TeSys Deca Contactors - LC1D115M7

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Lembar data produk

Spesifikasi

TeSys D contactor - 3P(3 NO) -


AC-3 - <= 440 V 115 A - 220 V AC
50/60 Hz coil
LC1D115M7

Price : 4.234.450,00 IDR

Disklaimer: Dokumentasi ini tidak ditujukan sebagai pengganti dan tidak untuk digunakan untuk menentukan kesesuaian atau keandalan produk ini untuk aplikasi pengguna
Main
Range TeSys

Product name TeSys D


TeSys Deca

Product or component type Contactor

Device short name LC1D

Contactor application Motor control


Resistive load

Utilisation category AC-4


AC-1
AC-3

Poles description 3P

Power pole contact composition 3 NO

[Ue] rated operational voltage Power circuit: <= 1000 V AC 25...400 Hz


Power circuit: <= 300 V DC

[Ie] rated operational current 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

Motor power kW 30 kW at 220...230 V AC 50/60 Hz (AC-3)


55 kW at 380...400 V AC 50/60 Hz (AC-3)
59 kW at 415...440 V AC 50/60 Hz (AC-3)
75 kW at 500 V AC 50/60 Hz (AC-3)
80 kW at 660...690 V AC 50/60 Hz (AC-3)
65 kW at 1000 V AC 50/60 Hz (AC-3)
18.5 kW at 400 V AC 50/60 Hz (AC-4)

Motor power HP (UL / CSA) 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors


40 hp at 230/240 V AC 50/60 Hz for 3 phases motors
75 hp at 460/480 V AC 50/60 Hz for 3 phases motors
100 hp at 575/600 V AC 50/60 Hz for 3 phases motors

Control circuit type AC at 50/60 Hz

[Uc] control circuit voltage 220 V AC 50/60 Hz

Auxiliary contact composition 1 NO + 1 NC

[Uimp] rated impulse withstand 8 kV conforming to IEC 60947


voltage

Overvoltage category III

[Ith] conventional free air 200 A (at 60 °C) for power circuit
thermal current

Irms rated making capacity 1260 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1

19 Feb 22 1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand 250 A 40 °C - 10 min for power circuit


current 550 A 40 °C - 1 min for power circuit
950 A 40 °C - 10 s for power circuit
1100 A 40 °C - 1 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit

Associated fuse rating 250 A gG at <= 690 V coordination type 1 for power circuit
200 A gG at <= 690 V coordination type 2 for power circuit
10 A gG for signalling circuit

Average impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit

[Ui] rated insulation voltage Power circuit: 600 V CSA certified


Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified

Electrical durability 0.8 Mcycles 200 A AC-1 at Ue <= 440 V


0.95 Mcycles 115 A AC-3 at Ue <= 440 V

Power dissipation per pole 24 W AC-1


7.9 W AC-3

Front cover With

Mounting support Rail


Plate

Standards CSA C22.2 No 14


EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508

Product certifications RINA


CSA
CCC
BV
LROS (Lloyds register of shipping)
GL
GOST
DNV
UL
UKCA

Connections - terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Power circuit: connector 1 cable(s) 10…120 mm²flexible without cable end
Power circuit: connector 2 cable(s) 10…50 mm²flexible without cable end
Power circuit: connector 1 cable(s) 10…120 mm²flexible with cable end
Power circuit: connector 2 cable(s) 10…50 mm²flexible with cable end
Power circuit: connector 1 cable(s) 10…120 mm²solid without cable end
Power circuit: connector 2 cable(s) 10…50 mm²solid without cable end

Tightening torque Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 12 N.m - on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

Operating time 6...20 ms opening


20...50 ms closing

Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Mechanical durability 8 Mcycles

Maximum operating rate 2400 cyc/h 60 °C

Complementary
Coil technology Built-in bidirectional peak limiting diode suppressor

Control circuit voltage limits 0.3...0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz


0.8...1.15 Uc (-40…55 °C):operational AC 50/60 Hz
1...1.15 Uc (55…70 °C):operational AC 50/60 Hz

Inrush power in VA 280…350 VA 60 Hz cos phi 0.8 (at 20 °C)

2
19 Feb 22
280…350 VA 50 Hz cos phi 0.8 (at 20 °C)

Hold-in power consumption in 2…18 VA 60 Hz cos phi 0.3 (at 20 °C)


VA 2…18 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation 3…8 W at 50/60 Hz

Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1


type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency 25...400 Hz

Minimum switching current 5 mA for signalling circuit

Minimum switching voltage 17 V for signalling circuit

Non-overlap time 1.5 ms on de-energisation between NC and NO contact


1.5 ms on energisation between NC and NO contact

Insulation resistance > 10 MOhm for signalling circuit

Environment
IP degree of protection IP20 front face conforming to IEC 60529

Protective treatment TH conforming to IEC 60068-2-30

Pollution degree 3

Ambient air temperature for -40…60 °C


operation 60…70 °C with derating

Ambient air temperature for -60…80 °C


storage

Operating altitude 0...3000 m

Fire resistance 850 °C conforming to IEC 60695-2-1

Mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz


Vibrations contactor closed: 4 Gn, 5...300 Hz
Shocks contactor closed: 15 Gn for 11 ms
Shocks contactor open: 6 Gn for 11 ms

Height 158 mm

Width 120 mm

Depth 136 mm

Net weight 2.5 kg

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Weight 2.469 kg

Package 1 Height 17 cm

Package 1 width 18.8 cm

Package 1 Length 21 cm

Unit Type of Package 2 P06

Number of Units in Package 2 27

Package 2 Weight 79.66 kg

Package 2 Height 73.5 cm

Package 2 width 60 cm

Package 2 Length 80 cm

Package 3 Height 80 cm

19 Feb 22 3
Offer Sustainability
Sustainable offer status Green Premium product

REACh Regulation REACh Declaration

EU RoHS Directive Compliant


EU RoHS Declaration

Mercury free Yes

RoHS exemption information Yes

China RoHS Regulation China RoHS declaration


Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure Product Environmental Profile

Circularity Profile End of Life Information

WEEE The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins

PVC free Yes

Contractual warranty
Warranty 12 months

4
19 Feb 22
Lembar data produk LC1D115M7
Dimensions Drawings

Dimensions

(1) Minimum electrical clearance

LC1 D115 and D150 (3-pole)

a 120

b1 with LA4 DA2 174

with LA4 DF, DT 185

with LA4 DM, DL 188

with LA4 DW 188

c without cover or add-on blocks 132

with cover, without add-on blocks 136

c1 with LAD N or C (2 or 4 contacts) 150

c2 with LA6 DK20 155

c3 with LAD T, R, S 168

with LAD T, R, S and sealing cover 172

19 Feb 22 5
Lembar data produk LC1D115M7
Connections and Schema

Wiring

6
19 Feb 22

You might also like