NATIONAL THERMAL POWER COOPERATION BADARPUR THERMAL POWER STATION NEW DELHI
Submitted by: Nikhil kainth B.tech Final year 90680573136 Electrical Engineering Duration-
CONTENT 1. INTRODUCTION TO THE COMPANY 2. OPERATION OF POWER PLANT 3. VARIOUS CYCLE AT POWER STATION 4. CONTROL & INSTRUMENTATION 5. IT DEPARTMENT 6. REFERENCE
A View Of Badarpur Thermal Power Station, New-Delhi NTPC has installed capacity of 29,394 MW. It has 15 coal based power stations (23,395 MW), 7 gasbased power stations (3,955 MW) and 4 power stations in Joint Ventures (1,794 MW). Thecompany has power generating facilities in all major regions of the country. It plans to be a 75,000MW company by 2017. Types of power station Coal Based Power Station Gas Based Power Station Joint Venture
Number 15 7 4
Total Capacity29,394 MW
NTPC has gone beyond the thermal power generation. It has diversified into hydro power, coalmining, power equipment manufacturing, oil & gas exploration, power trading & distribution. NTPC is now in the entire power value chain and is poised to become an Integrated Power Major. NTPC's share on 31 Mar 2008 in the total installed capacity of the country was 19.1% and it contributed 28.50% of the total power generation of the country during 2007-08. NTPC has set new benchmarks for the power industry both in the area of power plant construction and operations. With its experience and expertise in the power sector, NTPC is extending consultancy services to various organizations in the power business. It provides consultancy in the area of power plant constructions and power generation to companies in India and abroad. In November 2004, NTPC came out with its Initial Public Offering (IPO) consisting of 5.25% as fresh issue and 5.25% as offer for sale by Government of India. NTPC thus became a listed company with Government holding 89.5% of the equity share capital and rest held by Institutional Investors and Public. The issue was a resounding success. NTPC is among the largest five companies in India in terms of market capitalization.
VISION
Corporate vision: -A world class integrated power major, powering India's growth with increasing global presence. Mission:-Develop and provide reliable power related products and services at competitive prices, integrating multiple energy resources with innovative & Eco-friendly technologies and contribution to the society. Core Values - BCOMIT Business ethics Customer Focus Organizational & Professional Pride Mutual Respect & Trust Innovation & Speed Total Quality for Excellence
STRATEGIES
Sustainable Devolpment
STRATEGIES
Further
Technology Initiative Enchance Fuel Security
Technological Initiatives Introduction of steam generators (boilers) of the size of 800 MW. Integrated Gasification Combined Cycle (IGCC) Technology. Launch of Energy Technology Centre -A new initiative for development of technologies with focus on fundamental R&D. The company sets aside up to 0.5% of the profits for R&D. Roadmap developed for adopting Clean Development Mechanism to help get / earn Certified Emission Reduction
Corporate Social Responsibility As a responsible corporate citizen NTPC has taken up number of CSR initiatives. NTPC Foundation formed to address Social issues at national level. NTPC has framed Corporate Social Responsibility Guidelines committing up to 0.5% of net profit annually for Community Welfare Measures on perennial basis. The welfare of project affected persons and the local population around NTPC projects are taken care of through well drawn Rehabilitation and Resettlement policies. The company has also taken up distributed generation for remote rural areas.
ENVIRONMENTAL POLICY
NTPC is committed to the environment, generating power at minimal environmental cost and preserving the ecology in the vicinity of the plants. NTPC has undertaken massive a forestation in the vicinity of its plants. Plantations have increased forest area and reduced barren land. The massive a forestation by NTPC in and around its Ramagundam Power station (2600 MW) have contributed reducing the temperature in the areas by about 3c. NTPC has also taken proactive steps for ash utilization. In 1991, it set up Ash Utilization Division A Centre for Power Efficiency and Environment Protection- CENPEE" has been established in NTPC with the assistance of United States Agency for International Development- USAID. CENPEEPis efficiency oriented, eco-friendly and eco-nurturing initiative a symbol of NTPC's concern towards environmental protection and continued commitment to sustainable power development in India. As a responsible corporate citizen, NTPC is making constant efforts to improve the socioeconomic status of the people affected by its projects. Through its Rehabilitation and Resettlement programmes, the company endeavours to improve the overall socio economic status Project Affected Persons. NTPC was among the first Public Sector Enterprises to enter into a Memorandum of Understanding-MOU with the Government in 1987-88. NTPC has been placed under the 'Excellent category' (the best category) every year since the MOU system became operative.
Harmony between man and environment is the essence of healthy life and growth. Therefore, maintenance of ecological balance and a pristine environment has been of utmost importance to NTPC. It has been taking various measures discussed below for mitigation of environment pollution due to power generation.
NTPC is the second largest owner of trees in the country after the Forest Department. Environment Policy & Environment Management System
Driven by its commitment for sustainable growth of power, NTPC has evolved a well defined environment management policy and sound environment practices for minimizing environmental impact arising out of setting up of power plants and preserving the natural ecology.
Environment Management, Occupational Health and Safety Systems: NTPC has actively gone for adoption of best international practices on environment, occupational health and safety areas. The organization has pursued the Environmental Management System (EMS) ISO 14001 and the Occupational Health and Safety Assessment System OHSAS 18001 at its different establishments. As a result of pursuing these practices, all NTPC power stations have been certified for ISO 14001 & OHSAS 18001 by reputed national and international Certifying Agencies.
Pollution Control systems: While deciding the appropriate technology for its projects, NTPC integrates many environmental provisions into the plant design. In order to ensure that NTPC comply with all the stipulated environment norms, various state-of-the-art pollution control systems / devices as discussed below have been installed to control air and water pollution.
Electrostatic Precipitators: The ash left behind after combustion of coal is arrested in high efficiency Electrostatic Precipitators (ESPs) and particulate emission is controlled well within the stipulated norms. The ash collected in the ESPs is disposed to Ash Ponds in slurry form.
Flue Gas Stacks: Tall Flue Gas Stacks have been provided for wide dispersion of the gaseous emissions (SOX, NOXetc) into the atmosphere.
Low-NOX Burners: In gas based NTPC power stations, NOx emissions are controlled by provision of Low-NOx Burners(dry or wet type) and in coal fired stations, by adopting best combustion practices.
Neutralisation Pits: Neutralisation pits have been provided in the Water Treatment Plant (WTP) for pH correction of the effluents before discharge into Effluent Treatment Plant (ETP) for further treatment and use.
Coal Settling Pits / Oil Settling Pits: In these Pits, coal dust and oil are removed from the effluents emanating from the Coal Handling Plant (CHP), coal yard and Fuel Oil Handling areas before discharge into ETP.
DE & DS Systems: Dust Extraction (DE) and Dust Suppression (DS) systems have been installed in all coal fired power stations in NTPC to contain and extract the fugitive dust released in the Coal Handling Plant (CHP).
Cooling Towers: Cooling Towers have been provided for cooling the hot Condenser cooling water in closed cycle Condenser Cooling Water (CCW) Systems. This helps in reduction in thermal pollution and conservation of fresh water.
Ash Dykes & Ash Disposal systems: Ash ponds have been provided at all coal based stations except Dadri where Dry Ash Disposal System has been provided. Ash Ponds have been divided into lagoons and provided with garlanding arrangements for changeover of the ash slurry feed points for even filling of the pond and for effective settlement of the ash particles. Ash in slurry form is discharged into the lagoons where ash particles get settled from the slurry and clear effluent water is discharged from the ash pond. The discharged effluents conform to standards specified by CPCB and the same is regularly monitored. At its Dadri Power Station, NTPC has set up a unique system for dry ash collection and disposalfacility with Ash Mound formation. This has been envisaged for the first time in Asia which has resulted in progressive development of green belt besides far less requirement of land and less water requirement as compared to the wet ash disposal system.
Ash Water Recycling System: Further, in a number of NTPC stations, as a proactive measure, Ash Water Recycling System (AWRS)has been provided. In the AWRS, the effluent from ash pond is circulated back to the station for further ash sluicing to the ash pond. This helps in savings of fresh water requirements for transportation of ash from the plant. The ash water recycling system has already been installed and is in operation at Ramagundam,Simhadri, Rihand, Talcher Kaniha, Talcher Thermal, Kahalgaon, Korba and Vindhyachal. The scheme has helped stations to save huge quantity of fresh water required as make-up water for disposal of ash.
Dry Ash Extraction System (DAES): Dry ash has much higher utilization potential in ash-based products (such as bricks, aeratedautoclaved concrete blocks, concrete, Portland pozzolana cement, etc.). DAES has been installed at Unchahar, Dadri, Simhadri, Ramagundam, Singrauli, Kahalgaon, Farakka, Talcher Thermal, Korba,Vindhyachal, Talcher Kaniha and BTPS.
Liquid Waste Treatment Plants & Management System: The objective of industrial liquid effluent treatment plant (ETP) is to discharge lesser and cleaner effluent from the power plants to meet environmental regulations. After primary treatment at the source of their generation, the effluents are sent to the ETP for further treatment. The composite liquid effluent treatment plant has been designed to treat all liquid effluents which originate within the power station e.g. Water Treatment Plant (WTP), Condensate Polishing Unit (CPU) effluent,
Coal Handling Plant (CHP) effluent, floor washings, service water drains etc. The scheme involves collection of various effluents and their appropriate treatment centrally and re-circulation of the treated effluent for various plant uses. NTPC has implemented such systems in a number of its power stations such as Ramagundam,Simhadri, Kayamkulam, Singrauli, Rihand, Vindhyachal, Korba, Jhanor Gandhar, Faridabad, Farakka,Kahalgaon and Talcher Kaniha. These plants have helped to control quality and quantity of the effluents discharged from the stations.
Sewage Treatment Plants & Facilities: Sewage Treatment Plants (STPs) sewage treatment facilities have been provided at all NTPC stations to take care of Sewage Effluent from Plant and township areas. In a number of NTPC projects modern type STPs with Clarifloculators, Mechanical Agitators, sludge drying beds, Gas Collection Chambers etc have been provided to improve the effluent quality. The effluent quality is monitored regularly and treated effluent conforming to the prescribed limit is discharged from the station. At several stations, treated effluents of STPs are being used for horticulture purpose.
Environmental Institutional Set-up: Realizing the importance of protection of the environment with speedy development of the power sector, the company has constituted different groups at project, regional and Corporate Centre level to carry out specific environment related functions. The Environment Management Group, Ash Utilisation Group and Centre for Power Efficiency & Environment Protection (CENPEEP)function from the Corporate Centre and initiate measures to mitigate the impact of power project implementation on the environment and preserve ecology in the vicinity of the projects. Environment Management and Ash Utilisation Groups established at each station, look after various environmental issues of the individual station.
Environment Reviews: To maintain constant vigil on environmental compliance, Environmental Reviews are carried out atall operating stations and remedial measures have been taken wherever necessary. As a feedbackand follow-up of these Environmental Reviews, a number of retrofit and up-gradation measures have been undertaken at different stations. Such periodic Environmental Reviews and extensive monitoring of the facilities carried out at all stations have helped in compliance with the environmental norms and timely renewal of the Air and Water Consents.
Waste Management Various types of wastes such as Municipal or domestic wastes, hazardous wastes, Bio-Medical wastes get generated in power plant areas, plant hospital and the townships of projects. The wastes generated are a number of solid and hazardous wastes like used oils & waste oils, grease,
lead acid batteries, other lead bearing wastes (such as markets etc.), oil & clarifier sludge, used resin, used photo-chemicals, asbestos packing, e-waste, metal scrap, C&I wastes, electrical scrap, empty cylinders (refillable), paper, rubber products, canteen (bio-degradable) wastes, building material wastes, silica gel, glass wool, fused lamps & tubes, fire resistant fluids etc. These wastes fall either under hazardous wastes category or non-hazardous wastes category as per classification given in Government of Indias notification on Hazardous Wastes (Management and Handling)Rules 1989 (as amended on 06.01.2000 & 20.05.2003). Handling and management of these wastes in NTPC stations have been discussed below
INTRODUCTION
BADARPUR THERMAL POWER STATION was established on 1973 and it was the part of Central Government. On 01/04/1978 is was given as No Loss No Profit Plant of NTPC. Since then operating performance of NTPC has been considerably above the national average. The availability factor for coal stations has increased from 85.03 % in 1997-98 to 90.09 % in 2006-07,which compares favourably with international standards. The PLF has increased from 75.2% in1997-98 to 89.4% during the year 2006-07 which is the highest since the inception of NTPC Capacity of BADARPUR THERMAL POWER STATION Sr.no 1 2 capacity (mw) 210 95 Number 2 3 Total Capacity (MW) 420 285
BASIC PRINCIPLE
As per faradays law Whenever the amount of magnetic flux linked with a circuit changes, an EMF is produced in the circuit. Generator works on the principle of producing electricity. To change the flux in the generator turbine is moved in a great speed with steam. To produce steam, water is heated in the boilers by burning the coal. In a Badarpur Thermal PowerStation, steam is produced and used to spin a turbine that operates a generator. Water is heated,turns into steam and spins a steam turbine which drives an electrical generator. After it passes through the turbine, the steam is condensed in a condenser; this is known as a Rankine cycle. Shown here is a diagram of a conventional thermal power plant, which uses coal, oil, or natural gases fuel to boil water to produce the steam. The electricity generated at the plant is sent to consumers through high-voltage power lines. The Badarpur Thermal Power Plant has Steam Turbine-Driven Generators which has a collective capacity of 705MW. The fuel being used is Coal which is supplied from the Jharia Coal Field in Jharkhand. Water supply is given from the Agra Canal.
Electricity from Coal There are basically three main units of a thermal power plant: 1. feed water pump 2. Steam Generator or Boiler 3. Steam Turbine 4. Electric Generator (Output)
2. Cooling water pump 3. Transmission line (3-phase) 4. Unit transformer (3-phase) 5. Electric generator (3-phase) 6. Low pressure turbine 7. Condensate extraction pump 8. Condenser
9. Intermediate pressure turbine 10. Steam governor valve 11. High pressure turbine 12. DE aerator13. Feed heater 13. Coal conveyor 14. Coal hopper 15. Pulverised fuel mill 16. Boiler drum 17. Ash hopper 18. Super heater 19. Forced draught fan 20. Re heater 21. Air intake 22. Economiser 23. Air preheater 24. Precipitator 25. Induced draught fan 27. Fuel Gas Stack
1. Cooling towers
Cooling Towers are evaporative coolers used for cooling water or other working medium to near the ambivalent web-bulb air temperature. Cooling tower use evaporation of water to reject heat from processes such as cooling the circulating water used in oil refineries, Chemical plants, power plants and building cooling, for example. The tower vary in size from small roof-top units to very large hyperboloid structures that can be up to 200 meters tall and 100 meters in diameter, or rectangular structure that can be over 40 meters tall and 80 meters long. Smaller towers are normally factory built, while larger ones are constructed on site. The primary use of large , industrial cooling tower system is to remove the heat absorbed in the circulating cooling water systems used in power plants , petroleum refineries, petrochemical and chemical plants, natural gas processing plants and other industrial facilities . The absorbed heat is rejected to the atmosphere by the evaporation of some of the cooling water in mechanical forced-draft or induced draft towers or in natural draft hyperbolic shaped cooling towers as seen at most nuclear power plants.
5. Electrical generator
An Electrical generator is a device that converts kinetic energy to electrical energy, generally using electromagnetic induction. The task of converting the electrical energy into mechanical energy is Accomplished by using a motor. The source of mechanical energy may be a reciprocating or turbine steam engine, , water falling through the turbine are made in a variety of sizes ranging from small 1hp (0.75 kW) units (rare) used as mechanical drives for pumps, compressors and other shaft driven equipment, to 2,000,000 hp (1,500,000 kW) turbines used to generate electricity. There are several Classifications for modern steam turbines. Steam turbines are used in all of our major coal fired power stations to drive the generators or alternators, which produce electricity. The turbines themselves are driven by steam generated in Boilers or steam generators as they are sometimes called. Electrical power station use large steam turbines driving electric generators to produce most (about 86%) of the worlds electricity. These centralized stations are of two types: fossil fuel power plants and nuclear power plants. The turbines used for electric power generation are most often directly coupled to their-generators .As the generators must rotate at constant synchronous speeds according to the frequency of the electric power system, the most common speeds are 3000 r/min for 50 Hz systems, and 3600 r/min for 60 Hz systems. Most large nuclear sets rotate at half those speeds, and have a 4-pole generator rather than the more common 2-pole one.
its discharge is blocked); the second stage will be triggered. This stage may switch off the boiler equipment (preventing the boiler from running dry and overheating), trigger an alarm, or both.
8.Condenser
The steam coming out from the Low Pressure Turbine (a little above its boiling pump) is Brought into thermal contact with cold water (pumped in from the cooling tower) in the condenser, where it condenses rapidly back into water, creating near vacuum-like conditions inside the condenser chest.
12. Dearator
A Dearator is a device for air removal and used to remove dissolved gases (an alternate would be the use of water treatment chemicals) from boiler feed water to make it non-corrosive. A dearator typically includes a vertical domed deaeration section as the deaeration boiler feed water tank. A Steam generating boiler requires that the circulating steam, condensate, and feed water should be devoid of dissolved gases, particularly corrosive ones and dissolved or suspended solids. The gases will give rise to corrosion of the metal. The solids will deposit on the heating surfaces giving rise to localized heating and tube ruptures due to overheating. Under some conditions it may give to stress corrosion cracking. Deaerator level and pressure must be controlled by adjusting control valves- the level by regulating condensate flow and the pressure by regulating steam flow. If operated properly, most deaerator vendors will guarantee that oxygen in the deaerated water will not exceed 7 ppb by weight (0.005cm3/L)
21. Reheater
Reheater are heaters which are used to raise the temperature of air which has been fallen down due to various process.
23. Economizers
Economizer, or in the UK economizer, are mechanical devices intended to reduce energy consumption, or to perform another useful function like preheating a fluid. The term economizer issued for other purposes as well. Boiler, power plant, and heating, ventilating and air conditioning.
In boilers, economizer are heat exchange devices that heat fluids , usually water, up to but not normally beyond the boiling point of the fluid. Economizers are so named because they can make use of the enthalpy and improving the boilers efficiency. They are a device fitted to a boiler which saves energy by using the exhaust gases from the boiler to preheat the cold water used the fill it (the feed water). Modern day boilers, such as those in cold fired power stations, are still fitted with economizer which is decedents of Greens original design. In this context they are turbines before it is pumped to the boilers. A common application of economizer is steam power plants is to capture the waste hit from boiler stack gases (flue gas) and transfer thus it to the boiler feed water thus lowering the needed energy input , in turn reducing the firing rates to accomplish the rated boiler output . Economizer lower stack temperatures which may cause condensation of acidic combustion gases and serious equipment corrosion damage if care is not taken in their design and material selection.
25. Precipitator
An Electrostatic precipitator (ESP) or electrostatic air cleaner is a particulate device that removes particles from a flowing gas (such As air) using the force of an induced electrostatic charge. Electrostatic precipitators are highly efficient filtration devices, and can easily remove fine particulate matter such as dust and smoke from the air steam. ESPs continue to be excellent devices for control of many industrial particulate emissions, including Smoke from electricity-generating utilities (coal and oil fired), salt cake collection from black liquor boilers in pump mills, and catalyst collection from fluidized bed catalytic crackers from several hundred thousand ACFM in the largest coal-fired boiler application. The original parallel plate-Weighted wire design (described above) has evolved as more efficient (and robust) discharge electrode designs were developed, today focusing on rigid discharge electrodes to which many sharpened spikes are attached , maximizing corona production. Transformer rectifier systems apply voltages of 50-100 Kilovolts at relatively high current densities. Modern controls minimize sparking and prevent arcing, avoiding damage to the components. Automatic rapping systems and hopper evacuation systems remove the collected particulate matter while on line allowing ESPs to stay in operation for years at a time.
OPERATION OF BOILER
The boiler is a rectangular furnace about 50 ft (15 m) on a side and 130 ft (40 m) tall. Its walls are made of a web of high pressure steel tubes about 2.3 inches (60 mm) in diameter. Pulverized coal is air-blown into the furnace from fuel nozzles at the four corners and it rapidly burns, forming a large fireball at the centre. The thermal radiation of the fireball heats the water that circulates through the boiler tubes near the boiler perimeter. The water circulation rate in the boiler is three to four times the throughput and is typically driven by pumps. As the water in the boiler circulates it absorbs heat and changes into steam at 700 F (370 C) and 22.1 MPa. It is separated from the water inside a drum at the top of the furnace. The saturated steam is introduced into superheat pendant tubes that hang in the hottest part of the combustion gases as they exit the furnace. Here the steam is superheated to 1,000 F (540 C) to prepare it for the turbine. The steam generating boiler has to produce steam at the high purity, pressure and temperature required for the steam turbine that drives the electrical generator. The generator includes the economizer, the steam drum, the chemical dosing equipment, and the furnace with its steam generating tubes and the super heater coils. Necessary safety valves are located at suitable points to avoid excessive boiler pressure. The air and flue gas path equipment include: forced draft(FD) fan, air preheater (APH), boiler furnace, induced draft (ID) fan, fly ash collectors (electrostatic precipitator or bughouse) and the flue gas stack.
Air Path
External fans are provided to give sufficient air for combustion. The forced draft fan takes air from the atmosphere and, first warming it in the air preheated for better combustion, injects it via the air nozzles on the furnace wall. The induced draft fan assists the FD fan by drawing out combustible gases from the furnace, maintaining a slightly negative pressure in the furnace to avoid backfiring through any opening. At the furnace outlet, and before the furnace gases are handled by the ID fan, fine dust carried by the outlet gases is removed to avoid atmospheric pollution. This is an environmental limitation prescribed by law, and additionally minimizes erosion of the ID fan.
OPERATION OF TURBINE
Steam turbines are used in all of our major coal fired power stations to drive the generators or alternators, which produce electricity. The turbines themselves are driven by steam generated in Boilers' or 'Steam Generators' as they are sometimes called. Energy in the steam after it leaves the boiler is converted into rotational energy as it passes through the turbine. The turbine normally consists of several stages with each stage consisting of a stationary blade (or nozzle) and a rotating blade. Stationary blades convert the potential energy of the steam (temperature and pressure) into kinetic energy (velocity) and direct the flow onto the rotating blades. The rotating blades convert the kinetic energy into forces, caused by pressure drop, which results in the rotation of the turbine shaft. The turbine shaft is connected to a generator, which produces the electrical energy. The rotational speed is 3000 rpm for Indian System (50 Hz) systems and 3600 for American (60 Hz)systems. In a typical larger power stations, the steam turbines are split into three separate stages, the first being the High Pressure (HP), the second the Intermediate Pressure (IP) and the third the Low-pressure (LP) stage, where high, intermediate and low describe the pressure of the steam. After the steam has passed through the HP stage, it is returned to the boiler to be re-heated to its original temperature although the pressure remains greatly reduced. The reheated steam then passes through the IP stage and finally to the LP stage of the turbine. High-pressure oil is injected into the bearings to provide lubrication.
INTRODUCTION
This division basically calibrates various instruments and takes care of any faults occur in any of the auxiliaries in the plant. Instrumentation can be well defined as a technology of using instruments to measure and control the physical and chemical properties of a material.
C&I LABS
Control and Instrumentation Department has following labs: 1. Manometry Lab
2. Protection and Interlocks Lab 3. Automation Lab 4. Electronics Lab 5. Water Treatment Plant 6. Furnaces Safety Supervisory System Lab
2. Main Control Board 3. Analog & Digital Signal Control 4. Current Signal Control
This department is the brain of the plant because from the relays to transmitters followed by theelectronic computation chipsets and recorders and lastly the controlling circuitry, all fall under this.
MANOMETER
Its a tube which is bent, in U shape. It is filled with a liquid. This device corresponds to a difference in pressure across the two limbs.
Protection and Interlock System1. HIGH TENSION CONTROL CIRCUIT for high tension system the control system are excited by separate D.C supply. For starting the circuit conditions should be in series with the starting coil of the equipment to energize it. Because if even a single condition is not true then system will not start.
2.LOW TENSION CONTROL CIRCUIT For low tension system the control circuits are directly excited from the 0.415 KV A.C supply. The same circuit achieves both excitation and tripping. Hence the tripping coil is provided for emergency tripping if the interconnection fails.
3.AUTOMATION LAB
This lab deals in automating the existing equipment and feeding routes. Earlier, the old technology dealt with only (DAS) Data Acquisition System and came to be known as primary systems. The modern technology or the secondary systems are coupled with (MIS) Management Information System. But this lab universally applies the pressure measuring instruments as the controlling force. However, the relays are also provided but they are used only for protection and interlocks.
4.PYROMETRY LAB
LIQUID IN GLASS THERMOMETER Mercury in the glass thermometer boils at 340 C which limits the range of temperature that can be measured. It is L shaped thermometer which is designed to reach all inaccessible places. 1. ULTRA VIOLET CENSORThis device is used in furnace and it measures the intensity of ultra violet rays there and according to the wave generated which directly indicates the temperature in the furnace. 2, THERMOCOUPLES This device is based on SEEBACK and PELTIER effect. It comprises of two junctions at different temperature. Then the emf is induced in the circuit due to the flow of electrons. This is an important part in the plant. 3. RTD (RESISTANCE TEMPERATURE DETECTOR) It performs the function of thermocouple basically but the difference is of a resistance. In this due to the change in the resistance the temperature difference is measured. In this lab, also the measuring devices can be calibrated in the oil bath or just boiling water (for low range devices) and in small furnace (for high range devices).
each of the feeder-mills. The furnace has six feeder mills each separated by warm air pipes fed from forced draft fans. In first stage indirect firing is employed that is feeder mills are not fed directly from coal but are fed from three feeders but are fed from pulverized coalbunkers. The furnace can operate on the minimum feed from three feeders but under no circumstances should anyone be left out under operation, to prevent creation of pressure different within the furnace, which threatens to blast it.
6.ELECTRONICS LAB
This lab undertakes the calibration and testing of various cards. It houses various types of analytical instruments like oscilloscopes, integrated circuits, cards auto analyzers etc.Various processes undertaken in this lab are: 1. Transmitter converts mV to mA. 2. Auto analyzer purifies the sample before it is sent to electrodes. It extracts the magnetic portion.
ANNUNCIATIN CARDS
They are used to keep any parameter like temperature etc. within limits. It gets a signal if parameter goes beyond limit. It has a switching transistor connected to relay that helps in alerting the UCB.
2. Machines So the Parameters to be monitored are: 1. Speed 2. Temperature 3. Current 4. Voltage 5. Pressure
6. Eccentricity 7. Flow of Gases 8. Vacuum Pressure 9. Valves 10. Level 11. Vibration
PRESSURE MONITORING
Pressure can be monitored by three types of basic mechanisms 1. Switches 2. Gauges 3. Transmitter type For gauges we use Bourdon tubes. The Bourdon Tube is a non-liquid pressure measurement device. It is widely used in applications where inexpensive static pressure measurements are needed. A typical Bourdon tube contains a curved tube that is open to external pressure input on one end and is coupled mechanically to an indicating needle on the other end, as shown schematically below.
Typical Bourdon Tube Pressure Gauge
For Switches pressure switches are used and they can be used for digital means of monitoring as switch being ON is referred as high and being OFF is as low. All the monitored data is converted to either Current or Voltage parameter. The Plant standard for current and voltage are as under Voltage: 0 10 Volts range Current: 4- 20 milli-Amperes
We use 4mA as the lower value so as to check for disturbances and wire breaks. Accuracy of such systems is very high. ACCURACY : 0.1 % Programmable Logic Circuits (PLCs) are used in the process as they are the heart of Instrumentation.
TEMPERATURE MONITORING
We can use Thermocouples or RTDs for temperature monitoring. Normally RTDs are used for low temperatures. Thermocouple selection depends upon two factors: 1. Temperature Range
2. Accuracy Required Normally used Thermocouple is K Type Thermocouple: In this we use Chromel (Nickel-Chromium Alloy) / Alumel (Nickel-Aluminium Alloy) as two metals. This is the most commonly used general purpose thermocouple. It is inexpensive and, owing to its popularity, available in a wide variety of probes. They are available in the 200C to +1200C range. Sensitivity is approximately 41 V/C. RTDs are also used but not in protection systems due to vibrational errors. We pass a constant current through the RTD. So that if R changes then the Voltage also changes. RTDs used in Industries are Pt100and Pt1000 Pt100 : 0C 100 ( 1 = 2.5 0C ) Pt1000 : 0C -1000 Pt1000 is used for higher accuracy. The gauges used for Temperature measurements are mercury filled Temperature gauges. For Analog medium thermocouples are used and for Digital medium Switches are used which are basically mercury switches.
FLOW MEASUREMENT
Flow measurement does not signify much and is measured just for metering purposes and for monitoring the processes
ROTAMETERS:
A Rotameter is a device that measures the flow rate of liquid or gas in a closed tube. It is occasionally misspelled as 'Rotometer'. It belongs to a class of meters called variable area meters, which measure flow rate by allowing the cross sectional area the fluid travels through to vary, causing some measurable effect. A rotameter consists of a tapered tube, typically made of glass, with a float inside that is pushed up by flow and pulled down by gravity. At a higher flow rate more area (between the float and the tube) is needed to accommodate the flow, so the float rises. Floats are made in many different shapes, with spheres and spherical ellipses being the most common. The float is shaped so that it rotates axially as the fluid passes. This allows you to tell if the float is stuck since it will only rotate if it is not. For Digital measurements Flap system is used. For Analog measurements we can use the following methods : 1. Flow meters 2. Venturimeters / Orifice meters 3. Turbines 4. Mass flow meters( oil level ) 5. Ultrasonic Flow meters 6. Magnetic Flow meter( water level ) Selection of flow meter depends upon the purpose, accuracy and liquid to be measured so different types of meters used.
TURBINE TYPE:
They are simplest of all. They work on the principle that on each rotation of the turbine a pulse is generated and that pulse is counted to get the flow rate.
VENTURIMETERS :
Referring to the diagram, using Bernoulli's equation in the special case of incompressible fluids (such as the approximation of a water jet), the theoretical pressure drop at the Constriction would be given by(/2)(v22- v12). And we know that rate of flow is given by: Flow = k (D.P) Where DP is Differential Pressure or the Pressure Drop.
CONTROL VALVES
A valve is a device that regulates the flow of substances (either gases, fluidized solids, slurries, or liquids) by opening, closing, or partially obstructing various passageways. Valves are technically pipe fittings, but usually are discussed separately. Valves are used in a variety of applications including industrial, military, commercial, residential, transportation. Plumbing valves are the most obvious in everyday life, but many more are used. Some valves are driven by pressure only, they are mainly used for safety purposes in steam engines and domestic heating or cooking appliances. Others are used in a controlled way, like in Otto cycle engines driven by a camshaft, where they play a major role in engine cycle control. Many valves are controlled manually with a handle attached to the valve stem. If the handle is turned a quarter of a full turn (90) between operating positions, the valve is called a quarterturn valve. Butterfly valves, ball valves, and plug valves are often quarter-turn valves. Valves can also be controlled by devices called actuators attached to the stem. They can be electromechanical actuators such as an electric motor or solenoid, pneumatic actuatorswhich are controlled by air pressure, or hydraulic actuators which are controlled by the pressure of a liquid such as oil or water. So there are basically three types of valves that are used in power industries besides the handle valves. They are : PNEUMATIC VALVES -They are air or gas controlled which is compressed to turn or move them HYDRAULIC VALVES- They utilize oil in place of Air as oil has better compression
IGNITER SYSTEM
Igniter system is an automatic system, it takes the charge from 110kv and this spark is brought in front of the oil guns, which spray aerated HSD on the coal for coal combustion. There is a 5 minute delay cycle before igniting, this is to evacuate or burn the HSD. This method is known as PURGING.
PRESSURE SWITCH
Pressure switches are the devices that make or break a circuit. When pressure is applied, the switch under the switch gets pressed which is attached to a relay that makes or break the circuit. Time delay can also be included in sensing the pressure with the help of pressure valves. Examples of pressure valves: 1. Manual valves (tap) 2. Motorized valves (actuator) works on motor action 3. Pneumatic valve (actuator) _ works due to pressure of compressed air 4. Hydraulic valve