ISM-1 Integrated System Monitor
ISM-1 Integrated System Monitor
Event
Recorders
Recorders
• Versatile
• High MTBF
4.2
Event Capture Unit Communications Field Contact Voltage
The Event Capture Unit or ECU is the Interface Unit Power Supply
heart of the ISM-1 System. Each ECU The Communications Interface Unit The Field Contact Voltage (FCV) power
supplies the logic required to monitor (CIU) interfaces with single or multiple supply provides wetting voltage for dry
either 128 or 256 inputs and can ECUs as well as CIUs to provide a contact inputs and performs input
function as a stand alone events more advanced recording system. check and ground detection functions.
recorder. Each input is sampled every Each CIU constantly runs a self
millisecond and can be configured for
normally open or normally closed
diagnostic routine and provides error FCV Specifications
messages with clear visual indication of Inputs: 256 or 512 contact inputs per
contacts. system status. supply
The design of the ECU virtually
eliminates the nuisance of false alarms. Wetting Voltage: 24, 48, 125, or
Digital filters are available on a system 250 VDC.
wide and per input channel basis. The
ECU can be configured to automati-
cally delete noisy points from scan and
reinsert them at a later time. Each CIU performs the following
general functions:
• Communicates with, and time sorts
data from, multiple ECUs in the
system
Configurations Available:
• Acts as a smart interface to a variety (1) Single 256 point supply
of Inputs/Outputs. (2) Dual 512 point supply
ECU Specifications – 4 User programmable function (3) Redundant 256 point supply
Inputs: 32-256 contacts per ECU contact inputs (4) Two different FCV voltages, 256
N.O./N.C. per input – 2 User programmable relay points each
outputs
Power: Redundant 20-60 or 90-260
VDC and/or 120/240 VAC 50/60Hz • Selection of up to 14 of the following:
– SCM fiber optic module for
Outputs: (2) RS-232 ports for local interfacing with remote ECU up
terminal I/O and printer, (1) Fiber Optic to 500 meters away (up to 1000
port for interface to CIU. Specify meters optional)
distances up to 1000 meters between – RDM relay driver module provides
ECU and CIU. four additional software driven
relay outputs
MTBF: 115 years – Dual RS-232 module provides
redundant and/or primary and
Legends: 119 characters per input; backup output ports for termi-
divisible in any combination of alarm nals, printers, and other RS-232
and return-to-normal descriptor compatible devices including
Modbus and other DCS
Event Memory: Minimum of 1000 protocols
events per ECU in system. – Parallel Output Port provides
interface for high speed parallel
printers
ISM-SX – Fiber Optic Port provides a high
By addition of Input Isolation Modules, speed data output for interfacing
FCV power supply, and user input/ with other CIUs in very large
output devices, a complete recording systems
system is created for up to 256 points. – IBM Interface provides an error
This is available as the ISM-SX. corrected binary interface for
high speed, reliable remote or
local communication to an IBM
or compatible PC
4.3
AMETEK
Event
Recorders
Recorders
A wide selection of Input Assemblies to meet any application
Input Options
Compact, simple and advanced to save Height Width Depth Maximum Terminations
installation/retrofit costs. These simple Behind Panel Number
termination options offer the widest (Not Including Of Inputs
alternatives and simplify installation to save Wiring)
time and costs. The standard input module,
used in all of these options, includes optical Input Terminal 7.0" 19.0" 22.0" 128 compression
isolators, initial input conditioning and input Shelf (ITS) terminal blocks
check circuitry.
High Density 27.75" 19.0” 8.4" 512 compression
Input Card terminal blocks
Rack or interface to
existing RiS
AN-4100/RA-3800
Input Panels
(AN-4190)
DC Input 19.25" 19.0" 0.0" 64 compression
Terminal terminal blocks
Panel (ITP-C)
DC Input 19.25" 19.0" 0.0" 32 uses GE or States
Terminal terminal blocks
Panel (ITP-TB)
Fully Isolated 24.46” 19” 0.0” 32 2 terminals
ITP per input,
AC/DC uses GE or
States blocks
FIBER OPTIC
FIELD INPUTS
(32-256 INPUTS) FIELD INPUTS
(32-3328 INPUTS)
OUTPUT DEVICES
Large Distributed
ISM-1 System
(Up to 6656 points) MASTER FIBER OPTIC
CIU
SUB- SUB-
CIU CIU
FCV
(PER ECU) ECU ECU ECU ECU
INPUT MODULES
(8 PER ECU) UP TO 13
4.4
ISMCOMM Software ISM System Clock Accuracy: 100 milliseconds per
day typical with software correction,
Specifications 100 milliseconds per day with TCXO
• Automatic Retrieval of Data Inputs: 1 — 6656 inputs option over entire temperature range; ±
1 millisecond with IRIG-B (CIU only).
• “Multi-Site Analyzer’’ Input Resolution: 1 millisecond
system wide, regardless of number of Logic Power: 20-60 or 90-260 VDC
The ISMCOMM software is a inputs and 120/240 VAC 50/60 HZ 10 watts
program used to automatically or maximum per ECU or CIU.
manually retrieve data recorded by Isolation: Via optical couplers to
the ISM-1 to a computer via an RS- provide isolation from input to output Operating Temperature Range:
232 link and selected modems. and power. An optional isolated 32° to 140°F (0 to 60°C)
module provides isolation from input-
Once the data is stored at the com- to-input and accepts AC inputs. Humidity: 0 to 95% non-condensing
puter, files can be merged, a time
window can be extracted, selected Input Normal State: Normally open Surge Withstand Capacity (SWC):
points can be extracted and any (NO) or normally closed (NC) can be set Conforms to IEEE/ANSI C37.90.1-
information can be printed out in true on a per point or group basis via 1989
sequential order. Even data from printer/keyboard or remote computer.
different recorders! RFI: Tested per SAMA standards to
Field Contact Voltage (FCV): PMC 33.1c-1978 class 2, band A, B
Requirements: IBM-PC/XT or Wet or dry contacts 24, 48, 125, and C
compatible with 640K RAM, DOS 3.1 250 VDC, Ametek or customer
or later, monitor, hard disk drive, printer supplied, or 24, 48, 120, 240 VAC Dielectric Strength: Conforms to
and serial port. customer supplied. Negative FVC is IEEE C37.90-1978, 1500 VDC input to
also available. ground
CIU Time Synchronization: IRIG-B, Output Format: ASCII serial text in the
AC-line, pulse per unit time selectable following order: point status, point
by the user, with crystal clock backup. number, date and time, legend
CRT Annunciator:
Typical Computer Screen for ISMCOMM A CRT color annunciator option
provides control room operators with
dynamic alarm displays as they
Event File: C:\RIS\ISM-1\DATA.EVT Total Events = 27 happen. The display can be pro-
Event Type Point Time Date Station grammed for alarm grouping, color
coding, and several types of se-
18 A - 00005 at 16:34:04.348 on 07/31/91 from Northside Station quences. A custom control keyboard
Loss of Station Service provides direct access to current
19 A - 00001 at 16:34:05.771 on 07/31/91 from Northside Station alarms and recent status changes.
Loss of DC/Breaker Control
Modbus:
20 A - 00002 at 16:34:05.794 on 07/31/91 from Northside Station Using a dual serial port, the ISM can
Hot Oil output all recorded data on request to
21 A - 00004 at 16:34:07.662 on 07/31/91 from Northside Station a Modbus master. This is also used to
Hot Spot interface the ISM-1 to our RiSCue
22 A - 00003 at 16:34:07.890 on 07/31/91 from Northside Station Alarm Management Software.
LTC Backup Alarm
23 N - 00002 at 16:34:08.312 on 07/31/91 from Northside Station
Oil Temp. OK
24 N - 00001 at 16:34:08.337 on 07/31/91 from Northside Station
DC on Line
25 N - 00005 at 16:34:09.607 on 07/31/91 from Northside Station
Service OK
26 N - 00004 at 16:34:09.926 on 07/31/91 from Northside Station
Hot Spot OK
27 N - 00003 at 16:34:10.921 on 07/31/91 from Northside Station
LTC Normal
4.5
AMETEK
Event
Recorders
Recorders
ECU Dimension &
Connections
J5 J6 J7 J8 J9
1.718"
(43.64mm) J20
J13 J14
J1 J2 J3 J4
0.856"
(21.82mm)
REAR VIEW
(ROTATED 180° FOR CLARITY)
22.00"
(558.8mm)
11.75"
(298.45mm)
1.87"
(47.50mm)
FRONT VIEW
1.718" 1.25"
(43.64mm) (31.75mm)
18.34"
(465.84mm)
19.00"
(482.60mm)
4.6
CIU Dimensions &
Connections
3.234" FRONT/REAR
(82.14mm) SLIDE MOUNTING
DIMENSIONS ARE
THE SAME
2.014"
(51.16mm)
J15 J0
1.454" J20
(36.93mm) J14 J13 J12 J11 J10 J9 J8 J7 J6 J5 J4 J3 J2 J1
22.00"
(558.8mm)
15.05"
(382.52mm)
1.87"
(47.50mm)
FRONT VIEW
3.47" 3.00"
(88.08mm) (76.20mm)
18.34"
(465.84mm)
19.00"
(482.60mm)
4.7
AMETEK
Event
Recorders
Recorders
FCV Dimensions &
Connections
REAR VIEW
(ROTATED 180° FOR CLARITY)
22.00"
(558.8mm)
15.05"
(382.52mm)
1.87"
(47.50mm)
FRONT VIEW
OFF OFF
18.34"
(465.84mm)
19.00"
(482.60mm)
4.8
Input Module Dimensions
17.00 (431.8) .50
(12.7)
.50
OUTPUT (12.7)
CONN.
POWER 8.36
CONN. (212.34)
18.25
(412.7)
5.25 27.82
(133.4) (701.55)
INPUT
TERM. 11.00
BLOCKS 20.97 (279.4)
(532.64)
7.50
(190.5)
5.25
INPUT
(133.5)
TERM.
BLOCKS
5.25
(133.4)
1.48 (37.6)
.125 1.48
(3.18) (37.59)
TYP.
3.48
(88.39) .42 TYP
(10.67)
DISCRETE WIRE GUIDES 19.00 (482.6)
FOR INPUT TERM. BLOCKS
RIBBON CABLE GUIDES DIMENSIONS: IN
FOR INPUT TERM BLOCKS (MM) DIMENSIONS: IN
.42 18.16 (461.26) (MM)
(10.67)
18.25"
0.0
0.374
(9.50)
18.625
(473.07
19.0
(482.6)
6.969"
(SIDE VIEW)
6.969"
0.86
Input Terminal Shelf (21.84)
0.0
SIDE VIEW
4.9
AMETEK
Event
Recorders
Recorders
ISM-1 Integrated System
Monitor Ordering
ISM –1 1 — 2 — 3 — 4 — 5 — 6 — 7 — 8 — 9 — 10
4.10
ISM-SX Stand Alone
ECU System Ordering
ISM –SX 1 — 2— 3 — 4 — 5 — 6
4.11