Wlsa Spemos
Wlsa Spemos
Components
C1 Power supply card
C2 NDE-measuring converter with two relay
C3 Relay I
C4 NTC-measuring converter
C5 Relay II
C1 C2 C3 C4 C5
Connections
Output ground: GND
Supply 18-40 VDC: +pin1, -pin2
DE speed sensor A: +pin7, ground pin8, signal pin9, shield pin14
DE speed sensor B: +pin10, ground pin11, signal pin12, shield pin14
DE speed meter: +pin18, ground pin19, shield pin 20
TC speed sensor B: signal pin22, ground pin24, shield pin21
TC speed meter A: +pin25, ground pin19, shield pin 20
TC speed sensor A: signal pin30, ground pin31, shield pin21
TC speed meter B: +pin35, ground pin19, shield pin 20
Output voltage: -pin43, +pin46
Speed meters
DE speed meter
TC speed meter A
TC speed meter B
Speed sensors
DE speed sensor A
DE speed sensor B
TC speed sensor A
TC speed sensor B
Components
F1: T 1.6 A fuse
D13: Supply voltage 18-40 VDC indication
R29: Output voltage +12 V adjust
R21: Output voltage -12 V adjust
Calibration
Adjust R29 to get +12,0 V from pin46.
Adjust R21 to get -12,0 V from pin43.
Components
D1: Engine run indication
P601: Engine run adjust
TP1: Engine run test point
D2: Voltage regulator connection indication
P602: Voltage regulator connection adjust
TP2: Voltage regulator connection test point
D3: Over speed indication
P603: Over speed adjust
TP3: Over speed test point
Calibration
Connect frequency generator ground to pin8 and signal to pin9 and pin12.
Adjust P601 to get “Engine run” V from TP1.
Set frequency to “Engine run” Hz to lit D1.
Adjust P602 to get “Voltage regulator connection” V from TP2.
Set frequency to “Voltage regulator connection” Hz to lit D2.
Adjust P603 to get “Over speed” V from TP3.
Set frequency to “Over speed” Hz to lit D3.
7 © Wärtsilä 15 May 2008 WLSA Spemos / Janne Räsänen
C4 NTC-measuring converter
Components
P701: Turbocharger A adjust
P711: Turbocharger B adjust
TP1: Turbocharger A speed 0-3000 Hz
TP2: Turbocharger A speed 0-10 VDC
TP3: Turbocharger B speed 0-3000 Hz
TP4: Turbocharger B speed 0-10 VDC
Calibration
Connect frequency generator ground to pin31 and signal to pin30 and pin22.
Set frequency to “Speed meter maximum” Hz.
Adjust P701 to get +10,0 V from TP2 and pin25.
Adjust P711 to get +10,0 V from TP4 and pin35.