Exercise 3
Exercise 3
No:
Date :
PROCEDURE:
Step 1: Model Prepara5on
- Iden5fy the components of the heat dissipa5on system, including the heat sink, fan, and
other relevant objects.
- Open the Model manager window and select all blocks except the hollow block and the heat
sink object.
- Right-click the selected objects and choose "Create" -> "Assembly" to create the Heatsink-
packages-asy assembly.
- Rename the assembly as "Heatsink-packages-asy" for clarity.
- Double-click the assembly to edit it and navigate to the Meshing tab of the Assemblies panel.
Step 2: Meshing
- Toggle "Mesh separately" in the Meshing tab to create non-conformal meshed assemblies.
- Set the slack parameters for the assembly bounding box as specified in Table 4.3, ensuring
sufficient resolu5on for accurate results without excessively long run 5mes.
- Click "Update" and then "Done" to finalize the bounding box specifica5ons for the assembly.
Step 5: Parameteriza5on
- Navigate to the Solve menu and select "Define trials" to set up parametric trials for fan
loca5on op5miza5on.
- Toggle Parametric trials and specify discrete values for the fan loca5on parameter to explore
different configura5ons.
- Apply the specified values and ensure the Restart ID is blank for the 2nd trial in the Trials tab.
Step 6: Monitor Points
- Create two monitor points to track velocity in the grille and temperature in one of the solid
blocks.
- Modify the monitor points to monitor Velocity for the grille and Temperature for the block,
enabling efficient data collec5on during simula5ons.
Mesh Model:
Graphic displaying the meshed model of the system, illustra5ng the discre5za5on of the
geometry into finite elements or cells to facilitate numerical analysis, capturing temperature
gradients and airflow dynamics accurately.
Convergence Plot:
Temperature Contour:
Figure 04: Contour plot of Temperature
Contour plot represen5ng the temperature distribu5on across the computa5onal
domain, visualizing varia5ons in temperature levels within components like blocks and PCB,
aiding in iden5fying areas of heat accumula5on or cooling effec5veness.
Pressure Contour:
Contour visualiza5on displaying the spa5al distribu5on of pressure within the airflow
domain surrounding the components, offering insights into airflow behavior, pressure
differen5als, and poten5al airflow obstruc5ons or turbulence.
Velocity Contour:
Contour plot illustra5ng the velocity field within the airflow domain around the
components, depic5ng airflow magnitude and direc5on to assess cooling efficiency and heat
dissipa5on capabili5es.
RESULT:
We employed Ansys Icepak soWware to op5mize the fan loca5on in our system,
enhancing airflow and thermal management efficiency. Through me5culous simula5on and
analysis, we achieved improved cooling performance, ensuring stable opera5ng temperatures