Mit220 en
Mit220 en
Mit220 en
MIT200 SERIES
Analogue and digital insulation & continuity tester
MIT200 Series
Digital/Analogue Insulation and Continuity testers
• Insulation testing to 1000Mohms
• Digital/Analogue display
• CATIII 600V
• Conforms to EN61557-1
MIT220
MIT230
Safety
Every Megger instrument is designed with
safety as its primary objective. All instruments
meet or exceed the requirements of safety Insulation testing
directive IEC 61010. 250V Y Y
Default fault meter
A built-in voltmeter automatically switches in 500V Y Y
when the instrument is connected to a circuit 1000V Y
with an AC or DC voltage greater than 25V.
1000Mohms range Y Y
Test inhibit
Circuits in excess of 25V will generate a Auto-ranging Y Y
voltage warning. Circuits over 50V will inhibit Auto discharge Y Y
testing on both continuity and insulation test
ranges, protecting the operator and the Test Inhibit Y Y
instrument from injury or damage. Live circuit voltage display Y Y
600V CATIII Continuity testing
The MIT200 series has been designed for use
on applications up to 600V CATIII. Continuity@ >200mA Y Y
All instruments are fully compliant with the Continuity to 0.01 Ohms Y Y
safety requirements of IEC61010 and meet all
Test Lead Null (9.99Ohms) Y Y
requirements of EN61557 for insulation and
continuity testing. Automatic continuity test Y Y
Continuity buzzer with 5ohm
Applications threshold Y Y
The MIT200 series will find applications in
electrical contracting, both on domestic and Default volts warning Y Y
industrial systems, as well as site General
maintenance and service departments.
Digital display + arc Y Y
The MIT200 series of insulation and continuity Battery condition Y Y
testers are ideal for testing transformers, Auto power down Y Y
motors, generators,
switchgear, panel building, domestic Tough carry case Y Y
appliances, power tools etc., as well as fixed Test leads Y Y
electrical wiring systems. CATIII 600V Y Y
Their small size and light weight make them
ideal for those engineers that need to carry Environmental
them for extended periods. Operation temperature -10C to +55C
All instruments meet the Storage temperature) -20 C to + 65 C
requirements of most International Standards
IP rating IP40 IP40
including VDE0413 Part 1 and BS7671 (the
16th Edition of the IEE Wiring Regulations). Included accessories
Standard test leads with prods
and clips Y Y
Certificate of test Y Y
Printed user guide
Warranty 3 3
MIT200 SERIES
Analogue and digital insulation & continuity tester
Power supply
Continuity ranges Battery 6 x 1,5 V cells IEC LR6 type(AA alkaline).
Measuring Range: 0,01Ω - 100,0 Ω Rechargeable NiCd or NiMH cells may be
(0 -50 Ω on analogue used.
scale) Battery condition is constantly shown on the display as a
Open Circuit Voltage: 5V±1V four-section bar-graph.
Short Circuit Current: 205 mA, ± 5 mA @
(0-10ohms)
>20mA @10 - 100ohms
Accuracy (at 20° C) Battery Life
MIT200,210,220,230 ±0,01Ω to 9,99Ω ±3% 3500 consecutive tests (5 seconds per test) on any test
±2 digits using 2Ah batteries.
10,0Ω to 99,9Ω ±5% Weight
±2 digits All units 530gms ±5%
Dimensions
Zero Offset Adjust: All units 195 x 98 x 40mm
MIT200,210,220,230 0 to 9,99Ω E.m.c
In accordance with IEC61326 including amendment No.1
Continuity Buzzer
MIT200,210,220,230 Operates at <5 Ω.
MIT200 SERIES
Analogue and digital insulation & continuity tester
ORDERING INFORMATION
Item (Qty) Order Code
250V/500V Insulation & Continuity tester MIT220-EN
250V/500V/1000V Insulation & continuity tester MIT230-EN
Included accessories
Lead set with prods and clips
Carry case
Calibration certificate
User guide
Optional accessories
Fused test lead set 6220-789
INFORMATIO
MIT220-EN