17.0 HP Hammer Glass Capsules Product Catalogue

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

HP HAMMER

GLASS CAPSULES

FEATURES RANGE OF CONCRETE QUALITY


• Totally encapsulated system, excellent for “one- C20/25 ~ C50/60
hole to one-capsule”application.
• Stress-free anchoring, suitable for close edge
and tight spacing applications. RANGE
KG.
OF LOADING KG.
Medium loads
KG.
• No special tool needed for installation except a 5.1 kN ~ 128.0 kN (SWL)
hammer.
• Speedy installation for rebar and threaded stud. HOLE ORIENTATION
• Suitable for high dynamic loading in solid
substrate.
• High efficiency in series installation, highly
Floor Wall Overhead Hollow
recommended for floor and wall fixings.

APPLICATIONS BASE MATERIALS


• High strength anchoring where vibration is a
consideration. Concrete Concrete block
• All types of façade and curtain wall installations. solid stone
• Hold down anchoring for machineries, fans and
motors.
• Anchoring for steel structures and gondolas. VA RODS AVAILABILITY
• Balustrades, handrails, safety barriers
installations.
• Recommended for architectural or GFRC panel
fixings.
• Shear connectors for reinforced concrete structure.
APPROVAL GOVERNING BODIES
SHELF LIFE
• Shelf life is 18 months with the capsules kept in
cool dry conditions (+5ºC to +25ºC) out of direct
sunlight.

Page 58
ORDERING DETAILS

PRODUCT DESCRIPTION PACKING CONTENT (PCs.) PRODUCT PART NO.

Hole Blower 1 HCP

Hole Cleaning Brush


Cleaning Brush - 10mm 1 CB10
Cleaning Brush - 12mm 1 CB12
Cleaning Brush - 18mm 1 CB18
Cleaning Brush - 28mm 1 CB28

HP HAMMER GLASS CAPSULE

PRODUCT CAPSULE DIAMETER CAPSULE VOLUME PACKING CONTENT PRODUCT PART


DESCRIPTION (mm) (ml) (PCs.) NO.
M8 x 80mm 9 4.0 10 HP8
M10 x 90mm 11 6.4 10 HP10
M12 x 110mm 13 11.3 10 HP12
M16 x 125mm 17 23.1 10 HP16
M20 x 175mm 22 53.0 6 HP20
M24 x 210mm 24 76.0 6 HP24
M30 x 265mm 33 191.0 6 HP30

VA CHEMICAL STUD RODS - STEEL CLASS 5.8 ZINC GALVANISED

PRODUCT FIXTURE HOLE DIAMETER MAX. FIXTURE THICKNESS PACKING CONTENT PRODUCT PART
DESCRIPTION (mm) (mm) (PCs.) NO.
M8 x 110mm 9 15 10 VA8110
M10 x 130mm 12 20 10 VA10130
M12 x 160mm 14 30 10 VA12160
M16 x 190mm 18 40 10 VA16190
M20 x 260mm 22 50 6 VA20260
M24 x 300mm 28 55 6 VA24300
M30 x 380mm 33 70 6 VA30380

VA CHEMICAL STUD RODS - STEEL CLASS 5.8 HOT-DIPPED GALVANISED

PRODUCT FIXTURE HOLE DIAMETER MAX. FIXTURE THICKNESS PACKING CONTENT PRODUCT PART
DESCRIPTION (mm) (mm) (PCs.) NO.
M8 x 110mm 9 15 10 VA8110GH
M10 x 130mm 12 20 10 VA10130GH
M12 x 160mm 14 30 10 VA12160GH
M16 x 190mm 18 40 10 VA16190GH
M20 x 260mm 22 50 6 VA20260GH
M24 x 300mm 28 55 6 VA24300GH
M30 x 380mm 33 70 6 VA30380GH

VAH CHEMICAL STUD RODS - STEEL CLASS 8.8 ZINC GALVANISED

PRODUCT FIXTURE HOLE DIAMETER MAX. FIXTURE THICKNESS PACKING CONTENT PRODUCT PART
DESCRIPTION (mm) (mm) (PCs.) NO.
M8 x 110mm 9 15 10 VAH8110
M10 x 130mm 12 20 10 VAH10130
M12 x 160mm 14 30 10 VAH12160
M16 x 190mm 18 40 10 VAH16190
M20 x 260mm 22 50 6 VAH20260
M24 x 300mm 28 55 6 VAH24300
M30 x 380mm 33 70 6 VAH30380

Page 59
HP HAMMER GLASS CAPSULE FOR POST-INSTALLED REBAR APPLICATIONS
(Design Load Approach with BS8110 Bond Strength Method)

Concrete Compressive Strength: fck,cube = 30 N/mm2

Rebar Size, ds ϕ10 ϕ12 ϕ16 ϕ20 ϕ25 ϕ32


Design Steel Resistance, NRd,s [kN] 31.4 45.2 80.4 125.7 196.4 321.7
Design Bond Stress, tRd [N/mm2] 6.8 6.1 6.1 6.1 5.8 5.8
Drilled Hole Diameter, do [mm] 13 ~ 14 15 ~ 16 20 ~ 22 25 ~ 28 30 ~ 32 40 ~ 42
Bar Spacing, s [mm] 50 65 80 100 125 160
Edge Distance, c [mm] 40 40 40 50 65 80
Lb,rqd / Rebar ϕ 20 20 20 20 20 20
Design Tensile Bonding Capacity, NRd [kN]
Anchorage Length, Lb [mm]
(Single Capsule Application)
100 21.5
120 27.7 “Minimum depth to develop
160 49.3 full steel shear”
200 77.0
250 114.5
320 187.6
Design Tensile Bonding Capacity, NRd [kN]
Anchorage Length, Lb [mm]
(Double Capsule Application)
200 31.4
240 45.3 “Minimum depth to develop
320 80.5 full steel shear”
400 125.7
500 196.4
640 321.7
Length to Develop Steel Yield, Lb,rqd [mm] 200 240 320 400 500 640

1) Safety factor for design tensile steel resistance: gMs,N = 1.15 (based on steel yield strength of 460 N/mm ).
2

2) Safety factor for design tensile pull-out resistance: gMc,N = 1.8.


3) Safety factor for design tensile concrete cone resistance: gMc,N = 1.5.
4) Loading applicable to non-cracked concrete with design comply in accordance to BS8110.
5) Minimum spacing shall be 4ds bar to bar or 5ds centre-to-centre.
6) Minimum edge distance shall be 2ds bar to bar or 2.5ds centre-to-centre.

SUGGESTED APPLICATIONS

ℓy
ℓo

>10ds

Overlap joints for slabs and beams or foundation column or wall; rebar connection for simply supported slabs or beams; shear connector or compression component joints.

Important note: Architect or design engineer must conduct final checked with the actual site condition for any variations against tabulated data.

SETTING DIAGRAM INSTALLATION PROCEDURE


hmin 1. 2. 3. 4. 5.

Lb

do ds

Page 62
HP HAMMER GLASS CAPSULE FOR POST-INSTALLED REBAR APPLICATIONS
(Design Load Approach with BS8110 Bond Strength Method)

Concrete Compressive Strength: fck,cube = 35 N/mm2

Rebar Size, ds ϕ10 ϕ12 ϕ16 ϕ20 ϕ25 ϕ32


Design Steel Resistance, NRd,s [kN] 31.4 45.2 80.4 125.7 196.4 321.7
Design Bond Stress, tRd [N/mm2] 7.2 6.4 6.4 6.4 6.1 6.1
Drilled Hole Diameter, do [mm] 13 ~ 14 15 ~ 16 20 ~ 22 25 ~ 28 30 ~ 32 40 ~ 42
Bar Spacing, s [mm] 50 65 80 100 125 160
Edge Distance, c [mm] 40 40 40 50 65 80
Lb,rqd / Rebar ϕ 20 20 20 20 20 20
Design Tensile Bonding Capacity, NRd [kN]
Anchorage Length, Lb [mm]
(Single Capsule Application)
100 22.5
120 29.0 “Minimum depth to develop
160 51.6 full steel shear”
200 80.6
250 119.9
320 196.4
Design Tensile Bonding Capacity, NRd [kN]
Anchorage Length, Lb [mm]
(Double Capsule Application)
200 31.4
240 45.3 “Minimum depth to develop
320 80.5 full steel shear”
400 125.7
500 196.4
640 321.7
Length to Develop Steel Yield, Lb,rqd [mm] 200 240 320 400 500 640

1) Safety factor for design tensile steel resistance: gMs,N = 1.15 (based on steel yield strength of 460 N/mm ).
2

2) Safety factor for design tensile pull-out resistance: gMc,N = 1.8.


3) Safety factor for design tensile concrete cone resistance: gMc,N = 1.5.
4) Loading applicable to non-cracked concrete with design comply in accordance to BS8110.
5) Minimum spacing shall be 4ds bar to bar or 5ds centre-to-centre.
6) Minimum edge distance shall be 2ds bar to bar or 2.5ds centre-to-centre.

SUGGESTED APPLICATIONS

ℓy
ℓo

>10ds

Overlap joints for slabs and beams or foundation column or wall; rebar connection for simply supported slabs or beams; shear connector or compression component joints.

Important note: Architect or design engineer must conduct final checked with the actual site condition for any variations against tabulated data.

SETTING DIAGRAM INSTALLATION PROCEDURE


hmin 1. 2. 3. 4. 5.

Lb

do ds

Page 63