This document is a price schedule from a bidder for an HVAC project involving fabrication of modules. It includes line items for equipment, ductwork, dampers, and other HVAC components to be supplied and installed. Quantities, unit rates, and total costs are provided. Notes indicate that quantities are based on a preliminary 30% design and will be finalized later.

Uploaded by

ajaykg
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
224 views3 pages

HVAC - CP Building

This document is a price schedule from a bidder for an HVAC project involving fabrication of modules. It includes line items for equipment, ductwork, dampers, and other HVAC components to be supplied and installed. Quantities, unit rates, and total costs are provided. Notes indicate that quantities are based on a preliminary 30% design and will be finalized later.

Uploaded by

ajaykg
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

OWNER : DuPont Company (Singapore) Pte Ltd PROJECT : SCP-2 Project BIDDER:

RFQ NO.: DPP-SI-Q-1037-C-006 WORK : Rev. : Modules Fabrication

PRICE SCHEDULES 2-8


Material Cost Item Description Qty Unit Rate Total

HVAC Work CP Buidling


Tax & Duty on Material Rate Total Fabrication Cost Rate Total Assembly Cost Total US$ Rate Total

i a

Notes The quantities provided are are based on a current design of about 30% extroplated to be what is thought would be in the final package Fabricator to insert unit rates for the work split into supply of Material / Equipment, Tax & Duty on Material / Equipment, Fabrication and final Assembly installation in the modules

ii iii A 1 2 3 4

Notes Offload, take delivery of free issue items, protect, store and then install the following in Modules Building & Process HVAC Equipment Supply Fan AHU, Cooler Classifier 3101-510-01 Control Dampers, Cooler Classifier Main Units 3101-510-03 & 04 Water Scrubber, Die Exhaust 3101-530-01 (2,380 m/h) Die Exhaust Fan 3101-530-02 (2,380 m/h) Approved vendors for all mounted fans are: FlaktWoos, Twin City, Mecomb, Mason, Supply & install of Flame proof & Spark proof Wall Mounted industrial Exhaust Fan 3100-500-01 (3600 m/h, Static pressure : 7.5 mm WC) Motor as per IEC suitable for 415V/50Hz/3Ph & Noise level shall be low. Supply & install of Flame proof & Spark proof Wall Mounted industrial Exhaust Fan 3100-500-01 (5000 m/h, Static pressure : 7.5 mm WC) Motor as per IEC suitable for 415V/50Hz/3Ph & Noise level shall be low. 1 1 1 1 No No No No -

No

No

iv

Supply and install of ducting with all acessories,flexible & fitting as per attached specification requirement. Ductwork shall be by SubCon or OWNER approved equal.

Duct work, no insulation 304 Stainless Steel ducts 40 130 m m 2 Nos 1 of 3

HVAC

#REF! #REF! 5 5.1

0.8 mm thickness 1.0 mm thickness Supply & install of S.S. 304 Canopy with capture hood velocity of 1.93 m/s (380 fpm ) for following Sizes : 1100 mm X 300 mm X 450mm (H)
75780558.xls.ms_office

OWNER : DuPont Company (Singapore) Pte Ltd PROJECT : SCP-2 Project BIDDER:

RFQ NO.: DPP-SI-Q-1037-C-006 WORK : Rev. : Modules Fabrication

PRICE SCHEDULES 2-8


Material Cost Item Description Qty Unit Rate Total

HVAC Work CP Buidling


Tax & Duty on Material Rate Total Fabrication Cost Rate Total Assembly Cost Total US$ Rate Total

C #REF! #REF!

Supply & Installation of 304 Stainless Steel Manual Volume Control dampers as per attached specification requirement. diam 500 mm diam 650 mm

1 1 No No -

D 1

Supply & installation of 304 Stainless Steel Manual Isolation dampers as per attached specification requirement. diam 200 mm

3 No -

H 1 2 3 4

Inspection hatches in ducts as per attached specification 200x300 mm 250x250 mm 300x300 mm 450x450 mm 18 No No No No

Pressure testing of ducts

Item

L 1

Process Water Pipe for Water Scrubber, Die Exhaust (with Insulation, Fittings, Supports, & Accessories) diam 25 mm

10 m -

Duct Support & Bracket

3,000

kg

Remove the following after testing, provide temporary infill and protection of system / the work for shipping. Apply protection to removed items and ship as loose items with the module. Fabricator to list items of Equipment to be removed for shipping and include allowance.

Item

vi 1 2 3

Fabricator to list additional items required for this section -

75780558.xls.ms_office

2 of 3

HVAC

OWNER : DuPont Company (Singapore) Pte Ltd PROJECT : SCP-2 Project BIDDER:

RFQ NO.: DPP-SI-Q-1037-C-006 WORK : Rev. : Modules Fabrication

PRICE SCHEDULES 2-8


Material Cost Item Description Qty Unit Rate Total

HVAC Work CP Buidling


Tax & Duty on Material Rate Total Fabrication Cost Rate Total Assembly Cost Total US$ Rate Total

vii 1

Final Handover Documentation Allow for providing Final Documentation on completion of the works 1 Item -

viii 1

Testing Allow for testing the installation prior to shipping 1 Item -

ix 1

Temporary Supports Allow for temporary supports to the works for shipping 1 Item -

x 1

Temporary Protection Allow for temporary protection of the works for shipping 1 Item -

SUB-TOTAL for Measured items to CP Building Summary Note : Type Vendor/Make Duct Ductwork subcon Damper Connols Air, Kyodo Allied, R Glazen
Wall mounted fan

Remarks

FlaktWoos, Twin City, Mecomb, Mason,

75780558.xls.ms_office

3 of 3

HVAC