No.
Nama Poles Rating Current Frequency &Delay Circuit
EXAMPLE GR1-420-14-B-S1-
GR1 420 14 B
0-1-22-2
1 GR1-420-14-B-S1-0-1-22-2 1 2 DC Medium Series Trip
2 GR1-440-14-B-S1-0-1-22-2 1 4 DC Medium Series Trip
3 GR1-460-14-B-S1-0-1-22-2 1 6 DC Medium Series Trip
4 GR1-420-24-B-S1-1-DA-2 1 2 50/60Hz Medium Series Trip
5 GR1-440-24-B-S1-1-DA-2 1 4 50/60Hz Medium Series Trip
6 GR1-460-24-B-S1-1-DA-2 1 6 50/60Hz Medium Series Trip
7 GR1-610-14-B-S1-0-1-22-2 1 10 DC Medium Series Trip
8 GR1-610-24-B-S1-1-DA-2 1 10 50/60Hz Medium Series Trip
9 GR1-420-24-B-S1-0-1-D2-2 1 2 50/60Hz Medium Series Trip
10 GR1-440-24-B-S1-0-1-D2-2 1 4 50/60Hz Medium Series Trip
11 GR1-460-24-B-S1-0-1-D2-2 1 6 50/60Hz Medium Series Trip
12 GR1-460-26-B-S1-1-1-D2-2 1 6 50/60Hz Long Series Trip
13 GR1-460-24-B-S1-1-1-D2-2 1 6 50/60Hz Medium Series Trip
14 GR1-460-26-B-S1-1-DA-2 1 6 50/60Hz Long Series Trip
15 GR2-616-14-B-S1-0-1-22-2 2 16 DC Medium Series Trip
16 GR2-612-14-B-S1-1-2A-2 2 12 DC Medium Series Trip
17 GR3-660-26-B-S1-0-1-D2-2 3 60 50/60Hz Long Series Trip
18 GR3-660-24-B-S1-1-DA-2 3 60 50/60Hz Medium Series Trip
19 GR1-440-14-B-S1-0-1-22-2 1 4 DC Medium Series Trip
20 GR1-460-24-B-S1-2A-2 1 6 50/60Hz Medium Series Trip
21 GR1-460-24-B-S1-2A-2 1 6 50/60Hz Medium Series Trip
22 GR1-440-24-B-S1-2A-2 1 4 50/60Hz Medium Series Trip
23 GR1-420-24-B-S1-2A-2 1 3 50/60Hz Medium Series Trip
Ket:
di kontrak, penulisannya adalah
GR11-460-24-B-S1-2A-2
sepertinya salah ketik dari GR1 menjadi GR11, karena GR menunjukan jumlah
Actuator Auxiliary Switch Terminal Application Rating
S1 0 1 2
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 110 VDC
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 110 VDC
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 110 VDC
Mid Trip Handle, one per pole S.P.D.T Screw Terminal Screw Terminal 240 VAC
Mid Trip Handle, one per pole S.P.D.T Screw Terminal Screw Terminal 240 VAC
Mid Trip Handle, one per pole S.P.D.T Screw Terminal Screw Terminal 240 VAC
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 110 VDC
Mid Trip Handle, one per pole S.P.D.T Screw Terminal Screw Terminal 240 VAC
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 240 VAC
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 240 VAC
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 240 VAC
Mid Trip Handle, one per pole S.P.D.T Screw Terminal Screw Terminal 240 VAC
Mid Trip Handle, one per pole S.P.D.T Screw Terminal Screw Terminal 240 VAC
Mid Trip Handle, one per pole S.P.D.T Screw Terminal Screw Terminal 240 VAC
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 110 VDC
Mid Trip Handle, one per pole S.P.D.T Screw Terminal Screw Terminal 110 VDC
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 240 VAC
Mid Trip Handle, one per pole S.P.D.T Screw Terminal Screw Terminal 240 VAC
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 110 VDC
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 110 VDC
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 110 VDC
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 110 VDC
Mid Trip Handle, one per pole Without Auxiliary Screw Terminal 110 VDC
karena GR menunjukan jumlah poles
Terminal Polarity Agency Approval
2 2
Line Terminal (+ Connected with top Terminal) TUV Certified
Line Terminal (+ Connected with top Terminal) TUV Certified
Line Terminal (+ Connected with top Terminal) TUV Certified
Non-polarity Sensitive TUV Certified
Non-polarity Sensitive TUV Certified
Non-polarity Sensitive TUV Certified
Line Terminal (+ Connected with top Terminal) TUV Certified
Non-polarity Sensitive TUV Certified
Line Terminal (+ Connected with top Terminal) TUV Certified
Line Terminal (+ Connected with top Terminal) TUV Certified
Line Terminal (+ Connected with top Terminal) TUV Certified
Line Terminal (+ Connected with top Terminal) TUV Certified
Line Terminal (+ Connected with top Terminal) TUV Certified
Non-polarity Sensitive TUV Certified
Line Terminal (+ Connected with top Terminal) TUV Certified
Non-polarity Sensitive TUV Certified
Line Terminal (+ Connected with top Terminal) TUV Certified
Non-polarity Sensitive TUV Certified
Line Terminal (+ Connected with top Terminal) TUV Certified
Non-polarity Sensitive TUV Certified
Non-polarity Sensitive TUV Certified
Non-polarity Sensitive TUV Certified
Non-polarity Sensitive TUV Certified
Line Terminal is on the top
Internal terminal
Screw terminal