12 Volt Battery SL12200 LITHUIM BATTERY

Specification

Nominal Voltage 12.8V


Nominal Capacity 200
00Ah
Minimum Capacity 98Ah
Energy 2560Wh
Electrical Cycle Life >2000 cycles @0.2C 100%DOD
Characteristics Months Self Discharge <3%
Efficiency of Charge 100% @0.2C
Efficiency of Discharge 96~99% @0.2C
BMS Functions Over charge, over discharge, over current, short circuit
and temperature protection
Charge Voltage 14.6±0.2V
Charge Mode 0.2C to 14.6V, then 14.6V,charge current to 0.02C
Standard (CC/CV)
Charge Max. Charge Current 50A
Charge Cut-off Voltage 14.6V±0.2V
Max. Discharge 100A
Standard Current
Discharge Discharge Cut-off 10V±0.5V
Voltage
Charge Temperature 0 ℃ to 55 ℃ (32F to 131F) @60±25% Relative Humidity
Discharge Temperature -20 ℃ to 60 ℃ (-4F to 140F) @60±25% Relative Humidity
Environmental
Storage Temperature -20 ℃ to 45 ℃ (-4F to 113F) @60±25% Relative Humidity
IP Class IP65
Case Plastic
Mechanical Approx. Dimensions L522*W240*H220
2 mm
Approx. Weight ±21.32KG

LITHIUM BATTERY
Page 1 of 2
12 Volt Battery SL12200 LITHIUM BATTERY

Product performance test

NO. Items Test condition and method Criterion

After standard charging, store at 20 ± 5 ℃ for The discharge Capacity: should


Self-Discharge
not less than 85% of Initial
1 30 days, and then use 0.2C current discharge
Performance Capacity
to 10.0V discharge cut-off voltage

Battery charged at 1.0C current with a voltage


Over Charge Test No explosion,No fire
limit of 12.8V.charging is continued for 3 hours.
2

Battery discharged continuously at the constant


3 Over Charge Test current of 0.5C to 12.8V,then discharge the No explosion,No fire
battery with a current of 0.2C to 10V

Let the battery subjected simple harmonic motion


with an amplitude of 0.8mm (1.6mm) total
maximum excursion].The frequency is to be
Vibration test varied at the rate of 1 hertz per minute No explosion,No fire
4 between10 and 55hertz, The battery is to be
tested for 30min in each mutually perpendicular
directions.

Fully charge,Short circuit by connecting the


External
positive and negative terminals with a circuit load
Short-Circuiting having a maximum resistance load of 100m Ω , No explosion,No fire
5
Test until its temperature has fallen by10℃ from the
peak point ,the testis over .

Humidity A charged battery is placed in a box for 48 hours


6 where the temperature is 40℃±2℃ and the No explosion,No fire
and heat test relative humidity is 90%~95%

After the battery is fully charged, place the


battery on a flat surface, place a steel rod with a
7 Impact test diameter of 10mm in the center of the battery, No explosion,No fire
and drop a 5kg weight onto the battery from a
height of 50mm.