LUGB Vortex Flow Meter
LUGB Vortex Flow Meter
, Ltd
Summary
LUGB type vortex flow meter is a kind of velocity flow meter, which is widely used in
petroleum, chemical, electric power, light industry, power heating industry. The
production and implementation standards of our company's vortex flow meter are
vortex flow sensor (JB/T9249-2015) and verification regulations for vortex flow
meter (JJG10299-2007).
Operating Principle
The vortex flow meter is composed of a vortex generator, a detection probe and corresponding electronic
circuits. When the fluid flows through the vortex generator, two alternating rows of vortices are formed on
both sides of it. This vortex is called the Karman vortex street. On the basis of the Karman vortex street theory,
Strohha proposed that the frequency of the Karman vortex street is proportional to the flow velocity of the
fluid, and gives the relationship between frequency and flow velocity
f = St × V/d
Formula:
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
These alternating vortices form a series of alternating fluid lift forces. The lift force acts on the detection
probe based on the piezoelectric effect to generate a series of alternating charge signals, which are
converted, shaped and amplified by the preamplifier. Output a pulse signal with the same frequency as the
Features:
1. No moving parts, long term stability, simple structure for easy installation and maintenance;
2. The output of sensor is pulse frequency, and its frequency is linear with the actual flow of the fluid being
measured. Zero point has no drift and performance is very stable. The structure is diverse, including
3. High accuracy, usually the measurement accuracy of liquid is ±1.0%; the measurement accuracy of gas is
±1.5%;
5. The pressure loss is small (about 1/4~1/2 of the orifice flow meter), which is an energy-saving flow
meter;
6. The installation method is flexible, according to the different process pipelines on site, it can be installed
7. It adopts noise cancellation circuit and anti-vibration sensor, which has certain anti-environmental
vibration performance;
8. Using ultra-low power consumption single-chip microcomputer technology, one 3V10AH lithium battery
10. Use EEPROM to protect the accumulated flow from power failure, and the protection time is more than
10 years.
Application
The instrument can be widely used in large, medium and small pipeline water supply and drainage, industrial
circulation, sewage treatment, oil and chemical reagents and compressed air, saturated and superheated
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
Technical Parameters
Table 1 Technical Parameters
Medium and high velocity media such as steam, compressed air, coal gas,
Measured medium
liquid, etc.
Implementation standards Vortex flow sensor(JB/T9249-2015)
Inspection procedures Vortex flow meter(JJG10299-2007)
Instrument size (mm) and Flange connection type DN15-DN300
connection type Clamp connection type DN15-DN300
Liquid measurement: ±1%
Accuracy
Gas or vapor measurement:±1%、±1.5%
Range ability 1:10;1:15;1:20
Sensor material SS304, SS316 etc
Medium temperature: -40~+70℃ ;-40~+250℃ ;-40~+350℃
Ambient temperature: -20~+60℃
Working condition
Relative humidity: 5%~90%
Atmospheric pressure: 86~106kPa
Output signal Pulse signal, 4 ~ 20mA signal
Communication output
RS485 communication, HART protocol
function
External power supply: +24VDC±15%,ripple ≤±15%, suitable for 4-20mA
output, pulse output, RS485, etc.
Power supply
Internal power supply: 1 set of 3.0V10AH lithium battery, the battery
voltage can work normally at 2.0V~3.0V.
Flange standard Normal standard GB/T 9113-2000
International
Flange standard For example: DIN, ANSI, JIS
Other standard
standard China
Flange standard For example: HG, JB
standard
Signal line interface M20×1.5 female thread(NPT thread needs to be customized)
Explosion-proof ExdIICT6 Gb
Ingress protection IP65 or higher(can be customized)
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
Liquid
Instrument Gas measurement
measurement Connection type Pressure rating
size(mm) range (m3/h)
range (m3/h)
Flange clamping/flange
15 1.2~6.2 5~25 2.5/1.6
connection
Flange clamping/flange
20 1.5~10 8~50 2.5/1.6
connection
Flange clamping/flange
25 1.6~16 10~70 2.5/1.6
connection
Flange clamping/flange
32 1.9~19 15~150 2.5/1.6
connection
Flange clamping/flange
40 2.5~26 22~220 2.5/1.6
connection
Flange clamping/flange
50 3.5~38 36~320 2.5/1.6
connection
Flange clamping/flange
65 6.2~65 50~480 1.6/1.6
connection
Flange clamping/flange
80 10~100 70~640 1.6/1.6
connection
Flange clamping/flange
100 15~150 130~1100 1.6/1.6
connection
Flange clamping/flange
125 25~250 200~1700 1.6/1.6
connection
Flange clamping/flange
150 36~380 280~2240 1.6/1.6
connection
Flange clamping/flange
200 62~650 580~4960 1.6/1.6
connection
Flange clamping/flange
250 140~1400 970~8000 1.6/1.6
connection
Flange clamping/flange
300 200~2000 1380~11000 1.6/1.6
connection
2. Volumetric flow rate for known standard conditions converted to operating conditions
The unit of measurement for common gases is the standard state volume unit of measurement, i.e. standard
cubic meters per hour (Nm3/h), referred to as "standard side". The standard state volume flow rate is
converted to the operating state volume flow rate by the following formula, i.e. cubic meter/hour (m3/h), and
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
Formula:
Q(w): The volume flow of the measured medium under working conditions. (M3/h)
Q(s): The volume flow of the measured medium under standard conditions. (Nm3/h, 20℃, 0.1013MPa
absolute pressure)
T 工: The temperature of the medium under the working condition
P 工: The pressure of the medium under the working condition, gauge pressure. (MPa)
3. For saturated steam, it can be selected according to the mass flow range given in Table.
4. For superheated steam, first check the density value of the corresponding temperature and pressure
(take absolute pressure: gauge pressure + 1) against the superheated steam table (table 4), and then
calculate the corresponding value according to the given mass flow through the following formula The
volume flow rate is compared with the steam flow rate of the corresponding caliber (Table 2)
G (kg/h)
Q(m 3 /h )
(kg/m3 )
Absolute pressure
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 1.3
Mpa
Temperature ℃ 120 133 144 152 159 165 170 175 180 184 189 192
Density Kg/m3 1.13 1.65 2.16 2.67 3.17 3.67 4.16 4.65 5.15 5.64 6.13 6.61
Qmin 6 8 11 13 16 18 21 23 26 28 31 33
DN15
Qmax 28 41 54 67 79 92 104 116 129 141 153 165
Qmin 9 13 17 21 25 29 33 37 41 45 49 53
DN20
Qmax 57 83 108 134 159 184 208 233 258 282 307 331
Qmin 11 17 22 27 32 37 42 47 52 56 61 66
DN25
Qmax 79 116 151 187 222 257 291 326 361 395 429 463
DN32 Qmin 17 25 32 40 48 55 62 70 77 85 92 99
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
Qmax 170 248 324 401 476 551 624 698 773 846 920 992
Qmin 57 83 108 134 159 184 208 233 258 282 307 331
DN65
Qmax 542 792 1037 1282 1522 1762 1997 2232 2472 2707 2942 3173
Qmin 79 116 151 187 222 257 291 326 361 395 429 463
DN80
Qmax 723 1056 1382 1709 2029 2349 2662 2976 3296 3610 3923 4230
Qmin 147 215 281 347 412 477 541 605 670 733 797 859
DN100
Qmax 1243 1815 2376 2937 3487 4037 4576 5115 5665 6204 6743 7271
Qmin 226 330 432 534 634 734 832 930 1030 1128 1226 1322
DN125
Qmax 1921 2805 3672 4539 5389 6239 7072 7905 8755 9588 10421 11237
Qmin 316 462 605 748 888 1028 1165 1302 1442 1579 1716 1851
DN150
Qmax 2543 3713 4860 6008 7133 8258 9360 10463 11588 12690 13793 14873
Qmin 655 957 1253 1549 1839 2129 2413 2697 2987 3271 3555 3834
DN200
Qmax 5605 8184 10714 13243 15723 18203 20634 23064 25544 27974 30405 32786
Qmin 1096 1601 2095 2590 3075 3560 4035 4511 4996 5471 5946 6412
DN250
Qmax 9040 13200 17280 21360 25360 29360 33280 37200 41200 45120 49040 52880
Qmin 1559 2277 2981 3685 4375 5065 5741 6417 7107 7783 8459 9122
DN300
Qmax 12430 18150 23760 29370 34870 40370 45760 51150 56650 62040 67430 72710
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
Absolute
1.4 1.5 1.6 1.7 1.8 1.9 2 2.1 2.2 2.3 2.4 2.5
pressure Mpa
Temperature ℃ 195 198 201 204 207 209.8 212 214.8 217.2 219.5 221.8 223.9
Density Kg/m3 7.1 7.59 8.08 8.57 9.06 9.55 10.04 10.54 11.03 11.52 12.02 12.51
Qmin 36 38 40 43 45 48 50 53 55 58 60 63
DN15
Qmax 178 190 202 214 227 239 250 263 275 288 300 313
Qmin 57 61 65 69 72 76 80 84 88 92 96 100
DN20
Qmax 355 380 404 429 453 478 500 525 550 575 600 625
Qmin 107 114 121 129 136 143 150 158 165 173 180 188
DN32
Qmax 1065 1139 1212 1286 1359 1433 1500 1575 1650 1725 1800 1875
Qmin 156 167 178 189 199 210 220 231 242 253 264 275
DN40
Qmax 1562 1670 1778 1885 1993 2101 2200 2310 2420 2530 2640 2750
Qmin 256 273 291 309 326 344 360 378 396 414 432 450
DN50
Qmax 2272 2429 2586 2742 2899 3056 3200 3360 3520 3680 3840 4000
Qmin 355 380 404 429 453 478 500 525 550 575 600 625
DN65
Qmax 3408 3643 3878 4114 4349 4584 4800 5040 5280 5520 5760 6000
Qmin 497 531 566 600 634 669 700 735 770 805 840 875
DN80
Qmax 4544 4858 5171 5485 5798 6112 6400 6720 7040 7360 7680 8000
Qmin 923 987 1050 1114 1178 1242 1300 1365 1430 1495 1560 1625
DN100
Qmax 7810 8349 8888 9427 9966 10505 11000 11550 12100 12650 13200 13750
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
Qmin 1420 1518 1616 1714 1812 1910 2000 2100 2200 2300 2400 2500
DN125
Qmax 12070 12903 13736 14569 15402 16235 17000 17850 18700 19550 20400 21250
Qmin 1988 2125 2262 2400 2537 2674 2800 2940 3080 3220 3360 3500
DN150
Qmax 15975 17078 18180 19283 20385 21488 22500 23625 24750 25875 27000 28125
Qmin 4118 4402 4686 4971 5255 5539 5800 6090 6380 6670 6960 7250
DN200
Qmax 35216 37646 40077 42507 44938 47368 49600 52080 54560 57040 59520 62000
Qmin 6887 7362 7838 8313 8788 9264 9700 10185 10670 11155 11640 12125
DN250
Qmax 56800 60720 64640 68560 72480 76400 80000 84000 88000 92000 96000 100000
Qmin 9798 10474 11150 11827 12503 13179 13800 14490 15180 15870 16560 17250
DN300
Qmax 78100 83490 88880 94270 99660 105050 110000 115500 121000 126500 132000 137500
Temperature
Absolute 150 170 190 210 230 250 270 290 310 330 350 370
Pressure (Mpa)
0.1 0.52 0.49 0.47 0.45 0.43 0.42 0.4 0.39 0.37 0.36 0.35 0.34
0.15 0.78 0.74 0.71 0.68 0.65 0.62 0.6 0.58 0.56 0.54 0.52 0.51
0.2 1.04 0.99 0.95 0.91 0.87 0.83 0.8 0.77 0.75 0.72 0.7 0.68
0.25 1.31 1.24 1.19 1.13 1.08 1.04 1 0.97 0.93 0.9 0.87 0.85
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
0.3 1.58 1.5 1.43 1.37 1.31 1.25 1.21 1.16 1.12 1.08 1.05 1.02
0.4 2.12 2.01 1.92 1.83 1.75 1.65 1.62 1.56 1.5 1.47 1.4 1.36
0.5 2.67 2.54 2.41 2.3 2.2 2.11 2.03 1.95 1.88 1.81 1.75 1.7
0.8 4.4 4.17 3.94 3.74 3.57 3.41 3.27 3.15 3.03 2.92 2.82 2.73
1.1 6.13 5.83 5.53 5.24 4.97 4.75 4.54 4.36 4.19 4.04 3.9 3.77
1.4 7.88 7.52 7.15 6.79 6.43 6.11 5.84 5.6 5.38 5.18 4.99 4.83
1.7 9.85 9.37 9.25 8.41 7.94 7.52 7.17 6.86 6.58 6.33 6.1 5.78
2 11.63 11.1 10.57 10.04 9.51 8.97 8.54 8.14 7.81 7.5 7.22 6.96
2.5 15.19 14.45 13.72 12.98 12.24 11.5 10.88 10.35 9.89 9.48 9.11 8.78
3 18.42 17.57 16.72 15.88 15.04 14.18 13.34 12.64 12 11.51 11.05 10.63
3.5 22.7 21.57 20.44 19.31 18.23 17.05 15.92 15.02 14.26 13.85 13.03 12.62
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
4 27.16 25.75 24.33 22.91 21.5 20.08 18.66 17.5 16.55 15.75 15.05 14.44
4.5 30.39 28.92 27.45 25.98 24.51 23.04 21.57 20.1 18.93 17.96 17.13 16.4
5 35.42 33.63 31.83 30.04 28.24 26.45 24.65 22.86 21.42 20.25 19.26 18.41
6 43.9 41.75 39.6 37.45 35.3 33.15 31.01 28.86 26.71 25.05 23.7 22.56
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
6. When the medium to be measured is a liquid, to prevent cavitation and cavitation, the liquid pressure of
the sensor shall be in accordance with the following formula:
2 Flange clamping
Structure Z
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
F Split type
N ExdIICT6 Gb
Accuracy
E Non explosion-proof
N Regular
Pressure rating
H
High pressure (Negotiated)
(X)
Instrument
D K H ( mm ) d n Standard
Size L Bolt
Pressure
(mm) Pulse Intelligent (Number Specifications
(mm) (mm) (mm) (mm) Resistance
Output Type of
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
Type Holes)
15 180 95 65 415 440 14 4 M12x60 Φ18x1.5
20 180 105 75 420 445 14 4 M12x60 Φ25x2.5
25 180 115 85 425 450 14 4 M12x60 Φ32x3.5
32 180 140 100 435 460 18 4 M16x70 Φ39x3.5
40 180 150 110 435 455 18 4 M16x70 Φ48x4
50 180 165 125 460 480 18 4 M16x70 Φ59x4.5
65 200 185 145 470 500 18 4 M16x70 Φ74x4.5
80 200 200 160 490 520 18 8 M16x70 Φ89x4.5
100 200 220 180 515 545 18 8 M16x70 Φ109x4.5
125 220 250 210 535 560 18 8 M16x70 Φ134x4.5
150 220 285 240 570 595 22 8 M16x90 Φ159x4.5
200 220 340 295 625 650 22 12 M16x90 Φ219x9
250 250 405 355 685 710 26 12 M24x110 Φ273x11
300 300 460 410 710 735 26 12 M24x110 Φ325x12
Note:
① The above parameters are applicable to flanged vortex flowmeter with pressure rating of 1.6 MPa.
② Flanged vortex flowmeters are not equipped with pipe flanges and bolts when they leave the factory.
Users need to purchase them separately. The standard for connecting flanges is GB/TB9113-2000 raised
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
type Intelligent
Type
15 65 105 66 405 425 Φ18x1.5
20 65 100 80 320 340 Φ25x2.5
25 65 100 80 320 340 Φ32x3.5
32 65 100 80 320 340 Φ39x3.5
40 65 100 80 320 340 Φ49x4.5
50 65 105 90 330 350 Φ59x4.5
65 65 105 105 330 350 Φ74x4.5
80 65 105 120 360 380 Φ89x4.5
100 65 110 140 380 400 Φ109x4.5
125 65 110 165 405 425 Φ134x4.5
150 65 115 190 430 450 Φ159x4.5
200 100 150 240 480 500 Φ219x9
250 150 200 290 520 550 Φ273x11
300 160 255 340 580 600 Φ325x12
Note:
① The above parameters are all applicable to flange clamping type vortex flowmeters with a pressure
rating of 1.6MPa.
② Installation length L. Increase the length of the mating flange. The mounting flange is a special flange,
which has been equipped before leaving the factory. The standard of the mounting flange is the corporate
③ The structure of pipe butt welding type, threaded connection type, clamp connection type, fixed plug-in
type, ball valve plug-in type and the external dimensions of the high temperature type are subject to
④ Flowmeter installation flange adopts enterprise standard, or other national department or industry
standard or other national standard (American standard, German standard, Japanese standard, etc.) if you
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
Instrument Piping
K H d n
Size L D Bolt Specifications
(mm) (mm) (Number specifications (Outer diameter *
(mm) (mm) (mm) (mm)
of holes) thickness)
15 180 95 65 435 14 4 M12x60 Φ18x1.5
20 180 105 75 440 14 4 M12x60 Φ25x2.5
25 180 115 85 445 14 4 M12x60 Φ32x3.5
32 180 140 100 455 18 4 M16x70 Φ39x3.5
40 180 150 110 450 18 4 M16x70 Φ48x4
50 180 165 125 475 18 4 M16x70 Φ59x4.5
65 200 185 145 495 18 4 M16x70 Φ74x4.5
80 200 200 160 515 18 8 M16x70 Φ89x4.5
100 200 220 180 540 18 8 M16x70 Φ109x4.5
125 220 250 210 555 18 8 M16x70 Φ134x4.5
150 220 285 240 590 22 8 M16x90 Φ159x4.5
200 220 340 295 645 22 12 M16x90 Φ219x9
250 250 405 355 705 26 12 M24x110 Φ273x11
300 300 460 410 730 26 12 M24x110 Φ325x12
Note:
① The above parameters are applicable to flanged connection type vortex flowmeter with pressure
② Flanged vortex flowmeters are not equipped with pipe flanges and bolts when they leave the factory.
Users need to purchase them separately. The standard for connecting flanges is GB/T9113-2000
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
Note:
① The above parameters are all applicable to flange clamping vortex flowmeters with a pressure rating of
1.6MPa.
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
② Installation length L. Increase the length of the mating flange. The mounting flange is a special flange,
which is already equipped at the factory. The standard of the mounting flange is the corporate standard,
and it is recommended.
③ The above dimensions are for reference only when designing and selecting. The actual dimensions are
④ Pipeline butt-welding type, threaded connection type, clamp connection type, fixed plug-in type, ball
valve plug-in type structure and external dimensions, and high temperature type, temperature type
⑤ The flowmeter mounting flange adopts corporate standards, and can also adopt other national
department or industry standards according to user needs, or adopt other national standards (American
Standard, German Standard, Japanese Standard, etc.). If you need special standards, please indicate
when ordering.
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
Installation Requirements
1. Flowmeter Installation
Installation Diagram
① Make openings in the pipe as required by the opening size and position the openings to meet the
④ Remove the flowmeter, weld the flange as required, and clean all protrusions in the pipe.
Install the sealing gasket with the same diameter as the pipeline in the inner groove of the flange, and install
the flowmeter into the flange. The flow direction of the flowmeter should be the same as the direction of the
2. Installation Notes
① The flowmeter is best installed indoors. If it needs to be installed outdoors, measures should be taken to
② The flowmeter should be installed in places with strong magnetic interference, small space and
inconvenient maintenance.
③ The flowmeter should not be installed in places with high temperature, heat radiation from equipment,
or corrosive gas. If installation is required, heat insulation and ventilation measures must be taken.
④ The flowmeter should not be installed on the pipeline with mechanical vibration. If installation is
necessary, shock absorption measures must be taken. A hose transition can be installed, or a fixed pipe
support point and anti-vibration pad should be installed at the 2DN upstream and downstream of the
flowmeter.
⑤ The flowmeter should be removed after the flange and pipe spot welding position, and the flowmeter
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
⑥ Vortex flowmeter can measure liquid, gas and steam, but is not common between different media. The
same medium is divided into three specifications: low temperature, high temperature and extra high
⑦ When measuring liquids, it is important to ensure that the piping is filled with liquid so that the media
⑧ The flow meter can be installed at any 360 degree vertical direction along the pipe axis. Optimal
installation: low-temperature dielectric rod installed vertically on the ground; high-temperature dielectric
⑨ The flowmeter should be mounted on a long overhead pipe as far as possible, as the sagging pipe is
likely to cause seal leakage between the flowmeter and the flange. If installation is necessary, pipe
⑩ In piping used to measure steam, the instrument connecting rod should be uninsulated at least halfway
⑪ In order to facilitate observation and wiring, the meter head can be rotated 360 degrees in the original
position, after adjusting the position, tighten the lock nut. To prevent moisture from entering the
housing from the lock nut, the lock nut should be wrapped with waterproof tape to seal it if necessary.
⑫ The shielded cable connected to the flow meter should be routed away from strong electromagnetic
field interference and should never be laid together with the high-voltage cable. The shielded cable
should be as short as possible and not coiled to reduce the distribution inductance, and the maximum
length should not exceed 500 m. The shielded cable should be as short as possible and not coiled to
⑬ When wiring, first unscrew the case back cover and feed the signal wire through the waterproof
connector. Follow the wiring diagram for proper wiring. Tighten the waterproof connector and ensure
that the cable must be bent downward before entering the waterproof connector to ensure that water
does not enter the housing through the cable (as shown below).
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
straight pipe section, the upstream flow distribution is as undisturbed as possible, if there is a control and
throttling device is best installed in the downstream. The minimum upstream and downstream requirements
are as follows: upstream: 10DN (10 times the diameter); downstream: 5DN (5 times the diameter).
If there are elbows' shrinkage' expansion' valves, etc. upstream of the flowmeter, a longer straight section of
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346
Dandong TOP Electronics Instrument (Group) Co., Ltd
Note: Requirements for piping: The inner diameter of the piping upstream and downstream of the
installation point of the flowmeter shall be the same as the inner diameter of the flowmeter, which shall meet
The pipeline should be concentric with the flowmeter, coaxial deviation should not be greater than 0.05 DN.
Ordering Information
Please read this selection sample thoroughly and select the appropriate flowmeter for the fluid medium and
field requirements, and then provide the following information to the manufacturer.
Maximum working pressure, maximum working temperature, and minimum working temperature at
The common flow rate, maximum flow rate, and minimum flow rate of the fluid.
ADD/ No.10 Huanghai Street, Zhenxing District, Dandong, Liaoning, China P.C. / 118008 www.ddtop.com
E-MAIL / [email protected] SERVICE / +86-415-6227346