Change the setting according to error to resolve Err13, Err15, Err18, Err19, Err20
Sol:
Parameters:
B1.00-- 01
C0.00-- 01
C0.01-- 03
C0.15-- 02
B2.00-- 05
B2.01-- 03
3 wire control
Application FAQ
Q.2 How to Configuration of virtual I/O terminal?
Sol:
For example: DI1 for run, DI2 is for Multi-speed, master
frequency command source is keypad potentiometer,
auxiliary frequency command source is Multi-reference.
Parameters setting:
b0.01=1 (-) (+) PB
AC R U
b0.03=4 Input S
T
V
W
M
b1.00=1
c0.00=1 +24V
PLC
c0.01=20
Run DI1
c4.01=13 Multi-speed DI2 Drive
c4.08=23 DI3
DI4
c4.13=10 DI5
R1A
R1B
f1.00=Multi-speed 0 DI6
R1C
DI7/HI
f1.01=Multi-speed 1 COM
Application FAQ
Q.3 How to configure Auto/Manual operations?
Sol:
B0.01 2 AI1
B0.03 8 AI2
B1.00 1 Terminal ctrl
C0.00 01 Run forward (FWD)
C0.01 20 Frequency cmd. Pattern shift
Application FAQ
Q.4 Washing machine auto/manual operations?
Application Description: If the system is in auto mode then after run cmd. the motor will run forward
for 5 sec (include hold) at 5hz, then it will stop and hold for 5 sec and again will run in reverse direction
and same pattern will follow until the user stops the operation. In Manual mode once the user run for
first time the motor will run in forward direction and then stops and if gives the run command again
then it will run in reverse direction and stops as per set time.
Sol:
B0.01 0
B0.02 Manual Frequency
B0.03 5
B1.00 1
B2.00 Acc. time
B2.01 Dec. time
C0.00 1 (Fwd.)
C0.01 2 (Rev.)
C0.02 41 (Reserved)
Continue..
Application FAQ
Q.4 Washing machine auto/manual operations?
C0.03 20
Solution:
C0.13 00100
C0.15 2
C4.00 41
C4.03 42
C4.04 3
C4.05 10000
C4.06 10000
C4.07 33
F1.00 +10.0% (set as per reqd.)
F1.01 0.0%
F1.02 -10.0% (set as per reqd.)
F1.03 0.0%
F1.17 10012
F1.18 10.0 (set as per reqd.)
F1.19 5.0 (set as per reqd.)
F1.20 10.0 (set as per reqd.)
F1.21 5.0 (set as per reqd.)
F3.08 1
F3.09 1
F3.10 10 (Set as per reqd.)
Application FAQ
Q.5 How to Configuration of C2 group parameters?
Sol:
Sol:
Comparator input source selection of digital
comparator 1,consistent with C1.00 parameters, please
refer the right figure shows.
For example:use R1 output the DI1 function.
Parameters setting:
C1.02=29 Valid
F3.00=22
Input
Valid
Output
T
Application FAQ
Q.7 How to use analog comparator?
Sol: Analog Input
Logic:When analog comparator source selection input signal is bigger
than analog comparator higher value, related terminal outputs ON 80% Higher value
signal, when analog comparator source selection input signal is lower
than analog comparator lower value, related terminal outputs OFF
signal, please refer to right figure.
20% Lower value
For example:use R1 output the analog comparator 1 function,when
running hz up to 50hz,output valid,when running hz below 30hz,output
T
invalid.
Output
Parameters setting: Valid
C1.02=31
F3.02=7
F3.03=100% T
F3.04=60%
Application FAQ
Q.8 How to use timer delay mode?
Trigger
Sol: signal
Logic:In delay mode, when trigger source signal of timer is
valid, timer starts and when the timer’s time is not greater
than timer’s delay time, related terminal outputs OFF signal.
When the timer’s time is lesser than timer’s delay time, T
Output
related terminal output is ON signal, please refer the figure.
For example: use R1 output the timer1 function, when drive
running, need wait 20s output the run signal.
Parameters setting:
T
C1.02=33 Delay time
F3.09=1
F3.10=20
Application FAQ
Q.9 How to use timer high and lower electrical level alternating mode?
Sol:
Trigger
Logic: In high and low electrical level alternating mode, signal
when trigger source signal of timer is valid, and when timer
outputs alternating high and low electrical level, related
terminal outputs ON and OFF signal as per high electrical
and lower electrical level time set by function code. T
Output
For example: use R1 output the timer1 function, when drive
running, need output run signal 5s,and stop output run
signal 5s,keep cycle .
Parameters setting: T
C1.02=33 High electrical level Low electrical level
time time
F3.09=2
F3.11=5
F3.12=5
Gearless PMSM– Elevator
Silent features
Power on Led
PEOFIBUS OK Led
PROFIBUS ERROR Led
MODBUS OK Led
MODBUS ERROR Led
RS485 plug
DP plug
Power
PROFIBUS Module Introduction
01
PROFIBUS Module Introduction
01
more….
Links
01
https://itapp.cgglobal.com/Econnect/
THANK YOU !
www.emotron.com