ENERGY AUDIT CONDITIONAL GRANT RMK-12 FOR

INDUSTRIAL AND COMMERCIAL SECTOR


(GENERAL INFORMATION)
01
OVERVIEW OF SEDA
02
INTRODUCTION
03
ELIGIBILITY
04
TERMS AND CONDITIONS
TABLE OF 05
BENEFITS
CONTENT
06
APPLICATION PROCESS
07
CASE STUDY
08
ACHIEVEMENTS EACG RMK-11
09
WAY FORWARD
01 To advise the Minister & Government Entities on all
matters relating to sustainable energy

02 To promote & implement national policy objectives


Overview for renewable energy
of SEDA
03 To promote, stimulate, facilitate and develop
sustainable energy
SEDA was 04 To implement, manage, monitor & review the Feed-
established on 1st in Tariff (FiT) system
September 2011
05 To implement sustainable energy laws and recommend
under the SEDA reforms to such laws to the Federal Government
Act 2011 [Act 726]
with some of the 06 To promote private sector investment in sustainable
energy sector
following functions:
07 To act as focal point on matters relating to sustainable
energy & climate change matters relating to energy
TEAM STRUCTURE
Members of Authority

Chief Executive Officer

Special Unit Legal Unit

Integrity Unit Internal Audit Unit

Strategic Planning and Operation and Technical


Corporate Services
Communications Services
Department
Department Department
Chief Strategic Officer
Market Operations Division Finance Division
Strategic Planning Division
Technical Development and Human Resource and
Strategic Communications Facilitation Division Administration Division
Division
Digital Services Division
The Energy Audit Conditional
Grant (EACG) is an energy
efficiency programme under the
12th Malaysia Plan (RMK-12) • Grant will be given to the building owner
for the implementation year of
2021-2025. • Building owner must appoint Energy
Service Companies (ESCO) to carry out
energy audit activities
Grant
Industrial : up to RM 100,000 • Building owner will use the grant for energy
Commercial : up to RM 60,000 audit purposes
INTRODUCTION
Approval Applicant Auditor

Executing
ESCO
Ministry Building
Coordinator or Energy Service Company
Installation Owner Must be registered with
Implementing ST (Peninsular & Sabah)
Agency EIU (Sarawak)
ELECTRICITY NOT A PREVIOUS
USAGE EACG APPLICANT
ELIGIBILITY Open to any commercial AGREED TO
and industrial Not eligible for any
installation with installation which has APPOINT PERSON
minimum monthly received a grant from IN CHARGE
consumption the previous Energy
100,000 kWh/month Audit Conditional Grant
ENERGY AUDIT PHASE IMPLEMENTATION PHASE
(2 months) (3 years)

Must appoint Reporting:


REEM or PIC - Every 3 months to SEDA
- Every 6 months to EMIS

TERMS AND
CONDITIONS
Implementation > Grant
Energy
Audit
= 2 months Cost Applied

Target savings (%) are based


REEM : Registered Electrical Energy Manager on Energy Audit Report
EMIS : Energy Management Information System
Identify Potential
Financial Assistance Energy Savings
(Grant) FREE Facilitation
BENEFITS

FREE Training FREE Awareness


FREE Recognition
ENERGY MANAGEMENT & ENERGY AUDIT TRAINING

BENEFITS
RECOGNITION - GreenPASS Certification
Chaired by Chaired by Return in
SEDA NRECC 1 month

WHOLE
PROCESS Evaluation Technical Steering Offer Contract
20% Grant
Committee Committee Committee Letter Agreement
(1/2)

Invoice or Surat
Chaired by Return in Permohonan
ST 7 days Penyaluran Geran
ESCO
OWNER
SEDA

ESM Implementation
WHOLE
PROCESS Energy Monitoring Monitoring Monitoring Contract
80% Grant
Audit Report 1st Year 2nd Year 3rd Year Ended
(2/2)
ESCO appointment
ended here

Invoice or Surat
Permohonan 1. Investment > Grant
Penyaluran Geran 2. Achieved % savings
CASE STUDY (Industrial Sector)

Installation Review
Installation Name Factory A

Building Location Northern Region

Nature of Business Plastic Manufacturer

Electricity Tariff Category E2

Annual Electricity
Consumption (kWh) 2021 5,451,816.00 kWh
CASE STUDY Load Apportioning
Air-Cond/Process
Cooling
18% Lighting
1%
Fan & Blower
10%

Production Compressed Air


67% 4%
CASE STUDY Proposed ESM from Energy Audit Findings
System Overall
Energy Savings Cost Savings CO2 Savings
Energy Saving Measurement (ESM) Savings Savings
(kWh) (RM) (ton/year)
(%) (%)
No Cost Measures

ESM 1 – Adjust the VFD frequency setting to 45Hz for dust


66,689.56 23,674.79 12.48 % 1.22 % 42.61
collector P5 & P6 blower fan

Low & Medium Cost Measures

ESM 2 – Awareness Training 16,500.00 5,857.50 - 0.30 % 10.54

ESM 3 – Leak test and repair leak for compressed air system 12,498.90 4,437.11 5.09 % 0.23 % 7.99

ESM 4 – Install new VFD to reduce speed for dust collector P3 40,789,84 14,480.39 7.63 % 0.75 % 26.06

ESM 5 – Replace existing AHU motor with higher 16,027.92 5,689.91 1.63 % 0.29 % 10.24

High Cost Measures


ESM 6 – Separate the chilled water system loop for
231,876.00 82,315.98 23.63 % 4.25 % 148.17
production and air-conditioning system

TOTAL 384,382.21 kWh RM 136,455.69 - 7.05 % 245.62


CASE STUDY Implemented ESM
Investment Baseline Current Annual Annual
Energy Saving Measurement (ESM) Cost Consumption Consumption Cost Savings System Savings
(RM) (kWh) (kWh) (RM) (%)

No Cost Measures

ESM 1.1 – Adjust the VFD frequency setting to 45Hz for


dust collector P5 blower fan
0 18.45 14.04 RM 18,092.34 23.9 %
ESM 1.2 - Adjust the VFD frequency setting to 45Hz for
dust collector P6 blower fan
0 25.54 15.37 RM 41,723.15 39.8 %

Medium Cost Measures

ESM 4 - Install new VFD to reduce speed for dust


collector P3
5,000.00 16.60 14.71 RM 7,753.86 11.4 %

TOTAL RM 5,000.00 - - RM 67,569.35 -


CASE STUDY (Commercial Sector)

Building Review
Building Name Hotel A

Building Location Sarawak

Nature of Business Hotel

Net floor area (𝐦𝟐 ) 27,064 m2

Annual Electricity
Consumption (kWh) 2017 5,976,718.00 kWh

BEI Baseline (2017) 220.84


CASE STUDY Building Load

Equipment Chiller Plant


37% (Water Side)
41%

Lift & Escalator


1%
Lighting AHU & FCU
8% AC Split Unit (Air Side)
2% 11%
CASE STUDY Proposed ESM from Energy Audit Findings
Energy Saving Measurement (ESM) Energy Savings (kWh) Cost Savings (RM) % Impact CO2 Savings

No Cost Measures

ESM 1 – Motor operation efficiency check for AHU 9,775.00 2,187.55 0.16 % 6.83

ESM 2 – Increase chilled water set point at Chiller 1 33,945.00 7,597.00 0.57 % 23.56

Low & Medium Cost Measures

ESM 3 – Reschedule 3 nos of corridor AHU operating hours & install timer 67,871.00 15,189.49 1.14 % 47.1

ESM 4 - Retrofitting Fluo T8 18W to LED surface mounted 12W 21,304.00 4,767.91 0.36 % 14.78

ESM 5 - Retrofitting PAR38 Halogen 120W to PAR LED 17W 15,833.00 3,879.12 0.26 % 10.99

ESM 6 - Installation of VSD at Chilled Water Pumps (CHWP) 1 32,779.00 7,335.96 0.55 % 22.75

ESM 7 - Establish of Sustainability Energy Management Systems (SEMS) 107,581.00 30,476.91 1.80 % 74.66

High Cost Measures

ESM 8 - Retrofitting pf existing E14 Incandescent 25W to LED 2.3W 36,445.00 8,929.10 0.61 % 25.29

ESM 9 - Retrofitting of existing M16 Halogen 50W to M16 LED 5W 98,952.00 22,145.38 1.66 % 68.67

ESM 10 - Retrofitting of existing chiller 3 to Energy efficient chiller 554,543.00 124,106.73 9.28 % 384.85

TOTAL 979,028.00 kWh RM 226,615.15 16.38 % 679.49


CASE STUDY Implemented ESM
Investment Cost Energy Savings Cost Savings
Energy Saving Measurement (ESM)
(RM) (kWh) (RM)

No Cost Measures

ESM 1 – Motor operation efficiency check for AHU 0 9,775.00 3,568.00

ESM 2 – Increase chilled water set point at Chiller 1 0 47,524.00 17,346.00

Low & Medium Cost Measures Percentage Energy


ESM 3 – Reschedule 3 nos of corridor AHU operating hours
270.00 67,871.00 15,189.49
Savings Reported:
& install timer

ESM 4 - Retrofitting Fluo T8 18W to LED surface mounted


1,976.00 21,304.00 4,767.91
12W
ESM 5 - Retrofitting of existing M16 Halogen 50W to M16
2,984.00 15,833.00 3,879.00
LED 5W

High Cost Measures

ESM 6 - Retrofitting pf existing E14 Incandescent 25W to LED


14,826.00 554,543.00 124,107.00
2.3W
ESM 7 - Retrofitting 208 nos of FL to LED 13,064.00 6,149.00 1,537.00

TOTAL RM 33,119.00 772,998.84 kWh RM 170,393.18


EACG RMK-11
SUCCESSFUL (INDUSTRIAL
STORY SECTOR):
OF EACG RMK-11 (COMMERCIAL SECTOR)
Energy Savings (kWh) Reported
241,132,323 kWh ≈ RM 95,130,000
215,140,922

176,260,012

136,607,374

86,412,291

24,949,972

2017 2018 2019 2020 2021 2022


Energy Savings, kWh *Data as of Dec 2022
EACG RMK-11
SUCCESSFUL (COMMERCIAL
STORY SECTOR):
OF EACG RMK-11 (COMMERCIAL SECTOR)
Energy Savings (kWh) Reported
78,277,375 kWh ≈ RM 105,077,190
74,215,996

59,878,655

33,527,944

17,169,012
5,955,026

2017 2018 2019 2020 2021 2022


Energy Savings, kWh
*Data as of Dec 2022
For 2024…
8 physical seminar/promotions
10 trainings

112 quota for industrial


91 quota for commercial
WAY
FORWARD
RM 18.8 million approved
Website: www.seda.gov.my/eagrant

FOR OR
INQUIRIES Contact us at:
Officer Email Number
Zulkhairee [email protected] 018-9485525

EACG [email protected] 03-88705800


RE & EE Training Modules