Lokfix Fosroc For Anchoring

Download as pdf or txt
Download as pdf or txt
You are on page 1of 91

Technical Submittal

LOKFIX

Al Gurg Fosroc CO.LLC


P O Box 657, Dubai U.A.E.
Tel : 04 2039699, Fax : 04 2859649
www.fosroc.com
CONTENTS

section 1 Submission Summary


Company Introduction
ISO Certification

section 2 Trade License


Compliance Statement

section 3 Technical Data Sheet


Method Statement

section 4 Material Safety Data Sheet

section 5 Independent Test Certification

section 6 Job references


Company Profile
SUBMISSION SUMMARY

Summary

Fosroc’s range of products offer the following key advantages :

• technology developed to match application criteria

• high durability - long service life

• full compatibility between systems

• excellent track record in Middle East conditions

In terms of this submission, points of note include the following :


• technical data sheet
• independent test certificates
• job references and approvals of previous applications

The other main benefits of choosing Fosroc include :

• products manufactured by an ISO 9002, quality-assured


manufacturer

• full range of complimentary products to ensure a compatible


system

• products manufactured, and fully supported, locally in the UAE

• experienced, local applicators available

• additional training available for main contractor’s supervisory staff


to ensure that the correct installation techniques are observed
throughout
constructive solutions

Al Gurg Fosroc
The company was founded as a joint venture in 1975 between HE Easa Saleh Al Gurg
and Fosroc International. Al Gurg Fosroc is the first construction chemicals company to
establish a manufacturing base in the region, and presently serves the markets of the
U. A. E., Kuwait, Bahrain, Oman and other Fosroc companies worldwide.
Fosroc is one of the world's leading manufacturers of advanced technology products for
the construction and refurbishment industries.
For over 45 years, Al Gurg Fosroc is widely recognised as the market leader in concrete
repairs and protection, in particular; and has built a substantial reputation in a wide
range of product fields: Admixtures - Concrete repair and protection - Joint fillers
and sealants -Waterproofing - Protective coatings - Surface treatments -
Waterstops - Grouts and anchors – Flooring – Electrochemical products and
services.
Fosroc's success is built on a powerful combination of market knowledge, technical
resource, manufacturing expertise and problem-solving capabilities. The company
follows a policy of detailed product research and development providing high quality
products and long-term solutions.
The company has been the first construction materials manufacturing company to
introduce specification and AutoCAD services.
Al Gurg Fosroc's products are guaranteed for quality, but they must be applied correctly
and consistently to benefit from a long service life. To ensure this success, Al Gurg
Fosroc has introduced a Contracts and Application Department. This ensures that the
technical product knowledge is transpired to the applicators and the availability of the
local technical support center ensures that the correct application techniques are
followed.
Al Gurg Fosroc's commitment to total quality management system had lead to ISO 9002
certification in December 1994 - the first construction chemicals company in the Gulf
region to achieve this prestigious award. To keep up with the present market demands,
Al Gurg Fosroc has chosen the policy of continuous improvement, which led to
ISO 9001:2015 certification.
Al Gurg Fosroc was awarded the ISO 14001 certification in 1996 making it the first
construction chemicals company and the third company in any sector in the Gulf region
to receive this award.
As a clear indication of continual improvement in safety, quality and environmental
standards, Al Gurg Fosroc was awarded the OHSAS 18001 certification in October
2004. Currently updated to ISO 45001:2018.
Al Gurg Fosroc has a state of the art production unit, which has an output exceeding
160,000 metric tons per annum.
www.fosroc.com

Al Gurg Fosroc LLC


Post Box 657, Dubai
United Arab Emirates telephone: fax: email:
(+9714) 2039699 (+9714) 2859649 [email protected]
www.fosroc. com
Registered Office: 215 Community, Street No. 13, Nad Al Hamar Road, Al Ramool Industrial Estate, Rashidiya, Dubai
ISO Certificate
Trade License
‫رخصة صناعية‬
‫‪Industrial License‬‬
‫تفاصيل الرخصة ‪License Details /‬‬
‫‪License No.‬‬ ‫‪300142‬‬ ‫رقم الرخصة‬

‫شركة القرق فوسروك (ذ‪ .‬م‪ .‬م)‬ ‫اسم الشركة‬


‫‪Company Name‬‬ ‫(‪AL GURG FOSROC CO. )L.L.C‬‬
‫شركة القرق فوسروك (ذ‪ .‬م‪ .‬م)‬ ‫السم التجارى‬
‫‪Trade Name‬‬ ‫(‪AL GURG FOSROC CO. )L.L.C‬‬

‫‪Legal Type‬‬ ‫(‪Limited Liability Company)LLC‬‬ ‫ذات مسئولية محدودة‬ ‫الشكل القانونى‬
‫‪Expiry Date‬‬ ‫‪09/03/2024‬‬ ‫تاريخ النتهاء‬ ‫‪Issue Date‬‬ ‫‪30/10/1974‬‬ ‫تاريخ الصدار‬

‫® ‪D&B D-U-N-S‬‬ ‫‪561643177‬‬ ‫الرقم العالمي‬ ‫‪Main License No.‬‬ ‫‪300142‬‬ ‫رقم الرخصة الم‬
‫‪No.‬‬
‫‪Register No.‬‬ ‫‪41541‬‬ ‫رقم السجل التجارى‬ ‫‪DCCI No.‬‬ ‫‪10278‬‬ ‫عضوية الغرفة‬

‫الطراف ‪License Members /‬‬


‫الحصص ‪Share /‬‬ ‫الصفة ‪Role /‬‬ ‫الجنسية ‪Nationality /‬‬ ‫السم ‪Name /‬‬ ‫رقم الشخص‪No./‬‬

‫مدير ‪Manager /‬‬ ‫الردن ‪Jordan /‬‬ ‫منار صلح سعيد جمهور‬ ‫‪496716‬‬
‫‪MANAR SALAH SAID JAMHOUR‬‬

‫نشاط الرخصة التجارية ‪License Activities /‬‬


‫‪Adhesives Manufacturing‬‬ ‫صناعة مواد اللصق‬
‫‪Construction Chemicals Manufacturing‬‬ ‫صناعة المواد الكيماوية لغراض البناء‬
‫‪Insulation Materials Manufacturing‬‬ ‫صناعة المواد العازلة‬
‫‪Fire Resistant & Retardant Materials Manufacturing‬‬ ‫صناعة المواد المقاومة والمانعة لنتشار الحريق‬
‫العنوان ‪Address /‬‬
‫‪Phone No‬‬ ‫‪971-4-6858606‬‬ ‫تليفون‬ ‫‪P.O. Box‬‬ ‫‪657‬‬ ‫صندوق بريد‬
‫‪Fax No‬‬ ‫‪971-4-2859649‬‬ ‫فاكس‬ ‫‪Parcel ID‬‬ ‫‪215-357‬‬ ‫رقم القطعة‬
‫‪Mobile No‬‬ ‫‪971-50-6407901‬‬ ‫هاتف متحرك‬ ‫البريد اللكتروني ‪Email /‬‬

‫ملك الشيخ مانع بن خليفه بن سعيد ال مكتوم ‪ -‬ام رمول ‪ P215-357UNIT7‬مستودع رقم‬

‫الملحظات ‪Remarks /‬‬


‫تغيير المدير ‪.10/3/2019‬‬
‫تم نقل الموقع بتاريخ ‪15/04/2019‬‬
‫(استيراد وتصدير) حسب انشطة الرخصه‬

‫‪Print Date‬‬ ‫‪10/03/2023‬‬ ‫‪12:45‬‬ ‫تاريخ الطباعة‬ ‫‪Receipt No.‬‬ ‫‪14890100‬‬ ‫رقم اليصال‬
‫يمكنك الن تجديد رخصتك التجارية من خلل الرسائل النصية القصيرة‪ ،‬أرسل رقم الرخصة إلى ‪( 6969‬دو‪/‬اتصالت) للحصول‬
‫على اذن الدفع‪.‬‬ ‫‪Get FREE access to‬‬
‫‪Zoho One for the first‬‬
‫‪Now you can renew your trade license by sending a text message )SMS(. Send your trade‬‬ ‫‪year‬‬
‫‪license number to 6969 )Du/ Etisalat( to receive payment voucher.‬‬ ‫احصل على زوهو ون مجانا (‬
‫للسنة الولى‬
‫‪Zoho.com/det‬‬

‫وثيقة إلكترونية معتمدة وصادرة بدون توقيع من دائرة القتصاد والسياحة في دبي ‪.‬لمراجعة صحة البيانات الواردة في الرخصة يرجي مسح رمزالستجابة السريعة‬
‫‪this is a certified e-document issued without signature by the department of Economy and Tourism .Kindly Scan the QR Code to‬‬
‫‪Verify the certificate‬‬
‫ملحق الشركاء‬
Partners
License Details / ‫تفاصيل الرخصة‬

D&B D-U-N-S ® ‫ الرقم العالمي‬License No. 300142 ‫رقم الرخصة‬


561643177
No.

License Partners / ‫اصحاب الرخصة‬

Share / ‫الحصص‬ Sr. No./‫مسلسل الشخص‬ Nationality / ‫الجنسية‬ Name / ‫السم‬


51.0000000% 530292 ‫ المارات‬/ United Arab Emirates ‫ عيسى صالح‬/ Easa Saleh Al Gurg Investments L L C
‫م‬.‫م‬.‫ذ‬.‫القرق للستثمارات ش‬
49.0000000% 4009 ‫ سويسرا‬/ Switzerland ‫فوسروك هولدينج اي جي‬

Print Date 10/03/2023 12:45 ‫تاريخ الطباعة‬ Receipt No. 14890100 ‫رقم اليصال‬
‫اتصالت) للحصول‬/‫ (دو‬6969 ‫ أرسل رقم الرخصة إلى‬،‫يمكنك الن تجديد رخصتك التجارية من خلل الرسائل النصية القصيرة‬
.‫على اذن الدفع‬ Get FREE access to
Zoho One for the first
Now you can renew your trade license by sending a text message )SMS(. Send your trade year
license number to 6969 )Du/ Etisalat( to receive payment voucher. ( ‫احصل على زوهو ون مجانا‬
‫للسنة الولى‬
Zoho.com/det

‫لمراجعة صحة البيانات الواردة في الرخصة يرجي مسح رمزالستجابة السريعة‬. ‫وثيقة إلكترونية معتمدة وصادرة بدون توقيع من دائرة القتصاد والسياحة في دبي‬
this is a certified e-document issued without signature by the department of Economy and Tourism .Kindly Scan the QR Code to
Verify the certificate
‫شهادة شهر قيد شركة فى السجل التجارى‬
‫‪Commercial Register‬‬
‫تفاصيل القــيد ‪Register Details /‬‬
‫‪Main Lice. Nr‬‬ ‫‪300142‬‬ ‫‪ Register No.‬رقم الرخصة الم‬ ‫‪41541‬‬ ‫رقم القيد‬

‫‪Company‬‬ ‫شركة القرق فوسروك (ذ‪ .‬م‪ .‬م)‬


‫‪Name‬‬ ‫(‪AL GURG FOSROC CO. )L.L.C‬‬
‫‪Legal Type‬‬ ‫الشكل القانونى‬
‫(‪Limited Liability Company)LLC‬‬ ‫ذات مسئولية محدودة‬
‫‪Expiry Date‬‬ ‫‪09/03/2024‬‬ ‫‪ Reg. Date‬تاريخ النتهاء‬ ‫‪07/03/1994‬‬ ‫تاريخ الصدار‬
‫‪D&B D-U-N-S‬‬ ‫®‬ ‫الرقم العالمي‬
‫‪No.‬‬ ‫‪561643177‬‬

‫تفاصيل راس المال ‪Capital Details /‬‬


‫‪Nominated‬‬ ‫‪3,000,000.0000‬‬ ‫السمى‬
‫‪Paid‬‬ ‫‪3,000,000.0000‬‬ ‫المدفوع‬
‫‪No. of Shares‬‬ ‫‪0.0000‬‬ ‫عدد السهم‬
‫‪Currency‬‬ ‫‪UAE Dirhams‬‬ ‫درهم اماراتي‬ ‫العملة‬

‫عنوان الرخصة ‪License Address /‬‬


‫مستودع رقم ‪ P215-357UNIT7‬ملك الشيخ مانع بن خليفه بن سعيد ال مكتوم ‪ -‬ام رمول‬

‫عنوان السجل التجاري ‪Commerce Address /‬‬

‫مستودع رقم ‪ P215-357UNIT7‬ملك الشيخ مانع بن خليفه بن سعيد ال مكتوم ‪ -‬ام رمول‬
‫أنشطة السجل ‪Register Activities /‬‬
‫‪Construction Chemicals Trading‬‬ ‫تجارة المواد الكيماوية لغراض البناء‬
‫‪Insulation Materials Manufacturing‬‬ ‫صناعة المواد العازلة‬
‫‪Construction Chemicals Manufacturing‬‬ ‫صناعة المواد الكيماوية لغراض البناء‬
‫‪Fire Resistant & Retardant Materials Manufacturing‬‬ ‫صناعة المواد المقاومة والمانعة لنتشار الحريق‬
‫‪Adhesives Manufacturing‬‬ ‫صناعة مواد اللصق‬

‫الفروع ‪Branches /‬‬


‫السم التجارى‬ ‫رقم الرخصة‬
‫‪Trade Name‬‬ ‫‪License No‬‬

‫شركة القرق فوسروك (ذ‪ .‬م‪ .‬م) (فرع)‬ ‫‪772820‬‬


‫(‪AL GURG FOSROC CO. )L.L.C( )BRANCH‬‬

‫‪Print Date‬‬ ‫‪10/03/2023‬‬ ‫‪12:45‬‬ ‫تاريخ الطباعة‬ ‫‪Receipt No.‬‬ ‫‪14890100‬‬ ‫رقم اليصال‬
‫يمكنك الن تجديد رخصتك التجارية من خلل الرسائل النصية القصيرة‪ ،‬أرسل رقم الرخصة إلى ‪( 6969‬دو‪/‬اتصالت) للحصول‬
‫على اذن الدفع‪.‬‬ ‫‪Get FREE access to‬‬
‫‪Zoho One for the first‬‬
‫‪Now you can renew your trade license by sending a text message )SMS(. Send your trade‬‬ ‫‪year‬‬
‫‪license number to 6969 )Du/ Etisalat( to receive payment voucher.‬‬ ‫احصل على زوهو ون مجانا (‬
‫للسنة الولى‬
‫‪Zoho.com/det‬‬

‫وثيقة إلكترونية معتمدة وصادرة بدون توقيع من دائرة القتصاد والسياحة في دبي ‪.‬لمراجعة صحة البيانات الواردة في الرخصة يرجي مسح رمزالستجابة السريعة‬
‫‪this is a certified e-document issued without signature by the department of Economy and Tourism .Kindly Scan the QR Code to‬‬
‫‪Verify the certificate‬‬
‫بيانات التصريح ‪Permit Details /‬‬
‫‪Permit Nr‬‬ ‫رقم التصريح‬
‫‪152365‬‬
‫‪Permit Type‬‬ ‫نوع التصريح‬
‫مستودع‬

‫‪Warehouse‬‬

‫‪Expiry Date‬‬ ‫‪09/03/2024‬‬ ‫تاريخ النتهاء‬ ‫‪Issue Date‬‬ ‫‪01/05/2013‬‬ ‫تاريخ الصدار‬
‫‪Description‬‬ ‫تصريح مستودع لتخزين البضائع‬ ‫شرح‬
‫رقم الرض ‪215-385 :‬‬
‫الموقع ‪ :‬أم الرمول‬
‫اسم المالك ‪ :‬عيسى صالح القرق‬
‫اسم الشركة ‪ :‬شركة القرق فوسروك ذ‪.‬م‪.‬م‬
‫المساحة ‪ 5390 :‬قدم مربع‬
‫‪Remarks‬‬ ‫مستودع للتخزين فقط وليس لمزاولة النشاط‬ ‫ملحظات‬

‫بيانات التصريح ‪Permit Details /‬‬


‫‪Permit Nr‬‬ ‫رقم التصريح‬
‫‪9000908‬‬
‫‪Permit Type‬‬ ‫نوع التصريح‬
‫إعلنات بارزة‬

‫‪Vertical Ads‬‬

‫‪Expiry Date‬‬ ‫‪09/03/2024‬‬ ‫تاريخ النتهاء‬ ‫‪Issue Date‬‬ ‫‪09/03/2012‬‬ ‫تاريخ الصدار‬
‫‪Description‬‬ ‫شركة القرق فوسروك‬ ‫شرح‬

‫‪Remarks‬‬ ‫ملحظات‬

‫بيانات التصريح ‪Permit Details /‬‬


‫‪Permit Nr‬‬ ‫رقم التصريح‬
‫‪9405095‬‬
‫‪Permit Type‬‬ ‫نوع التصريح‬
‫إعلنات السماء التجارية‬

‫‪Trade Name Sign Boards‬‬

‫‪Expiry Date‬‬ ‫‪09/03/2024‬‬ ‫تاريخ النتهاء‬ ‫‪Issue Date‬‬ ‫‪09/03/2011‬‬ ‫تاريخ الصدار‬
‫‪Description‬‬ ‫شركة القرق فوسروك ذم م‬ ‫شرح‬

‫‪Remarks‬‬ ‫تصميم رقم ‪13697‬‬ ‫ملحظات‬

‫‪Print Date‬‬ ‫‪10/03/2023‬‬ ‫‪12:45‬‬ ‫تاريخ الطباعة‬ ‫‪Receipt No.‬‬ ‫‪14890100‬‬ ‫رقم اليصال‬
‫يمكنك الن تجديد رخصتك التجارية من خلل الرسائل النصية القصيرة‪ ،‬أرسل رقم الرخصة إلى ‪( 6969‬دو‪/‬اتصالت) للحصول‬
‫على اذن الدفع‪.‬‬ ‫‪Get FREE access to‬‬
‫‪Zoho One for the first‬‬
‫‪Now you can renew your trade license by sending a text message )SMS(. Send your trade‬‬ ‫‪year‬‬
‫‪license number to 6969 )Du/ Etisalat( to receive payment voucher.‬‬ ‫احصل على زوهو ون مجانا (‬
‫للسنة الولى‬
‫‪Zoho.com/det‬‬

‫وثيقة إلكترونية معتمدة وصادرة بدون توقيع من دائرة القتصاد والسياحة في دبي ‪.‬لمراجعة صحة البيانات الواردة في الرخصة يرجي مسح رمزالستجابة السريعة‬
‫‪this is a certified e-document issued without signature by the department of Economy and Tourism .Kindly Scan the QR Code to‬‬
‫‪Verify the certificate‬‬
Dear Merchants, ،،،‫عزيزي التاجر‬
Kindly take the following instruction into high :‫يرجى اخذ التعليمات التالية بعين العتبار‬
consideration:
1. It is not allowed to change the location registered in the license to move to .‫ عدم القيام بتغيير موقع الترخيص والنتقال الى موقع اخر دون الحصول على موافقة الدائرة‬.1
another address unless DET approval is obtained.
2. The trade name on the signboard must conform to the name mentioned in ‫ ضرورة ان يكون السم التجاري المدون على اللفتة مطابق للسم المدون بالرخصة مع ضرورة‬.2
the license and typed in one size. .‫كتابته بحجم واحد‬
The trade name must be in both Arabic and English as follows: :‫الحرص على أن تكون اللفتة باللغتين العربية والنجليزية و بالشكل التالي‬
- The trade name in Arabic must be placed on the right hand side of the .‫ يكتب السم التجاري باللغة العربية في يمين اللفتة وباللغة النجليزية تجاه اليسار‬-
signboard whereas the English text on the left hand side.
- The Arabic text must be in same size of the English equivalent ‫ يكتب السم التجاري باللغة العربية بنفس حجم السم المكتوب باللغة النجليزية‬-
- The Arabic trade name must be placed above the English equivalent. ‫ يكتب السم التجاري باللغة العربية أعلى السم المكتوب باللغة النجليزية‬-
3. A commercial permit must be issued for additional signboards and for .‫ الحرص على استخراج تصريح للفتات الضافيه والعلمات التجارية على اللفتة‬.3
placing trademarks on the signboard. %50 ‫ عدم تظليل الواجهة أكثر من‬.4
4. Text must not occupy more than 50% of the signboard. .‫ بعد منتصف الليل ال بعد استخراج تصريح‬12:00 ‫ عدم العمل لساعات اضافية بعد الساعة‬.5
5. Shops operating hours must not exceed 12:00 am unless a permit is .‫ عدم اجراء التنزيلت او التصفيات او العروض الخاصه بدون تصريح‬.6
issued. .‫ عدم اجراء اي تعديل او تغيير بيانات الترخيص ال بعد الرجوع للدائرة‬.7
6. Discounts, sales or special offers must not be announces unless a permit .‫ اللتزام بكتابة السعار على السلع والبضائع‬.8
is issued. ‫ طباعة ووضع بطاقة حماية المستهلك (كن على حق واعرف حقوقك كمستهلك) في مكان بارز من‬.9
7. It is not allowed to apply any amendments or change the license details www.consumerrights.ae ‫موقع الدائرة‬
unless approved by DET. .‫ للمستهلك الحق في الحصول على فاتورة الشراء‬.10
8. Prices must be placed on products and goods. ‫ العلن عن سياسة البيع للمستهلك عبر وسيلة اعلن مناسبة شاملة (لعملية السترجاع او الستبدال‬.11
9. The Consumer Protection Card )Be Right and Know Your Consumer )‫او الصلح للسلع‬
Rights( must be typed and placed visibly above the DET website
www.consumerrights.ae ‫ أو التصال أو غير ذلك وعدم البيع بطريقة المناداه‬،‫ عدم الترويج عن منتج عن طريق المندوبين‬.12
10. Consumers have the right to receive a purchase receipt. ‫ استخراج تصريح لمستودعات التخزين الخاصة بالمنشأة المرخصة أو تصريح للمكاتب الضافية أو‬.13
11. Announce the sale policy to consumer through suitable applicable .‫الكشاك‬
channels )to clarify procedures for goods replacement, repair and refund(. .‫ يجب على المطاعم وضع قائمه الطعام باللغتين العربيه والنجليزيه‬.14
12. It is not allowed to promote products through agents, telephone calls, or .‫ يجب وضع واعتماد قائمة السعار الخاصة بالصالونات الرجالية والنسائية ووضعها في مكان بارز‬.15
other ways or yelling. %5 ‫ يجب ان تكون السعار المعلنه مشمولة القيمة المضافه‬.16
13. Permits must be issued for warehouses of licensed business or ‫ يجب عرض الفاتورة بشكل تفصيلي موضحا فيها القيمه الجماليه للسلع والخدمات وقيمة الضريبه‬.17
additional offices or kiosks. .‫المضافه‬
14. Restaurants must place a menu in both Arabic and English languages. .‫ عدم القيام بالترويج او البيع او العرض لية بضائع مقلدة أو مغشوشة‬.18
15. Place an approved price list for services provided by ladies and .‫ الحرص على تسجيل العلمه التجارية بوزارة القتصاد بهدف حمايتها‬.19
gentlemen salons at a visible area. ‫ يحق لدائرة القتصاد والسياحة في دبي إيقاف الترخيص أو إلغائه أو فرض الغرامات في حال عدم‬.20
16. The displayed price list should be inclusive of 5% VAT .‫اللتزام بالشروط و الحكام و مخالفة التشريعات في الدولة‬
17. Invoices must clearly reflect the total amount of the purchased goods,
services and VAT.
18. Avoid promoting or selling or displaying any counterfeited goods.
19. To protect trade marks, it must be registered by the Ministry of Economy.
20. The Department of Economy & Tourism in Dubai has the right to
suspend or cancel the license or impose fines in case of non-compliance
with the terms and conditions as well as violation of the legislation in the
UAE.

Print Date 10/03/2023 12:45 ‫تاريخ الطباعة‬ Receipt No. 14890100 ‫رقم اليصال‬
‫اتصالت) للحصول‬/‫ (دو‬6969 ‫ أرسل رقم الرخصة إلى‬،‫يمكنك الن تجديد رخصتك التجارية من خلل الرسائل النصية القصيرة‬
.‫على اذن الدفع‬ Get FREE access to
Zoho One for the first
Now you can renew your trade license by sending a text message )SMS(. Send your trade year
license number to 6969 )Du/ Etisalat( to receive payment voucher. ( ‫احصل على زوهو ون مجانا‬
‫للسنة الولى‬
Zoho.com/det

‫لمراجعة صحة البيانات الواردة في الرخصة يرجي مسح رمزالستجابة السريعة‬. ‫وثيقة إلكترونية معتمدة وصادرة بدون توقيع من دائرة القتصاد والسياحة في دبي‬
this is a certified e-document issued without signature by the department of Economy and Tourism .Kindly Scan the QR Code to
Verify the certificate
Technical data sheet
Fosroc Lokfix
(formerly known as Lokset) constructive solutions

Mix and place polyester resin anchoring grouts

Uses Description

High strength corrosion resistant heavy duty anchoring. The Lokfix range consists of pre-measured, two pack, fille
These anchors include bolts, tendons or dowels in drilled polyester resin grouts. The two components are polyester
or formed holes located in concrete masonry, brickwork or resin and a catalysed fille . The standard version, having
natural rock. longer gel times suited to hot weather working conditions,
comprises of Lokfix S80 for vertical downward holes and
Permanent installation of reinforcement starter bars, founda-
Lokfix P80 for horizontal and overhead holes
tion bolts, ballustrading, barriers and safety fences, railway
tracks, ground anchors for towers, cranes, dock sills etc.

Advantages
Typical semi-permanent fixin
 Ultra rapid strength gain
 Vibration resistant
 Corrosion resistant
 Tolerant of wet and damp conditions
 Can be placed underwater and in damp conditions
 Non expansive
 Pre-weighed components ensure consistent perfor-
mance of the grout

Typical permanent fixin

Figure 1: Threaded bar anchored with Lokfi

Figure 2: Hexagon headed bolt with removable nut and tie


bar anchored with Lokfix
Lokfi
chemical
anchor Threaded rod
to be cut at an
angle of 45°
Lokfi
Fosroc Lokfix

Technical support Table 1

Fosroc offers a comprehensive range of high performance, Minimum hole depth


high quality concrete repair and construction products. In
Characteristic concrete
addition, Fosroc offers a technical support package to speci-
strength (N/mm2): 20 25 30 > 40
fiers, end-users and contractors, as well as on-site technical
assistance in locations all over the world. Permitted concrete shear
stress using Type One Bar
Design criteria
(N/mm2): 1.8 2.0 2.2 2.5
Bar Yield Hole
The version of Lokfi grout to be used will depend upon ambi- diameter (tonnes) diameter
ent temperature and anchor conditions. (mm) Minimum hole depth (mm)
The high strength of the cured resin permits strong anchors 12 5.2 20 280 250 225 200
to be created. The ultimate bond strength developed depends 16 9.3 20 490 445 400 355
upon: 20 14.5 25 615 555 500 440
25 22.6 32 750 675 615 540
Strength of host material 32 37.0 38 1035 930 845 745
Length of resin bond to bar 40 57.8 45 1365 1225 1115 980
Hole preparation and formation
Properties
Type and dimension of bar
Typical results
The following formula may be used to determine the minimum
Gel time : @20°C 35 Minutes
depth of installation for Type 1 rebar bolts, to ensure the shear
: @ 30°C 20 Minutes
stress within the concrete is kept within the limits set out in BS
Compressive strength
8110.
BS 6319 part 2 1983 @23°C @35°C
Minimum hole 0.6Y . Pd21 0.15Yd21 1 hour : 60 N/mm2 70 N/mm2
= =
depth (mm) SPd2 4 Sd2 3 hours : 65 N/mm2 80 N/mm2
1 day : 75 N/mm2 100 N/mm2
where Y is characteristic yield strength of steel
3 days : 85 N/mm2 105 N/mm2
(460 N/mm2 )
7 days : 100 N/mm2 110 N/mm2
S is permitted shear stress in concrete (N/mm2)
Tensile strength
d1 is bar diameter (mm) BS 6319 part 7: 1985
d2 is hole diameter (mm) 7 days : 14 N/mm2
Flexural strength
This formula is used typically as shown in Table 1.
BS 6319 part 3 1990
7 days : 22 N/mm2

Lokfix - Page 2 of 4
Fosroc Lokfix

Specification clauses Cleaning

Where shown on the contract documents, the mix and place Any mixing drums, pumps etc should be cleaned within the
grout shall be Lokfix manufactured by Fosroc. It shall be used pot life of the grout. Fosroc Solvent 102 is recommended for
in accordance with the manufacturer’s current application this purpose.
instructions.
Limitations
The grout where shown on the drawings shall be a two com-
ponent polyester resin system. When fully cured it shall exhibit 1. At permanent operating temperatures above 40°C, creep
a compressive strength in excess of 90 N/mm2, a flexural of the cured grout may become significant
strength in excess of 20 N/mm2 and a tensile strength in ex-
2. Resin anchors should not be used where structural load
cess of 12 N/mm2 at 7 days.
bearing performances have to be maintained in anchors
The storage, handling and placement of the grout must be in subjected to fire conditions
strict accordance with the manufacturer’s instructions.
3. For use at temperatures below 5°C, seek advice from
Fosroc.
Application instructions

Hole preparation and formation Estimating

Three methods of hole formation are possible. Supply


Lokfix S80, P8 : 1 litre packs
1. Optimum performance of Lokfix grouts requires rough
sided, dust free holes. These can be made by using rotary
Volume of Lokfix grout required in ml for each 100 mm of
percussive drills followed by oil-free air or water flushing
bond length.
2. Diamond drilled holes should be underreamed.
Hole diameter Bolt diameter (mm)
3. Cast holes should be of inverse dovetail configur - (mm) 12 16 20 25 32 40
tion. If parallel sided holes are cast, they should be rough 20 25
enough to provide an adequate mechanical key.
25 50 40 25
Bar preparation 32 80 70 60 40

1. All bars should be deformed. This will ensure good bond 38 100 100 75 45
between the bar and the grout. 45 150 130 100 45

2. Bars should be degreased and any mill scale or flaky rust 50 180 150 90
removed. 62 280 225

Mixing These figures allow for a 25% wastage facto .

Only a complete pack of resin and catalysed filler should be Note: 200 mm bond length is the minimum recommended.
mixed in one operation. Mixing may be carried out manually or
If the anchor is in very old concrete, masonry or brickwork the
mechanically. When a smooth, even consistency is achieved,
wastage factor should be increased.
the grout is ready for use. It must be placed well within the gel
time of the grout. No of bolts/200 mm deep hole which can be fixed u -
ing a 1 litre pack of Lokfi
Placing
Hole diameter Bolt size (mm)
The mixed grout should be poured or pumped steadily into
(mm) 12 16 20 25 32 40
the prepared anchor holes. The anchor bar should then be
pressed into the hole to the required depth. Slight agitation of 20 20
the bar will greatly assist in achieving a complete bond. 25 10 12 20
32 6 7 8 12
The bar should be left undisturbed in the required position until
38 5 5 6 10
the grout has hardened fully.
45 3 3 5 10
50 2 3 3

Lokfix - Page 3 of 4
Fosroc Lokfix

Storage Additional Information

Shelf life Fosroc manufactures a wide range of complementary prod-


ucts which include :
All products have a shelf life of 12 months at or below 20°C
if kept in a dry store in the original, unopened packs. Avoid  waterproofing membranes & waterstops
storage of material under direct sunlight.
 joint sealants & filler board
If stored in tropical conditions the shelf life will be 6 months.
 cementitious & epoxy grouts
Storage conditions
 specialised flooring material
Store in dry conditions away from high temperatures and
Fosroc additionally offers a comprehensive package of prod-
high humidity. Keep away from sources of heat and naked
ucts specifically designed for the repair and refurbishment
flames
of damaged concrete. Fosroc’s ‘Systematic Approach’ to
concrete repair features the following :
Precautions
 hand-placed repair mortars
Health and safety
 spray grade repair mortars
Lokfix products and Fosroc Solvent 105 are flammable. Kee
away from sources of ignition - no smoking. In the event of  fluid micro-concrete
fire extinguish with C 2 or foam.
 chemically resistant epoxy mortars
Some people are sensitive to resins and solvents. Avoid
 anti-carbonation/anti-chloride protective coatings
contact with skin and eyes. Ensure adequate ventilation and
avoid inhalation of vapours. Wear suitable protective cloth-  chemical and abrasion resistant coatings
ing, gloves and eye/face protection. Barrier creams provide
For further information on any of the above, please consult
additional skin protection. Should accidental skin contact
your local Fosroc office - as belo .
occur, wash immediately with a resin removing cream, fol-
lowed by soap and water. In case of contact with eyes, rinse
immediately with plenty of water and seek medical advice -
do not induce vomiting.

For additional information see the relevant Material Safety

* Denotes the trademark of Fosroc International Limited



See separate data sheet

Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions for the Supply of
Goods and Service. All Fosroc datasheets are updated on a regular basis. It is the user’s responsibility to obtain the latest version.

Head Office
telephone: (+9714) 2039699 fax: (+9714) 2859649 email: [email protected]
Al Gurg Fosroc LLC
Regional office
Post Box 657, Dubai Abu Dhabi, Al Gurg Fosroc telephone: 673 1779 fax: 673 1449 email: [email protected]
Bahrain, YBA Kanoo telephone: 17738200 fax: 17732828 email: [email protected]
United Arab Emirates Kuwait, Boodai telephone: 4817618 fax: 4832124 email: [email protected]
Oman, Al Amana telephone: 24815080 fax: 24817554 email: [email protected]

www.fosroc.com

UAE/0332/10/G
Method statement
method statement constructive solutions

Lokfix

This method statement should be read in conjunction with the “Application criteria” section
of Lokfix data sheet. Please refer to the local Fosroc office for advice on selection of the
most appropriate product for your application.

High temperature working

It is suggested that, for temperatures above 35°C, the following guidelines are adopted as good
working practice:

(i) Store unmixed materials in a cool (preferably temperature controlled) environment, avoiding
exposure to direct sunlight.
(ii) Keep equipment cool, arranging shade protection if necessary. It is especially important to
keep cool those surfaces of the equipment which will come into direct contact with the
material itself.
(iii) Try to avoid application during the hottest times of the day.
(iv) Make sufficient material, plant and labour available to ensure that application is a continuous
process.

Equipment

It is suggested that the following list of equipment is adopted as a minimum requirement

Protective clothing : Protective overalls


: Good quality gloves, goggles and face mask
Preparation equipment : Electric or pneumatic breaker
: Hammer and chisel
Mixing equipment : 1 KW slow speed drill, 400 or 500 rpm, plus
Fosroc mixing paddle and mixing vessel,

Application - points of note

Fosroc operates a policy to encourage the use, where possible, of approved or licensed applicators.
This ensures that works are completed satisfactorily so that the long-term performance of the
materials is assured. For contractors who wish to apply the materials themselves Fosroc is also able
to offer technical assistance and training, either on-site or at its Training Centre in Dubai.

Al Gurg Fosroc
LLC
Post Box 657, Dubai telephone: fax: email:
United Arab Emirates (+9714) 2039699 (+9714) 2859649 [email protected]

www.fosroc.com Registered Office: 215 Community, Street No. 13, Nad Al Hamar Road, Al Ramool Industrial Estate, Rashidiya, Dubai
constructive solutions

Section B : Application Method

1.0 Surface Preparation.

Attention to full and proper preparation is essential to successful grouting.

Hole Preparation

1.1 Optimum performance of Lokfix grouts requires rough sided, dust free holes. These can be
made by rotary percussive drills followed by oil-free air or water flushing.

1.2 Diamond drilled holes should be underreamed.

1.3 Cast holes should be of inverse dovetail configuration. If parallel sided holes are cast, they
should be rough enough to provide an adequate mechanical key.

Bar Preparation

1.4 All bars should be deformed. This will ensure good bond between bar and grout.

1.5 The bars should be degreased and any mill scale or flaky rust removed.

2.0 Mixing

2.1 For best results a mechanically powered grout mixer should be used.

2.2 For small quantities of grout a slow speed drill (400/500 rpm) fitted with a high shear paddle
is acceptable, but mixing should be restricted to one pack at a time in a container of minimum
capacity 25 litres.

2.3 Under no circumstances should part packs be used, as this will change the resin : powder
ratio, adversely affecting material performance and automatically invalidating Fosroc’s
standard product guarantee.

Page 2 of 3
constructive solutions

3.0 Placing

3.1 The mixing grout should be poured or pumped steadily into the prepared anchor holes.

3.2 The anchor bar should then be pressed into the hole to the required depth. Slight agitation of
the bar will greatly assist in achieving a complete bond.

3.3 The bar should be left undisturbed in the required position until the grout has hardened fully.

3.4 Ensure that the grout is placed within its Gel time (Refer to the Data sheet)

4.0 Cleaning

4.1 Any mixing drums, pumps etc. should be cleaned within the pot life of the grout. Fosroc
Solvent 102 is recommended.

Section C : Approval and variations

This method statement is offered by Fosroc as a ‘standard proposal’ for the application of Lokfix. It
remains the responsibility of the Engineer to determine the correct method for any given application.

Where alternative methods are to be used, these must be submitted to Fosroc for approval, in
writing, prior to commencement of any work. Fosroc will not accept responsibility or liability for
variations to the above method statement under any other condition.

Page 3 of 3
MSDS
Revision date: 09/07/2015

SAFETY DATA SHEET


LOKFIX P80 BASE

SECTION 1: Identification of the substance/mixture and of the company/undertaking

1.1. Product identifier


Product name LOKFIX P80 BASE

Product number A1666001AE1

1.2. Relevant identified uses of the substance or mixture and uses advised against
Identified uses Polyester resin anchoring grout

1.3. Details of the supplier of the safety data sheet


Supplier Al Gurg Fosroc LLC
PO Box 657
Dubai
United Arab Emirates
+ 971 4 2858606

1.4. Emergency telephone number


Emergency telephone +97142039699 (08:00 to 16:30) // +971506258232 (16:30 to 08:00)GMT+4

SECTION 2: Hazards identification

2.1. Classification of the substance or mixture


Classification
Physical hazards Flam. Liq. 3 - H226

Health hazards Acute Tox. 4 - H332 Skin Irrit. 2 - H315 Eye Irrit. 2 - H319

Environmental hazards Not Classified

Human health Vapours and spray/mists in high concentrations are narcotic. Symptoms following
overexposure may include the following: Headache. Fatigue. Dizziness. Nausea, vomiting.
The product is irritating to eyes and skin.

Environmental The product is not expected to be hazardous to the environment.

Physicochemical The product is flammable. Heating may generate flammable vapours.

2.2. Label elements

Pictogram

Signal word Warning

Hazard statements H332 Harmful if inhaled.


H315 Causes skin irritation.
H319 Causes serious eye irritation.
H226 Flammable liquid and vapour.

1/8
Revision date: 09/07/2015

LOKFIX P80 BASE

Precautionary statements P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No
smoking.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove
contact lenses, if present and easy to do. Continue rinsing.
P370+P378 In case of fire: Use foam, carbon dioxide, dry powder or water fog to extinguish.
P403+P235 Store in a well-ventilated place. Keep cool.

Contains POLYESTER RESIN

2.3. Other hazards


None known.

SECTION 3: Composition/information on ingredients

3.2. Mixtures

POLYESTER RESIN 60-100%


CAS number: 100-42-5

Classification Classification (67/548/EEC or 1999/45/EC)


Flam. Liq. 3 - H226 Xn;R20. Xi;R36/38. R10.
Acute Tox. 4 - H332
Skin Irrit. 2 - H315
Eye Irrit. 2 - H319

The Full Text for all R-Phrases and Hazard Statements are Displayed in Section 16.
Composition comments The data shown are in accordance with the latest EC Directives.

SECTION 4: First aid measures

4.1. Description of first aid measures


General information Move affected person to fresh air and keep warm and at rest in a position comfortable for
breathing. Never give anything by mouth to an unconscious person. Get medical attention if
any discomfort continues.

Inhalation Move affected person to fresh air and keep warm and at rest in a position comfortable for
breathing. Keep affected person under observation. Get medical attention. Show this Safety
Data Sheet to the medical personnel.

Ingestion Never give anything by mouth to an unconscious person. Do not induce vomiting. Rinse
mouth thoroughly with water. Get medical attention if any discomfort continues.

Skin contact Remove affected person from source of contamination. Remove contaminated clothing. Wash
skin thoroughly with soap and water. Get medical attention if any discomfort continues.

Eye contact Remove any contact lenses and open eyelids wide apart. Remove any contact lenses and
open eyelids wide apart. Continue to rinse for at least 15 minutes. Continue to rinse for at
least 15 minutes. Get medical attention if any discomfort continues.

4.2. Most important symptoms and effects, both acute and delayed
General information Not available.

4.3. Indication of any immediate medical attention and special treatment needed
Notes for the doctor Treat symptomatically.

2/8
Revision date: 09/07/2015

LOKFIX P80 BASE

SECTION 5: Firefighting measures

5.1. Extinguishing media


Suitable extinguishing media Water spray, fog or mist. Carbon dioxide, powder or foam. Dry chemicals, sand, dolomite etc.

5.2. Special hazards arising from the substance or mixture


Specific hazards Not known.

5.3. Advice for firefighters


Protective actions during Wear positive-pressure self-contained breathing apparatus (SCBA) and appropriate protective
firefighting clothing.

SECTION 6: Accidental release measures

6.1. Personal precautions, protective equipment and emergency procedures


Personal precautions For personal protection, see Section 8.

6.2. Environmental precautions


Environmental precautions Avoid release to the environment.

6.3. Methods and material for containment and cleaning up


Methods for cleaning up Keep combustible materials away from spillage. Extinguish all ignition sources. Avoid sparks,
flames, heat and smoking. Ventilate. Absorb in vermiculite, dry sand or earth and place into
containers. Wash thoroughly after dealing with a spillage.

6.4. Reference to other sections


Reference to other sections For waste disposal, see section 13.

SECTION 7: Handling and storage

7.1. Precautions for safe handling


Usage precautions Avoid spilling. Avoid contact with skin and eyes.

7.2. Conditions for safe storage, including any incompatibilities


Storage precautions Store in tightly-closed, original container in a dry, cool and well-ventilated place.

Storage class Flammable liquid storage.

7.3. Specific end use(s)


Specific end use(s) The identified uses for this product are detailed in Section 1.2.

SECTION 8: Exposure Controls/personal protection

8.1. Control parameters


Occupational exposure limits
SILICA FUME
Long-term exposure limit (8-hour TWA): TLV - Threshold Limit Value 2.4 mg/m3 Resp. Dust

Ingredient comments WEL = Workplace Exposure Limits

8.2. Exposure controls

Protective equipment

3/8
Revision date: 09/07/2015

LOKFIX P80 BASE

Appropriate engineering Provide adequate ventilation. Avoid inhalation of vapours. Observe any occupational
controls exposure limits for the product or ingredients.

Eye/face protection Eyewear complying with an approved standard should be worn if a risk assessment indicates
eye contact is possible. The following protection should be worn: Chemical splash goggles or
face shield.

Hand protection Chemical-resistant, impervious gloves complying with an approved standard should be worn if
a risk assessment indicates skin contact is possible. It is recommended that gloves are made
of the following material: Polyvinyl chloride (PVC). Rubber (natural, latex).

Other skin and body Wear appropriate clothing to prevent any possibility of skin contact.
protection

Hygiene measures Do not smoke in work area. Wash hands at the end of each work shift and before eating,
smoking and using the toilet. Wash promptly if skin becomes contaminated. Promptly remove
any clothing that becomes contaminated. Use appropriate skin cream to prevent drying of
skin. When using do not eat, drink or smoke.

Respiratory protection No specific recommendations. Respiratory protection may be required if excessive airborne
contamination occurs.

SECTION 9: Physical and Chemical Properties

9.1. Information on basic physical and chemical properties


Appearance Liquid.

Colour Red. or Purple.

Odour Pungent.

Odour threshold Not available.

pH Not available.

Melting point Not applicable.

Initial boiling point and range 145°C @

Flash point 29 deg C°C

Evaporation rate Not available.

Evaporation factor Not available.

Flammability (solid, gas) Not available.

Upper/lower flammability or Not available.


explosive limits

Other flammability Not available.

Vapour pressure Not available.

Vapour density Not available.

Relative density 1.1 @ 20 deg C @ °C

Bulk density Not applicable.

Solubility(ies) Insoluble in water.

Partition coefficient Not available.

Auto-ignition temperature 490°C

4/8
Revision date: 09/07/2015

LOKFIX P80 BASE

Decomposition Temperature Not available.

Viscosity Not determined.

Explosive properties Not available.

Explosive under the influence Not available.


of a flame

Oxidising properties Not available.

9.2. Other information


Other information No information required.

Volatile organic compound This product contains a maximum VOC content of < 10 g/litre.

SECTION 10: Stability and reactivity

10.1. Reactivity
Reactivity Stable at normal temperatures and pressure.

10.2. Chemical stability


Stability Stable at normal ambient temperatures.

10.3. Possibility of hazardous reactions


Possibility of hazardous Stable at normal temperature and pressure conditions.
reactions

10.4. Conditions to avoid


Conditions to avoid Avoid excessive heat for prolonged periods of time.

10.5. Incompatible materials


Materials to avoid Not available.

10.6. Hazardous decomposition products


Hazardous decomposition Does not decompose when used and stored as recommended. Thermal decomposition or
products combustion may liberate carbon oxides and other toxic gases or vapours.

SECTION 11: Toxicological information

11.1. Information on toxicological effects


Acute toxicity - inhalation
ATE inhalation (gases ppm) 4,587.28

ATE inhalation (vapours mg/l) 11.21

ATE inhalation (dusts/mists 1.53


mg/l)

General information Prolonged and repeated contact with solvents over a long period may lead to permanent
health problems.

Inhalation Gas or vapour in high concentrations may irritate the respiratory system. Symptoms following
overexposure may include the following: Coughing.

Ingestion May cause discomfort if swallowed.

Skin contact Prolonged and frequent contact may cause redness and irritation.

5/8
Revision date: 09/07/2015

LOKFIX P80 BASE

Eye contact Vapour or spray in the eyes may cause irritation and smarting.

SECTION 12: Ecological Information

Ecotoxicity The product is not expected to be toxic to aquatic organisms.

12.1. Toxicity
Toxicity Not relevant.

12.2. Persistence and degradability


Persistence and degradability Not available.

12.3. Bioaccumulative potential


Bioaccumulative potential Not available.

Partition coefficient Not available.

12.4. Mobility in soil


Mobility Not available.

12.5. Results of PBT and vPvB assessment


Results of PBT and vPvB This substance is not classified as PBT or vPvB according to current EU criteria.
assessment

12.6. Other adverse effects


Other adverse effects Not available.

SECTION 13: Disposal considerations

13.1. Waste treatment methods


General information Waste should be treated as controlled waste. Dispose of waste to licensed waste disposal site
in accordance with the requirements of the local Waste Disposal Authority.

Disposal methods Dispose of waste to licensed waste disposal site in accordance with the requirements of the
local Waste Disposal Authority.

SECTION 14: Transport information

14.1. UN number
UN No. (ADR/RID) 1993

UN No. (IMDG) 1993

UN No. (ICAO) 1993

14.2. UN proper shipping name


Proper shipping name FLAMMABLE LIQUID, N.O.S. (POLYESTER RESIN (PRE ACCELERATED))
(ADR/RID)

Proper shipping name FLAMMABLE LIQUID, N.O.S. (POLYESTER RESIN (PRE ACCELERATED))
(IMDG)

Proper shipping name (ICAO) FLAMMABLE LIQUID, N.O.S. (POLYESTER RESIN (PRE ACCELERATED))

Proper shipping name (ADN) FLAMMABLE LIQUID, N.O.S. (POLYESTER RESIN (PRE ACCELERATED))

14.3. Transport hazard class(es)


ADR/RID class 3

6/8
Revision date: 09/07/2015

LOKFIX P80 BASE

ADR/RID subsidiary risk

ADR/RID label 3

IMDG class 3

IMDG subsidiary risk

ICAO class/division 3

ICAO subsidiary risk

Transport labels

14.4. Packing group


ADR/RID packing group III

IMDG packing group III

ICAO packing group III

14.5. Environmental hazards

Environmentally hazardous substance/marine pollutant


No.

14.6. Special precautions for user


EmS F-E, S-E

Emergency Action Code •3YE

Hazard Identification Number 30


(ADR/RID)

Tunnel restriction code (D/E)

14.7. Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code
Transport in bulk according to Not available.
Annex II of MARPOL 73/78
and the IBC Code

SECTION 15: Regulatory information

15.1. Safety, health and environmental regulations/legislation specific for the substance or mixture
National regulations The Chemicals (Hazard Information and Packaging for Supply) Regulations 2009 (SI 2009
No. 716).

Guidance Workplace Exposure Limits EH40.


CHIP for everyone HSG228.
Approved Classification and Labelling Guide (Sixth edition) L131.
Safety Data Sheets for Substances and Preparations.

15.2. Chemical safety assessment


No chemical safety assessment has been carried out.

SECTION 16: Other information

7/8
Revision date: 09/07/2015

LOKFIX P80 BASE

General information The user must be instructed in the proper work procedure and be familiar with the contents of
these instructions.

Revision comments NOTE: Lines within the margin indicate significant changes from the previous revision.

Revision date 09/07/2015

Revision

Hazard statements in full H226 Flammable liquid and vapour.


H315 Causes skin irritation.
H319 Causes serious eye irritation.
H332 Harmful if inhaled.

The information on this data sheet represents our current data and is reliable provided that the product is used under the
prescribed conditions and in accordance with the application specified on the packaging and/or in the technical guidance
literature. Any other use of the product which involves using the product in combination with any other product or any other
process is the responsibility of the user.

8/8
Revision date: 24/11/2015 Revision: 4-A Supersedes date: 09/07/2015

SAFETY DATA SHEET


LOKFIX S80 AND P80 FILLER

SECTION 1: Identification of the substance/mixture and of the company/undertaking

1.1. Product identifier


Product name LOKFIX S80 AND P80 FILLER

Product number A1666501AE1

1.2. Relevant identified uses of the substance or mixture and uses advised against
Identified uses Polyester resin anchoring grout

1.3. Details of the supplier of the safety data sheet


Supplier Al Gurg Fosroc LLC
PO Box 657
Dubai
United Arab Emirates
+ 971 4 2858606

1.4. Emergency telephone number


Emergency telephone +97142039699 (08:00 to 16:30) // +971506258232 (16:30 to 08:00)GMT+4

SECTION 2: Hazards identification

2.1. Classification of the substance or mixture


Classification
Physical hazards Not Classified

Health hazards Eye Irrit. 2 - H319 Skin Sens. 1 - H317

Environmental hazards Aquatic Acute 1 - H400

2.2. Label elements

Pictogram

Signal word Warning

Hazard statements H400 Very toxic to aquatic life.


H317 May cause an allergic skin reaction.
H319 Causes serious eye irritation.

Precautionary statements P273 Avoid release to the environment.


P280 Wear protective gloves/protective clothing/eye protection/face protection.
P302+P352 IF ON SKIN: Wash with plenty of water.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove
contact lenses, if present and easy to do. Continue rinsing.
P391 Collect spillage.

Contains BENZOYL PEROXIDE

1/9
Revision date: 24/11/2015 Revision: 4-A Supersedes date: 09/07/2015

LOKFIX S80 AND P80 FILLER

Supplementary precautionary P261 Avoid breathing vapour/spray.


statements P264 Wash contaminated skin thoroughly after handling.
P272 Contaminated work clothing should not be allowed out of the workplace.
P321 Specific treatment (see medical advice on this label).
P333+P313 If skin irritation or rash occurs: Get medical advice/attention.
P337+P313 If eye irritation persists: Get medical advice/attention.
P362+P364 Take off contaminated clothing and wash it before reuse.
P501 Dispose of contents/container in accordance with national regulations.

2.3. Other hazards


None known.

SECTION 3: Composition/information on ingredients

3.2. Mixtures

SILICA SAND 60-100%


CAS number: 14808-60-7 EC number: 238-878-4

Classification
Not Classified

SILICA SAND 10-30%


CAS number: 14808-60-7

Classification
Eye Irrit. 2 - H319
STOT SE 3 - H335

BENZOYL PEROXIDE 1-5%


CAS number: 000094-36-0 EC number: 202-327-6
M factor (Acute) = 10

Classification
Org. Perox. B - H241
Eye Irrit. 2 - H319
Skin Sens. 1 - H317
Aquatic Acute 1 - H400

The Full Text for all R-Phrases and Hazard Statements are Displayed in Section 16.

SECTION 4: First aid measures

4.1. Description of first aid measures


Inhalation Move affected person to fresh air and keep warm and at rest in a position comfortable for
breathing. Keep affected person under observation. Get medical attention. Show this Safety
Data Sheet to the medical personnel.

Ingestion Rinse mouth thoroughly with water. Give plenty of water to drink. Do not induce vomiting. Get
medical attention immediately. Keep affected person under observation.

Skin contact Remove contaminated clothing immediately and wash skin with soap and water. Get medical
attention if irritation persists after washing.

2/9
Revision date: 24/11/2015 Revision: 4-A Supersedes date: 09/07/2015

LOKFIX S80 AND P80 FILLER

Eye contact Do not rub eye. Rinse immediately with plenty of water. Remove any contact lenses and open
eyelids wide apart. Continue to rinse for at least 15 minutes. Get medical attention if irritation
persists after washing. Show this Safety Data Sheet to the medical personnel.

4.2. Most important symptoms and effects, both acute and delayed
General information Not available.

4.3. Indication of any immediate medical attention and special treatment needed
Notes for the doctor Not available.

SECTION 5: Firefighting measures

5.1. Extinguishing media


Suitable extinguishing media Use fire-extinguishing media suitable for the surrounding fire.

5.2. Special hazards arising from the substance or mixture


Specific hazards No data

5.3. Advice for firefighters


Special protective equipment Wear positive-pressure self-contained breathing apparatus (SCBA) and appropriate protective
for firefighters clothing.

SECTION 6: Accidental release measures

6.1. Personal precautions, protective equipment and emergency procedures


Personal precautions Avoid inhalation of dust. Use work methods which minimize dust production. Avoid contact
with eyes and prolonged skin contact. For personal protection, see Section 8.

6.2. Environmental precautions


Environmental precautions Collect and dispose of spillage as indicated in Section 13. Do not discharge into drains or
watercourses or onto the ground.

6.3. Methods and material for containment and cleaning up


Methods for cleaning up For waste disposal, see Section 13. Collect powder using special dust vacuum cleaner with
particle filter or carefully sweep into suitable waste disposal containers and seal securely.

6.4. Reference to other sections


Reference to other sections For personal protection, see Section 8.

SECTION 7: Handling and storage

7.1. Precautions for safe handling


Usage precautions Good personal hygiene procedures should be implemented. Avoid generation and spreading
of dust. Avoid inhalation of dust. Avoid contact with eyes and prolonged skin contact.
Mechanical ventilation may be required. Change contaminated clothing.

7.2. Conditions for safe storage, including any incompatibilities


Storage precautions To be stored out of reach of children in its original packaging in a dry place. The product
contains less than 2 mg chromate/kg dry cement, and this limit will not be exceeded for 12
months from the packing date stated on the packaging. Seal opened containers and use up
as soon as possible

Storage class Chemical storage.

7.3. Specific end use(s)


Specific end use(s) The identified uses for this product are detailed in Section 1.2.

3/9
Revision date: 24/11/2015 Revision: 4-A Supersedes date: 09/07/2015

LOKFIX S80 AND P80 FILLER

SECTION 8: Exposure Controls/personal protection

8.1. Control parameters


Occupational exposure limits
SILICA SAND
Long-term exposure limit (8-hour TWA): WEL 0,1 mg/m³
SILICA SAND
Long-term exposure limit (8-hour TWA): WEL 0,1 mg/m³
WEL = Workplace Exposure Limit

Ingredient comments WEL = Workplace Exposure Limits

8.2. Exposure controls

Protective equipment

Appropriate engineering Provide adequate ventilation. Avoid inhalation of dust. Observe any occupational exposure
controls limits for the product or ingredients.

Personal protection Personal protection equipment should be chosen according to the CEN standards and in
discussion with the supplier of the personal protective equipment. This product may present a
chromate (VI) allergy risk. It contains a chromate reducing agent, but users should wear
appropriate personal protective equipment.

Eye/face protection Wear tight-fitting, chemical splash goggles or face shield. (conform EN 166)

Hand protection Wear protective gloves. It is recommended that gloves are made of the following material:
Polyvinyl chloride (PVC). Rubber (natural, latex). The most suitable glove should be chosen in
consultation with the glove supplier/manufacturer, who can provide information about the
breakthrough time of the glove material. If signs of wear and tear are noticed then the gloves
should be replaced.

Other skin and body Wear appropriate clothing to prevent any possibility of skin contact.
protection

Hygiene measures This product contains silica sands.


The grain size distribution of silica sand present means that it is not classified as hazardous.
However, any respirable crystalline dust generated by secondary processing may may cause
health effects.
Prolonged and /or massive inhalation of respirable crystalline silica dust may cause lung
fibrosis, commonly referred to as silicosis. Principal symptoms of silicosis are cough and
breathlessness.
Occupational exposure to respirable crystalline silica dust should be monitored and controlled
Change contaminated clothing.

Respiratory protection Wear a suitable dust mask. Wear a respirator fitted with the following cartridge: Particulate
filter, type P2. (EN 149)

Environmental exposure Not available


controls

SECTION 9: Physical and Chemical Properties

9.1. Information on basic physical and chemical properties


Appearance Dusty powder.

4/9
Revision date: 24/11/2015 Revision: 4-A Supersedes date: 09/07/2015

LOKFIX S80 AND P80 FILLER

Colour Green.

Odour Odourless.

Odour threshold Not available.

pH Not available.

Melting point 1610°C

Initial boiling point and range Not available.

Flash point Not applicable.

Evaporation rate Not available.

Evaporation factor Not applicable.

Flammability (solid, gas) Not applicable.

Upper/lower flammability or Not applicable.


explosive limits

Other flammability Not applicable.

Vapour pressure Not applicable.

Vapour density Not applicable.

Relative density 1.4 @ °C

Bulk density Not available.

Solubility(ies) Insoluble in water.

Partition coefficient Not applicable.

Auto-ignition temperature >380°C

Decomposition Temperature Not available.

Viscosity Not available.

Explosive properties Inconclusive data.

Explosive under the influence Not determined for the product.


of a flame

Oxidising properties not established

9.2. Other information


Other information Not available.

SECTION 10: Stability and reactivity

10.1. Reactivity
Reactivity Strong oxidising agents.

10.2. Chemical stability


Stability Stable at normal ambient temperatures.

10.3. Possibility of hazardous reactions


Possibility of hazardous Hazardous polymerization will not occur.
reactions

10.4. Conditions to avoid

5/9
Revision date: 24/11/2015 Revision: 4-A Supersedes date: 09/07/2015

LOKFIX S80 AND P80 FILLER

Conditions to avoid Not relevant.

10.5. Incompatible materials


Materials to avoid Strong acids. Strong oxidising agents.

10.6. Hazardous decomposition products


Hazardous decomposition Does not decompose when used and stored as recommended.
products

SECTION 11: Toxicological information

11.1. Information on toxicological effects

Inhalation Dust may irritate the respiratory system. Symptoms following overexposure may include the
following: Coughing.

Ingestion Not likely, due to the form of the product. Ingestion may cause severe irritation of the mouth,
the oesophagus and the gastrointestinal tract.

Skin contact Irritating to skin.

Eye contact Irritating to eyes. Symptoms following overexposure may include the following: Redness.
Pain. Immediate first aid is necessary.

Acute and chronic health Frequent inhalation of dust over a long period of time increases the risk of developing lung
hazards diseases.

Toxicological information on ingredients.

BENZOYL PEROXIDE

Acute toxicity - oral

Acute toxicity oral (LD₅₀ 5,000.0


mg/kg)

Species Rat

ATE oral (mg/kg) 5,000.0

Acute toxicity - inhalation

Acute toxicity inhalation 24.3


(LC₅₀ dust/mist mg/l)

Species Rat

ATE inhalation 24.3


(dusts/mists mg/l)

SECTION 12: Ecological Information

Ecological information on ingredients.

SILICA SAND

Ecotoxicity The product is not expected to be hazardous to the environment.

12.1. Toxicity
Ecological information on ingredients.

BENZOYL PEROXIDE

6/9
Revision date: 24/11/2015 Revision: 4-A Supersedes date: 09/07/2015

LOKFIX S80 AND P80 FILLER

Acute aquatic toxicity

LE(C)₅₀ 0.01 < L(E)C50 ≤ 0.1

M factor (Acute) 10

12.2. Persistence and degradability


Persistence and degradability The product is not biodegradable.

12.3. Bioaccumulative potential


Partition coefficient Not applicable.

12.4. Mobility in soil


Mobility The product is insoluble in water.

12.5. Results of PBT and vPvB assessment


Results of PBT and vPvB No data available.
assessment

12.6. Other adverse effects


Other adverse effects Not available.

SECTION 13: Disposal considerations

13.1. Waste treatment methods


Disposal methods Dispose of waste to licensed waste disposal site in accordance with the requirements of the
local Waste Disposal Authority. Note that fully cured material is not considered as hazardous
waste.

SECTION 14: Transport information

14.1. UN number
UN No. (ADR/RID) 3077

UN No. (IMDG) 3077

UN No. (ICAO) 3077

UN No. (ADN) 3077

14.2. UN proper shipping name


Proper shipping name ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (CONTAINS BENZOYL
(ADR/RID) PEROXIDE)

Proper shipping name ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (CONTAINS BENZOYL
(IMDG) PEROXIDE)

Proper shipping name (ICAO) ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (CONTAINS BENZOYL
PEROXIDE)

Proper shipping name (ADN) ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (CONTAINS BENZOYL
PEROXIDE)

14.3. Transport hazard class(es)


ADR/RID class 9

ADR/RID subsidiary risk

ADR/RID classification code M7

7/9
Revision date: 24/11/2015 Revision: 4-A Supersedes date: 09/07/2015

LOKFIX S80 AND P80 FILLER

ADR/RID label 9

IMDG class 9

IMDG subsidiary risk

ICAO class/division 9

ICAO subsidiary risk

ADN class 9

Transport labels

14.4. Packing group


ADR/RID packing group III

IMDG packing group III

ADN packing group III

ICAO packing group III

14.5. Environmental hazards

Environmentally hazardous substance/marine pollutant

14.6. Special precautions for user


EmS F-A, S-F

ADR transport category 3

Emergency Action Code 2Z

Hazard Identification Number 90


(ADR/RID)

Tunnel restriction code (E)

14.7. Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code
Transport in bulk according to Not applicable.
Annex II of MARPOL 73/78
and the IBC Code

SECTION 15: Regulatory information

15.1. Safety, health and environmental regulations/legislation specific for the substance or mixture
National regulations Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18
December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of
Chemicals (REACH), establishing a European Chemicals Agency, amending Directive
1999/45/EC and repealing Council Regulation (EEC) No 793/93 and Commission Regulation
(EC) No 1488/94 as well as Council Directive 76/769/EEC and Commission Directives
91/155/EEC, 93/67/EEC, 93/105/EC and 2000/21/EC, including amendments.

8/9
Revision date: 24/11/2015 Revision: 4-A Supersedes date: 09/07/2015

LOKFIX S80 AND P80 FILLER

Guidance Workplace Exposure Limits EH40.


CHIP for everyone HSG228.
Approved Classification and Labelling Guide (Sixth edition) L131.
Safety Data Sheets for Substances and Preparations.

15.2. Chemical safety assessment


Not available.

SECTION 16: Other information

General information The user must be instructed in the proper work procedure and be familiar with the contents of
these instructions.

Revision comments NOTE: Lines within the margin indicate significant changes from the previous revision.

Revision date 24/11/2015

Revision 4-A

Supersedes date 09/07/2015

Hazard statements in full H241 Heating may cause a fire or explosion.


H317 May cause an allergic skin reaction.
H319 Causes serious eye irritation.
H335 May cause respiratory irritation.
H400 Very toxic to aquatic life.

The information on this data sheet represents our current data and is reliable provided that the product is used under the
prescribed conditions and in accordance with the application specified on the packaging and/or in the technical guidance
literature. Any other use of the product which involves using the product in combination with any other product or any other
process is the responsibility of the user.

9/9
Revision date: 12/02/2018 Revision: 4 Supersedes date: 19/10/2016

SAFETY DATA SHEET


LOKFIX S80 BASE

SECTION 1: Identification of the substance/mixture and of the company/undertaking

1.1. Product identifier


Product name LOKFIX S80 BASE

Product number 1670000AE1, 1670001AE1

1.2. Relevant identified uses of the substance or mixture and uses advised against
Identified uses Polyester resin anchoring grout

1.3. Details of the supplier of the safety data sheet


Supplier Al Gurg Fosroc LLC
PO Box 657
Dubai
United Arab Emirates
+ 971 4 2858606

1.4. Emergency telephone number


Emergency telephone +97142039699 (08:00 to 16:30) // +971506258232 (16:30 to 08:00)GMT+4

SECTION 2: Hazards identification

2.1. Classification of the substance or mixture


Classification (EC 1272/2008)
Physical hazards Flam. Liq. 3 - H226

Health hazards Skin Irrit. 2 - H315 Eye Irrit. 2 - H319 Repr. 2 - H361d STOT RE 1 - H372

Environmental hazards Aquatic Chronic 3 - H412

2.2. Label elements

Pictogram

Signal word Danger

Hazard statements H226 Flammable liquid and vapour.


H315 Causes skin irritation.
H319 Causes serious eye irritation.
H361d Suspected of damaging the unborn child.
H372 Causes damage to organs through prolonged or repeated exposure.
H412 Harmful to aquatic life with long lasting effects.

1/9
Revision date: 12/02/2018 Revision: 4 Supersedes date: 19/10/2016

LOKFIX S80 BASE

Precautionary statements P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No
smoking.
P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing.
Rinse skin with water or shower.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove
contact lenses, if present and easy to do. Continue rinsing.
P501 Dispose of contents/ container in accordance with national regulations.

Contains STYRENE

Supplementary precautionary P201 Obtain special instructions before use.


statements P202 Do not handle until all safety precautions have been read and understood.
P233 Keep container tightly closed.
P240 Ground and bond container and receiving equipment.
P241 Use explosion-proof electrical equipment.
P242 Use non-sparking tools.
P243 Take action to prevent static discharges.
P260 Do not breathe vapour/ spray.
P264 Wash contaminated skin thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P273 Avoid release to the environment.
P302+P352 IF ON SKIN: Wash with plenty of water.
P308+P313 IF exposed or concerned: Get medical advice/ attention.
P314 Get medical advice/ attention if you feel unwell.
P321 Specific treatment (see medical advice on this label).
P332+P313 If skin irritation occurs: Get medical advice/ attention.
P337+P313 If eye irritation persists: Get medical advice/ attention.
P362+P364 Take off contaminated clothing and wash it before reuse.
P370+P378 In case of fire: Use foam, carbon dioxide, dry powder or water fog to extinguish.
P403+P235 Store in a well-ventilated place. Keep cool.
P405 Store locked up.

2.3. Other hazards


This product does not contain any substances classified as PBT or vPvB.

SECTION 3: Composition/information on ingredients

3.2. Mixtures

STYRENE 30-60%
CAS number: 100-42-5 EC number: 202-851-5

Classification
Flam. Liq. 3 - H226
Acute Tox. 4 - H332
Skin Irrit. 2 - H315
Eye Irrit. 2 - H319
Repr. 2 - H361d
STOT RE 1 - H372
Aquatic Chronic 3 - H412

The Full Text for all R-Phrases and Hazard Statements are Displayed in Section 16.

SECTION 4: First aid measures

4.1. Description of first aid measures

2/9
Revision date: 12/02/2018 Revision: 4 Supersedes date: 19/10/2016

LOKFIX S80 BASE

Inhalation If aerosol or vapour is inhaled in high concentrations: Take the person into the fresh air and
keep him warm, let him rest; if there is difficulty in breathing, medical advice is required.

Ingestion Do not induce vomiting. Rinse the mouth with lukewarm water. If vomiting
should occur spontaneously, keep airway clear. Get medical attention.
Never give anything by mouth to an unconscious person.

Skin contact Wash skin thoroughly with soap and water. Take off immediately all contaminated clothing.
Get medical attention if symptoms are severe or persist after washing.

Eye contact Wash with plenty of water. Remove affected person from source of contamination. Continue
to rinse for at least 15 minutes. Get medical attention if any discomfort continues.

4.2. Most important symptoms and effects, both acute and delayed
Inhalation May cause respiratory irritation. May cause coughing and difficulties in breathing.

Ingestion May cause discomfort if swallowed. May cause discomfort if swallowed.

Skin contact Causes skin irritation.

Eye contact Causes serious eye irritation.

4.3. Indication of any immediate medical attention and special treatment needed
Notes for the doctor Treat symptomatically.

SECTION 5: Firefighting measures

5.1. Extinguishing media


Suitable extinguishing media Use foam, carbon dioxide or dry powder to extinguish.

5.2. Special hazards arising from the substance or mixture


Specific hazards Flammable liquid and vapour.

Hazardous combustion Toxic gases or vapours.


products

5.3. Advice for firefighters


Protective actions during Containers close to fire should be removed or cooled with water.
firefighting

Special protective equipment Wear positive-pressure self-contained breathing apparatus (SCBA) and appropriate protective
for firefighters clothing.

SECTION 6: Accidental release measures

6.1. Personal precautions, protective equipment and emergency procedures


Personal precautions Wear protective clothing as described in Section 8 of this safety data sheet.

6.2. Environmental precautions


Environmental precautions Do not discharge into drains or watercourses or onto the ground.

6.3. Methods and material for containment and cleaning up


Methods for cleaning up Absorb in vermiculite, dry sand or earth and place into containers. Containers with collected
spillage must be properly labelled with correct contents and hazard symbol. Dispose of
contents/container in accordance with local regulations.

6.4. Reference to other sections


Reference to other sections For waste disposal, see Section 13.

3/9
Revision date: 12/02/2018 Revision: 4 Supersedes date: 19/10/2016

LOKFIX S80 BASE

SECTION 7: Handling and storage

7.1. Precautions for safe handling


Usage precautions Avoid contact with skin and eyes. Avoid inhalation of vapours.

7.2. Conditions for safe storage, including any incompatibilities


Storage precautions Store in tightly-closed, original container in a dry, cool and well-ventilated place.

7.3. Specific end use(s)


Specific end use(s) The identified uses for this product are detailed in Section 1.2.

SECTION 8: Exposure Controls/personal protection

8.1. Control parameters


Occupational exposure limits
STYRENE
Long-term exposure limit (8-hour TWA): WEL 100 ppm 430 mg/m³
Short-term exposure limit (15-minute): WEL 250 ppm 1080 mg/m³
WEL = Workplace Exposure Limit

POLYESTER RESIN

DNEL Workers - Inhalation; Long term systemic effects: 85 mg/m³


Workers - Inhalation; Short term systemic effects: 289 mg/m³
Workers - Inhalation; Short term local effects: 306 mg/m³

STYRENE (CAS: 100-42-5)

DNEL Workers - Inhalation; Long term systemic effects: 85 mg/m³


Workers - Inhalation; Short term : 289 mg/m³
Workers - Dermal; Long term systemic effects: 406 mg/kg/day

8.2. Exposure controls

Protective equipment

Appropriate engineering Provide adequate general and local exhaust ventilation.


controls

Eye/face protection Wear tight-fitting, chemical splash goggles or face shield.

Hand protection Wear protective gloves made of the following material: Rubber, neoprene or PVC.

Other skin and body Wear appropriate clothing to prevent any possibility of skin contact.
protection

Respiratory protection Use an approved air purifying respirator with replaceable filter cartage comply with EN 140and
filter EN 141: Organic Vapour cartridge type A1

SECTION 9: Physical and Chemical Properties

9.1. Information on basic physical and chemical properties


Appearance Liquid.

Colour Pink. or Purple.

4/9
Revision date: 12/02/2018 Revision: 4 Supersedes date: 19/10/2016

LOKFIX S80 BASE

Odour Pungent, characteristic of styrene.

Odour threshold Not determined.

pH Not determined.

Initial boiling point and range Not determined.

Flash point 32°C

Evaporation rate Not determined.

Evaporation factor Not determined.

Upper/lower flammability or Not determined.


explosive limits

Vapour pressure Not determined.

Relative density 1.1-1.15 @ 25°C

Bulk density Not determined.

Solubility(ies) Immiscible with water.

Partition coefficient Not determined.

Auto-ignition temperature Not determined.

Decomposition Temperature Not determined.

Viscosity 500 cP @ 25°C

Explosive properties Not considered to be explosive.

Explosive under the influence Not considered to be explosive.


of a flame

Oxidising properties Does not meet the criteria for classification as oxidising.

9.2. Other information


Other information No data available.

SECTION 10: Stability and reactivity

10.1. Reactivity
Reactivity Stable at normal ambient temperatures and when used as recommended.

10.2. Chemical stability


Stability Stable at normal ambient temperatures.

10.3. Possibility of hazardous reactions


Possibility of hazardous None known.
reactions

10.4. Conditions to avoid


Conditions to avoid Avoid excessive heat for prolonged periods of time.

10.5. Incompatible materials


Materials to avoid Strong oxidising agents.

10.6. Hazardous decomposition products

5/9
Revision date: 12/02/2018 Revision: 4 Supersedes date: 19/10/2016

LOKFIX S80 BASE

Hazardous decomposition Strong oxidising agents. Thermal decomposition or combustion may liberate carbon oxides
products and other toxic gases or vapours.

SECTION 11: Toxicological information

11.1. Information on toxicological effects


Acute toxicity - inhalation
ATE inhalation (vapours mg/l) 31.47

Inhalation May cause irritation. May cause coughing and difficulties in breathing.

Ingestion May cause discomfort. May cause stomach pain or vomiting.

Skin contact Causes skin irritation.

Eye contact May cause severe eye irritation.

Toxicological information on ingredients.

STYRENE

Acute toxicity - dermal

Acute toxicity dermal (LD₅₀ 5,000.0


mg/kg)

Acute toxicity - inhalation

Acute toxicity inhalation 11.8


(LC₅₀ vapours mg/l)

Species Rat

ATE inhalation (vapours 11.8


mg/l)

Skin corrosion/irritation

Extreme pH irritation

Serious eye damage/irritation

Serious eye Causes serious eye irritation.


damage/irritation

Skin sensitisation

Skin sensitisation Not sensitising.

Carcinogenicity

Carcinogenicity Found to produce lung tumours in mice. These tumours are not considered relevant
to humans.

IARC carcinogenicity IARC Group 2B Possibly carcinogenic to humans.

Reproductive toxicity

Reproductive toxicity - Known reproductive toxicant based on animal evidence.


development

Specific target organ toxicity - single exposure

STOT - single exposure May cause respiratory irritation.

Target organs Respiratory system, lungs

6/9
Revision date: 12/02/2018 Revision: 4 Supersedes date: 19/10/2016

LOKFIX S80 BASE

Specific target organ toxicity - repeated exposure

Target organs Liver Respiratory system, lungs Central nervous system

Aspiration hazard

Aspiration hazard Aspiration into the lungs when swallowed or vomited may cause chemical
pneumonitis which can be fatal.

SECTION 12: Ecological Information

12.1. Toxicity
Ecological information on ingredients.

STYRENE

Acute aquatic toxicity

Acute toxicity - fish LC50, 96 hours: 13.09 mg/l, Fish

Acute toxicity - aquatic LC₅₀, 48 hours: 8.428 mg/l, Daphnia magna


invertebrates

Acute toxicity - aquatic EC₅₀, 96 hours: 5.901 mg/l, Algae


plants

12.2. Persistence and degradability


Ecological information on ingredients.

STYRENE

Persistence and The product is readily biodegradable.


degradability

12.3. Bioaccumulative potential


Partition coefficient Not determined.

Ecological information on ingredients.

STYRENE

Bioaccumulative potential Not expected to be bioaccumulative.

12.4. Mobility in soil


Mobility The product is immiscible with water and will sediment in water systems.

12.5. Results of PBT and vPvB assessment


Results of PBT and vPvB This product does not contain any substances classified as PBT or vPvB.
assessment

12.6. Other adverse effects


Other adverse effects None known.

SECTION 13: Disposal considerations

13.1. Waste treatment methods


General information Waste is classified as hazardous waste.

Disposal methods Dispose of waste product or used containers in accordance with local regulations

SECTION 14: Transport information

7/9
Revision date: 12/02/2018 Revision: 4 Supersedes date: 19/10/2016

LOKFIX S80 BASE

14.1. UN number
UN No. (ADR/RID) 2055

UN No. (IMDG) 2055

UN No. (ICAO) 2055

UN No. (ADN) 2055

14.2. UN proper shipping name


Proper shipping name STYRENE MONOMER, STABILIZED
(ADR/RID)

Proper shipping name (IMDG) STYRENE MONOMER, STABILIZED

Proper shipping name (ICAO) STYRENE MONOMER, STABILIZED

Proper shipping name (ADN) STYRENE MONOMER, STABILIZED

14.3. Transport hazard class(es)


ADR/RID class 3

ADR/RID classification code F1

ADR/RID label 3

IMDG class 3

ICAO class/division 3

ADN class 3

Transport labels

14.4. Packing group


ADR/RID packing group III

IMDG packing group III

ADN packing group III

ICAO packing group III

14.5. Environmental hazards

Environmentally hazardous substance/marine pollutant


No.

14.6. Special precautions for user


EmS F-E, S-D

ADR transport category 3

Emergency Action Code 3Y

Hazard Identification Number 39


(ADR/RID)

Tunnel restriction code (D/E)

14.7. Transport in bulk according to Annex II of MARPOL and the IBC Code

8/9
Revision date: 12/02/2018 Revision: 4 Supersedes date: 19/10/2016

LOKFIX S80 BASE

Transport in bulk according to Not applicable.


Annex II of MARPOL 73/78
and the IBC Code

SECTION 15: Regulatory information

15.1. Safety, health and environmental regulations/legislation specific for the substance or mixture
EU legislation Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18
December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of
Chemicals (REACH) (as amended).

15.2. Chemical safety assessment


No chemical safety assessment has been carried out.

SECTION 16: Other information

General information Only trained personnel should use this material.

Revision comments NOTE: Lines within the margin indicate significant changes from the previous revision.

Revision date 12/02/2018

Revision 4

Supersedes date 19/10/2016

SDS number 24488

Hazard statements in full H226 Flammable liquid and vapour.


H315 Causes skin irritation.
H319 Causes serious eye irritation.
H332 Harmful if inhaled.
H361d Suspected of damaging the unborn child.
H372 Causes damage to organs (Hearing organs) through prolonged or repeated exposure.
H372 Causes damage to organs through prolonged or repeated exposure.
H412 Harmful to aquatic life with long lasting effects.

This information relates only to the specific material designated and may not be valid for such material used in combination
with any other materials or in any process. Such information is, to the best of the company's knowledge and belief, accurate
and reliable as of the date indicated. However, no warranty, guarantee or representation is made to its accuracy, reliability or
completeness. It is the user's responsibility to satisfy himself as to the suitability of such information for his own particular use.

9/9
Test report
Job reference
Job References for Lokfix
Project Category Project Title, (Client) Product Application Site Location Main Contractor, Specifier/ Consultant Project Date
(Subcontractor)
Brdg. Sharaluddin Buiding at Al Basti & Mukta German Gulf/Dr. Wael 1993
Building- Housing- Houses Starte bar gorut for extra column Dubai
Garhoud Associates Hassan
Building- Commercial- Mina Zayed Fender Repairs Dowel bar anchors Abu Dhabi Costain Acer Freeman Fox 1996
Building- Commercial- Twin Tower Dubai Al Naboodah Laing Arkitecnik 1998
Building- Commercial- Complex Anchoring down bars for stiffners 1999
City Centre Complex Qatar Mannai Engineering Meinhardt Middle East
columns
Building- Commercial- Complex 1999
GETCO - City Centre Anchoring sealing joints Qatar QBEC Meinhardt Middle East
Building- Commercial- Al Sulaiti Tower Qatar GENCO Meinhardt Middle East Dec-99
Mysore Paper Mills, (Mysore Paper Torsteel Research Sep-00
Building- Industrial- Factory Rehabilitation of existing factory India, Bhadravathi
Mills) Foundation in India
Building- QVC Qatar CCIC Technip Sep-00
Building- Education- College National Institute of Design, RCC repair India, Gujarat Freyssinet, (Torsteel Structural Engineering Sep-01
(National Institute of Design) Research Foundation Research Centre
in India)
Tuen Mun CC213, (Kowioon Canton Hong Kong,Hong Mar-03
Transport- Railways- Station Anchoring HK Ace JV
Railway Corporation) Kong
Jan-04
Yanbu Trading Port Rehabilitation, Saudi Arabia,
Building- Commercial- Office Repair and maintenance work Global Sohaimy Al Rabiah Cowi
(Sea Port Administration) Yanbu
Building- Housing- Houses Oud Al Mateena Villas, (Dubai The specified database lookup Duabi Lootah building and Al Burj consultant Jul-05
Government (property dept.)) generated more than 65,000 bytes construction co.
of results, which is too large for
Notes to handle in this context.

Building- Leisure- Sports Asian Games Village (Athletes For white concrete,grey Qatar, Doha El Seif Contracting, Hill International & Jul-05
accommodation), (Ministry of concrete,aggregate-exposed finish to (Redco International Fedcon
Municipal Affairs) precast wall-panels(on white Precast Co.)
concrete face),which had marble-
chips as the coarse aggregates.Face
down casting.
Building- Housing- Flats AL Mas Tower, (Nakheel) Curing forconcrete and repair mortar Duabi Arabian Construction W S Atkins Aug-05
Company

Building- Industrial- Power Saudi Arabia, Gulf Contracting Feb-06


Haiwayh Gas Plant, (Aramco) Anchor and grout Aramco
Station Hawiyah company
Building- Historic Building Al Samaliah Isles, (Abu Dhabi Anchor Bolt Grouting,coating.tile Abu Dhabi Al Faraa Cont Al ain, Mar-06
Municipality) adhesive (Al Sabbah Modern
Gen.Cont)
Saudi Arabia, Mar-06
Building- Industrial- Factory Hawayah Gas Plant, (Aramco) Grout, adhesive T & G, (Gulf Elite) Aramco
Hawiyah
Improvement of Al Khail Road Gunal & Mapa Nov-08
Transport- Roadways- Polyester resin anchoring grout Dubai Cansult Maunsell LTD
Junctions (19 & 22), (RTA) Construction Co.
Deerab Tunnels, (Ministery of Saudi Arabia, Jan-09
Transport- Tunnels- Road Anchoring, grouting Al Kharafi Sons
Transport) Riyadh
Feb-09
DS 161 Pumping Station X and its
Water- Waste water- Sewerage Dubai Bin Hafeez
risin mains, (Dubai Muncipality)
KFU - Girls Collage of Sceince B 02, Saudi Arabia, Jul-09
Building- Education- College Anchoring, grout, waterproofing Abdullah Al Khudari
(KFU) Hofuf
Bridge in Tabuk-Madinah Road, Saudi Arabia, Jul-09
Transport- Bridges- Road Grout, anchoring, Sealant Al Omier Co
(Ministry of transportation) Madinah
Deerab Tunnels, (Ministery of Saudi Arabia, Mar-11
Transport- Tunnels- Road Grouting, anchoring Al Kharafi Sons
Transport) Riyadh
Saudi Arabia, Jun-11
Building- Commercial- Hotel Makarm Deplomatic Hotel, (Shiraco) Adhesive, sealant, anchor and grout Salmoc Shiraco
Riyadh
Saudi Arabia, Jul-11
Building- Industrial- Factory ITCC, (GOSI) Anchor and grout CCE Dar Al Riyadh
Riyadh
Saudi Arabia, Aug-11
Building- Commercial- Hotel Makarm Deplomatic Hotel, (Shiraco) Adhesive, anchor and grout Salmoc Dar Al Handasah
Riyadh
National Hospital, (Ministry of Curing compound, repairing, anchor Saudi Arabia, Aug-11
Building- Commercial- Medical Tarouk Khatib & Alami
Finance) and grout Riyadh
UAE Armed Forces Command of National Projects & Shaheen Engineering Dec-11
Building- Commercial- Office Achoring grout Abu Dhabi
Military Works Construction LLC Consultancy
Deerab Tunnels, (Ministery of Saudi Arabia, Jul-12
Transport- Tunnels- Road Grouting, anchoring Al Kharafi Sons
Transport) Riyadh
Jumeirah Park Villas, Package 5A Oct-13
Arabtec Construction
Building- Housing- Villas Const. of 134 No. Villas & Infra Achoring grout Dubai Dar Al Handasah
LLC
Works, (Jumeirah Park LLC)
Building- Housing- Houses Reem Development - Construction Mar-14
Arabtec Construction Bhans Engineering
of Mira Townhouses (Community Achoring grout Dubai
LLC Consultants
1,2,3 & 4), (Emaar)
Transport- Bridges- Road Maintenance of Bridges and its Anchoring Adhesive Grout Abu Dhabi Al Fahjan General Hyder Jul-14
Lighting in Al Ain City Trans. & Cont. Est.
Building- Housing- Houses Oct-14
Construction of New Guest House a Al Shafar Contracting
Abu Dhabi
Ruwais Oilfield LLC
Presidential Guard Command Dec-14
Non shrink repair mortar for Intermass Engg. &
Building- Commercial- Others Directorate of Logistic Project Abu Dhabi
grouting & anchoring Contg.
Management Department
Development of Dubai Wharf at Jan-15
Engineering
Building- Commercial- Others Culture Village Plot No. P1.E025, Achoring grout Dubai Lacasa
Contracting Co. LLC
Dubai, (Dubai Properties)
Border Post Complex at Al Aswad, Jan-15
Building- Commercial- Complex Polyester resin anchoring grout Oman Abu Hatim Co. LLC
(Royal Oman Police)
07-101 Sanctuary Falls, (Shaikh Arabtec Construction DSA Architects Mar-15
Building- Housing- Villas Polyester resin anchoring grout Dubai
Holdings) LLC Internationals
Ruwais Housing Complex Expansion Mar-16
Building- Education- School Phase lll Construction of New Polyster resin anchoring grouts Abu Dhabi ASGC
Secondary School at Ruwais
Airport Interchange and Airport
Parsons International
Transport- Roadways- Region Road Network (E10), Polyster resin anchoring grout Abu Dhabi Leighton Contracting Apr-16
Limited
(Department of Transport)
Badr Phase 1 On Plot No. 2615314 Heavy duty anchoring grout for May-16
Building- Commercial- at Muhaisnah First, Dubai, (Dubai permanent installation of Dubai ECC Lacasa
Islamic Bank) reinforcement starter bars
Building- Housing- Houses Development of Mohamed Bin Oct-16
Zayed City in Fujairah, Phase 1
Construction of 1100 Housing Units For high strngth corrosion resistant
Fujairah Arabtec Aecom
Icluding Roads, Infrastructure & heavy duty anchoring
Landscape Works, (Ministry of
presidential Affairs)
Building- Housing- Houses 2015-213-Fuj Construction and Jan-17
Infrastructure of 1100 - UAE Anchoring grout Dubai Arabtec
Nationals Housing Units
Masdar Institue Neighbourhood, Jul-17
Building- Commercial- Others Resin anchoring grouts Abu Dhabi Six Construct Aecom
(Masdar)
Aug-17
Main Contract Works Holiday Inn & Dhafir Development
Building- Commercial- Hotel All floors Dubai WME Consultants
Staybridge Suites, (Ishraq Dubai LLC Contracting LLC
Aug-17
Building- Commercial- Complex Dubai South Mall, (Emaar) Polyster resin anchoring grouts Dubai Arabtec Atkins
B+G+4P+27+Mech+Roof Hotel Nov-17
Ghantoot Gulf Al Hawraa Engineering
Building- Commercial- Hotel Building "The One", (First Home Polyster resin anchoring grouts Dubai
Contracting Co. Consultant
Limited)
Jan-18
R777/4B1 Entrance to the Jewel of Polyster resin based anchoring grout Afcons Construction
Transport- Roadways- Dubai Parsons Overseas Limited
the Creek Development, (RTA) forfixing rebar, dowel and anchors Mideast
1486A/58 2B+G+3F+R Aster Hospital Apr-18
High strength corrosion heavy duty Belhasa Engineering
Building- Commercial- Medical On Plot No.1182 at Bu Daniq, Sharjah Arif & Bintoak
anchoring for dowels and Contracting
Sharjah, (Aster Hospital)
Epoxy grouting material for rebar Jun-18
Building- Housing- Villas Nudra Beach Villas - Saadiyat Abu Dhabi Wates/Eastern JV PMK Consult
fixing
Job References for Lokfix PS80
Project Category Project Title, (Client) Product Application Site Location Main Contractor, Specifier/ Consultant Project Date
(Subcontractor)

Building- Commercial- Hospital Rustaq Hospital Rustaq Yahya Costain Khatib & Alami 1992

Building- Industrial- Power Gubrah Desert Plant Muscat, Oman Takoos Beston Engineering Science 1992
Station
Building- Housing- Others Brdg. Sharaluddin Building at Starter bar grout for extra Dubai Al Basti & Mukhta German Gulf / Dr. 1993
Garhoud column Associates Wael Hussan

Building- Industrial- Factory Mina Zayed Fender Repairs Dowel bar anchors Abu Dhabi Costain Acer Freeman Fox 1996

Building- Housing- Flats Twin Tower Dubai Al Naboodah Laing Arkitecnik 1998

Building- Commercial- Shops City Centre Complex Anchoring down bars for Qatar Mannai Meinhard Middle 1999
stiffers columns Engineering East
Building- Commercial- Shops GETCO - City Centre Anchoring sealing joints Qatar QBEC Meinhard Middle 1999
East
Building- Housing- Flats Al Sulaiti Tower Qatar Genco Meinhard Middle Dec-99
East
Building- Industrial- Factory QVC Lokset Qatar CCIC Technip Sep-00

Transport- Tunnels- Road Dubai International Airport Poads Floor and wall protection for Dubai Al Ghandi CCC - Parsons Delew Dec-03
Improvements Phase ll Expansion - the side walk ot the tunnels Cather Overseas
Nadd Al Hammar / Beirut Road Limited
Tunnel, (Dubai Municipality)

Transport- Terminals- Air Dubai Airwing Facilities AX151, Repair, grouts Dubai Al Ghandi CCC - Dar Al Handasah Apr-04
(Dubai Civil Aviation) DBB JV
Building- Housing- Flats Dubai Festival City - Z 10P020, Tile adhesive at tile grout Dubai Al Naboodah May-06
(Dubai Festival City) Cont.
Transport- Terminals- Ferry Sihanouvilla Jetty, (Public Work Jetty Vietnam, Phnom Penta Ocean. Penta Ocean Jun-06
Dept. Cambodia) Peng Japan, (CCW)
Building- Industrial- Factory Burj Duai Development, District Protection to floors Dubai Trans Gulf Electro GHD Oct-06
Cooling Plant #3, (Emaar Mechanical, (Al
Properties) Naboodah Cont)

Transport- Bridges- Road La Villa Contemporaine Business Dubai Al Naboodah Halcrow Dec-06
Bay Phase 1 & 2, Infrastructure Engineering
Works Package, (Dubai Properties) Services
Building- Commercial- Office Latifa Tower, (Private Owend) Bathrooms Dubai Al Rostamani Arkiplan Jan-08
Pegel
Building- Housing- Flats Delta 1 & 2, (Delta Properties) Repairs, pilehead treatment Dubai Engineering National Engineering Jul-08
Contracting Bureau
Company
Job References for Lokfix S80
Project Category Project Title, (Client) Product Application Site Location Main Contractor, Specifier/ Consultant Project Date
(Subcontractor)

Transport- Roadways- Al Ain Municipality - Internal Al Ain Griffin Traffic W S Atkins Sep-98
Roads in Hariya
Building- Industrial- Factory Sharjah Cement Co Grouting, dwydag anchors Sharjah Swiss Boring Sharjah Cemenr 1991
Company
Building- Golf Marina & Gold Course Dubai Dowelling of copinf units Dubai Al Naboodah Halcrow Intl 1991
Municipality
Transport- Jebel Ali Port Jebel Ali Overseas AST 1994
Water- Marine- Docks Arab Ship Building & Repair Yard Dry dock repairs Bahrain, Bahrain Mohammed Jalal Cowi Al Moayed Jul-04
Bahrain, (Asry) Contracting

Building- Housing- Flats Al Mas Tower, (Nakheel) Curing for concrete and repair Dubai Arabian W S Atkins Aug-05
mortar Construction
Company
Building- Historic- Building Al Samaliah Isles, (Abu Dhabi Anchor bolt grouting, coating, Abu Dhabi Al Faraa Cont Al Mar-06
Municipality) tile adhesive Ain, (Al Sabbah
Modern Gen.
Cont)
Water- Marine- Piers Al Jeer Fishing Harbor, (Ports The specified database lookup Al Jeer Athena Hellenic Gibb's Consultant Aug-06
Authority) generated more than 65000 Eng. & Tourist Co. Office
bytes of results, which is too
large for notes to handle in this
context
Water- Marine- Piers RAK Port Development, (Ports The specified database lookup Ras Al Khamiah Athena Hellenic Gibb's Consultant Aug-06
Authority) generated more than 65000 Eng. & Tourist Co. Office
bytes of results, which is too
large for notes to handle in this
context
Building- Commercial- Hotel Mina Al Arab RAK, (RAK The specified database lookup RAK Chaina Harbour Halcrow Oct-06
Properties) generated more than 65000 Eng. Cont
bytes of results, which is too
large for notes to handle in this
context
Building- Commercial- Office Etisalat HorAl Anz, (Etisalat UAE) All kinds of construction Dubai Seidco General Oct-06
material grouts, anchoring, Contracting
adheisive, concrete repair and
flooring
Transport- Bridges- Road Ras Al Khor Interchange, (RTA) The specified database lookup Dubai Dutco Balfour Parsons Dec-06
generated more than 65000 Beatty LLC
bytes of results, which is too
large for notes to handle in this
context
Building- Industrial- Power Pot Line 6 - Dubal, (Dubal) Bonding of concrete Dubai Al Futtaim Feb-07
Station Carrilion
Transport- Terminals- Freight Jabal Ali New ontainer Terminal,Grouting under sole plate of Dubai Hyundai, Scot Wilson Kirk Feb-07
(Jebel Ali Free Zone) gantry rails, waterproofing of (Huyundai) Patrick
substructure
Building- Commercial- Office Burj Infrastructure Works Phase 3, Protective masonry works Dubai Al Futtaim Apr-07
(Emaar) Carrilion
Water- Waste water- Sewerage SDS150 Lebel Ali Sewage Self - application Jebel Ali Al Ahmadiah MWH Apr-07
Treatment Plant, (Dubai
Municipality)
Water- Marine- Sea defence Port Arabia Phase 1 - RAK, (RAK For fixing dow bars in concrete Ras Al Khamiah China Harbour Sharjah International Oct-07
Properties) Engineering Halcrow

Building- Housing- Flats Sky Court, Dubai Land 6 Construction of the foundation Dubai Chaina State Jan-08
Residential Tower, (Dubai basement Engineering
Properties) Corporation
Building- Housing- Houses Jumeirah Village Circle, (Nakheel) Self - application Dubai Al Meraikhi DEC Jan-08
General
Contracting
Building- Industrial- Power Pot Line 6 - Dubal, (Dubal) Bonding of concrete Dubai Al Futtaim Aug-08
Station Carrilion
Building- Housing- Flats J-248 - (DB-1375) Construction of Adhesive for fixing missing Al Sahel Al Ajmi Engineering Oct-18
G+2P+16+R (5No's of Towers) rebars Contracting Consultants
Commercial & Residential, (Al Company LLC
Sayyah & Sons Investment LLC)
Approvals