EN Chapter VEGASON

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Level l Ultrasonic

Ultrasonic level measurement


In non-contact ultrasonic level measurement, the sensor emits ultrasonic
pulses in the direction of the medium, which then reflects them back.

The elapsed time from emission to reception of the signals is proportional


to the level in the tank. Ultrasonic sensors are ideal for simple standard
applications, both for liquids and bulk solids.

The advantages

 Non-contact level measurement for a wide range of media


 Suitable for bulk solids and liquids
 Adjustment without medium or filling

24
PRO PRO

VEGASON 61 VEGASON 62

Application Liquids and bulk solids in small vessels Liquids and bulk solids in small vessels

Measuring range Liquids: 0.25 … 5 m Liquids: 0.4 … 8 m


Bulk solids: 0.25 … 2 m Bulk solids: 0.4 … 3.5 m

Transducer of PVDF of PVDF

Process fitting Thread G1½, 1½ NPT Thread G2, 2 NPT

Process temperature -40 … +80 °C -40 … +80 °C

Process pressure -0.2 … +2 bar -0.2 … +2 bar


(-20 … +200 kPa) (-20 … +200 kPa)

Accuracy ±10 mm ±10 mm

Signal output 4 … 20 mA/HART, Profibus PA, 4 … 20 mA/HART, Profibus PA,


Foundation Fieldbus Foundation Fieldbus

Display/adjustment PLICSCOM, PACTware/DTM, PLICSCOM, PACTware/DTM,


VEGADIS 81, VEGADIS 82 VEGADIS 81, VEGADIS 82

Approvals ATEX, UKEX, IECEx, FM, CSA, EAC (GOST), ATEX, UKEX, IECEx, FM, CSA, EAC (GOST),
UKR Sepro, Ship, SIL2 UKR Sepro, Ship, SIL2

Benefit
 Maintenance-free operation through non-contact measuring method

25