10 VDR (STX-5000) StxReplayer Program Upgrade and Back
10 VDR (STX-5000) StxReplayer Program Upgrade and Back
2007. 04. 25
1. StxReplayer Program Upgrade Motive
- Normal times or minor acccident is occurred, the saved data could be Backup to
RTM PC by new added “Standard Backup” function
- Provide Integration Version for better data backup on the operating.
Ex) StxReplayer(Admin) : Administrator Version StxReplayer
StxReplayer(Only) : Provide with equipment delivery (Integration)
(General user Version)
-1-
B) Load the “Setup.Exe” file. Ex) Windows XP Professional
-2-
< Click”Next” >
-3-
< Click”Close” >
-4-
2) StxReplayer Program Delete
Way1) Delete fron the StxReplayer Program
A) Insert the delivered CD, and select the proper “StxReplayer” for the user’s O/S
Ex) WIN2K : Windows 2000 Professional
WINXP : Windows XP Professional
-5-
< Click”Finish” >
-6-
< Cilck”Close” >
C) StxReplayer Program Removing complete
Way2) After selecting “Program Add/Remove” from the controller program of RTM PC,
remove the StxReplayer program
-7-
<”StxReplayer” Program Modify/Remove screen>
-8-
3. VDR/SVDR Recording Data Backup Process
- VDR/SVDR Backup Process could be divided into Standard Backup and Incident
Backup
- Set-up as the following step before to do Backup
A) Connect the VDR/SVDR LAN Cable to the Main Cable of the RTM PC.
B) Set the Network between RTM PC and VDR/SVDR.
- Set the Network as the step of
RTM PC(Main Screen) -> My Network Configuration -> Attribution -> Local Area
Connect -> Attribution.
< Local Area Connect Attribution screen> <Internet Protocol(TCP/IP) Property screen>
=> Set the IP Address of the RTM PC which is connected to the Main Cable, and
also set Subnet Mask, Default GateWay IP as the following.
IP Address : 192. 168. 102. 89
Subnet Mask : 255. 255. 255. 0
Default GateWay IP : 192. 168. 102. 254
C) Fix the IP Address and Subnet Mask, Default GateWay IP into Default value.
-9-
1) Standard Backup
- This is used normal times or when a minor accident is occurred. It receives the Saved
Backup Data by the RTM PC with VDR Power On.
- 10 -
B) Open the RTM Window.
- Select “RTM” or click the Icon at the VdrSystem Menu
C) Select 『 Past Data 』 from the 『 Backup 』 , and set maximum download
『Storage』.(Unit: Hour, Maximum 12 Hours)
Ex) 2 hours → Backup the data(120 Folders) from maximum 2 hours before
now. In this case if VDR did not run more than 2 hours, it brings
the data of elapsed time.
D) Choose the path of RTM PC to download.
E) Press 『Start』 button.
<Process screen>
- 11 -
<Saved Data Information window after ”Past Data” completed >
- 12 -
2) Incident Backup
- This Backup is executed in case of accident or emergency. It receives the saved data
from Capsule by RTM PC with VDR Power Off.
- 13 -
B) Open the Capsule Load Window.
- Select “Load” or click Icon on the VdrSystem menu.
- 14 -
D) Set the download storage(Unit:MB) which is the 『 Read Size 』 of the 『 Etc
Config』
Ex) 10 MB → Backup the Data(4 Folders) before 4Minutes(10/2.5, 2.5M per 1Min)
from now. In this case if you set 0 at the 『Read Size』value, it brings all Data
from the Capsule.
- 15 -
F) Press『Load VDR Data』button.
- If there is no Data in the default folder, the following message doesn’t seems.
<If the Data exist in the default folder, click “Yes” to remove all files. >
<Data Backup Process Window > <Data Backup Complete Window >
G) Run the Backup Data
- Open the “RecNo.0000” from the settled path.
Ex) Settled path : “RecNo.0000” of the folder “C:₩VDR₩Capsule”
- 16 -