0% found this document useful (0 votes)
341 views39 pages

10 Aaa21290r

This document provides replacement part information for controllers used in elevator systems. It includes a table of contents listing the main components covered, drawings of relevant assemblies, and part numbers. Safety certification information and the responsible subject matter expert are also included.

Uploaded by

kędzierzawy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
341 views39 pages

10 Aaa21290r

This document provides replacement part information for controllers used in elevator systems. It includes a table of contents listing the main components covered, drawings of relevant assemblies, and part numbers. Safety certification information and the responsible subject matter expert are also included.

Uploaded by

kędzierzawy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 39

Controller Spare Parts Leaflet

GEM, E311VF, MVS, 10-AAA21290R


HVS, and GMP (Mod) February 17, 2016 / Page 1 of 39

SERVICE ENGINEERING
Otis Elevator Company
Bloomfield, Connecticut USA
Unpublished Work—© Otis Elevator Co.; 2016
10-AAA21290R History
Leaflet Description
This leaflet provides replacement part information for the MVS, HVS, E311VF, GEM, and GMP (Mod.)
controller.
NOTE: The LMCSS PC board changed from using AMP male headers to WAGO connectors around 2/19/01
(refer to page 7).

Leaflet Revisions
Subject Matter
Date Revised Reason for Revision
Expert
Jeff Costley (Technical
February 1993 New Leaflet (under SPL No. 10-AAA21290C)
Writer)
November 1995 Ali Bozorgzadeh Update parts
March 1, 2000 Ali Bozorgzadeh Update part and artwork

May 20, 2003 John Dwyer Major update to recognize part changes.

September 5, 2003 John Dwyer Add LRUs for modernization product vintage AGA21290R
Add vintage information and change p/n of LMCSS PC board (see
May 4, 2006 John Doane
NOTE under leaflet Description)
November 1, 2006 John Dwyer Reflect parts changes from new vintages.

January 16, 2007 John Dwyer Correct p. 24, Ref. No. 2 from 400 to 1400
Corrected resistance value for ABA21305F1 on page 28; updated
December 10, 2007 Ali Bozorgzadeh
cross-references throughout the document.
Update ANSI Speed Check PCB p/n on pp. 7 and 18. Split page 18
April 27, 2009 Asif Hassan
to pages 18 and 19. Updated TOC pp. 4 and 5.
Add drawing where one may find the appropriate PVT-Controller
September 4, 2013 Ali Bozorgzadeh
cable (ABA174RH2).
November 6, 2013 Ali Bozorgzadeh Add relay to PC board drawing on page 22.

October 7, 2015 Ali Bozorgzadeh Corrected page references on pp. 30–32

February 17, 2016 Ali Bozorgzadeh Added p/n AAA21305DJ1 and NOTE 2 on p. 7 and p. 17

Related Drawings
Drawing No. Title Drawing No. Title
Assembly & Arrangement: AAA21290BY, Assembly & Arrangement: Drive
AAA21290R
GEM/MVS/HVS Controller AAA21305AM Panel
Assembly & Arrangement: AAA21290S, Assembly & Arrangement: Motion
AAA21290E
Operational Control Panel (OCP) AAA21305AK Control Panel (MCP)
Assembly & Arrangement: Power
AAA21290K Assembly & Arrangement: DBR AAA21290F
Supply
Assembly & Arrangement: Drive Assembly & Arrangement: DBR
AAA21290J AAA21290AN
Panel (HVS)
AAA174RH PVT/Encoder Cable
(Continued on next page)

Page 2 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


History (Continued) 10-AAA21290R

Related Documents
Document ID Title Document ID Title
Variable Frequency
SPL 10-AAA21290AK SPL 09-JAA25402AAH OVF416 (DBSS)
(OVF30) 70-210A Drives
Drive Replacement on
SWP N-1.1.12.0-2 SPL 09-JAA25402AAK OVF428 (CSA Version)
Existing Site
Transformer (Enclosed
SPL 09-JAA25402AAM OVF428x (DBSS) SPL 10-AAA21799H for Non-Regenerative
Drives)
MCSS 5 VDC Voltage
SPL 10-AAA21799G Transformer (Enclosed) TIP 1.1.7.1-11
Regulator Upgrade
Subject Matter Expert
Name Department
Ali Bozorgzadeh OSC Service Engineering
About Spare Parts Leaflets…
This document lists the lowest replaceable units (LRUs) for the standard version of the product. The LRUs are chosen by a
team of Otis associates representing engineering and manufacturing.
While goal of this document is to make parts identification as easy as possible, the document cannot be all-inclusive. Elevator
and escalator contracts classified as “special” or “custom” are not addressed here. For such contracts, please refer to specified
information, the contract folder, TIPs, Field Education Articles, Construction Letters, etc. for further information.

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 3


10-AAA21290R Table of Contents

REF. No. PAGE No. DESCRIPTION


1 6 Drive Assembly, Integral (see note above)
2 7–16 Motion Panel
3 17–23 Operation Control Panel
4 24–27 Power Supply Panel
5 28–29 Dynamic Braking Resistor Panel, Integral (see note above)
6 30–32 Drive Panel
7 33–36 Transformers
8 37 Door Lock Bypass Relays and Switches
(Continued on next page)

Page 4 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Table of Contents (cont.) 10-AAA21290R

REF. No. PAGE No. DESCRIPTION


1 6 Drive Assembly, Integral (see note above)
2 7–16 Motion Panel
3 17–23 Operation Control Panel
4 24–27 Power Supply Panel
5 28–29 Dynamic Braking Resistor Panel, Integral (see NOTE above)
6 30–32 Drive Panel
7 33–36 Transformers and Current Harmonic Filter Choke
8 37–38 Door Lock Bypass Relays and Switches
9 Electro Magnetic Filter Assembly
10 Voltage Transfer Relay and Socket
39
11 Position Indicator and Test Selector Switch Panel
12 Suppressor, Brake Coil (GMP only)

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 5


10-AAA21290R Drive Assemblies

AAA–ACA ADA–AHB
21290R 21290R
REF. NO. PART No. DESCRIPTION
AAA21290AK1
ABA21290AK1
10 KHz
ACA21290AK1
ADA21290AK1
--- 70 Amp
AAA21290AK2
ABA21290AK2
5 KHz
ACA21290AK2
ADA21290AK2
AAA21290Y1
ABA21290Y1
ACA21290Y1 10 KHz
1 AAA21290BJ1
(see 90 Amp
AAA21290BJ2
NOTE 1)
ABA21290BJ2
5 KHz
ACA21290BJ2 + ABA270CV3
(See Note 2) Drive Assembly
AAA21290M1
ABA21290M1
ACA21290M1 10 KHz
AAA21290BA1
120 Amp
AAA21290BA2
ABA21290BA2
5 KHz
ACA21290BA2 + ABA270CV3
(See Note 3)
AAA21290BM2
ABA21290BM2 10 KHz
2 ACA21290BM2
(see --- 210 Amp
AAA21290BM1
NOTE 1)
ABA21290BM1 5 KHz
ACA21290BM1
NOTE 1: Also see SPL 10-AAA21290AK, Variable Frequency (VF) Drive and SWP N-1.1.12.0-2, drive
replacement on existing site.
NOTE 2: ABA270CV3 mounting adaptor is required only when replacing drive types A_A21290Y1 with
ACA21290BJ2.
NOTE 3: ABA270CV3 mounting adaptor is required only when replacing drive types A_A21290M1 with
ACA21290BA2.

Page 6 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Motion Panel, LMCSS 10-AAA21290R

ALL VINTAGES
REF.
No. PART No. DESCRIPTION
AAA21380M1
1 Assembly, Module, ANSI Speed Check ASCB
AAA21380M3
2 JAA00718AAA001 Battery BAT1 (on Ref. 3)
PC Board, Chime (w/luxury hall lanterns and rear
ABA26800ABL001
doors only)
3 ---
Chime Replacement Kit (w/luxury hall lanterns and
AAA21305DJ1
rear doors only) NOTE 2
JBA26801AAF002 Connectors
JDA26801AAF002
JEA26801AAF002 PC Board, Motion Control
4 AMP LMCSS
JFA26801AAF002 (see NOTE 1)
JGA26801AAF002
JGA26801AAF105 WAGO
AAA26800GG1
5 PC Board, ANSI Speed Check ASCB
AAA26800ARG1
6 CAA623C2 Counter ---
NOTE 1: AFA21290R and later controllers will be equipped with a motion control PC board with either AMP
or WAGO connectors, depending on production date. Replace with same type as existing.
NOTE 2: TIP 4.5-8 to replace the obsolete ABA26800ABL chime board with the AAA21305DJ chime
replacement kit.
(Continued on next page)

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 7


10-AAA21290R Motion Panel, LMCSS

ALL VINTAGES
REF.
No. PART No. DESCRIPTION
1 AAA375CF7 Fuse, 2 A, 250 V, Fast Acting F1 (on Ref. 4)
2 AAA375BT17 Fuse, 1 A, 250 V, Fast Acting F1 (on Ref. 3)
Software, Baseline LMCSS
3 --- U37 on Ref. No. 4
(p/n AAA30085AAA1), see NOTE
Software, Default Contract Parameters (p/n
4 --- U44 on Ref. No. 4
AAA30085AAA2), see NOTE
CUIB, CDIB, CCIB, LSP
5 AAA635L3 Switch, Pushbutton
Reset
6 AAA636E6 Switch, Selector CIS
7 AAA623AF3 Timer, 3 to 30 Seconds DBT
NOTE: Contact your OSC Customer Service Representative for latest revision.

Page 8 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Motion Panel, MCSS 10-AAA21290R

_ _ _21290R
AFA, AGA, AGB,
AHA, AHB
REF. No. PART No. DESCRIPTION SYMBOL
1 ACA26800ABB002 Board, MCSS I/O ---
ABA26800ABA001
2 Board, MCSS Processor ---
ABA26800ABA002
3 AAA174KV2 Cable, Ribbon ---
4 226DR11 Capacitor, 22000 µF, 60 V C4
5 226DR12 Capacitor, 120000 µF, 25V C5
6 AAA612AE1 Diode, 3 A, 20 V, (1N5820) D1
7 AAA375BT18 Fuse, 3 A, 250 V Fast Acting F1, F2 on Ref. No.1
8 AA431AF18 Lock, Key CIS
9 230BS1 Rectifier, Bridge, 25 A BR6
AAA00616AAG001 Regulator, 5 V (see TIP 1.1.7.1-11)
10 ---
AAA27076BS1
11 AAA232GJ56 Resistor, 1.5 K Ω, 5 W R20
12 AAA232FR2 Resistor, 25 Ω, 25 W R21
Software, Baseline MCSS (p/n U45 and U56 on Ref.
13 ---
AAA30045AAA1), see NOTE No. 2
Software, Default Contract Parameters (p/n U48 and U59 on Ref.
14 ---
AAA30045AAA2), see NOTE No. 2
CUIB, CDIB, CCIB,
15 AAA635L3 Switch, Pushbutton
LSP RESET
ABA636A5 Switch, Rotary (general location, not shown) CIS
16 177DE3 Switch, Selector (general location, not
CIS
AAA636E6 shown)
NOTE: Contact your OSC Customer Service Representative for latest revision.

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 9


10-AAA21290R Motion Panel Components

REF. No. PART No. DESCRIPTION SYMBOL


AAA613CX201 Auxiliary Contact, 2 NO
AAA613CX203 Auxiliary Contact, 2 NC
AAA613CX205 Auxiliary Contact, 3 NO, 1 NC
AAA613CX207 Auxiliary Contact, 1 NO, 3 NC See p. 12 and
p. 13 (NAO)
1 AAA613DL71 Auxiliary Contact, 3 NO, 1 NC
p. 14 (CEN)
AAA613DL72 Auxiliary Contact,, 2 NO, 2 NC p. 15 (AUS)
AAA613DL73 Auxiliary Contact,, 2 NO
AAA613DL74 Auxiliary Contact, 1 NO, 1 NC
AAA613DL75 Auxiliary Contact, 2 NC
AAA613DL80 Coil Driver, 24 VDC, 5A Contact See
2 AAA613DL81 Coil Driver, 24 VDC, Solid State p. 13 (NAO)
p.14 (CEN)
AAA638AF13 Contactor, 120 VAC, 3 NO Main, 1 NO Auxiliary
3 See pp. 12 & 13
AAA638AF15 Contactor, 120 VAC, 3 NO Main, 1 NO, 1 NC Aux.
AAA612AF3 Diode, Suppressor for LVC (CEN). Used with ---
4
AAA613DL91 relay, ODZ (CEN) and OOS (AUS)
(Continued on next page)

Page 10 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Motion Panel Components 10-AAA21290R

REF.
No. PART No. DESCRIPTION SYMBOL
AAA613CX104 Relay, 120 VAC, 4NO
AAA613CX105 Relay, 120 VAC, 3NO, 1NC
AAA613CX106 Relay, 120 VAC, 2NO, 2NC
AAA613CX114 Relay, 24 VDC, 3NO, 1NC
AAA613DL29 Relay, 120 VAC, 4NO
See p. 12 &
1 AAA613DL30 Relay, 120 VAC, 3NO, 1NC
p. 13 (NAO)
AAA613DL31 Relay, 120 VAC, 2NO, 2NC
p. 14 (CEN)
AAA613DL40 Relay, 120 VAC, 2NO, 3NC
p. 15 (AUS)
AAA613DL42 Relay, 120 VAC, 5NC
AAA613DL91 Relay, 24 VDC, 3NO, 1NC
AAA613DL105 Relay, 110 VDC, 3NO, 1NC
AAA613CZ8 Relay, 24 VDC, 4 Form C
2
AAA613CZ10 Relay, 12 VDC, 4 Form C
AAA613CX302 Suppressor (varistor), for LVC1 (CEN), w/AAA613CX114 Relay
Suppressor (diode). Used on all 24 VDC AAA613CX type relays
AAA613CX304
except LVC1.
3 Suppressor (RC with varistor), Used on all 120 VAC AAA613CX ---
AAA613CX305
type relays.
Suppressor (RC). Used on all 120 VAC AAA613DL type relays
AAA613DL61
that do not use coil driver.
ODZ (CEN),
4 618AE2 Socket, Relay
OOS (AUS)
P, R, S, T,
5 AAA303EP199 Terminal Block w/Relay, 24 VDC, 1 Form C
V, X
6 AAA623AA7 Timer (optional on AFA through AHB21290R controllers only) ---

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 11


10-AAA21290R Motion Panel Relays NAO, CEN, & AUS

Relays contactors and auxiliary contacts common to NAO, CEN, and AUS controllers including B44 and DLB
features. See pages 9 and 10 for descriptions.
RELAYS:
_ _ _21290R CONTROLLER
SYMBOL AAA ABA ACA ADA AEA AFA AGA–AHB
RELAY PART NUMBER: AAA613_ _ _ _ _
ADZ
AUD CX105 DL30
C
CIO --- DL40
D CX105 DL30
DBR CX114 DL105 ---
DFLR
DOLR ---
CX106 DL31
DSR1
DSR2
DZ CX105 DL30
EBLX --- DL30
EBRX --- DL31
EES CX104 DL29
ETP2 --- DL31
ETSC CX104 DL29
GDS CX105 DL30
GSR1
--- CX106 DL31
GSR2
LB CX105 DL30 SEE CONTACTORS BELOW
LSP CX104 SEE CONTACTORS BELOW
OSC --- DL30
RDOLR --- CX106 DL31
RGR --- DL31 ---
SC CX104 DL29
U CX105 DL30
CONTACTORS:
_ _ _21290R CONTROLLER
SYMBOL AAA ABA ACA ADA AEA AFA AGA–AHB
CONTACTOR PART NUMBER: AAA638_ _ _ _ _
BMR AF13 ---
---
BSR AF15
LB See Relays Above AF15
LSP See Relays Above AF15
AUXILIARY CONTACTS:
_ _ _21290R CONTROLLER
SYMBOL AAA ABA ACA ADA AEA AFA AGA–AHB
AUXILIARY CONTACT PART NUMBER: AAA613_ _ _ _
AUD --- DL72
DSR1
--- DL72
DSR2
EES --- CX205 DL71 ---
GDS --- DL71
GSR1
--- DL72
GSR2

Page 12 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Motion Panel Relays (NAO only) 10-AAA21290R

Relays, contactors, auxiliary contacts, and coil drivers for NAO controllers only, including B44 and DLB
features. See pages 10 and 11 for descriptions.

RELAYS:
_ _ _ 21290R CONTROLLER
SYMBOL AAA ABA ACA ADA AEA AFA AGA–AHB
RELAY PART NUMBER: AAA613_ _ _ _
ETP CX114 DL30 DL31
INS CX105 CX106 DL31
CONTACTORS:
_ _ _ 21290R CONTROLLER
SYMBOL AAA ABA ACA ADA AEA AFA AGA–AHB
CONTACTOR PART NUMBER: AAA638_ _ _ _
EBL
--- AF15
EBR
UD --- AF15
AUXILIARY CONTACTS:
_ _ _ 21290R CONTROLLER
SYMBOL AAA ABA ACA ADA AEA AFA AGA–AHB
AUXILIARY CONTACT PART NUMBER: AAA613_ _ _ _
ADZ CX207 CX205 DL71 DL72
D --- DL73 ---
DZ CX207 CX205 DL71 DL72
INS ---
DL72
LB --- DL73
LSP --- CX207 DL72
SC CX207 CX205 DL71
U --- DL73 DL72
COIL DRIVER:
_ _ _ 21290R CONTROLLER
SYMBOL AAA ABA ACA ADA AEA AFA AGA–AHB
COIL DRIVER PART NUMBER: AAA613_ _ _ _
ETP DL80 DL81 DL81
ETP2 --- DL81
---
DOLR
--- DL80 DL81 DL81
RDOLR

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 13


10-AAA21290R Motion Panel Relays (CEN only)

Relays, auxiliary contacts and coil drivers for CEN controllers only. See pages 10 and 11 for descriptions.

RELAYS:
___21290R CONTROLLER
SYMBOL AAA ABA ACA ADA AEA AFA AGA–AHB
RELAY PART NUMBER: AAA613 _ _ _ _
A CX106 DL31 DL30 or DL31 DL30 DL31
C1 --- DL30
ETP CX105 DL30 DL31
INS CX106 DL42
INSX --- DL30
LBP --- CX105 DL30 ---
LV1
DL30
LV2
CX114
LVC DL31
DL91
LVC1 ---
ODZ CZ10 ---
TRO
--- DL31
TROX
AUXILIARY CONTACTS:
_ _ _ 21290R CONTROLLER
SYMBOL AAA ABA ACA ADA AEA AFA AGA–AHB
AUXILIARY CONTACT PART NUMBER: AAA613 _ _ _ _
ADZ CX205 DL71
D CX203 DL75 DL72
DZ CX205 DL71
INS CX207 --- DL74 DL71
INSX --- DL72
---
LV1
CX201 DL73 ---
LV2
LVC --- DL71
SC --- DL71
U CX203 DL75 DL72
COIL DRIVER:
_ _ _ 21290R CONTROLLER
SYMBOL AAA ABA ACA ADA AEA AFA AGA–AHB
COIL DRIVER PART NUMBER: AAA613 _ _ _ _
LV1
DL80 DL81
LV2 --- DL81
LVC --- DL80 DL81

Page 14 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Motion Panel Relays (AUS only) 10-AAA21290R

Relays and auxiliary contacts for AUS controllers only. See pages 10 and 11 for descriptions.

RELAYS:
___21290R CONTROLLER
SYMBOL AAA ABA ACA ADA AEA AFA AGA–AHB
RELAY PART NUMBER: AAA613 _ _ _ _
DLR
DL30
ECR
ETP DL30 DL31
INA CX105
INB ---
DL30
NTB
NTT
ODZ CZ8 ---
OOS --- CZ8
AUXILIARY CONTACTS:
_ _ _ 21290R CONTROLLER
SYMBOL AAA ABA ACA ADA AEA AFA AGA–AHB
AUXILIARY CONTACT PART NUMBER: AAA613 _ _ _ _
ADZ CX205 DL71
C CX201 DL73
---
D CX203 DL75
DZ --- CX205 DL71
INA CX203 DL75 DL72
SC --- DL71
U CX203 DL75 ---

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 15


10-AAA21290R Motion Panel Components

AAA21290R AFA21290R
ABA21290R AGA21290R
ACA21290R AGB21290R
ADA21290R AHA21290R
AEA21290R AHB21290R
REF.
No. PART No. DESCRIPTION SYMBOL
Diode, 1 A, 1000 V, 1N4007 (ABA21290R
1 AAA612T7 --- D2 – D5
CEN controllers only)
2 AAA232HR43 Resistor, 2200 Ω, 2 W R3, R4
3 AAA232FT55 Resistor, 180 Ω, 1/2 W (AUS controllers only) R5
Resistor, 1000 Ω, 1/4 W (ACA21290R CEN
4 AAA232FV73 R6, R7
controllers only)
Resistor, 30 Ω, 3 W (ACA21290R CEN
5 AAA232FC24 R8, R9
controllers only)
6 AAA303EP1 Terminal ---
7 AAA303EP42 Terminal ---
8 AAA303EP99 AAA303EP98 Terminal ---

Page 16 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Operational Control Panel 10-AAA21290R

REF. No. PART No. DESCRIPTION SYMBOL


1 GAA718C1 Battery, 3 V, Lithium BAT1 on Ref. No. 3
Board, Chime (with Luxury hall lanterns only;
ABA26800ABL001 one board with front doors on all controllers, two
boards with front and rear doors)
2 Kit, Chime Replacement (w/ Luxury hall lanterns ---
AAA21305DJ1 only; one kit w/ front doors on all controllers, two
kits w/ front and rear doors) NOTE 2
GCA21270A3
GDA21270A3
3 GEA21270A3 Board, Ring Car II RCB II
GFA21270A3
GHA21270A3
4 CAA623C2 Counter ---
GO375AF22
5 Fuse, 2 A, 250 V, Time Delay F1, F2 on Ref. No. 3
AAA375BY8
375P1
6 Fuse, 1 A, 250 V, Fast Acting F1 on Ref. No. 2
AAA375BT17
Software, Baseline OCSS (p/n U37, U53 on Ref.
7 ---
AAA30005AAA1), see NOTE No. 3
Software, Default Contract Parameters (p/n U34, U49 on Ref.
8 ---
AAA30005AAA2), see NOTE 1 No. 3
NOTE 1: Contact your OSC Customer Service Representative for latest revision.
NOTE 2: TIP 4.5-8 to replace the obsolete ABA26800ABL chime board with the AAA21305DJ
chime replacement kit.

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 17


10-AAA21290R Operational Control Panel

_ _ _ 21290R
AAA, ABA ACA–AGA AGB–AHB
REF.
NO. PART No. DESCRIPTION SYMBOL
AAA21380M1 New Equip. Systems
--- AAA21380AN1 Assm. ANSI
AAA21380M3 (set J5 to GG1)
1 Speed
AAA21380M2 Check GMP w/rpm <721 only
--- AAA21380AN3
AAA21380M3 (set J5 to GG2)
ASCB
AAA26800GG1 New Equip. Systems
--- PC Board,
AAA26800ARG1 (set J5 to GG1)
2 ANSI Speed
AAA26800GG2 Check GMP w/rpm <721 only
---
AAA26800ARG1 (set J5 to GG2)
GUPC,
3 623T1 AAA623AG1 Clock, Weekly Timer
GDPC
AAA613DL80
--- Coil, Driver LR
4 --- AAA613DL81
--- AAA303EP199 Terminal Block w/Relay, 24 VDC L
Continued on Next Page

Page 18 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Operational Control Panel 10-AAA21290R

_ _ _ 21290R
AAA, ABA ACA–AGA AGB–AHB
REF.
NO. PART No. DESCRIPTION SYMBOL
9693F2 GDA26800AL1
5 GBA26800AL1 GEA26800AL1 Module, Switchover SOM
GCA26800AL1
AAA613CX115 --- Relay, 24 VDC, 2 NO, 2 NC
6 LR
--- AAA613DL31 Relay, 120 VAC, 2 NO, 2 NC
GNP,
AAA613CZ8 Relay, 24 VDC, 4 Form C
7 --- ODZ(AUS), PFR
AAA613CZ10 Relay, 12 VDC, 4 Form C ODZ(CEN)
8 --- 618AE2 Socket, Relay GNP, ODZ, PFR
9 AAA613CX304 --- AAA613DL61 Suppressor, Diode LR
10 --- AAA612AF3 Suppressor, Diode GNP, ODZ, PFR

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 19


10-AAA21290R Operational Control Panel

REF. NO. PAGE DESCRIPTION


1 Assembly, Remote Station, RS4, RS5
2 21 Module, Filter
3 & Module, Multi Drop Buffer
4 22 Module, Seismic Operation
5 Module, Standby Power Operation
6 23 Terminal Blocks and Terminal Block Mounted Components

Page 20 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Operational Control Panel 10-AAA21290R

AAA21290R ACA thru AHB


ABA21290R 21290R
REF.
No. PART No. DESCRIPTION SYMBOL
7145AY1 --- Assembly, Remote Station, RS4
C1RS,
1 AAA26810A1
Assembly, Remote Station, RS5 C4RS – C6RS
AAB26810A1
A9693C4 --- Board, Remote Station, RS4
GBA23550D1
2 GCA23550D1 C1RS – C6RS
GDA23550D1 Board, Remote Station, RS5
GEA23550D10
GFA23550D10
3 AAA26800KP1 Board, Filter ZB1 – ZB6
4 --- AAA26800MJ1 Board, Multi Drop Buffer MDBB
5 AAA21380D1 Module, Filter ZB1 – ZB6
6 --- AAA21380AE1 Module, Multi Drop Buffer MDBB

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 21


10-AAA21290R Operational Control Panel

AAA21290R ACA thru AHB


ABA21290R 21290R
REF. No. PART No. DESCRIPTION SYMBOL
A9693C4 --- Board, Remote Station, RS4
GBA23550D1
1 GCA23550D1 C1RS–C6RS
GDA23550D1 Board, Remote Station, RS5
GEA23550D10
GFA23550D10
AAA26800KT1
2 Board, Seismic Operation EQIB
ABA26800KT1
AAA26800KS1
3 Board, Standby Power SPIB
ABA26800KS1
AAA21380E1
4 AAB21380E1 Module, Seismic Operation EQIB
ABB21380E1
AAA21380F1
5 AAB21380F1 Module, Standby Power SPIB
ABB21380F1
6 AAA613CZ2 Relay, 24 VDC, 4 Form C EQIB

Page 22 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Operational Control Panel 10-AAA21290R

AFA21290R
AGA21290R
ACA21290R AGB21290R
AAA21290R ADA21290R AHA21290R
ABA21290R AEA21290R AHB21290R
REF.
No. PART No. DESCRIPTION SYMBOL
AAA612AK1 D1
--- AAA612AK1 D6 & 7(CEN),
1 Diode, 3 A, 600 V, (1N5406)
D9
--- AAA612AK1 D10, D11
2 --- AAA612T7 Diode, 1 A, 1000 V (1N4007) D2 – D5(CEN)
3 --- AAA612AX6 Diode, Zener, 12 V, 5 W Z1
4 --- AAA26810D1 Module, Rope Stretch
RSI
Indicator
AAA232FN51 --- Resistor, 120 Ω, 1 W RLR
RLR, R6 &
5 R7(CEN),
--- AAA232FV73 Resistor, 1 K Ω, 1/4 W
R10(AUS),
R11, R12
6 --- AAA232FC24 Resistor, 30 Ω, 3 W R8(CEN)
--- AAA232GJ33 R14
7 Resistor, 180 Ω, 5 W
--- AAA232GJ33 R13
9 AAA303EP1 Terminal ---
10 AAA303EP42 Terminal ---
11 --- AAA303EP99 AAA303EP98 Terminal ---
12 --- AAA303EP126 Terminal ---

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 23


10-AAA21290R Power Supply Panel

REF. No. PART No. DESCRIPTION SYMBOL


CB4, CB12 (AUS, CEN), CB13,
AAA637C2 Breaker, Circuit, 2.5 A, 1-Pole, Short Delay
CB16
CB3 (see NOTE), CB5 - CB7,
AAA637C8 Breaker, Circuit, 5.0 A, 1-Pole, Long Delay
CB12 (B44), CB14, CB17
AAA637C10 Breaker, Circuit, 10.0 A, 1-Pole, Long Delay CB8, CB15
Breaker, Circuit, 7.5 A, 1-Pole, Long Delay,
1 AAA637C15 CB3 (see NOTE)
(high pulse) Plus Inertial Delay
AAA637C16 Circuit Breaker 2.5 A, 1-Pole, Long Delay CB2, CB13 (AUS), CB18 (AUS)
Breaker, Circuit, 5.0 A, 1-Pole Long Delay (high
AAA637C17 CB1
pulse) plus Inertia Delay, Red Handle
Breaker, Circuit, 0.5 A, 1-Pole, Instantaneous
AAA637C18 CB9 - CB11
DC
Breaker, Circuit, 5.0 A, 2-Pole, Long Delay,
AAA637C19 CB1
Auxiliary Switch, w/Red Handle
2
Breaker, Circuit, 2-Pole, (Pole 1 = 2 A,
AAA637C23 CB21
Pole 2 = 5 A, Long Delay)
NOTE: CB3 part number depends upon controller production date. Replace with same type as existing.

Page 24 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Power Supply Panel 10-AAA21290R

AAA21290R–
AHA21290R AHB21290R
REF. SYSTEM
No. PART No. DESCRIPTION VOLTAGE SYMBOL
AAA637F9 Breaker, Circuit, 2.0 A, 2-Pole ≥ 380 V CBP
1 AAA637F11 --- Breaker, Circuit, 3.0 A, 2-Pole ≥ 380 V CBM
AAA637F12 Breaker, Circuit, 5.0 A, 2-Pole 200-240 V CBM, CBP
AAA375BK29 Fuse, 4 A, Time Delay ≥ 440 V FM (New
AAA375BK39 Fuse, 10 A, Time Delay < 440 V Equipment)
AAA375BK35 Fuse, 7 A, Time Delay ≥ 440 V
2 --- AAA375BK41 Fuse, 15 A, Time Delay, FM (GMP)
< 440 V
AAA375BW37 (see NOTE)
AAA375BK21 Fuse, 2 A, Time Delay ≥ 440 V
FP
AAA375BK29 Fuse, 4 A, Time Delay < 440 V
3 --- AAA346AYQ9 Fuse Cover (see NOTE) < 440 V FM (GMP)
FM (New
---
AAA653D1 Fuse Holder, 2-Pole Equipment)
≥ 440 V
4 ---
AAA653D1 Fuse Holder, 2-Pole, FM (GMP)
< 440 V
AAA653H2 (see NOTE)
AAA653D1 Fuse Holder, 2-Pole --- FP
FM (New
---
Equipment)
5 --- AAA180FK2 Fuse Puller
≥ 440 V FM (GMP)
--- FP
NOTE: Order Kit AAA27076CY1 for fuses, holder, cover, label and hardware needed to update FM fuses in GEM
Modernization Product controllers with system voltage < 440 V, see TIP 1.1.11.0-1.

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 25


10-AAA21290R Power Supply Panel

REF. No. PART No. DESCRIPTION SYMBOL


1 230BS3 Bridge, Diode, 600 V, 25 A BR1, BR2, BR5-BR7
226EJ1 Capacitor, 19 K µF, 60 VDC C2, C3
2 226DR1 Capacitor, 1400 µF, 450 V C1
AAA226FN5 Capacitor, 2 K µF, 200 W VDC C-LVC (CEN)
3 AAA232FJ2 Resistor, 4 K Ω, 10 W ±1% (for capacitor C1) R1
4 232AE1 Resistor, 250 Ω, 5 W, Capacitor Mtg. R-LVC (CEN)
AAA605AA13 Suppressor, Transient 30 V RMS SA2, SA3
5
AAA605AA39 Suppressor, Transient 175 V RMS SA1

Page 26 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Power Supply Transformers 10-AAA21290R

_ _ _ 21290R
REF.
AAA ABA, ACA ADA, AEA* AEA*–AHB
NO.
PART No. SYSTEM VOLTS** SYMBOL
AAA225GG6 AAA225JC3 AAA225JC8 200 to 240 V
AAA225GG4 AAA225JC1 AAA225JC6 380 to 420 V
AAA225GG5 AAA225JC2 AAA225JC7 440 to 500 V TRM
AAA225GG7 AAA225JC4 AAA225JC9 550 to 625 V (new
--- AAA225GG8 AAA225JC5 AAA225JC10 395 to 435 V (AUS) equipment
--- AAA225HK1 AAA225HZ1 --- 200 to 240 V (B44) systems)
--- AAA225HZ2 --- 440 to 500 V (B44)
--- AAA225HZ3 --- 550 to 625 V (B44)
AAA225LC1
110 V Brake
1 ABA225LC1 440–
AAA225LD1 550 V
230 V Brake
ABA225LD1
AAA225LC2
110 V Brake
ABA225LC2 550– TRM
---
AAA225LD2 600 V (GMP)
230 V Brake
ABA225LD2
AAA225LC3 200–
110 V Brake
ABA225LC3 240 V
AAA225LD3 (see
230 V Brake
ABA225LD3 NOTE)
AAA225GF6 ABA225GF6 200 to 240 V
AAA225GF4 ABA225GF4 380 to 420 V
AAA225GF5 ABA225GF5 440 to 500 V
2 TRP
AAA225GF7 ABA225GF7 550 to 625 V
--- AAA225HE1 ABA225HE1 395 to 435 V (AUS)
--- AAA225HE2 ABA225HE2 440 to 500 V (AUS)
* Transformer used is dependent upon AEA21290R controller production date. Replace with same type as existing.
** In controllers with Electromagnetic Filter (see p. 35) or TRL transformer (see p. 32). The TRM and TRP transformers
are the type specified for 440 to 500 V system voltage for the applicable A_A prefix controller.
NOTE: When TRM transformer AAA225LC3 or LD3 is replaced with ABA version, also update FM fuses with kit
AAA27076CY1 (see p. 24).

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 27


10-AAA21290R Dynamic Braking
Resistor Panel Components

REF. No. PART No. DESCRIPTION SYMBOL


1 252B1 Bar, Bus ---
P727A1
2 AAA6091AQ1 Fan, 115 VAC, 50/60 Hz ---

P727A2
3 AAA6091AQ2 Guard, Fan ---

4 180AD1 Holder, Resistor ---


5 AAA617K101 Holder, Resistor (ABA & ACA21290R controllers only) R2
6 2700CAA4 Kit, Fan with Guard and Hardware ---
232AA1 Resistor, Power, 1.32 Ω, 700 W, 10 in. L NOTE:
232AA2 Resistor, Power, 1.65 Ω, 700 W, 10 in. L Select replacement based
on p/n or resistance value
7 232AA3 Resistor, Power, 2.08 Ω, 700 W, 10 in. L DBR
stamped on the end of
232AA4 Resistor, Power 2.61 Ω, 700 W, 10 in. L existing resistor.
232AA5 Resistor, Power, 3.82 Ω, 700 W, 10 in. L
Resistor, Variable, 10 Ω, 225 W, 10.5 in. L
8 AAA617K6 R2
(ABA & ACA21290R controllers only)

Page 28 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Dynamic Braking 10-AAA21290R

Resistor Panel Components

_ _ _21290R
ADA–AHB
REF. No. PART No. DESCRIPTION SYMBOL
1 252B1 Bar, Bus ---
2 AAA6091AJ1 Fan ---
3 AAA384YE1 Guard, Fan ---
4 180AD1 Holder, Resistor ---
Resistor, Power, 23.1 Ω, 980 W, NOTE:
ABA21305F1
14 in. L Select replacement
Resistor, Power, 2.85 Ω, 1300 W, based on p/n or
5 ABA21305F2 resistance value DBR
14 in. L
stamped on the end of
Resistor, Power, 2.26 Ω, 1300 W, existing resistor.
ABA21305F3
14 in. L

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 29


10-AAA21290R Drive Panel Components

REF. No. PART No. DESCRIPTION SYMBOL


1 AAA617K101
Clip, Resistor Mounting R2
2 AAA617H101
3 AAA638AA12 Contactor, 3 Pole, 120 VAC Coil, 70 A
2 NO, 2 NC Aux. Contacts M(AUS), 1M & 2M(CEN)
4 AAA638AA29 90 A
5 AAA375CE5 Fuse, 1.25 A, 600 V FBB
6 AAA375BN24 Fuse, 15 A, 600 V FD1-FD3, FRD1-FRD3
7 AAA375BK39 Fuse, 10 A, 600 V, Time Delay FDO
8 AAA653D2 Holder, Fuse, 3 Pole ---
9 230BS3 Rectifier, Bridge BR3, BR4, BR5
10 AAA617K6 Resistor, 10 Ω, 225 W
R2
11 AAA232FR3 Resistor, 50 Ω, 25 W
12 AAA00605AAA014 Suppressor M(AUS), 1M & 2M(CEN)
13 --- Circuit Breaker (see p. 32) CBR

Page 30 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Drive Panel Components 10-AAA21290R

REF. No. PART No. DESCRIPTION SYMBOL


GAA243AJ1 with 90 Amp Drive
Choke, Current
1 GAA243AJ2 with 120 Amp Drive CCC
Compensating
GAA243AJ3 with 210 Amp Drive
2 AAA617H101 Clip, Resistor Mounting R2
AAA638AA29 Contactor, 3 Pole, 120 VAC Coil,
3 M (AUS), 1M & 2M (CEN)
AAA638AA31 2 NO, 2 NC Aux. Contacts
Contactor, 3 Pole, 120 VAC Coil,
4 AAA638AF13 BMR
1 NO Aux Contacts
5 AAA375CE5 Fuse, 1.25 A, 600 V FBB
AAA375BN24 Fuse, 15 A, 600 V, w/HPLIM Door
Operator
6 FD1-FD3, FRD1-FRD3
Fuse, 3.5 A, 600 V, Time Delay,
AAA375BK28
w/DO2000 Door Operator
7 AAA375BK39 Fuse, 10 A, 600 V, Time Delay FDO
8 AAA653D2 Holder, Fuse, 3 Pole ---
9 230BS3 Rectifier, Bridge BR3, BR4
10 AAA232FR3 Resistor, 50 Ω, 25 W R2
11 AAA613DL61 BMR
Suppressor
12 AAA00605AAA014 M (AUS), 1M & 2M (CEN)
13 --- Circuit Breaker (see p. 32) CBR

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 31


10-AAA21290R Drive Panel Components

REF. No. PART No. DESCRIPTION DUTY SYMBOL


GEM: All Duties
MVS: 2035, 2535, 2040,2540,
AAA637G3 Breaker, Circuit, 30 Amp
3035, 3040, 3535
GMP: 70 A Drive
MVS: 3550, 5035
AAA637G4 Breaker, Circuit, 50 Amp HVS: 4050
GMP: 120 A Drive
HVS: 4550, 5050, 2570, 2080
AAA637G5 Breaker, Circuit, 60 Amp
29CT: 8020
1
(see ref. 13 on HVS: 3070, 3570, 4070, 2580, CBR
pp. 30 and 31) 3080, 3580
AAA637G6 Breaker, Circuit, 77 Amp 29CT:10020, 12020, 6035,
7035, 8035
GMP: 210 A Drive
MVS: 2545, 2550, 3045,
3050, 3540, 3545, 4035,
4535
AAA637G7 Breaker, Circuit, 40 Amp
HVS: 2050, 2070, 2550, 3050,
3550
GMP: 90 A Drive

Page 32 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Controller-Mounted Drive Transformer 10-AAA21290R

_ _ _ 21290R
AAA, ABA,
ACA, ADA ADA–AHB
POWER SUPPLY
VOLTS PART No. TRANSFORMER
SYSTEM DUTY (NOTE 1) HZ (NOTE 2) TYPE / KVA
60 AAA225GW1 ---
Isolation, 20 KVA
50 AAA225GW3 ---
2035 204-240
--- AAA225JK5
2040 50/60 Auto, 25.7 KVA
ABA225JK5
2535
2540 60 AAA225GV3 ---
Auto, 20 KVA
3035 50 AAA225GV5 ---
360-420
AAA225JK2
50/60 Auto, 25.7 KVA
ABA225JK2
60 AAA225GW1 ---
Isolation, 20 KVA
GEM 50 AAA225GW3 ---
204-240
3040 --- AAA225JK6
3535 50/60 Auto, 39 KVA
ABA225JK6
3540
4035 60 AAA225GV3 ---
Auto, 20 KVA
4535 50 AAA225GV5 ---
360-420
AAA225JK3
50/60 Auto, 39 KVA
ABA225JK3
AAA225GV1 --- Auto, 20 KVA
ALL 545-605 60 --- AAA225JK1
Auto, 66.5 KVA
ABA225JK1
NOTE 1: TRL transformer is not furnished with power supply of 440–480 V.
NOTE 2: See SPL 10-AAA21799H when transformer is mounted in separate enclosure.
(Continued on next page)

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 33


10-AAA21290R Controller Mounted Drive Transformer

_ _ _ 21290R
AAA, ABA,
ACA, ADA ADA–AHB
POWER SUPPLY
VOLTS PART No. TRANSFORMER
SYSTEM DUTY (Note 1) HZ (Note 2) TYPE / KVA
60 AAA225GW1 ---
Isolation, 20 KVA
50 AAA225GW3 ---
204–240
--- AAA225JK6
2035 50/60 Auto, 39 KVA
ABA225JK6
2040
2045 60 AAA225GV3 ---
Auto, 20 KVA
2050 50 AAA225GV5 ---
2535 360–420
AAA225JK3
3035 50/60 Auto, 39 KVA
ABA225JK3
3535
AAA225GV1 --- Auto, 20 KVA
545–605 60 --- AAA225JK1
Auto, 66.5 KVA
MVS / ABA225JK1
E311MV 60 AAA225GW2 ---
Isolation, 27 KVA
50 AAA225GW4 ---
2550 204–240
--- AAA225JK7
3045 50/60 Auto, 66.5 KVA
ABA225JK7
3050
3540 60 AAA225GV4 ---
Auto, 27 KVA
3545 50 AAA225GV6 ---
3550 360–420
--- AAA225JK4
4035 50/60 Auto, 66.5 KVA
ABA225JK4
4535
5035 AAA225GV2 --- Auto, 27 KVA
545–605 60 --- AAA225JK1
Auto, 66.5 KVA
ABA225JK1
60 AAA225GW2 ---
Isolation, 27 KVA
50 AAA225GW4 ---
204–240
--- AAA225JK7
50/60 Auto, 66.5 KVA
ABA225JK7
60 AAA225GV4 ---
Auto, 27 KVA
HVS ALL 50 AAA225GV6 ---
360–420
--- AAA225JK4
50/60 Auto, 66.5 KVA
ABA225JK4
AAA225GV2 --- Auto, 27 KVA
545–605 60 --- AAA225JK1
Auto, 66.5 KVA
ABA225JK1
NOTE 1: TRL transformer is not furnished with power supply of 440 to 480 V.
NOTE 2: See SPL 10-AAA21799H when transformer is mounted in separate enclosure.

Page 34 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Door Operator Transformers 10-AAA21290R

REF.
No. PART No. DESCRIPTION SYMBOL
Transformer, 3 Phase Autotransformer, with HPLIM Door
AAA225JN1
Operator and 440-480 V Power Supply
Transformer, 3 Phase Autotransformer, with HPLIM Door
AAA225JN2
Operator and 200-240 V Power Supply
1
Transformer, 3 Phase Autotransformer, with HPLIM Door
AAA225JN3
Operator and 380-440 V Power Supply
Transformer, 3 Phase Autotransformer, with HPLIM Door
AAA225JN4 TFD, TRD
Operator and 545-605 V Power Supply
Transformer, 1 Phase Isolation, with DO2000 Door Operator
AAA225JR4
and 200-240 V Power Supply
Transformer, 1 Phase Isolation, with DO2000 Door Operator
2 AAA225JR5
and 360-435 V Power Supply
Transformer, 1 Phase Isolation, with DO2000 Door Operator
AAA225JR6
and 440-600 V Power Supply

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 35


10-AAA21290R Current Harmonic Filter Choke

AEA21290R
AFA21290R
AGA21290R

REF. No. PART No. DESCRIPTION SYMBOL


GAA234AF1 Used with 70 or 90 A IGBT Drive
Choke, Current
1 GAA234AG1 Used with 120 A IGBT Drive CHF
Harmonic Filter
GAA234AH1 Used with 210 A IGBT Drive

Page 36 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Door Lock Bypass Relays & Switches 10-AAA21290R

ACA21290R AEA21290R
ABA21290R ADA21290R AFA21290R
REF.
NO. PART No. DESCRIPTION SYMBOL
Auxiliary contact, 2 NO, RDSR1, RDSR2,
1 --- AAA613DL72
2 NC RGSR1, RGSR2
Coil Driver, 24 VDC,
2 --- AAA613DL81 RDOLR
Solid State
Power Supply, 12 VDC
3 P621D4 621AE4 621AE6 ---
(CEN)
Relay, 120 VAC, 2 NO, BAS, BASX,
4 AAA613CX106 AAA613DL31
2 NC RDSR1, RDSR2,
RGSR1, RGSR2,
5 AAA613CX305 AAA613DL61 Suppressor TAS, TASX,
RDOLR
6 AAA636E1 Selector Switch CDBP, LDBP

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 37


10-AAA21290R Door Lock Bypass Relays & Switches

AGA21290R
REF.
NO. PART No. DESCRIPTION SYMBOL
RDSR1, RDSR2, RGSR1,
1 AAA613DL72 Auxiliary Contact, 2 NO, 2 NC
RGSR2
2 AAA613DL81 Coil Driver, 24 VDC, Solid State RDOLR
AAA447AP325 5 Positions 5P, 7P
Connector, Cage Clamp,
AAA447AP330 10 Positions 1P, 2P
Receptacle, Panel Mount
AAA447AP346 12 Positions 6P, ERO
3
AAA447AP257 5 Positions 5P, 7P
AAA176HH62 Connector, Cage Clamp, Plug 10 Positions 1P, 2P
AAA447AP261 12 Positions 6P, ERO
4 621AE6 Power Supply, 12 VDC (CEN) ---
BAS, BASX, RDSR1,
5 AAA613DL31 Relay, 120 VAC, 2 NO, 2 NC
RDSR2, TAS,
RGSR1, RGSR2, TASX,
6 AAA613DL61 Suppressor
RDOLR
7 AAA636E1 Selector Switch CDBP, LDBP

Page 38 February 17, 2016 Unpublished Work—Otis Elevator Co., 2016


Electro Magnetic Filter Assembly 10-AAA21290R

_ _ _21290R

AEA–AHB

REF. No. PART No. DESCRIPTION SYMBOL


1 GEA23550D10 Board, Remote Station, RS5 C7RS
GAA605J4 Used with 70 or 90 A IGBT Drive
2 GAA605J5 Device, Anti-Pollution Used with 120 A IGBT Drive APD
GAA605J6 Used with 210 A IGBT Drive
3 GAA657A4 Filter, Single Phase SPF
4 ACA26800HJ1 Position Indicator CNPI
5 AAA613CZ9 Relay, 120 V AC, 4 Form C VTR
6 618AE2 Socket VTR
AAA605AA30 Suppressor, MOV (mounted on brake coil), Used 110 V Brake ---
7
AAA605AA43 Suppressor, MOV (mounted on brake coil), Used 230 V Brake ---
8 AAA177EM4 Switch, Toggle, Momentary CCTL
Switch, Toggle DDO,
9 AAA177EM5
CHCS

Unpublished Work—Otis Elevator Co., 2016 February 17, 2016 Page 39