The document provides fault codes for the RB211-535E4 engine electronic control equipment, bleed valve control unit, and turbine protection unit. It lists specific fault codes and their corresponding systems and issues.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
232 views2 pages
EEC Fault Codes
The document provides fault codes for the RB211-535E4 engine electronic control equipment, bleed valve control unit, and turbine protection unit. It lists specific fault codes and their corresponding systems and issues.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2
“For Reference Only”
RB211-535E4 - EEC Fault Codes
Code System Input
02 Ground Test Switch “ON” with Engine Running
1A Short Duration Intermittent N1 Fault 14 N1 Major signal Fault or Circuit Fault 21 EGT Signal Major Open Circuit Fault 24 EGT Signal Rate or Range Fault 2A Short Duration Intermittent EGT Fault Due to Rate or Range 2B Short Duration Intermittent EGT Fault Due to Open Circuit 31 FFG Torque Motor Coil 1 or 2 Open Circuit 34 LVDT Range Fault 35 LVDT / Torque Motor Fault Detected During Power Up 39 Fail Fix Solenoid Fault 40 EPR and P1 Signal Failure 43 EPR or P1 Signal Failure 44 EPR and/or P1 Signal Rate or Range Fault 47 P1 from EPR Transmitter, Failed Cross Check with P1 from L & R ADC’s 4A Short Duration Intermittent EPR and P1 Fault 54 TLA Transducer Output Incorrect 5A Short Duration Intermittent TLA Output Fault 60 Left ADC Signal Lost (All Parameters) 61 Left ADC Signal Fault (One or More Parameters) 64 Left ADC Range Fault (One or More Parameters) 66 Left ADC Altitude Fault 67 P1 From Left ADC Has Failed Cross Check 68 T1 From Left ADC Has Failed Cross Check 70 Right ADC Signal Lost (All Parameters) 71 Right ADC Signal Fault (One or More Parameters) 74 Right ADC Range Fault (One or More Parameters) 76 Right ADC Altitude Fault 77 P1 From Right ADC Has Failed Cross Check 78 T1 From Right ADC Has Failed Cross Check 94 T2 Range Error 96 T1E Has Failed Cross Check With T1 From L and R ADC’s D6 Altitude From L & R ADC’s Differ By More than 252 Feet D7 P1 Cross Check Error – Between L and R ADC’s D8 P1 Cross Check Error – Between L and R ADC’s B3 FFG Not Following EEC Instructions (May be EEC or FFG Fault) B* Any other B Code, Replace EEC “For Reference Only”
RB211-535E4 - BVCU & TPU Fault Codes
BVCU LEVEL SYSTEM INPUT
01 M ALTITUDE SWITCH FAULT
02 M N2 NO. 1 SPEED PROBE FAULT 03 M N2 NO. 2 SPEED PROBE FAULT 04 M PLA TRANSDUCER SIGNAL FAILED 05 M T2 THERMOCOUPLE SIGNAL FAULT 06 M DGCU “A” FAULT (UPPER) 07 M DGCU “B” FAULT (LOWER) 10 M HP3 SOLENOID (LOWER) COIL “A” OR “B” FAULT 11 M HP3 SOLENOID (UPPER) COIL “A” OR “B” FAULT 12 M IP6 SOLENOID (RIGHT) COIL “A” OR “B” FAULT 13 M IP6 SOLENOID (RIGHT) COIL “A” OR “B” FAULT 16 M PLA TRANSDUCER INCORRECTLY SET 18 M HP2 SOLENOID COIL “A” FAULT 19 M HP2 SOLENOID COIL “A” FAULT 91 M DDU CHANNEL 1 FAULT. CHANNEL INOPERATIVE 92 M DDU CHANNEL 2 FAULT. CHANNEL INOPERATIVE BB M BVCU INTERNAL FAULT
TPU LEVEL M = MAINTENANCE Level Messages
10 M P4 TRANSDUCER OR PROCESS FAULT
20 M DGCU A OR B, OR GROUND TEST SWITCH FAULT 30 M TFU SOLENOID OR WIRING FAULT 40 M SURGE DETECTED OR P4 TRANSDUCER FAULT 50 M INTERNAL UNIT FAULT – ASSOCIATED WITH IGNITION 60 M PLA TRANSDUCER OR WIRING FAULT 90 M EICAS MAINTENANCE LINE FAULT, GROUNDED BY BVCU OR SYSTEM DEPOWERED (DUE TO BVCU CODES BEING PRESENT) B* M INTERNAL TPU FAULT