DM156 Mammography Series Specs

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Angell Technology

Digital Medical X-ray Radiographic System


FangHua I Series

DM156
Specifications

www.szangell.com E-mail: [email protected]


Configurations

No. Part Name Quantity


1 Flat Panel Detector Standard 1 pcs
2 DXRay Diagnostic Workstation Standard 1 pcs
3 High Frequency Generator Standard 1 pcs
4 X-Ray Tube Standard 1 pcs
5 Compression System Standard 1 pcs
6 C-Arm System Standard 1 pcs

High Frequency Generator

• Power: 5 KW
• Output Voltage: 20-40KV
• Input Voltage: 220V AC , 50/60 Hz
• Range of mAs:10-500mAs
• Range of mA: 10-200mA
• Range of ms: 0.005s-10s

X-Ray Tube

• Target Material: Molybdenum


• Focus: 0.1/0.3mm
• Angle of target: 15°
• Anode Heat Capacity: 300kHU
• Anode Speed: 10,000 RPM
• Nominal Anode Input Power: 4.8KW / 9KW

Flat Panel Detector

• Detector Technology: a-Si Flat Panel Detector


• Scintillator: CsI
• Pixel Size: 77 um
• Pixel matrix: 4096 x 3072
• Field of view: 24 x 30cm (10x12inch)
• Grayscale: 16bits
• Resolution: 6lp/mm
• Communication: Gigabit-Ethernet

Compression System and C Arm System

www.szangell.com E-mail: [email protected]


• Compressor: Automatic Release Function and Manual Control Function
• Size of compressor: 240x310mm (compressor 1)
• Size of compressor: 100x100mm (compressor 2)
• Range of compressor: 280mm
• Pressure: 0-196N, value real time display on the indicator
• FID: 1420mm-2020mm,
• Arm Rotating Angle: -135°-+180°, value real time display on the indicator
• SID: 650mm
• Equipped with two rotating, lifting control switch
• Thickness detection, shows on the indicator

DX Ray Diagnostic Workstation

• CPU: INTEL Dual Core


• RAM: 4G
• Hard Disk: 1T
• HD monitor 24 inches Pixel matrix: 1920*1080 pixels
• 2M Medical grade monitor 24 inches

• Case management
• Case management function: including the management of patient information, exam
information and images.
• Worklist enquiry service following standard DICOM3.0 may inquiry from HIS/PACS and
download case information.
• Image acquisition
• Acquisition system: positive and negative film image capture can be configured;
• Real time automatic window width level adjustment;
• Real time ROI (region of interests) clipping;
• Real time enhancement;
• Displaying patient information, examination information, device information and image
information
• Image processing
• Positive and negative film switchover, image zoom, translation, mirror image, rotation,
magnified display;
• Image enhancement, noise reduction: Scheme and level of image enhancement and noise
reduction
• Image labeling function: including drawing straight line, rectangle, polygon, arrow and text;

www.szangell.com E-mail: [email protected]


• Real time reminding the free space of image disk of the system.
• Image output
• Sending SCU with DICOM: support sending image to any PACS and workstations following
Standard DICOM3.0;
• Receiving SCP server with DICOM: support receiving image following Standard DICOM3.0
from any workstation.

Shenzhen Angell Technology Co., Ltd.


Room 408, Building A, Huahan Innovation Park,
Langshan Road, Nanshan District, Shenzhen 518057, China
Tel: (+86) 755-86966744 Fax: (+86) 755-26859389
Whatsapp / Wechat: 0086 186 8159 0043
E-mail: [email protected]
Web: www.szangell.com

www.szangell.com E-mail: [email protected]

You might also like