and reduces the
types: unit including humidification elements, drip sound power level from the air handling
Water coils tray and frame made of stainless steel, as unit to the duct system. The baffles can be
DX coils well as the "generator" including all taken out for easy (dry or wet) cleaning.
accessories. Three humidifiers are
Coils are made of copper tubes and available:
aluminum fins. In case of a water coil, the Steam
coil is connected to a heating and/or Adiabatic
cooling system. A frost protection Infrasonic
thermostat can be mounted.
DX coils are used with heat pumps; in this
case refrigerant runs through the heat
exchanger.

Article name: HHFlex | Product link: https://shop.systemair.com/en/productPermalink?p=143546 | Item number: G1072 | Document type: Product card | Created at: 2024-02-21
| Generated by: Systemair Online Catalogue | Language: English
Page 3 of 5
HHFlex Item number: #G1072

Technical parameters
Dimensions and weights

Weight 1 kg

Article name: HHFlex | Product link: https://shop.systemair.com/en/productPermalink?p=143546 | Item number: G1072 | Document type: Product card | Created at: 2024-02-21
| Generated by: Systemair Online Catalogue | Language: English
Page 4 of 5
HHFlex Item number: #G1072

Documents
SYSTEMAIR_HHFLEX_E_DECEMBER_2020.PDF

Article name: HHFlex | Product link: https://shop.systemair.com/en/productPermalink?p=143546 | Item number: G1072 | Document type: Product card | Created at: 2024-02-21
| Generated by: Systemair Online Catalogue | Language: English
Page 5 of 5

You might also like