0104 103AirHawkAdv4000

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

AirHawk® SCBA

Now available with MSA’s Advantage® 4000 Facepiece


5 Lightweight, durable, and economical SCBA
for industrial applications.

The AirHawk SCBA provides respiratory MSA’s Push-To-Connect (P-T-C) Adapter


protection solutions for many varied is approved with the AirHawk SCBA
industrial and environmentally hazardous and installs easily without special tools.
applications. Now offered with MSA’s new This adapter provides both inhalation
Advantage 4000 Facepiece, combining new check valve and exhalation valves,
features and benefits not offered preventing exhaled air from entering
previously within a single respirator and contaminating the mask-mounted
facepiece platform. The AirHawk SCBA regulator.
comprises five major components: the
facepiece, regulator, cylinder, carrier and Ultra Elite® Facepiece offers choice of
harness assembly and an End-of-Service- three sizes, nosecups in two sizes, and
Time-Indicator (EOSTI). either SoftFeel Rubber or silicone
facepiece material. Other features include
The Advantage 4000 Facepiece designed inhalation check valve, molded
for the AirHawk SCBA is NIOSH-approved, polycarbonate lens, mechanical speaking
versatile, comfortable, and affordable, diaphragm, adjustable rubber straps, and
adapting to many respiratory applications. optional hairnet-style head harness.
Simply choose the adapter and
components that best fit your needs and
easily lock them into place. The Advantage
4000 Facepiece is also available in three

sizes, has nosecup standard, and is offered


in either SoftFeel® Rubber or silicone
material. Choose rubber or net-style head
harness. Its many benefits include more
simplified fit tests, cost-savings, and
reduced inventory.

MSAnet.com|1.800.MSA.2222
The AirHawk First-Stage Regulator, part of a two-stage Applications
regulator system, reduces the cylinder pressure to slightly
above atmospheric pressure. The Firehawk™ Push-to-Connect • Wastewater
MMR (mask mounted regulator), further adjusts the air flow to • HazMat
meet users’ respiratory requirements. Through engineering
advancements, MSA has kept both regulators simple for durability, • HVAC
reliability, ease of maintenance, and safety. • Construction
• Utility
Carrier and Harness Assembly evenly distributes the SCBA’s
weight over hips for comfort and stability. Composite thermoset • Chemical
plastic backplate is reinforced with glass fibers and features spine • Nuclear
strain components. Shoulder straps with easy-release friction
buckles and a center-pull waist belt system are also design • Oil and gas
elements. • Paper and pulp
Air Cylinders are offered with both low and high pressure options:
three low-pressure (2216 psig), 30-minute-rated cylinders: carbon-
wrapped, fiberglass hoop-wound, or all-aluminum. High-pressure AirHawk SCBA accessories
(4500 psig) carbon-wrapped cylinders are available in 30-, 45-, or
60-minute durations. • Spectacle kits
• Cover lens
End-of-Service-Time-Indicator (EOSTI) incorporates a non-
aspirating whistle mounted on the SCBA gauge-line and signals • Confidence Plus Germicidal Cleaner
users that their cylinder air supply has been reduced to 20 to 25 • Wall storage cases
percent of its rated air supply.
• Welders’ adapter
Options • Electronic welding lens
• Shoulder pads, lumbar pad, and chest strap
• Carrier harness of either Nylon or high-strength Kevlar material
• Low-and high-pressure versions
• Integrated PASS (Personal Alert Safety System) device
• Airline attachment for independent air source connection from
up to 300 feet
• Rubber or hairnet style head harness
Advantae 4000 Spectacle Kit Welders’ Adapter & Accessories Storage Cabinets
For use by workers who must wear For eye Two-unit and single-unit wall mounting case.
corrective lenses, the spectacle kit can protection in Chemical resistant ABS plastic case resists
be easily inserted into an Ultra Elite or welding weathering, moisture, and corrosion to ensure
Advantage 4000 Facepiece applications SCBA stays in ready-to-use condition.
where
respiratory Part No. Description
protection is
10053102 Double case for SCBA’s supplied
required, a
with LP30, HP45, HP60, and
welders’
low-profile cylinders
adapter can
be easily installed over an Ultra Elite or 10053103 Double case for SCBA’s supplied
Advantage 4000 Facepiece lens. with HP30 cylinders only
10052744 Single case for SCBA’s supplied
Part No. Description with LP30, HP45, HP60, and
806432 Welders’ Adapter, Ultra Elite low-profile cylinders
Facepiece 10052745 Single case for SCBA’s supplied
10065326 Welders’ Adapter, with H30 cylinders only
Part No. Description Single-Port Advantage 4000
804638 Ultra Elite Spectacle Kit Facepiece
(side wire support) 486328 Welders’ Hood, Kevlar
493581 Ultra Elite Spectacle Kit 10068601 Auto-Change Electronic Welding
(center support) Lens
10029298 Advantage 4000 Spectacle Kit
MSA Confidence Plus® Germicidal Cleaner
Lens Covers Mix with warm water for a germicidal
Lens covers, cleaner that is effective
available in clear against various micro-
and smoke-tinited, organisms including
provide a immunodeficiency virus Type
convenient way to 1 (HIV-1) (associated with
add a layer of AIDS). EPA approved for use
protection against on safety equipment.
scratches.

Part No. Description


10009971 Confidence Plus
Germicidal Cleaner
Part No. Description
491500 Ultra Elite clear cover lens
(25 per pack)
805456 Ultra Elite smoke-tinted cover
lens (25 per pack)
10031542 Advantage 4000 clear
cover lens (25/pkg)
10031543 Advantage 4000 smoke
cover lens (25/pkg)

MSAnet.com|1.800.MSA.2222
Optional Carbon Cylinder

Optional Shoulder Pads

Air Frame Carrier

Nylon or Kevlar Harness

Optional Chest Strap


EOSTI

Easy-to-release
Friction Buckle

Optional Lumbar Pad

Optional Air Line Attachment

FireHawk MMR Regulator

Center Pull Waist Belt

Advantage 4000 Facepiece


Ordering information
SCBA Harness Facepiece Cylinder Case Part Number
Ultra Elite, medium, Hycar,
AirHawk (2216) Nylon with chest strap Aluminum (30 minutes) Hard Case 10043201
rubber head harness
Ultra Elite, medium, Hycar,
AirHawk (2216) Nylon with chest strap Aluminum (30 minutes) No Case 10043202
rubber head harness
Ultra Elite, medium, Hycar, L-30 Stealth Carbon
AirHawk (2216) Nylon with chest strap Hard Case 10043204
rubber head harness Cylinder (30 minutes)
Ultra Elite, medium, Hycar, L-30 Stealth Carbon
AirHawk (2216) Nylon with chest strap No Case 10043203
rubber head harness Cylinder (30 minutes)

The Assemble-To-Order System allows MSA to offer many choices; users can choose from an extensive line of cylinder options,
harness and carrier assemblies. There are hundreds of possible combinations, and MSA continues to develop even more options
to allow workers to select just the right air mask for the job. Listed below are part numbers for the four most popular AirHawk
SCBA assemblies. You can also use MSA’s A-T-O System to customize your AirHawk SCBA to best fit your needs.

MMR
Carrier/ Pad Air-Line Head
SCBA Type Cylinder Regulator Facepiece Nosecup PASS Case
Harness Options Option Harness
Type

AL AirHawk A Nylon 0 None 0 None G Firehawk 0 None A None 0 None 0 None 0 Gauge 0 None
MMR without 1 Shoulder 1 3AL PTC with 1 Snap-Tite B Ultra Elite, 1 Medium 1 Rubber 3 Whistle with 1 Hard
(2216 chest Pad Aluminum Swivel & Aluminum Hycar, Small ICM Tx with Case
psig) strap Solid 2 Large 2 Net
2 Lumbar 2 Hoop- 2 Hansen C Ultra Elite, sensor 2 Soft
B Nylon Cover
Pad Wound SST Hycar, Medium 5 Whistle with Case
with ICM Tx
chest 3 Shoulder 3 30' Stealth 3 Hansen D Ultra Elite,
strap Pad & Brass Hycar, Large
Lumbar 4 Foster E Ultra Elite,
C Kevlar Pad
without Steel Silicone, Small
chest 4 Swiveling 5 Snap-Tite F Ultra Elite,
strap Lumbar Locking Silicone, Medium
Pad Aluminum
D Kevlar G Ultra Elite,
with 5 Swiveling 6 Foster SST Silicone, Large
chest Lumbar
strap Pad & H Advantage 4000,
Shoulder Hycar, Small
Pad J Advantage 4000,
Hycar, Medium
K Advantage 4000,
AH AirHawk 0 None Hycar, Large
MMR 30' Stealth L Advantage 4000,
1
(4500 Silicone, Small
psig) 2 45' Stealth
Low Profile M Advantage 4000,
60' Stealth Silicone, Medium
3
N Advantage 4000,
Silicone, Large

Note: This matrix must only be used for ordering


complete Air Mask assemblies. An Air Mask
type must be specified. This matrix cannot be
B
used for ordering individual components (i.e.
facepieces, cylinders, etc.) Please order Part Number
components separately using their standard
MSA part number. NIOSH Approved, Non-NFPA Compliant

Note: This Bulletin contains only a general description of the Corporate Headquarters MSA Mexico
products shown. While uses and performance capabilities P.O. Box 426, Pittsburgh, PA 15230 USA Phone (52) 55 2122 5770
are described, under no circumstances shall the products be Phone 412-967-3000 Fax (52) 55 5359 4330
used by untrained or unqualified individuals and not until the www.MSAnet.com MSA International
product instructions including any warnings or cautions U.S. Customer Service Center Phone 412-967-3354
provided have been thoroughly read and Phone 1-800-MSA-2222 FAX 412-967-3451
understood. Only they contain the complete Fax 1-800-967-0398
and detailed information concerning proper
MSA Canada
use and care of these products.
Phone 1-800-672-2222
Fax 1-800-967-0398
ID 0104-103-MC / June 2008
© MSA 2008 Printed in U.S.A.

You might also like