M520A RS-232 Procedure
M520A RS-232 Procedure
USA-E99061 -060*
USA
List of Revisions
(TD) 2 2 (RD)
(SD) 3 3 (SD)
(RTS) 4 7 (RTS)
(CTS) 5 8 (CTS)
(DSR) 6 1 (DCD)
(DCD) 8 4 (DTR)
(DTR) 20 6 (DSR)
(SG) 7 5 (SG)
2) Verify and set the Edit Lock B Parameter on the Process Parameter Screen
a. Access page (2/2) the Control Parameter;
i. Press the [TOOL/PARAM] Function Select Key
ii. Press the [MENU] Menu Key
iii. Press the [CONTROL] Menu Key
iv. Press the [>] Page Key
You should see [CONTROL PARAMETER] on the upper left and page (2/2) on the upper right of the NC screen.
3) Verify and set the Edit Lock C Parameters on the Machine Parameter Screen
a. Access the Machine Parameter Screen;
i. Press the [DIAGN IN/OUT] Function Select Key
ii. Press the [PLC-I/F] Menu Key
iii. Press the [1001], [>]cursor two times, [M], then [INPUT]
iv. Press the [TOOL PARAM] Menu Key
You should see [BASE SPEC. PARAM] on the upper left and page (1/10) on the upper right of the NC screen.
* You will need to set this back to the original value when completed.
ii. Press [7], [>] cursor, [0] then [INPUT], Set the #7 to ‘Edit’;
d. Output a range of program (For example programs between 123 through 789)
First Access the DATA OUTPUT screen on the M520A control
On the personal computer, Set-up Procomm to send a file (make sure the Procomm Window is active)
i. Press Ctrl+Alt+4 on the personal computer
ii. Type in a file name such as M520APrograms2 (it should save it as a .txt file)
iii. Click Save
On the M520A, DATA OUTPUT screen;
iv. Press [1], [>] cursor, [123], [>] cursor,[789] then [Input], Output programs number 123 through 789;
2) Input of User Data - Programs, Tool Data, Common Variables and Macro Programs
a. Access the DATA INPUT screen
i. Press the [DIAGN IN/OUT] Function Select Key
ii. Press the [MENU] Menu Key, then [MENU] Menu Key
iii. Press the [INPUT] Menu Key
You should see [DATA INPUT] on the upper left-side of the screen.
b. Verify and change the #40 EDIT LOCK B parameter to its original setting