The document provides instructions for using a digital component ESR meter multi-function tester. It describes the tester's functions such as powering on/off and starting tests, using different test sockets, supporting capacitor discharge, and accessing additional functions through a selection menu.

Uploaded by

parminder singh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views4 pages

Esr02 Pro

The document provides instructions for using a digital component ESR meter multi-function tester. It describes the tester's functions such as powering on/off and starting tests, using different test sockets, supporting capacitor discharge, and accessing additional functions through a selection menu.

Uploaded by

parminder singh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Digital Component ESR Meter Multi-function Tester

Model: ESR02 pro


User Manual

Product Details:
Function Testing:
Usage Instructions:
a. Power ON: Press “POWER/TEST” button before using.
b. Test: Press “POWER/TEST” button to start a test. Regardless of the pin sequence, this meter will
recognize the pin’s function and layout on the screen.
c. Power OFF: Automatically power down if no button operation in 20 seconds.
d. Test Socket: With 3 test sockets, SMD socket, Plug-in devices socket and Probe socket. The port 1,
2, 3 of each socket are the same, they are connected internal.
e. SMD Device Test: Test via SMD socket or probe. While using SMD socket, put some pressure on
device for better connection.

f. Electrolytic Capacitor Discharge Support max 2000uF/50V capacitor discharge with the internal
1K/1W resistor, and discharge of 2 seconds at least.
Use external discharger while the capacity is higher.
Discharge is standalone function, no need to power on or press button.
g. Selection Menu: A long button press (>0.5s) will enter the selection menu for additional functions.
Short button press to switch different functions and long button press (>0.5s) to enter Submenu.
 Switch off: Long button press to power Off immediately.
 Transistor: exit Selection Menu, return to transistor test.
 Frequency: reserved.
 f-Generator: with the button press can select different frequencies output from T2 (Test Port
2), and T1, T3 will be the reference ground. Frequencies selectable from 1 Hz to 2 MHz, amplitude
is 5V.
 10-bit PWM: Generates a 7.8KHz frequency with selectable pulse width at the pin T2. With a
short button press (<0.5s) the pulse width is increased by 1%, with a longer button press (>0.5s,
<1.3s) the pulse width is increased by 10%.
 C+EST@TP1:3: It’s a stand-alone capacity measurement with ESR measurement at the test pins
T1 and T3.
 Rotary Encoder: Reserved.
 Self-test: Full self-test with calibration.
 Contrast: Contrast value for a graphic display, selectable from 33to 55.
Note: In selection mode, the Tester will auto power off after 8 minutes without any button press.
Attention:
 Always be sure to discharge capacitors before connection them to the tester.
 Power down the equipment if test components mounted in a circuit.
 If using DC supply, please choose DC 9V-12V adapter (including 9V and 12V).
 When the battery power is under 6V, please replace a new one.

Calibration:
 Short T1, T2, T3 to one, then press button.
 When LCD shows “Selftest mode.. ?”, press button within 2 seconds to enter calibration mode,
otherwise will come into transistor test mode.
 Tester automatic calibration until LCD shows “isolate Probes!”, then separate T1, T2 and T3.
 Wait a few seconds until LCD shows “Test End”.