0% found this document useful (0 votes)
130 views17 pages

Pressure Transmitter - Data Sheet

The document describes a pressure transmitter model IS-3 that is designed for use in hazardous areas. It has measuring ranges up to 6,000 bar and all wetted parts are stainless steel. It is available with various process connections and can measure a wide range of pressures and temperatures.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
130 views17 pages

Pressure Transmitter - Data Sheet

The document describes a pressure transmitter model IS-3 that is designed for use in hazardous areas. It has measuring ranges up to 6,000 bar and all wetted parts are stainless steel. It is available with various process connections and can measure a wide range of pressures and temperatures.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

Pressure

Pressure transmitter
For applications in hazardous areas
Model IS-3
WIKA data sheet PE 81.58

for further approvals


see page 10

Applications
■ Chemical, petrochemical industry
■ Oil, natural gas
■ Machine building

Special features
■ Measuring ranges from 0 ... 0.1 to 0 ... 6,000 bar [0 ... 3 to
0 ... 15,000 psi]
■ Approved for use in hazardous areas, e.g. ATEX, IECEx,
FM and CSA

Fig. left: With angular connector and flush


process connection
Fig. centre: High-pressure version
Fig. right: With field case

Description

For the highest demands The process connections with flush diaphragm are
The pressure transmitters of the IS-3 series have been particularly suitable for the measurement of viscous and
specifically designed for the highest industrial requirements contaminated media and ensure trouble-free pressure
in hazardous areas and feature the common approvals, such measurement at all times.
as ATEX, IECEx, FM and CSA.
The optional field case of the model IS-3 enables operation
The model IS-3 pressure transmitter is available with in extreme environmental conditions and is resistant to
measuring ranges up to 6,000 bar and is suitable for acids, bases, oils and solvents. Via the field case connection
applications ranging from general machine building to integrated into the case's head, the electrical cabling can be
high-pressure applications. installed quickly and easily.

Design Voltage supply


All wetted parts are manufactured from stainless steel and It is recommended that the intrinsically safe variants of the
are fully welded. Internal sealing elements are completely IS-3 series are powered via a suitable repeater power supply.
avoided, so that the unit can be used with almost all media. An ideal voltage supply is offered by the intrinsically safe
The robust case is also made of stainless steel and provides repeater power supply model IS Barrier, see “Accessories”.
a minimum ingress protection of IP65. IP68 versions are also
available.

WIKA data sheet PE 81.58 ∙ 11/2020 Page 1 of 17


Measuring ranges
Gauge pressure
bar 0 ... 0.1 0 ... 0.16 0 ... 0.25 0 ... 0.4 0 ... 0.6 0 ... 1 0 ... 1.6
0 ... 2.5 0 ... 4 0 ... 6 0 ... 10 0 ... 16 0 ... 25 0 ... 40
0 ... 60 0 ... 100 0 ...160 0 ... 250 0 ... 400 0 ... 600 0 ... 1,000 1)
1,600 1) 2) 2,500 1) 2) 4,000 1) 2) 5,000 1) 2) 6,000 1) 2)
psi 0 ... 3 0 ... 5 0 ... 10 0 ... 15 0 ... 20 0 ... 25 0 ... 30
0 ... 50 0 ... 60 0 ... 100 0 ... 150 0 ... 160 0 ... 200 0 ... 250
0 ... 300 0 ... 400 0 ... 500 0 ... 600 0 ... 750 0 ... 800 0 ... 1,000
0 ... 1,500 0 ... 2,000 0 ... 3,000 0 ... 4,000 0 ... 5,000 0 ... 6,000 0 ... 7,500
0 ... 8,000 0 ... 10,000 1) 0 ... 15,000 1)

1) Only for instruments without flush process connection.


2) Only for instruments with ignition protection type Ex i. Not for instruments with SIL 2.

Absolute pressure
bar 0 ... 0.25 0 ... 0.4 0 ... 0.6 0 ... 1 0 ... 1.6 0 ... 2.5 0 ... 4
0 ... 6 0 ... 10 0 ... 16 0 ... 25
psi 0 ... 5 0 ... 10 0 ... 15 0 ... 30 0 ... 60 0 ... 100 0 ... 160
0 ... 200 0 ... 300

Vacuum and +/- measuring ranges


bar -1 ... 0 -1 ... +0.6 -1 ... +1.5 -1 ... +3 -1 ... +5
-1 ... +9 -1 ... +15 -1 ... +24
psi -15 inHg ... 0 -30 inHg ... 0 -30 inHg ... 15 -30 inHg ... 30 -30 inHg ... 60
-30 inHg ... 100 -30 inHg ... 160 -30 inHg ... 200 -30 inHg ... 300

Other measuring ranges on request.

Overload safety
The overload safety is based on the sensor element used. Depending on the selected process connection and sealing,
restrictions in overload safety can result.
A higher overload safety will result in a higher temperature error.

Measuring ranges ≤ 25 bar [≤ 400 psi]: 3-fold


Measuring ranges 40 ... 600 bar [500 ... 8,000 psi]: 2-fold 1)
Measuring ranges ≥ 1,000 bar [≥ 10,000 psi]: 1.15-fold

1) 1.7-fold overload safety with 1,000 psi, 1,500 psi, 4,000 psi and 6,000 psi

WIKA data sheet PE 81.58 ∙ 11/2020 Page 2 of 17


Output signal Reference conditions (per IEC 61298-1)

Analogue signal Temperature


4 ... 20 mA 15 ... 25 °C [59 ... 77 °F]

Permissible load in Ω Atmospheric pressure


Model IS-3: 860 … 1,060 mbar [86 … 106 kPa/12.5 … 15.4 psig]
≤ (supply voltage - 10 V) / 0.02 A - (cable length in m x 0.14 Ω)
Air humidity
Model IS-3 with field case: 45 ... 75 % r. h. (non-condensing)
≤ (supply voltage - 11 V) / 0.02 A
Mounting position
For the test circuit signal of the IS-3 model with field case a Calibrated in vertical mounting position with process
load of ≤ 15 Ω applies connection facing downwards.

Supply voltage
DC 24 V
Voltage supply

Supply voltage U+
Model IS-3: DC 10 ... 30 V Time response
Model IS-3 with field case: DC 11 ... 30 V
Settling time
Supply and signal circuit for ATEX/IECEx ignition ≤ 2 ms
protection type Ex i (see product label) ≤ 10 ms for medium temperatures below -30 °C [-22 °F]
Voltage: Ui = DC 30 V
Current: Ii = 100 mA
Power: Group I (mines susceptible to firedamp): Pi =
Accuracy specifications
800 mW
Group II (explosive gas atmosphere other than
Accuracy at reference conditions
mines): Pi = 800 mW
Group IIIB (explosive gas atmosphere other Accuracy
than mines): Pi = 800/650 mW
Standard ≤ ±0.5 % of span
Group IIIC (explosive gas atmosphere other
Option ≤ ±0.25 % of span 1)
than mines): Pi = 750/650/550 mW
1) Only for measuring ranges ≥ 0.25 bar [3 psi] and ≤ 1,000 bar [15,000 psi]
Effective internal capacitance (version with non-detachable
cable connection) Including non-linearity, hysteresis, zero offset and end value
Ci ≤ 16.5 nF deviation (corresponds to measured error per IEC 61298-2).
Ci ≤ 16.5 nF + 0.2 nF/m
Non-linearity (IEC 61298-2)
Effective internal inductance (version with non-detachable ≤ ±0.2 % of span BFSL
cable connection)
Li = 0 μH Non-repeatability
Li = 0 μH + 2 μH/m < 0.1 % of span

Supply and signal circuit for CSA and FM (see product Mean temperature coefficient of zero point
label) [0 ... 80 °C / 32 ... 176 °F]
Entity/non-incendive parameters: Measuring range ≤ 0.25 bar: ≤ ±0.4 % of span/10 K
Vmax/Ui = 30 V Measuring range > 0.25 bar: ≤ ±0.2 % of span/10 K
Imax/Ii = 100 mA at ambient temperature ≤ 85 °C [185 °F]
Imax/Ii = 87 mA at ambient temperature > 85 °C [185 °F] Mean temperature coefficient of span
Pmax/Pi = 0.8 W [0 ... 80 °C / 32 ... 176 °F]
Ci = 16.5 nF (flying leads: + 0.2 nF/m) ≤ ±0.2 % of span/10 K
Li = 0 μH (flying leads: + 2 μH/m)
Long-term stability at reference conditions
≤ ±0.2 % of span/year

WIKA data sheet PE 81.58 ∙ 11/2020 Page 3 of 17


Adjustability of zero point and span
Adjustment is made using potentiometers inside the
instrument.
Zero point: ±5 %
Span: ±5 %

For use in hydrogen applications, observe the Technical


information IN 00.40 at www.wika.com regarding long-term
stability.

Process connections

Process connections, standard

Standard Thread size Max. nominal pressure Overload safety


EN 837 G¼B 1,000 bar [14,500 psi] 1,400 bar [20,300 psi]
G½B 1,000 bar [14,500 psi] 1,800 bar [26,100 psi]
G⅜B 1,000 bar [14,500 psi] 1,400 bar [20,300 psi]
DIN EN ISO 1179-2 G¼A 600 bar [8,700 psi] 600 bar [8,700 psi]
(formerly DIN 3852-E)
G½A 600 bar [8,700 psi] 600 bar [8,700 psi]
ANSI/ASME B1.20.1 ¼ NPT 1,000 bar [14,500 psi] 1,500 bar [21,700 psi]
½ NPT 1,000 bar [14,500 psi] 1,500 bar [21,700 psi]
SAE J514 E 7/16-20 UNF BOSS 600 bar [8,700 psi] 600 bar [8,700 psi]
9/16-18 UNF BOSS 600 bar [8,700 psi] 600 bar [8,700 psi]
DIN 16288 M20 x 1.5 1,000 bar [14,500 psi] 1,800 bar [26,100 psi]
ISO 7 R¼ 1,000 bar [14,500 psi] 1,600 bar [23,200 psi]
R⅜ 1,000 bar [14,500 psi] 1,400 bar [20,300 psi]
JIS B7505-76 G¼B 1,000 bar [14,500 psi] 1,000 bar [14,500 psi]
- G ½ B male thread / G ¼ female thread 1,000 bar [14,500 psi] 1,400 bar [20,300 psi]
M20 x 1.5 female thread with sealing cone 1) 6,000 bar 15,000 bar
M16 x 1.5 female thread with sealing cone 1) 6,000 bar 10,000 bar
9/16-18 UNF female thread F250-C 1) 6,000 bar 10,000 bar
G ½ B flush 600 bar [8,700 psi] 600 bar [8,700 psi]
G 1 B flush 1.6 bar [20 psi] 10 bar [145 psi]
G 1 B flush, hygienic 25 bar [350 psi] 50 bar [725 psi]

1) Not available for psi measuring ranges.

Process connections for the optional medium temperatures (see page 6)

Standard Thread size Max. nominal pressure Overload safety


EN 837 G¼B 400 bar [5,800 psi] 800 bar [11,600 psi]
G½B 400 bar [5,800 psi] 800 bar [11,600 psi]
DIN EN ISO 1179-2 G¼A 400 bar [5,800 psi] 600 bar [8,700 psi]
(formerly DIN 3852-E)
ANSI/ASME B1.20.1 ½ NPT 400 bar [5,800 psi] 800 bar [11,600 psi]
ISO 7 R¼ 400 bar [5,800 psi] 800 bar [11,600 psi]
- G ½ B flush 600 bar [8,700 psi] 1) 600 bar [8,700 psi] 1)
G 1 B flush 1.6 bar [20 psi] 10 bar [145 psi]
G 1 B flush, hygienic 25 bar [350 psi] 50 bar [725 psi]

1) Restrictions depending on sealing material, see table “Sealing material restrictions for G ½ B flush process connection“

WIKA data sheet PE 81.58 ∙ 11/2020 Page 4 of 17


Sealings

Process connection Material


Standard Option
EN 837 Copper Stainless steel
DIN EN ISO 1179-2 (formerly DIN 3852-E) NBR 1) FKM/FPM 2)
SAE J514 E NBR 1) FKM/FPM 2)
G ½ B flush NBR 1) 4) FKM/FPM 2) 4), FFKM 2) 4), EPDM 3) 4)
G 1 B flush NBR 1) FKM/FPM 2), EPDM 3)
G 1 B flush, hygienic EPDM 3) -

1) Permissible temperature range: -20 ... +100 °C [-4 ... +212 °F]
2) Permissible temperature range: -15 ... +200 °C [5 ... 392 °F]
3) Permissible temperature range: -40 ... +150 °C [-40 ... +302 °F]
4) See also table “Sealing material restrictions for G ½ B flush process connection” with regard to overload safety.

Except for sealings for process connections per EN 837 the sealings listed under “Standard” are included in the delivery.

Sealing material restrictions for G ½ B flush process connection

Material Overload safety


T = -20 ... +80 °C [-4 ... +176 °F] T = -20 ... +150 °C [-4 ... +302 °F]
NBR 1,200 bar [17,400 psi] N/A
FKM/FPM 1,200 bar [17,400 psi] 600 bar [8,700 psi]
FFKM 1,200 bar [17,400 psi] 1,200 bar [17,400 psi]
EPDM 800 bar [11,600 psi] 400 bar [5,800 psi]

T = Ambient temperature
N/A = Not applicable

Electrical connections

Available connections
see “Dimensions in mm”

For ignition protection type Ex nA


■ Circular connector M16 x 0.75 IEC 61076-2-106
■ Cable outlet IP67 with protective cap
■ Cable outlet IP68 (permanent use in the medium)

For ignition protection type Ex tc


■ Cable outlet IP67 with protective cap
■ Cable outlet IP68 (permanent use in the medium)

For measuring ranges > 1,000 bar


■ Angular connector DIN EN 175301-803 A
■ Circular connector M12 x 1 IEC 61076-2-101 A-COD
■ Cable outlet IP67
■ Field case

Reverse polarity protection


U+ vs. U-

Insulation voltage
DC 500 V

WIKA data sheet PE 81.58 ∙ 11/2020 Page 5 of 17


Specifications
Angular connector Circular connector M12 x 1 Bayonet connector
DIN EN 175301-803 A IEC 61076-2-101 A-COD (4- MIL-DTL-26482 (6-pin)
pin)
Connection
diagram

Assignment (2- U+ = 1 U- = 2 U+ = 1 U- = 3 U+ = A U- = B
wire)
Cable shield - - -
Wire cross-section Max. 1.5 mm² - -
Cable diameter 6 ... 8 mm - -
Ship approval: 10 ... 14 mm

Bayonet connector Circular connector M16 x 0.75 All cable outlets


MIL-DTL-26482 (4-pin) IEC 61076-2-106 (5-pin)
Connection
diagram

Assignment (2- U+ = A U- = B U+ = 3 U- = 1 U+ = brown (BN) U- = green (GN)


wire)
Cable shield - - Grey (GY)
Wire cross-section - - 0.5 mm²
Cable diameter - - 6.8 mm
7.5 mm (variants for permanent use
in the medium)

Cable outlet IP67 with Field case


protective cap
Connection
diagram

Assignment (2- U+ = brown (BN) U- = blue (BU) U+ = 1 U- = 2 Test+ = 3 Test- = 4


wire)
Cable shield Braid 5
Wire cross-section 0.34 mm² Max. 1.5 mm²
Cable diameter 5.5 mm Cable gland
Nickel-plated brass: 7 ... 13 mm
Stainless steel: 8 ... 15 mm
Plastic: 6.5 ... 12 mm

Legend
U+ Positive power supply terminal
U- Negative power supply terminal
S+ Analogue output
Test+ Positive test connection
Test- Negative test connection

WIKA data sheet PE 81.58 ∙ 11/2020 Page 6 of 17


Operating conditions

Ingress protection (per IEC 60529)


The ingress protection depends on the respective electrical connection.
The stated ingress protection only applies when plugged in using mating connectors that have the appropriate ingress protection.
IP65 ■ Angular connector DIN EN 175301-803 A

IP67 ■ Circular connector M12 x 1 IEC 61076-2-101 A-COD


■ Circular connector M16 x 0.75 IEC 61076-2-106
■ Cable outlet IP67
■ Cable outlet IP67 with protective cap (precondition: Avoidance of water accumulation in the protective cap)
■ Bayonet connector MIL-DTL-26482

IP68 ■ Cable outlet IP68 cable gland (72 h / 300 mbar)


■ Cable outlet IP68 (permanent use in the medium, max. pressure 2 bar)

IP69K ■ Field case

Ignition protection types ATEX/IECEx


■ II 1G Ex ia IIA T4/T5/T6 Ga
■ II 1G Ex ia IIC T4/T5/T6 Ga
■ II 1/2G Ex ia IIC T4/T5/T6 Ga/Gb
■ II 3G Ex ic IIC T4/T5/T6 Gc X
■ II 3G Ex nA IIC T4/T5/T6 Gc X
■ II 3D Ex tc IIIC T90 °C Dc X
■ II 1D Ex ia IIIB T200 135 °C Da
■ II 1D Ex ia IIIC T135 °C Da
■ II 1/2D Ex ia IIIC T135 °C Da/Db
■ II 1/2D Ex ia IIIB T200 135 °C Da/Db
■ I M1 Ex ia I Ma

Ignition protection types for other approvals, see “Approvals”

Vibration resistance (per IEC 60068-2-6, vibration under resonance)


■ Model IS-3: 20 g
■ Model IS-3 with field case and cable outlet IP67 with protective cap: 10 g
■ Model IS-3 with measuring range > 1,000 bar: 5 g
■ Model IS-3 for optional medium temperature ranges: 5 g
■ Model IS-3 for optional medium temperature ranges and with field case: 2 g

Shock resistance (per IEC 60068-2-27, mechanical shock)


■ Model IS-3: 1,000 g
■ Model IS-3 with field case: 600 g
■ Model IS-3 with measuring range > 1,000 bar: 100 g
■ Model IS-3 with cable outlet IP67 with protective cap: 100 g
■ Model IS-3 for optional medium temperature ranges: 100 g
■ Model IS-3 for optional medium temperature ranges and with field case: 50 g

Permissible temperature ranges for operation in accordance with the data sheet specifications (for ignition
protection type Ex i)

Available options
Standard -20 ... +80 °C [-4 ... +176 °F]
Option 1 -20 ... +150 °C [-4 ... +302 °F] (only for flush process connections and measuring ranges ≤ 600 bar [8,000 psi])
Option 2 -40 ... +150 °C [-40 ... +302 °F] (only for process connections with pressure port and measuring ranges ≤ 400 bar [5,000 psi])
Option 3 -40 ... +200 °C [-40 ... +392 °F] (only for process connections with pressure port and measuring ranges ≤ 400 bar [5,000 psi])
Oxygen -20 ... +60 °C [-4 ... +140 °F]

WIKA data sheet PE 81.58 ∙ 11/2020 Page 7 of 17


■ Medium/ Permissible temperature ranges depend on the option selected above, the EPL,
ambient: the temperature class and the selected electrical connection.
→ See chapter “Specifications” in the operating instructions.
■ Storage: -20 ... +80 °C [-4 ... +176 °F]

Permissible temperature ranges for operation in accordance with the data sheet specifications (for ignition
protection types Ex nA and Ex tc)
■ Medium: -15 ... +70 °C [5 ... +158 °F] (with oxygen -15 ... +60 °C [5 ... +140 °F])
■ Ambient: -15 ... +70 °C [5 ... +158 °F]
■ Storage: -15 ... +70 °C [5 ... +158 °F]

Materials

Wetted parts
■ Measuring ranges ≤ 25 bar and ≤ 400 psi, process connection G ½ B flush and G 1 B flush: 316Ti
■ Measuring ranges ≥ 40 ... ≤ 1,000 bar and ≥ 500 ... ≤ 15,000 psi: 316Ti and S13800
■ Measuring ranges > 1,000 bar: S13800
■ Process connection G 1 B flush, hygienic: 316L
■ Measuring ranges ≤ 25 bar and ≤ 400 psi with process connection with pressure port for optional medium temperature
range: 316L and 316Ti
■ Measuring ranges > 25 bar and > 400 psi with process connection with pressure port for optional medium temperature
range: 316L, 316Ti and S13800

For sealing materials see “Process connections”


Where the medium is hydrogen, contact the manufacturer.

Non-wetted parts
■ Case: Stainless steel
■ Angular connector DIN EN 175301-803 A: PA6
■ Circular connector M12 x 1 adjustable: PA6, stainless steel
■ Circular connector M12 x 1 not adjustable: Stainless steel
■ Circular connector M16 x 0.75 adjustable: PA6, stainless steel, Zn nickel-plated
■ Circular connector M16 x 0.75 not adjustable: Stainless steel, Zn nickel-plated
■ Bayonet connector adjustable: PA6, stainless steel, Al nickel-plated
■ Cable outlet IP67: PA6, stainless steel, nickel-plated brass
■ Cable outlet IP67 with protective cap: Stainless steel, PA66/6-FR
■ Cable outlet IP68 cable gland: Stainless steel, nickel-plated brass
■ Cable outlet IP68: Stainless steel
■ Field case: Stainless steel, nickel-plated brass / stainless steel
■ Internal pressure transmission medium
- No oxygen version: Synthetic oil
- Oxygen version: Halocarbon oil
- Instruments with measuring range > 25 bar [400 psi]: Dry measuring cell

WIKA data sheet PE 81.58 ∙ 11/2020 Page 8 of 17


Approvals
Logo Description Country
EU declaration of conformity European Union
■ EMC directive, EN 61326 emission (group 1, class B) and immunity (industrial application)
During interference consider an increased measuring deviation of up to 1 %.
■ Pressure equipment directive, PS > 200 bar; module A, pressure accessory
■ RoHS directive
■ ATEX directive
Hazardous areas
- Ex i Zone 0 gas [II 1G Ex ia IIA T4/T5/T6 Ga]
[II 1G Ex ia IIC T4/T5/T6 Ga]
Zone 1 mounting to zone 0 gas [II 1/2G Ex ia IIC T4/T5/T6 Ga/Gb]
Zone 2 gas [II 3G Ex ic IIC T4/T5/T6 Gc X]
Zone 20 dust [II 1D Ex ia IIIB T200 135 °C Da]
[II 1D Ex ia IIIC T135 °C Da]
Zone 21 mounting to zone 20 dust [II 1/2D Ex ia IIIB T200 135 °C Da/Db]
[II 1/2D Ex ia IIIC T135 °C Da/Db]
Mining [I M1 Ex ia I Ma]
- Ex n Zone 2 gas [II 3G Ex nA IIC T4/T5/T6 Gc X]
- Ex t Zone 22 dust [II 3D Ex tc IIIC T90 °C Dc X]

IECEx International
Hazardous areas
- Ex i Zone 0 gas [Ex ia IIA T4/T5/T6 Ga]
[Ex ia IIC T4/T5/T6 Ga]
Zone 1 mounting to zone 0 gas [Ex ia IIC T4/T5/T6 Ga/Gb]
Zone 2 gas [Ex ic IIC T4/T5/T6 Gc X]
Zone 20 dust [Ex ia IIIB T200 135 °C Da]
[Ex ia IIIC T135 °C Da]
Zone 21 mounting to zone 20 dust [Ex ia IIIB T200 135 °C Da/Db]
[Ex ia IIIC T135 °C Da/Db]
Mining [Ex ia I Ma]
- Ex n Zone 2 gas [Ex nA IIC T4/T5/T6 Gc X]
- Ex t Zone 22 dust [Ex tc IIIC T90 °C Dc X]

EAC Eurasian Economic


■ EMC directive Community
■ Hazardous areas (see approval)

FM USA
Hazardous areas (see approval)
CSA USA and Canada
■ Safety (e.g. electr. safety, overpressure, ...)
■ Hazardous areas (see approval)

GOST Russia
Metrology, measurement technology
KazInMetr Kazakhstan
Metrology, measurement technology
- MTSCHS Kazakhstan
Permission for commissioning
BelGIM Belarus
Metrology, measurement technology
UkrSEPRO Ukraine
Metrology, measurement technology
Uzstandard Uzbekistan
Metrology, measurement technology
INMETRO Brazil
Metrology, measurement technology (see approval)
NEPSI China
Hazardous areas (see approval)

WIKA data sheet PE 81.58 ∙ 11/2020 Page 9 of 17


Logo Description Country
KCs (KOSHA) South Korea
Hazardous areas (see approval)
- PESO India
Hazardous areas (see approval)
3-A USA
®

Sanitary Standard

This instrument is 3-A marked, based on a third party verification for conformance to the 3-A standard number 74-07 (sensors
and sensor fittings and connections).

GL DNV GL International
Ships, shipbuilding (e.g. offshore)
- CRN Canada
Safety (e.g. electr. safety, overpressure, ...)

Manufacturer‘s information and certificates


Logo Description
- MTTF: > 100 years
- China RoHS directive

→ Approvals and certificates, see website

WIKA data sheet PE 81.58 ∙ 11/2020 Page 10 of 17


Dimensions in mm

Pressure transmitter
Bayonet connector Bayonet connector Circular connector M16 x 0.75
MIL-DTL-26482 MIL-DTL-26482 IEC 61076-2-106
(4-pin) adjustable (6-pin) adjustable (5-pin) adjustable

Circular connector M16 x 0.75 Circular connector M12 x 1 Circular connector M12 x 1
IEC 61076-2-106 IEC 61076-2-101 A-COD (4-pin) IEC 61076-2-101 A-COD
(5-pin) not adjustable adjustable (4-pin) not adjustable

Angular connector Angular connector


DIN EN 175301-803 A PG 9 DIN EN 175301-803 A ½ NPT
adjustable adjustable

WIKA data sheet PE 81.58 ∙ 11/2020 Page 11 of 17


Cable outlet IP67 Cable outlet IP68 Cable outlet IP68
adjustable Cable gland Cable gland conduit ½ NPT
not adjustable not adjustable

Cable outlet IP68 PUR Cable outlet IP68 FEP Cable outlet IP68
(permanent use in the medium) (permanent use in the medium) Cable gland
not adjustable not adjustable adjustable

WIKA data sheet PE 81.58 ∙ 11/2020 Page 12 of 17


Cable outlet IP67 with protective cap Field case Field case
not adjustable Conduit ½ NPT-I Cable gland
adjustable adjustable

Field case IS-3 for optional medium temperatures


Conduit M20 x 1.5-I -40 ... +150 °C [-40 ... 302 °F] and
adjustable -40 ... +200 °C [-40 ... +392 °F]

WIKA data sheet PE 81.58 ∙ 11/2020 Page 13 of 17


Pressure transmitters in high-pressure version

Angular connector Circular connector M12 x 1 Cable outlet IP67


DIN EN 175301-803 A PG 9 IEC 61076-2-101 A-COD (4-pin) adjustable
adjustable adjustable

Field case
Cable gland
adjustable

WIKA data sheet PE 81.58 ∙ 11/2020 Page 14 of 17


Process connections

G L1 G L1 G L1
G ¼ B EN 837 13 G¼A 14 ¼ NPT 13
G ½ B EN 837 20 G½A 17 ½ NPT 19
G ⅜ B EN 837 16 R¼ 13
M20 x 1.5 DIN 16288 20 R⅜ 15

G L1 G L1 G1 G2 L1 L2 L3
7/16-20 UNF BOSS 12.06 G ¼ B JIS B 7505- 16 G½B G¼ 20 15.5 13
76
9/16-18 UNF BOSS 12.85

G L1 L2 L3 D1 G L1 L2 L3 D1 G L1 L2 L3 D1
G½B 23 20.5 10 18 G1B 23 20.5 10 30 G1B 25 9 15.5 29.5
hygienic
Surface roughness of wetted metal parts, Ra ≤ 0.76 µm

WIKA data sheet PE 81.58 ∙ 11/2020 Page 15 of 17


Process connections for measuring ranges > 1,000 bar

G L1 D1 G L1 D1
M16 x 1.5 12 4.8 9/16-18 UNF F250-C 11.2 4.3
M20 x 1.5 15 4.8

Process connections for optional medium temperature ranges

-20 ... +150 °C [-4 ... +302 °F] -40 ... +150 °C [-40 ... +302 °F]
-40 ... +200 °C [-40 ... +392 °F]

G L1 L2 L3 L4 D1 G L1 L2
G½B 23 20.5 10 15.5 18 G½B 20 71
G1B 23 20.5 10 15.5 30

For information on tapped holes and welding sockets, see Technical information IN 00.14 at www.wika.com.

WIKA data sheet PE 81.58 ∙ 11/2020 Page 16 of 17


Accessories and spare parts

Mating connector (for ignition protection type Ex i)

Designation Order number


Angular connector DIN EN 175301-803 A
With gland, metric, with 2 m moulded cable 11225793
With gland, metric, with 5 m moulded cable 11250186
Circular connector M12 x 1
Angled version, 4-pin, IP67, for self-assembly 2421270
Straight version, 4-pin, IP67, for self-assembly 2421262

Sealings for mating connectors

Description Order number


Blue (WIKA) Brown (neutral)
Angular connector DIN EN 175301-803 A 1576240 11437902

Sealings for process connection

Process connection Order number


Copper Stainless steel NBR FKM
G ¼ B EN 837 11250810 11250844 - -
G ½ B EN 837 11250861 11251042 - -
M20 x 1.5 DIN 16288 11250861 11251042
G¼A - - 1537857 1576534
G½A - - 1039067 1039075

Repeater power supply

Description Order number


Repeater power supply model IS Barrier 14117118

Welding socket

Description Order number


Welding socket for G ½ B flush 1192299
Welding socket for G 1 B flush 1192264
Welding socket for G 1 B hygienic flush 14145179
Welding socket for G 1 B hygienic flush with leak-control channel ®
14145183
Fulfils the 3-A Sanitary Standards

Ordering information
Model / Measuring range / Accuracy / Process connection / Sealing / Electrical connection / Temperature range of medium
© 01/2015 WIKA Alexander Wiegand SE & Co. KG, all rights reserved.
The specifications given in this document represent the state of engineering at the time of publishing.
We reserve the right to make modifications to the specifications and materials.
11/2020 EN

WIKA data sheet PE 81.58 ∙ 11/2020 Page 17 of 17

WIKA Alexander Wiegand SE & Co. KG


Alexander-Wiegand-Straße 30
63911 Klingenberg/Germany
Tel. +49 9372 132-0
Fax +49 9372 132-406
[email protected]
www.wika.de