Pt100-Module Temp. HSCS
Pt100-Module Temp. HSCS
INTRODUCTION
The module temperature sensor is used by PV plant operators to know the temperature of
the modules installed in the array. The module temperature sensor converts this reading
into a voltage signal. This signal is sent back to the monitoring device.
As the system operator it’s important to know the systems’ performance. The module
temperature sensor will help to enhance kWh performance by ensuring reliable access to
the all-necessary data
Specifications
• Measuring Range: 0 to 100 C
• Accuracy: 0.5 C
• Sensors: Temperature: RTD Pt100Ω
• Output: 4- 20 m amp
• Supply Voltage: 12 to 24 VDC
• Housing: Poly carbonate watertight enclosure
• Protection: IP-65
• Weight: Approx. 150gms
This sensor is designed to attach directly to any solar panel. When placed on the center
back side of the panel, it accurately measures the temperature of the panel.
Prior to installation of the PV temperature sensor onto the PV panel, the installation area of
the panel back should be thoroughly cleaned. This cleaning will ensure a good bond
between sensor and panel and allow for accurate panel temperature readings.
After cleaning, peel off the protective adhesive tape on the temperature sensor and stick it
onto the back of the panel. Firmly press the sensor into place.
LOCATION RECOMENDATION
Use the following guidelines to determine the best location for mounting the module surface
temperature Sensor. Select a PV module that remains unshaded throughout the day.
MOUNTING
Observe the following requirements regarding the mounting location of the module
temperature sensor:
CALIBRATION
• If using Modbus sensor then the PV Module Temperature Sensor is factory calibrated.
• If using analog output senor then use the following info to calibrate. Output - 4 to 20 m
amp (0- 100 deg C)
If the cable length is insufficient for the installation, additional cable can be added to the existing
cable. If this is done, an accuracy derating factor must be added to the overall temperature accuracy
of this sensor.
Under no circumstances should water or cleansing agents be used on the sensing elements. It is
recommended that the accuracy of the sensor is verified every 12 months.