Pressure Transmitter - Data Sheet
Pressure Transmitter - Data Sheet
Pressure transmitter
For applications in hazardous areas
Model IS-3
WIKA data sheet PE 81.58
Applications
■ Chemical, petrochemical industry
■ Oil, natural gas
■ Machine building
Special features
■ Measuring ranges from 0 ... 0.1 to 0 ... 6,000 bar [0 ... 3 to
0 ... 15,000 psi]
■ Approved for use in hazardous areas, e.g. ATEX, IECEx,
FM and CSA
Description
For the highest demands The process connections with flush diaphragm are
The pressure transmitters of the IS-3 series have been particularly suitable for the measurement of viscous and
specifically designed for the highest industrial requirements contaminated media and ensure trouble-free pressure
in hazardous areas and feature the common approvals, such measurement at all times.
as ATEX, IECEx, FM and CSA.
The optional field case of the model IS-3 enables operation
The model IS-3 pressure transmitter is available with in extreme environmental conditions and is resistant to
measuring ranges up to 6,000 bar and is suitable for acids, bases, oils and solvents. Via the field case connection
applications ranging from general machine building to integrated into the case's head, the electrical cabling can be
high-pressure applications. installed quickly and easily.
Absolute pressure
bar 0 ... 0.25 0 ... 0.4 0 ... 0.6 0 ... 1 0 ... 1.6 0 ... 2.5 0 ... 4
0 ... 6 0 ... 10 0 ... 16 0 ... 25
psi 0 ... 5 0 ... 10 0 ... 15 0 ... 30 0 ... 60 0 ... 100 0 ... 160
0 ... 200 0 ... 300
Overload safety
The overload safety is based on the sensor element used. Depending on the selected process connection and sealing,
restrictions in overload safety can result.
A higher overload safety will result in a higher temperature error.
1) 1.7-fold overload safety with 1,000 psi, 1,500 psi, 4,000 psi and 6,000 psi
Supply voltage
DC 24 V
Voltage supply
Supply voltage U+
Model IS-3: DC 10 ... 30 V Time response
Model IS-3 with field case: DC 11 ... 30 V
Settling time
Supply and signal circuit for ATEX/IECEx ignition ≤ 2 ms
protection type Ex i (see product label) ≤ 10 ms for medium temperatures below -30 °C [-22 °F]
Voltage: Ui = DC 30 V
Current: Ii = 100 mA
Power: Group I (mines susceptible to firedamp): Pi =
Accuracy specifications
800 mW
Group II (explosive gas atmosphere other than
Accuracy at reference conditions
mines): Pi = 800 mW
Group IIIB (explosive gas atmosphere other Accuracy
than mines): Pi = 800/650 mW
Standard ≤ ±0.5 % of span
Group IIIC (explosive gas atmosphere other
Option ≤ ±0.25 % of span 1)
than mines): Pi = 750/650/550 mW
1) Only for measuring ranges ≥ 0.25 bar [3 psi] and ≤ 1,000 bar [15,000 psi]
Effective internal capacitance (version with non-detachable
cable connection) Including non-linearity, hysteresis, zero offset and end value
Ci ≤ 16.5 nF deviation (corresponds to measured error per IEC 61298-2).
Ci ≤ 16.5 nF + 0.2 nF/m
Non-linearity (IEC 61298-2)
Effective internal inductance (version with non-detachable ≤ ±0.2 % of span BFSL
cable connection)
Li = 0 μH Non-repeatability
Li = 0 μH + 2 μH/m < 0.1 % of span
Supply and signal circuit for CSA and FM (see product Mean temperature coefficient of zero point
label) [0 ... 80 °C / 32 ... 176 °F]
Entity/non-incendive parameters: Measuring range ≤ 0.25 bar: ≤ ±0.4 % of span/10 K
Vmax/Ui = 30 V Measuring range > 0.25 bar: ≤ ±0.2 % of span/10 K
Imax/Ii = 100 mA at ambient temperature ≤ 85 °C [185 °F]
Imax/Ii = 87 mA at ambient temperature > 85 °C [185 °F] Mean temperature coefficient of span
Pmax/Pi = 0.8 W [0 ... 80 °C / 32 ... 176 °F]
Ci = 16.5 nF (flying leads: + 0.2 nF/m) ≤ ±0.2 % of span/10 K
Li = 0 μH (flying leads: + 2 μH/m)
Long-term stability at reference conditions
≤ ±0.2 % of span/year
Process connections
1) Restrictions depending on sealing material, see table “Sealing material restrictions for G ½ B flush process connection“
1) Permissible temperature range: -20 ... +100 °C [-4 ... +212 °F]
2) Permissible temperature range: -15 ... +200 °C [5 ... 392 °F]
3) Permissible temperature range: -40 ... +150 °C [-40 ... +302 °F]
4) See also table “Sealing material restrictions for G ½ B flush process connection” with regard to overload safety.
Except for sealings for process connections per EN 837 the sealings listed under “Standard” are included in the delivery.
T = Ambient temperature
N/A = Not applicable
Electrical connections
Available connections
see “Dimensions in mm”
Insulation voltage
DC 500 V
Assignment (2- U+ = 1 U- = 2 U+ = 1 U- = 3 U+ = A U- = B
wire)
Cable shield - - -
Wire cross-section Max. 1.5 mm² - -
Cable diameter 6 ... 8 mm - -
Ship approval: 10 ... 14 mm
Legend
U+ Positive power supply terminal
U- Negative power supply terminal
S+ Analogue output
Test+ Positive test connection
Test- Negative test connection
Permissible temperature ranges for operation in accordance with the data sheet specifications (for ignition
protection type Ex i)
Available options
Standard -20 ... +80 °C [-4 ... +176 °F]
Option 1 -20 ... +150 °C [-4 ... +302 °F] (only for flush process connections and measuring ranges ≤ 600 bar [8,000 psi])
Option 2 -40 ... +150 °C [-40 ... +302 °F] (only for process connections with pressure port and measuring ranges ≤ 400 bar [5,000 psi])
Option 3 -40 ... +200 °C [-40 ... +392 °F] (only for process connections with pressure port and measuring ranges ≤ 400 bar [5,000 psi])
Oxygen -20 ... +60 °C [-4 ... +140 °F]
Permissible temperature ranges for operation in accordance with the data sheet specifications (for ignition
protection types Ex nA and Ex tc)
■ Medium: -15 ... +70 °C [5 ... +158 °F] (with oxygen -15 ... +60 °C [5 ... +140 °F])
■ Ambient: -15 ... +70 °C [5 ... +158 °F]
■ Storage: -15 ... +70 °C [5 ... +158 °F]
Materials
Wetted parts
■ Measuring ranges ≤ 25 bar and ≤ 400 psi, process connection G ½ B flush and G 1 B flush: 316Ti
■ Measuring ranges ≥ 40 ... ≤ 1,000 bar and ≥ 500 ... ≤ 15,000 psi: 316Ti and S13800
■ Measuring ranges > 1,000 bar: S13800
■ Process connection G 1 B flush, hygienic: 316L
■ Measuring ranges ≤ 25 bar and ≤ 400 psi with process connection with pressure port for optional medium temperature
range: 316L and 316Ti
■ Measuring ranges > 25 bar and > 400 psi with process connection with pressure port for optional medium temperature
range: 316L, 316Ti and S13800
Non-wetted parts
■ Case: Stainless steel
■ Angular connector DIN EN 175301-803 A: PA6
■ Circular connector M12 x 1 adjustable: PA6, stainless steel
■ Circular connector M12 x 1 not adjustable: Stainless steel
■ Circular connector M16 x 0.75 adjustable: PA6, stainless steel, Zn nickel-plated
■ Circular connector M16 x 0.75 not adjustable: Stainless steel, Zn nickel-plated
■ Bayonet connector adjustable: PA6, stainless steel, Al nickel-plated
■ Cable outlet IP67: PA6, stainless steel, nickel-plated brass
■ Cable outlet IP67 with protective cap: Stainless steel, PA66/6-FR
■ Cable outlet IP68 cable gland: Stainless steel, nickel-plated brass
■ Cable outlet IP68: Stainless steel
■ Field case: Stainless steel, nickel-plated brass / stainless steel
■ Internal pressure transmission medium
- No oxygen version: Synthetic oil
- Oxygen version: Halocarbon oil
- Instruments with measuring range > 25 bar [400 psi]: Dry measuring cell
IECEx International
Hazardous areas
- Ex i Zone 0 gas [Ex ia IIA T4/T5/T6 Ga]
[Ex ia IIC T4/T5/T6 Ga]
Zone 1 mounting to zone 0 gas [Ex ia IIC T4/T5/T6 Ga/Gb]
Zone 2 gas [Ex ic IIC T4/T5/T6 Gc X]
Zone 20 dust [Ex ia IIIB T200 135 °C Da]
[Ex ia IIIC T135 °C Da]
Zone 21 mounting to zone 20 dust [Ex ia IIIB T200 135 °C Da/Db]
[Ex ia IIIC T135 °C Da/Db]
Mining [Ex ia I Ma]
- Ex n Zone 2 gas [Ex nA IIC T4/T5/T6 Gc X]
- Ex t Zone 22 dust [Ex tc IIIC T90 °C Dc X]
FM USA
Hazardous areas (see approval)
CSA USA and Canada
■ Safety (e.g. electr. safety, overpressure, ...)
■ Hazardous areas (see approval)
GOST Russia
Metrology, measurement technology
KazInMetr Kazakhstan
Metrology, measurement technology
- MTSCHS Kazakhstan
Permission for commissioning
BelGIM Belarus
Metrology, measurement technology
UkrSEPRO Ukraine
Metrology, measurement technology
Uzstandard Uzbekistan
Metrology, measurement technology
INMETRO Brazil
Metrology, measurement technology (see approval)
NEPSI China
Hazardous areas (see approval)
Sanitary Standard
This instrument is 3-A marked, based on a third party verification for conformance to the 3-A standard number 74-07 (sensors
and sensor fittings and connections).
GL DNV GL International
Ships, shipbuilding (e.g. offshore)
- CRN Canada
Safety (e.g. electr. safety, overpressure, ...)
Pressure transmitter
Bayonet connector Bayonet connector Circular connector M16 x 0.75
MIL-DTL-26482 MIL-DTL-26482 IEC 61076-2-106
(4-pin) adjustable (6-pin) adjustable (5-pin) adjustable
Circular connector M16 x 0.75 Circular connector M12 x 1 Circular connector M12 x 1
IEC 61076-2-106 IEC 61076-2-101 A-COD (4-pin) IEC 61076-2-101 A-COD
(5-pin) not adjustable adjustable (4-pin) not adjustable
Cable outlet IP68 PUR Cable outlet IP68 FEP Cable outlet IP68
(permanent use in the medium) (permanent use in the medium) Cable gland
not adjustable not adjustable adjustable
Field case
Cable gland
adjustable
G L1 G L1 G L1
G ¼ B EN 837 13 G¼A 14 ¼ NPT 13
G ½ B EN 837 20 G½A 17 ½ NPT 19
G ⅜ B EN 837 16 R¼ 13
M20 x 1.5 DIN 16288 20 R⅜ 15
G L1 G L1 G1 G2 L1 L2 L3
7/16-20 UNF BOSS 12.06 G ¼ B JIS B 7505- 16 G½B G¼ 20 15.5 13
76
9/16-18 UNF BOSS 12.85
G L1 L2 L3 D1 G L1 L2 L3 D1 G L1 L2 L3 D1
G½B 23 20.5 10 18 G1B 23 20.5 10 30 G1B 25 9 15.5 29.5
hygienic
Surface roughness of wetted metal parts, Ra ≤ 0.76 µm
G L1 D1 G L1 D1
M16 x 1.5 12 4.8 9/16-18 UNF F250-C 11.2 4.3
M20 x 1.5 15 4.8
-20 ... +150 °C [-4 ... +302 °F] -40 ... +150 °C [-40 ... +302 °F]
-40 ... +200 °C [-40 ... +392 °F]
G L1 L2 L3 L4 D1 G L1 L2
G½B 23 20.5 10 15.5 18 G½B 20 71
G1B 23 20.5 10 15.5 30
For information on tapped holes and welding sockets, see Technical information IN 00.14 at www.wika.com.
Welding socket
Ordering information
Model / Measuring range / Accuracy / Process connection / Sealing / Electrical connection / Temperature range of medium
© 01/2015 WIKA Alexander Wiegand SE & Co. KG, all rights reserved.
The specifications given in this document represent the state of engineering at the time of publishing.
We reserve the right to make modifications to the specifications and materials.
11/2020 EN