Bradley Carter Commercial House Plan

Download as pdf or txt
Download as pdf or txt
You are on page 1of 21

Drawing No: Description Issue / Revision Drawing Scales

1 COVER PAGE 1:1

AS 3 PROPOSED WAREHOUSE 2
3
GENERAL NOTES
SITE ANALYSIS 1:100

DOCUMENTATION 2 4 LOT PLAN 1:500


1:596.86

BRADLEY CARTER 9100068514 5 SITE PLAN 1:200


PEAK DESIGN 6 FLOOR PLAN GROUND 1:200
1:100
7 FLOOR PLAN UPPER 1:200
8 EXTERNAL ELEVATIONS 1:200
9 EXTERNAL ELEVATIONS 1:200
10 SECTON WAREHOUSE 1:100
11 SECTION STAGE 2 1:100
1:139.15

PROPOSED WAREHOUSE 12 Finishes 1:118.96


SITE DETAILS 15 3D PERSPECTIVE 1:100
LOT 54 SP 13753 16 street view 1:100
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
17A TILT PANEL 1:5, 1:10
17B TILT PANNEL 1:100, 1:10
19A ROLL A SHUTTER 1:100, 1:50
19B ROLL A SHUTTER 1:2, 1:50
22 SINAGE 3D VIEW
23 INTERNAL STEEL STUD WALL 1:20
25 REFLECTED CEILING PLAN 1:100
27 HOLOCORE DETAIL 1:200

Sheet Index

GSEducationalVersion
SPECIFICATION FOR TOILET SPECIFICATION FOR MOTOR LEGEND
FIRE SERVICES CYCLE STORAGE AREA LOCKERS
CJ CONSTRUCTION JOINT
PARTITION SINGLE STOREY, CLASS 8 BUILDING TYPE C CONSTRUCTION. DP DOWNPIPE
SUPPLY & INSTALL LAMINEX GREENFIRST PATITIONING FRL REQUIREMENTSALL SUPPLY AND INSTALL MAJORPARTITIONS FP FIRE PLACE
SYSTEM IN THE MALE & FEMALE TOILETS AT THE EXTERNAL WALLS WITHIN 3M OF BOUNDARY ARE PROTECTED BY (WWW.MAJORPARTITIONS.COM) STEEL MESH HWS HOT WATER SYSTEM
PROPOSED AUSTRALIA POST MAIL DELIVERY CENTRE AT 90/90/90:150 CONCRETE WALL. JOINTING DOES NOT REQUIRE FIRE STORAGE LOCKERS IN THE MOTOR CYCLE STORAGE AC AIR CONDITIONING
SOUTHERN ROAD ASHMORE. RATING. AREA AT THE PROPOSED AUSTRALIA POST MAIL PS PLUMBING STACK / DUCT
ALL WORKS TO BE IN ACCORDANCE WITH RELEVANT OPENINGS WITHIN 3M OF BOUNDARY ARE PROTECTED BY 90/90/90 DELIVERY CENTRE AT SOUTHERN ROAD ASHMORE. SP STEEL POST
AUSTRALIAN STANDARDS WALLS. INSTALLATION TO BE IN ACCORDANCE WITH T.B.C TO BE CONFIRMED
AS 1859.1 - 2004 (PARTICLEBOARD) 2 REQUIRED EXITS ARE PROVIDED. MANUFACTURERS SPECIFICATIONS. RL RELATIVE LEVEL
AS 1231 - 2000 ( ALUMINIUM EXTRUSIONS) SIZE OF EXIT DOORS AREA 820 WIDE. DOORS TO HAVE LEVER HANDLES. PANELS SHALL BE 10g .135 WIRE SPOT WELDED INTO AHD AUSTRALIAN HEIGHT DATUM
AS 1428 (DISABLED ACCESS) THE FIRE HYDRANT IS WHERE SHOWN ON THE CONTOUR PLAN. NO 50mm x 50mm x 3.2mm WIRE WELDED INTO AN ANGLE CSD CAVITY SLIDING DOOR
DIVISIONAL PANELS ARE 1700mm H x 1500mm W SPACED FURTHER HYDRANTS REQUIRED. FRAME OF 32mm x 32mm x 3MM WELDED AT EVERY OHC OVER HEAD CUPBOARD
AT 900mm CENTRES AND 170mm OFF THE FLOOR. FIXING HOSE REEL REQUIRED TO LOCATION SHOWN. INSTALL IN ACCORDANCE 200mm. ALL PANELS FOR WIRE MESH LOCKERS SHALL FG FIXED GLASS
OF ALUMINIUM CHANNELS TO REAR WALL AND FRONT WITH AS 2441. BE FASTENED TO FLOOR USING 6.5mm x 70mm FSR FLOOR SPACE RATIO
PANELS WITH STAINLESS STEEL SCREWS WITH A 4mm GAP NO SPRINKLERS REQUIRED. CADMIUM BOLTS AND NUTS. LB LOAD BEARING
BETWEEN THE PANEL AND THE ALUMINIUM CHANNEL FOR PORTABLE FIRE EXTINGUISHERS REQUIRED SWING DOORS SHALL BE MADE OF THE SAME NGL NATURAL GROUND LINE
EXPANSION. 5KG CARBON DIOXIDE OR 4.5KG DRY POWDER DENOTES NATURAL MATERIAL METHOD AS PANELS WITH AN ADDED UBO UNDER BENCH OVEN
FRONTAL PANELS ARE 1800mm H x 300mm W. ALUMINIUM SMOKE VENTILATION. 12.5mm ROD FROM CENTRE TO CORNERS. DOORS WO WALL OVEN
CHANNELS TO BE FIXED TO DIVISIONAL PANEL BLADES EMERGENCY LIGHTING REQUIRED TO COMPLY WITH THE BCA PART E 4.5 SHALL BE EQUIPED WITH PADLOCK LUGS, DOORS DW DISHWASHER
AND SUPPORTED BY TWO SINGLE FOOT ASSEMBLIES. & E 4.8 & AS 2293.1 WITH DIRECTION ARROW INDICATORS ILLUMINATED STIKES AND 40MM PAIR OF HINGES.
MW MICROWAVE
NIB PANELS ARE 1800mm x 150mm W. ALUMINIUM CHANELS IF REQUIRED & HAVE NORMAL POWER SUPPLY & FAILURE EMERGENCY POSTS SHALL BE 30mm x 30mm SQUARE TUBULAR
SD SLIDING GLASS DOOR
TO BE FIXED TO THE WALL AND SUPPORTED BY A SINLE ILLUMINATION BATTERY. STEEL WELDED TO A BASE PLATE 50mm x 150mm x
ASW ALUMINIUM SLIDING WINDOW
FOOT ASSEMBLY. ALLOW FOR A 1mm GAP BETWEEN THE 12M SELF CONTAINEDJNON MAINTAINED EMERGENCY LUMINARE, GREEN 6.4mm USING TWO 70mm x 12mm ANCHOR BOLTS.
ADH DOUBLE HUNG WINDOW
NIB PANEL AND THE CHANNEL FOR EXPANSION PURPOSES. LETTERS ON WHITE BACKGROUND. EQUAL TO STANLITE Q1122 3 OFF LOCKER TOPS SHALL BE SAME AS PANELS.
BCA BIULDING CODE OF AUSTRALIA
DOORS ARE 1700mm H x 600 W WITH EDGES CUT SQUARE LUMINATED EXIT SIGN SHELVES SHALL BE 3 x 90mm x 35mm TIMBER SLATS
AS AUSTRALIAN STANDARDS
AS STANDARD AND HINGED TO THE FRONTAL PANELS WITH SELF CONTAINED NON MAINTAINED EXIT LUMINAIRE. GREEN LETTERS ON ANGLE BRACE.
3 CONCEALED GRAVITY HINGES. ON WHITE BACKGROUND. EQUAL TO STANLITE Q1122. FINISH IS BAKED GREY POWDER OVER A PHOSPHATE
ROUNDED HEAD RAILS AND CHANNELS ARE 13mm AND ARE TREATED STEEL.
CONNECTED TO FRONTAL PANELS AND NIBS WITH
SCREWS PROVIDED. SNAP INSERTS ARE TO ENLOSE DOOR
OPENINGS.
FOOT ASSEMBLES ARE HEIGHT ADJUSTABLE FROM 170mm SPECIFICATION FOR MOTOR
TO 195mm AND ARE FIXED TO THE FLOOR WITH SCREWS
PROVIDED. CYCLE STORAGE AREA LOCKERS
SUPPLY AND INSTALL MAJORPARTITIONS
(WWW.MAJORPARTITIONS.COM) STEEL MESH
STORAGE LOCKERS IN THE MOTOR CYCLE STORAGE
AREA AT THE PROPOSED AUSTRALIA POST MAIL
DELIVERY CENTRE AT SOUTHERN ROAD ASHMORE.
INSTALLATION TO BE IN ACCORDANCE WITH
MANUFACTURERS SPECIFICATIONS.
PANELS SHALL BE 10g .135 WIRE SPOT WELDED INTO
50mm x 50mm x 3.2mm WIRE WELDED INTO AN ANGLE
FRAME OF 32mm x 32mm x 3MM WELDED AT EVERY
200mm. ALL PANELS FOR WIRE MESH LOCKERS SHALL
BE FASTENED TO FLOOR USING 6.5mm x 70mm
CADMIUM BOLTS AND NUTS.
SWING DOORS SHALL BE MADE OF THE SAME
MATERIAL METHOD AS PANELS WITH AN ADDED
12.5mm ROD FROM CENTRE TO CORNERS. DOORS
SHALL BE EQUIPED WITH PADLOCK LUGS, DOORS
STIKES AND 40MM PAIR OF HINGES.
POSTS SHALL BE 30mm x 30mm SQUARE TUBULAR
STEEL WELDED TO A BASE PLATE 50mm x 150mm x
6.4mm USING TWO 70mm x 12mm ANCHOR BOLTS.
LOCKER TOPS SHALL BE SAME AS PANELS. Drawing Title:
The builder shall check and verify all
SHELVES SHALL BE 3 x 90mm x 35mm TIMBER SLATS dimensions and verify all errors and omissions to the
Architect. Do not scale the drawings. Drawings shall
AS 3 - GENERAL NOTES
not be used for construction purposes until issued
ON ANGLE BRACE. MR. BRADLEY CARTER DESIGNER
by the Architect for construction.

FINISH IS BAKED GREY POWDER OVER A PHOSPHATE Client Scale: Date: 15/06/2015
GCIT
TREATED STEEL. Project Name
Status: PRELIMINARY Checked By:

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 2
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 2 of 22
Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the AS 3 - SITE ANALYSIS
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued
by the Architect for construction.

Client Scale: Date: 15/06/2015


GCIT Status: PRELIMINARY Checked By:
Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 3
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 3 of 22
LOT 1

E/07

E/08
LOT 3

LOT 2

LOT 4

Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the AS 3 - LOT PLAN
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued LOT Plan
by the Architect for construction.

Client Scale: 1:596.86 Date: 15/06/2015


GCIT Status: PRELIMINARY Checked By:
Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 4
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 4 of 22
62,819
46,831 1,727 5,761 3,500 5,000

10
1
40,620 6,211 2,504 4,984 3,500 5,000
BOUNDARY 57819

RAINWATER TANK
INSTALL ON STAND

3,473
3,773
PLUMB TO STORMWATER &
RE-USE SYSTEM TO D.G. REQ

1
PROPOSED
11
DEVLOPMENT

8,505
16,837

8,865
18,184
ONSITE VERGE
LANDSCAPE LANDSCAPE

NO KERB
30,000

LOT 1

31,000
7,464
E/07

10,407
E/08
A: 1,312.74 m2

7M CONCRETE CROSSOVER
TO LGA REQ

9,687

7,000
DRAINAGE TO ENGINEERS SPEC.

2,955

11,559
NO KERB
NO K
ERB

5,816
NO KERB

5,000
4,477
BOUNDARY 31000
CONCRETE ESCAPE PATH TO S.E DESIGN
NO KERB
BOUNDARY 31000 BOUNDARY 57819
1,000

CONCRETE PAVING
125MM THICK TO S.E DESIGN
DRIVEWAY & CARPARK TO BE INSTALLED
WITH MINIMIUM FALLS TO SUIT
CONTAINER LAYDOWN

40,620 7,938 5,761 3,500 5,000


43,563 2,600 2,600 2,600 2,956 3,500 5,000

N 57,819 5,000

The builder shall check and verify all


Drawing Title:
dimensions and verify all errors and omissions to the AS 3 - SITE PLAN
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued Site Plan
by the Architect for construction.

Client Scale: 1:200 Date: 15/06/2015


GCIT Status: PRELIMINARY Checked By:
Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 5
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 5 of 22
40,620
2,351
36,465 1,634 170

6,875 6,720 6,720 6,720 6,720 6,865

1
1 2 3 4 5 6 7

10
9

1
3 1
23 23

SUMP & SUMP & SUMP & SUMP & SUMP & MDF M.S.S.B
770 HCT

170
150 PVC 150 PVC 150 PVC 150 PVC 150 PVC
RAINWATER TANK
BOX GUTTER OVER DOWN PIPE INSTALL ON STAND

5,997
UNDERSLUNG THROUGH FRONT WALL
870 HCT PLUMB TO STORMWATER &

6,917
RE-USE SYSTEM TO D.G. REQ
20% OF ROOF TO DRAIN STORAGE

9,717
1

982
PRODUCTION AREA

11 A: 26.52 m2 W054

192
W054 W054

SKYLIGHT

SKYLIGHT

SKYLIGHT

SKYLIGHT

SKYLIGHT
TO S.E DESIGN

TO S.E DESIGN

TO S.E DESIGN

TO S.E DESIGN

TO S.E DESIGN
870 HC

RAFTER OVER

RAFTER OVER

RAFTER OVER

RAFTER OVER

RAFTER OVER

956
2,113

1,760
PRODUCTION AREA PRODUCTION AREA

A: 21.19 m2 A: 13.28 m2

2,615
870 SC W054

ROOF 30 SLOPE
W054

2
9

1,706
INTERNAL WALL
75MM STEEL STUD
UP
W054

PRODUCTION AREA

A: 1,143.95 m2
30,000

300 MM RAD 300 MM RAD 300 MM RAD

2,400
WHIRLY BIRD WHIRLY BIRD WHIRLY BIRD
29,660

Fire Cabinet
2
8

ROOF 30 SLOPE

16,883

19,320
SKYLIGHT

SKYLIGHT
SKYLIGHT

SKYLIGHT

SKYLIGHT

SKYLIGHT
TO S.E DESIGN

TO S.E DESIGN

TO S.E DESIGN

TO S.E DESIGN

TO S.E DESIGN
RAFTER OVER

RAFTER OVER

RAFTER OVER

RAFTER OVER

RAFTER OVER

15,953
INDUSTRIAL GRADE

MOTOR OPERATED
ROLLER SHUTTER

P/COAT FINISH

6000 X 6000
N 870 PA

Fire Cabinet
D
FIRE EXIT B
Fire Cabinet

870
170

2,318
WALL TYPE EAVES GUTTER OVER
1
170MM TILT UP
CONCRETE PANELS 17A
1
8
5,730 34,890
170 40,280 170
40,620 Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the AS 3 - FLOOR PLAN GROUND
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued GROUND FLOOR
by the Architect for construction.

Client Scale: 1:200 Date: 15/06/2015


GCIT Status: PRELIMINARY Checked By:
Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 6
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 6 of 22
46,831
227
40,620 1,006 4,303 675
36,404 1,483 2,563 1,176 4,420

40,620 1,006 4,303 902

1
1 2 3 4 5 6 7

10
9

1,880
430

170
WALL
175MM TILT UP
CONCRETE PANNELS

2,703

4,191

1,500
RAIN WATER TANK

1,201 444
INSTALL ON STAND PLIMB TO STORM WATER
INTERNAL WALL
75 MM METAL STUD WALL W052 & RE-USE SYSTEM TO D.G. REQ

W071
OFFICE 2

A: 38.90 m2

3,557
1 BEAM BELOW TO S.E DESIGN
BEAM BELOW TO S.E DESIGN
11 W054

4,369
W052

2,414 6,000

1,850 1,903 957


W054
2 X 870
W072
SC

BEAM BELOW TO S.E DESIGN


900 GLASS
Fire Cabinet
16

956
15
14
13
W055
12

2
9
11 BEAM BELOW TO S.E DESIGN
10
9 1

900
8 2
7 3
6 4

OFFICE 1
W060

VIOD
30,000

30,000
A: 81.65 m2

930
W060

9,645

2,380
2
8

W070

3,457
W060
W060
BEAM BELOW TO S.E DESIGN
W060

942
W060 W060
W060

15,973
10,669
10,579
1
8
900 950
40,620 963 2,550 173
Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the AS 3 - FLOOR PLAN UPPER
37,764 2,686 5,606 90 685 MR. BRADLEY CARTER DESIGNER
Architect. Do not scale the drawings. Drawings shall
not be used for construction purposes until issued
by the Architect for construction.
2ND FLOOR

Client Scale: 1:200 Date: 15/06/2015


GCIT Status: PRELIMINARY Checked By:
Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 7
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 7 of 22
RELOCATED AWNING SIGNAGE FEATURE CLADDING AWNING FEATURE CLADDING WALL TYPE
PFC COLORBOND 4000 X 7700 COLORBOND C/ORB ON PFC TYPE ALUCABOND CLADDING 170MM TILT UP
CLADDING WITH FRC SOFFIT LIGHTWEIGHT STRUCTURE COLORBOND CLADDING ON LIGHTWEIGHT STRUCTURE CONCRETE PANELS
WITH FRC SOFFIT TEXTURE PAINT FINISH

T.O.W
10400

2
19A
CL 2
5822

1ST LV
5822

CL 1
2555

G LV
0

RAINWATER TANK
3 GLAZED WINDOWS GLAZED WINDOWS AND DOORS INSTALL ON STAND
19A GLAZING TO BCA REQ. IN GLAZING TO BCA REQ. IN PLUMB TO STORMWATER &
POWDERCOATED COMMERCIAL ALUMINIUM FRAMES POWDERCOATED COMMERCIAL ALUMINIUM FRAMES RE-USE SYSTEM TO D.G. REQ

ELEVATION 1

AWNING

1 2 3 4 5 6 7
PFC TYPE
COLORBOND CLADDING
WITH FRC SOFFIT

FEATURE CLADDING
COLORBOND C/ORB
WALL TYPE SKYLIGHT ROOF SHEETING ON LIGHTWEIGHT STRUCTURE
170MM TILT UP 2400 GSM ALSYNITE 0.50 MM TCT
CONCRETE PANELS OVER SAFTY MESH LYSAGHT SPANDEK
TEXTURE PAINT FINISH MATERIAL FINISH
SILVER SPRAY COLORBOND
ROOF PITCH 30

T.O.W
10400

CL 2
5822

1ST LV
5822

CL 1
2555

G LV
0

GLAZED WINDOWS AND DOORS FEATURE CLADDING


GLAZING TO BCA REQ. IN ALUCABOND CLADDING ON
POWDERCOATED COMMERCIAL ALUMINIUM FRAMES LIGHTWEIGHT STRUCTURE

ELEVATION 2

Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the AS 3 - EXTERNAL ELEVATIONS
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued ELEVATION 1, ELEVATION 2
by the Architect for construction.

Client Scale: 1:200 Date: 15/06/2015


GCIT Status: PRELIMINARY Checked By:
Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 8
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 8 of 22
BOUNDARY LINE BOUNDARY WALL SIGNAGE BOUNDARY LINE
170MM TILT UP 4000 X 7700
CONCRETE PANELS
TEXTURE PAINT FINISH

T.O.W
10400

CL 2
5822

1ST LV
5822

CL 1
2555

G LV
0

ELEVATION 3

7 6 5 4 3 2 1
ROOF SHEETING SKYLIGHT
0.50 MM TCT 2400 GSM ALSYNITE
FEATURE CLADDING AWNING LYSAGHT SPANDEK OVER SAFTY MESH
ALUCABOND CLADDING PFC TYPE MATERIAL FINISH
ON LIGHTWEIGHT STRUCTURE COLORBOND CLADDING SILVER SPRAY COLORBOND
WITH FRC SOFFIT ROOF PITCH 30

T.O.W
10400

CL 2
5822

1ST LV
5822

CL 1
2555

G LV
0

GLAZED WINDOWS AND DOORS RAINWATER TANK WALL TYPE


GLAZING TO BCA REQ. IN INSTALL ON STAND 170MM TILT UP
POWDERCOATED COMMERCIAL ALUMINIUM FRAMES PLUMB TO STORMWATER & CONCRETE PANELS
RE-USE SYSTEM TO D.G. REQ TEXTURE PAINT FINISH

ELEVATION 4

Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the AS 3 - EXTERNAL ELEVATIONS
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued ELEVATION 3, ELEVATION 4
by the Architect for construction.

Client Scale: 1:200 Date: 15/06/2015


GCIT Status: PRELIMINARY Checked By:
Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 9
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 9 of 22
STUD WALLS ROOF STRUCTURE WALL TYPE ROOF SHEETING FUTURE CRANE BEAM
75MM METAL STUD WALL TO S.E. DESIGN 170MM TILT UP 0.50 MM TCT BY OTHERS
CONCRETE PANELS LYSAGHT SPANDEK 1
TEXTURE PAINT FINISH MATERIAL FINISH 19A
SILVER SPRAY COLORBOND

2
17A T.O.W
10400
683

1,253
CL 2
5822

ROLLER SHUTTER
8,759

INDUSTRIAL GRADE
P/COAT FINISH
MOTOR OPERATED 1ST LV

7,510
6000 X 6000 5822

CL 1
2555

G LV
0
2 1
19B 19B
2
WINDOWS AND DOORS SLAB
17B
COMMERCIAL FRAME ALUMINIUM 125MM CONCRETE SLAB
SUITE, GLAZING, CLEAR GLASS TO BCA REQ. TO S.E. DESIGN FOOTINGS TO ENGINEERS SPEC

Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the AS 3 - SECTON WAREHOUSE
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued WAREHOUSE SECTION
by the Architect for construction.

Client Scale: 1:100 Date: 15/06/2015


GCIT Status: PRELIMINARY Checked By:
Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 10
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 10 of 22
1 2 3 4
DULUX Duraflex™ 2 - PC655

1
Aluminium
Satin Natural Anodized

2
SILVER SPRAY COLORBOND

3
DULUX AcraTex 951

4
Monument® Colorbond

5
DULUX AcraTex 951

6
INTERGRAIN UltraClear Exterior

7
ALUCABOND CLADDING

8
Honed Satin Finish
Granites of Australia

5 6 7 8 9

Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the AS 3 - Finishes
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued Finishes
by the Architect for construction.

Client 1:118.96
Scale: 1:100 Date: 15/06/2015
GCIT Status: PRELIMINARY Checked By:
Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 12
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 12 of 22
EXTERNAL VIEW

RECEPTION

Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the AS 3 - 3D PERSPECTIVE
OFFICE MR. BRADLEY CARTER DESIGNER
Architect. Do not scale the drawings. Drawings shall
not be used for construction purposes until issued
by the Architect for construction.

Client Scale: Date: 9/06/2015

GCIT Status: PRELIMINARY Checked By:


Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 12
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 12 of 22
Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the AS 3 - street view
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued street view

street view
by the Architect for construction.

Client Scale: 1:100 Date: 9/06/2015

1:100 GCIT
Project Name
Status: PRELIMINARY Checked By:

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 15
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 15 of 22
PARAPET WALL
(IF APPLICABLE)

JOIST

0" THRU 4 1/2"(VARIES)

RAKE ANGLE MK.

BEARING PLATE BY OTHERS

PRE CAST WALL

5"
OPTIONAL INTERNAL SEALAND
AND BACKING ROAD

STEEL LINE
OUTSIDE
BUILDING LENTGH
INSIDE
LOAD BEARING PRE CAST/ TILT UP DETAIL
WDNWALL RAKE ANGLE WITH JOISTS (LIGHT LOADING CONDION)

PANNEL TO ROOF
2 1:10

SEALANT AND BACKING


WALL CORNER
ROAD APPLIED EXTERNALLY
ACCORDING TO MANUFACTURES
RECOMMENDATIONS
20

Drawing Title:
The builder shall check and verify all

CORNER WALL dimensions and verify all errors and omissions to the TECNICAL DRAWINGS - TILT PANEL

1
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued CORNER WALL, PANNEL TO ROOF
by the Architect for construction.
1:5 Client Scale: 1:5, 1:10 Date: 9/06/2015

GCIT Status: PRELIMINARY Checked By:


Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 17A
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 17A of 22
EXTERNAL FACE

BOLT THROUTGH SPLICE PLATE INTO


ANCHORED INSERT CAST IN PANEL CAST IN FERRULE WITH
FIRE RATED MATERIAL ANCHORING BAR
GALVANISED SPLICE PLATE GROUT FILLED POCKET
WITH SLOTTED HOLES
REINFORCING BAR SCRWED TO CAST IN
FERRULE AT NOMINATED CENTERS
PRE CAST PANNEL

GROUTED CORE-HOLE
WITH FLOWABLE GROUT
CONSTRUCTION JOINT

CAST-IN FERRULES
AS PER ENGINEERS
DOCUMENTATION

THREADED DOWEL

GROUT
MORTAR STOP WITH FACE SEAL DRY PACK MORTAR IN SITU CONCRETE SLAB

CAST IN DERULE WITH


ANCHORING BAR

FOOTINGS BY ENGINEER

PANEL TO PANEL PANEL TO FLOOR


1 2
Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the TECNICAL DRAWINGS - TILT PANNEL
Architect. Do not scale the drawings. Drawings shall
1:20 1:10 MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued
by the Architect for construction.
PANEL TO PANEL, PANEL TO FLOOR

Client Scale: 1:100,


1:20 1:10 Date: 9/06/2015

GCIT Status: PRELIMINARY Checked By:


Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 17B
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 17B of 22
5 OF RIVET
1/4" (6.35) STEEL/ OR 1 OF RIVET
EQUIVALENT 1/4" (6.35)
STEEL OR EQUIVALENT
DOOR DRUM SUPPORT BRACKETS
INSTALL TO B&D STANDARD
INSTALLATION PROCEDURES
OPENING HEIGHT 10000 MAX

DOOR GUIDES FIXED


TO STRUCTURE

ROLL A SHUTTER
WINDCLIP
P/N RS0055 LH
P/N RS0054 RH

DETAIL SLAT PROFILE


1 1:100

23.14 0/A

OPENING WIDTH 6000


DOOR GUIDES FIXED TO STRUCTURE 116± 0.5
(REFER TO SECTION 1)
CURTIAN SLAT TYPE SECTION
6/100
ELEVATION
3 1:50
CURTIAN PART
2 1:100

Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the TECNICAL DRAWINGS - ROLL A SHUTTER
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued DETAIL SLAT PROFILE, CURTIAN PART, ELEVATION
by the Architect for construction.

Client Scale: 1:100, 1:50 Date: 9/06/2015

GCIT Status: PRELIMINARY Checked By:


Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 19A
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 19A of 22
50 X 25 X 6 STEEL LUG (GRADE 300)
(P/N 015950) PROVIDED AT CENTRES
AS REQUIRED (TABEL 2) DIAMETER 20 PUDDLE WELDS AT 300 CTS

3.2

6MM CWF, 25 MM LONG TO


EACH SIDE OF LUG

40 X 12 FLAT BAR 5
(GRADE 300)

43.5 ± 0.5
IR = 2.4

3.2
112MM MINIMUM

83 ± 1
21MM MINIMUM

CHANNEL GUIDE DETAIL


2 1:50

REINFORCED CONCRETE PANELS TO


BE DESIGNED BY OTHERS CURTIAN (Fx) (kN/m)

M10 GALV. "ANKASCREWS" OR EQUIVALENT


AT CENTERS ASA SPECIFIED IN TABEL 2
(75MM EMBEDMENT)

(fy)(kN/m)
25 MM CURTIAN OVERFLAP
WIND CLIP
Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the TECNICAL DRAWINGS - ROLL A SHUTTER
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued FIXING TO CONCRETE, CHANNEL GUIDE DETAIL
by the Architect for construction.
41 MM
Client Scale: 1:2, 1:50 Date: 9/06/2015

GCIT Status: PRELIMINARY Checked By:


Project Name

FIXING TO CONCRETE PROPOSED WAREHOUSE


1
PEAK DESIGNS Project No: Drawing No.:

AS 4 19B
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united
1:2
GSEducationalVersion
Page: 19B of 22
Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the TECNICAL DRAWINGS - SINAGE 3D VIEW
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued
by the Architect for construction.

Client Scale: Date: 9/06/2015

GCIT Status: PRELIMINARY Checked By:


Project Name

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 15
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 15 of 22
92 124 92

MASONRY ANCHOR

STEEL STUD

BINDEX SEALANT

ACOUSTICS
STEEL STUD Rw (Rw + Ctr)
50mm EARTH WOOL
11kg / M3

50(42)

92
MASONRY ANCHOR

124
BOTTOM TRACK

BLINDEX SEALANT

5-10
5-10

KNAUF PLASTERBOARD
1 LAYER OF 16mm FIRESHIELD
FIRE RATED: -/60/60

CONNECTON TO FLOOR
2 1:20
CONNECTION TO WALL
1 1:20

KNAUF PLASTERBOARD
1 LAYER OF 16mm FIRESHIELD
FIRE RATED: -/60/60

ACOUSTICS
Rw (Rw + Ctr)
50mm EARTH WOOL
11kg / M3

50(42)

TRACK

BUTTON HEAD SCREW


STEEL STUD
124
92

Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the TECNICAL DRAWINGS - INTERNAL STEEL
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued CONNECTION
STUD WALL TO WALL, CONNECTON TO FLOOR, T SECTION
by the Architect for construction.

Client Scale: 1:20 Date: 9/06/2015

GCIT Status: PRELIMINARY Checked By:

T SECTION Project Name

3 1:20
PEAK DESIGNS
united
PROPOSED WAREHOUSE
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
Project No:

AS 4
Drawing No.:

23
GSEducationalVersion
Page: 23 of 22
A
C C

OFFICE 2

A: 38.90 m2
C C

C C

C C

C
C

LIGHT SWITCH

16 2 POWER POINT
15
14
13 C C
12 FLURESENT LIGHT
11
10
9 1 C
SMOKE ALARM /
8 2
C
2 EMERGENCY LIGHT
7 3
6 4
A AIR CONDITIONING
C C

OFFICE 1
A

A: 81.65 m2
5

C
C

C C

Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the TECNICAL DRAWINGS - REFLECTED CEILING
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued reflected ceiling plan
PLAN
by the Architect for construction.

reflected ceiling plan


1 Client Scale: 1:100 Date: 15/06/2015
GCIT
1:100 Project Name
Status: PRELIMINARY Checked By:

PEAK DESIGNS PROPOSED WAREHOUSE Project No: Drawing No.:

AS 4 25
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 25 of 22
1196
DOWEL OR PLATE WELDED TO TOP OF BEAM

102.5

80 AT SUPPORT
5
15
205

280
102.5
10

81

129 187.6 187.6 187.6 187.6 187.6 129


NOTE: STRUCTURAL STEEL BEAM
PROJECT CONSULTANT TO CHECK
SLAB CODE: F205.6 STABILITY OF BEAM OR ERECTION CASE
NOT LESS THAN 50MM BEARING
DESIGN WIDTH 1200 MM
TOP STRANDS: 0-5
BOTTOM STRANDS: 4-7
PRESTRESS: 500-1000MPa
CONCRETE GRADE 50MPa
COVER TO STRAND: 35 MM
FIRE RATING: 11/2 - 3 HOURS
CROSS SECTIONAL AREA: 124.5X103 MM2
BEAM TO HOLO CORE
2
SELF WEIGHT 206 kg/m2
SELF WEIGHT(INCL. SCREED) 426 kg/m2

CROSS SECTION
1

REINFORCMENT IN ACCORDANCE WITH PROJECT REQUIREMENTS

SUPPORT LEDGE WELDED

80 AT SUPPORT
TO PRECAST STAIR FLIGHT

TOOLED JOINT

NO CHAMFER ON PANELS

30 X 3 mm NEOPRENE BEARING STRIP

NOT LESS THAN 50 MM BEARING

SUPPORTING HOLLOW CORE

FILL CORE AT SUPPORT AS REQUIRED


PRECAST STAIR FLIGHT
HOLOCORE TO EXTERIOR WALL
4
Drawing Title:
The builder shall check and verify all
dimensions and verify all errors and omissions to the TECNICAL DRAWINGS - HOLOCORE DETAIL
Architect. Do not scale the drawings. Drawings shall
MR. BRADLEY CARTER DESIGNER not be used for construction purposes until issued CROSS SECTION, BEAM TO HOLO CORE, HOLOCORE STAIR DETAIL,
by the Architect for construction.
HOLOCORE TO EXTERIOR WALL

Client Scale: 1:200 Date: 9/06/2015

GCIT Status: PRELIMINARY Checked By:

HOLOCORE STAIR DETAIL


Project Name
PROPOSED WAREHOUSE
3 PEAK DESIGNS Project No: Drawing No.:

AS 4 27
91 SHIPPER DRIVE COOMERA GOLD COAST QLD AUSTRALIA
united

GSEducationalVersion
Page: 27 of 22

You might also like