2017 Smart IO Brochure
2017 Smart IO Brochure
Moxa is a leading provider of edge connectivity, industrial computing, and network infrastructure solutions
for enabling connectivity for the Industrial Internet of Things (IIoT). With over 30 years of industry
experience, Moxa has connected more than 65 million devices worldwide and has a distribution and
service network that reaches customers in more than 80 countries. Moxa delivers lasting business value by
empowering industries with reliable networks and sincere service. Information about Moxa’s solutions is
available at www.moxa.com.
UK Russia Shenzhen
Tel: +44-1844-355-601 Tel: +7-495-287-0929 Tel: +86-755-8368-4084/94
Fax: +44-1844-353-553 Fax: +7-495-269-0929 Fax: +86-755-8368-4148
[email protected] [email protected] [email protected]
Korea
Tel: +82-2-6268-4048
Fax: +82-2-6268-4044
[email protected]
Modular Programmable Smart Remote I/O Smart Remote I/O Remote I/O Automation Software
Controller with Click&Go Plus with Click&Go
Private Cloud
Deploying Data to a Private Cloud Deploying Data to Private and Deploying Data to a Public Cloud
Public Clouds (Hybrid Cloud)
Private clouds are implemented within a corporate firewall, Public clouds are a form of cloud computing in which a
under the control of the IT department. Data is transferred A hybrid cloud combines private clouds and public clouds, company relies on a third-party cloud service provider,
from monitored systems through the corporate intranet or in which critical data often resides in the enterprise’s such as Microsoft Azure, who provides services such as
Public Cloud virtual private network to the private cloud. servers, data storage, and applications.
private cloud, while other data is stored in and accessible
from a public cloud.
Moxa’s Smart I/O can poll local meters and sensors as Moxa’s programmable Smart I/O can be easily embedded
frequently as it likes without putting any burden on the Moxa’s MX-AOPC UA Logger allows users to easily deploy with SDKs from cloud service providers for connecting
Ethernet network, and only sends readings to the data to a private cloud or public cloud without any Smart I/O to a public cloud. Moxa Smart I/O supports
MX-AOPC UA Server (over the Ethernet network) when programming effort. Data sent to a public cloud is multiple protocols, including Modbus and SNMP, to collect
Table of Contents certain pre-configured conditions are met. Moxa’s data from meters and sensors as frequently as needed.
converted from OPC tag format to the format that the
MX-AOPC UA Server receives real-time data from Smart public cloud supports, such as JSON files, and includes all Smart I/O’s tag-centric service represents each I/O value
Deploy Your I/O Data to the Cloud 1
I/O and converts data to the OPC UA standard, which is OPC-tag attributes, such as tag ID, value, unit, and or status as a tag. Each tag can be easily sent to a public
Moxa’s Technology Enables Seamless and Efficient Data Collection 3 secure and widely adopted in Industrial 4.0 applications for timestamp. Data is easily integrated by the public cloud’s cloud using C/C++ programming tools. Moreover, Smart
Application Notes 11 sending data to SCADA software. MX-AOPC UA Logger is services, such as dashboards, analytics tools, and I/O’s programmable capabilities allow users to minimize
an OPC UA client for converting data from MX-AOPC UA database storage. data size before sending data to a public cloud to ensure
Selection Guide 15
Server to a database. data quality and reduce transmission and storage costs.
1 www.moxa.com/Smart_IO 2
Deploy Your I/O Data to the Cloud
Data Collection use different technologies. Moxa’s Smart I/O can understand both IT and OT protocols. Once it
collects the I/O signals, it converts the data to both IT and OT protocols.
Machine Original Equipment Manufacturing ioLogik E1200 Series, ioLogik P1200 Series
With more and more field devices being connected to the industrial IoT (Internet of Things), the need to keep all Critical Power Management ioLogik E1230EM Series, ioLogik E1200 Series
those “things” continuously connected to the Internet has put a premium on networking products that can deliver
Wind Power Transformer Monitoring ioLogik E1200H Series, ioLogik E1200W Series
continuous connectivity without human intervention. To deploy your I/O data to the cloud easily and effortlessly, Smart Energy
Solar Grid and Inverter Monitoring ioLogik 2500 Series, ioLogik E1200 Series
you first need to retrieve the I/O data and then convert it to the appropriate protocol. Once all of the data has been
prepared for transmission, the final step is to push the data up to your cloud platform. Oil & Gas Wellhead, Pipeline Monitoring ioLogik 2500 Series, ioLogik E1200 Series
Water and Wastewater Wellhead, Pump, and ioLogik 2500 Series, ioLogik E1200 Series
Pipeline Monitoring
Smart City Disaster Prevention System ioLogik 2500 Series
ioLogik E1200 Series, ioLogik P1200 Series,
Surveillance System
ioLogik E2200 Series
3 www.moxa.com/Smart_IO 4
Deploy Your I/O Data to the Cloud
SCADA MES
Easily connect to the IIoT Reduce your integration cost by using SNMP or RESTful APIs to
without installing a separate collect data from the Smart I/O device, without needing to install
an extra protocol gateway to connect to IIoT applications.
protocol gateway
I/0I/0I/0
I/0 I/0
I/0
I/0 I/0
I/0
I/0
I/0
I/0 I/0 I/0 I/0
0 I/0 0 0 I/0 I/
I/I/0
0/I I/0
I/ I/0
I/0
100 meters
Smart I/O
PLC
I/O to IT/OT Protocol Conversion
Are you still looking for a protocol gateway to translate back and forth between OT and IT protocols? Moxa’s Smart I/O does just what
you need by supporting the most often-used protocols for retrieving I/O data. Most IT engineers use SNMP or RESTful API
Easily expand PLC I/O points, Moxa's Smart I/O devices are designed for a wide range of
especially in harsh operating temperatures, making them ideal for collecting data
protocols, but Industrial Automation (IA) engineers are more familiar with Operational Technologies (OT), such as Modbus and EtherNet/IP. from harsh environment applications. The ioLogik E1200
Moxa Smart I/O makes it possible for both IT and IA engineers to conveniently retrieve data from the same I/O device. environments
supports the most common PLC-type protocols, including
Modbus/TCP and EtherNet/IP.
Moxa's multiprotocol Smart I/O speaks six different protocols, including the Modbus/TCP, EtherNet/IP, and Moxa AOPC OT protocols, as
well as the SNMP, RESTful API, and Moxa MXIO library IT protocols. The Smart I/O retrieves I/O data and converts the data to any of
these protocols at the same time, allowing you to get your applications connected easily and effortlessly.
OT Protocols IT Protocols
AOPC Protocol
Product Series
Modbus EtherNet/IP AOPC SNMP RESTful API MXIO Library
–
MX-AOPC UA Server
ioLogik P1200 Series
Please check Moxa's website for the most up-to-date product specifications.
Actively and easily collect data Use Moxa’s MX-AOPC UA Server to connect to the Smart I/O
to use in your own system device with the AOPC protocol, and enjoy the benefits of “push
technology.” If you would like to program your own system,
Moxa’s MXIO Library helps you complete your tasks easily, both
for Windows and Linux operating systems.
5 www.moxa.com/Smart_IO 6
Deploy Your I/O Data to the Cloud
Data Collection turnkey solution that provides real-time data acquisition, data buffering in local storage devices, and
automatic data completeness after network failures. MX-AOPC UA Logger imports data from MX-AOPC
UA Server into a database in real time. When the network fails and then recovers, the logger automatically
retrieves data logs, with timestamp matching the duration of the disconnection, from the data buffers of
specific ioLogik 2500 devices, and then pushes the supplementary data into the database.
UA Logger
Private Cloud Public Cloud
Automatic Data
Completeness
Smart I/O
7 www.moxa.com/Smart_IO 8
Deploy Your I/O Data to the Cloud
9 www.moxa.com/Smart_IO 10
Smart Factory Smart Energy
Machine Condition Monitoring with Hybrid Cloud Solution Background and Background and Critical Power Management at a Data Center
Steady state and transient data collection Requirements Requirements Reliable I/O for critical event recording
Improve production OEE Ensure power stability and
(Overall Equipment longevity
Effectiveness) in a factory Customer needs:
Control Room
Private Cloud Public Cloud Customer needs: •3-phase AC power monitoring
•Some data needs to be with data recording for
sent to a public cloud based event tracking ioLogik E1230EM
on an existing private •Modbus and SNMP - 3-phase AC power monitoring
Server Room - Data recording for event tracking
cloud solution protocols
•Solutions for collecting
SCADA Database steady state and
streaming data
OPC UA/DA ODBC
Data Center
OPC UA
Hybrid Cloud
Why Moxa? Why Moxa? UPS
Con
troll
•Easy to deploy data to both •Supports 3-phase AC power er
MX-AOPC UA MX-AOPC UA
Server Logger private and public clouds data pre-recording
•Automatic data supplement •Supports both Modbus and Aut
ensures data integrity SNMP protocols om
Moxa AOPC atic
Tra
•Daisy-chain topology for nsfe
r Sw
easy I/O expansion itch
Field Site Data Supplement
ioLogik E1200 series
- Supports multiple protocols
- Easy deployment
ioLogik 2500 series ioPAC 8500 Series
- Oil pressure, level, temp…. - Motor voltage or
- Machine on/off…. current status
Semiconductor Equipment Manufacturing Background and Background and Solar Power System Monitoring
Requirements Requirements
PoE Switch and I/O for Machine Data Collection Remote I/O for energy data collection
Machine OEM to reduce Ensure solar power
total cost of ownership generation efficiency
Customer needs: Customer needs:
•Compact size for installation •Real-time data collection and
in locations with limited space display on SCADA software SCADA
•PoE solution to reduce power •Local data logging and files
supply and wiring cost uploaded on schedule
EDS-G205A-4PoE •SNMP trap alert for
PoE unmanaged
Ethernet switch
critical events
MX-AOPC UA Server
ioLogik P1242 Inverter
PoE Remote I/O
11 www.moxa.com/Smart_IO 12
Smart Transportation Smart City
Electronic Toll Collection System Background and Background and Remote Monitoring of a Water Distribution Network
Smart I/O for data collection in critical conditions Requirements Requirements Wireless I/O for data collection from unmanned sites
Reliable data collection in Remote Water Pumping
harsh environments Station
Customer needs: Customer Needs:
•Front-end control logic •Cellular communication for et
ern
Deduction EDS-G308-T •Snapshots of non-compliant remote site deployment Eth
e-Tag Reader Antenna Unmanaged Ethernet Switch vehicles triggered •Easy to integrate SCADA with MX-AOPC
automatically cellular communication UA Server
•Active alarms for unexpected
events
r
Sensor IP Camera lula
Cel work
Net
ioLogik E2212
Smart Remote I/O ioLogik E1240
Remote I/O
Railway Onboard Condition Monitoring Background and Background and Airport Perimeter Security Monitoring System
Requirements Requirements
Robust I/O for train data collection Intrusion detection and alarm system with local intelligence
Upgrade existing trains for IIoT Ensure Airport Security
Customer needs: Customer Needs:
•Installation in limited space •Intrusion event-driven alarm
•Legacy 2-wire network messages
infrastructure connection •Integration with surveillance
•Multiple IOs and serial system
interfaces are required •Low bandwidth required
•Compliance with railway •Local control capability
certifications
Serial
I/O Signal Cont
rol R
Ethernet oom I/O Signal
2-Wire Ethernet Ethernet
13 www.moxa.com/Smart_IO 14
Programmable Controllers Smart Remote I/O with Click&Go Plus Logic
Smart Ethernet Remote I/O with Click&Go Logic Ethernet Remote I/O
ioLogik E2210 ioLogik E2212 ioLogik E2214 ioLogik E2240 ioLogik E2242 ioLogik E2260 ioLogik E2262 ioLogik E1210 ioLogik E1211 ioLogik E1212 ioLogik E1214 ioLogik E1213** ioLogik E1240 ioLogik E1241 ioLogik E1242 ioLogik E1260 ioLogik E1262
Inputs/Outputs Inputs/Outputs
Digital Inputs 12 8 6 – – – – Digital Inputs 16 – 8 6 8 – – 4 – –
Digital Outputs 8 8 – – – 4 4 Digital Outputs – 16 – – 4 – – – – –
Relays – – 6 – – – – Relays – – – 6 – – – – – –
Configurable DIOs – 4 – – 12 – – Configurable DIOs – – 8 – 4 – – 4 – –
Analog Inputs – – – 8 4 – – Analog Inputs – – – – – 8 – 4 – –
Analog Outputs – – – 2 – – – Analog Outputs – – – – – – 4 – – –
RTDs – – – – – 6 – RTDs – – – – – – – – 6 –
Thermocouples – – – – – – 8 Thermocouples – – – – – – – – – 8
Ethernet Ethernet
Ports (Connector) 1 (RJ45) Ports (Connector) 2 (RJ45)
Speed 10/100 Mbps Speed 10/100 Mbps
Protocols Modbus/TCP (slave), TCP/IP, UDP, DHCP, BOOTP, SNMP, HTTP, CGI, SNTP, SMTP Switch (Daisy Chain)
Serial Protocols Modbus/TCP (Slave), EtherNet/IP*, SNMPv1/v2c, RESTful API, TCP/IP, UDP, DHCP, BOOTP, HTTP
Ports (Connector) 1 x RS-485 (Euroblock terminal) Environmental Limits
Interface RS-485 Standard Operating Temp. -10 to 60°C (14 to 140°F)
Protocols Modbus/RTU (gateway) Wide Operating Temp. -40 to 75°C (-40 to 167°F)
Environmental Limits Storage Temp. -40 to 85°C (-40 to 185°F)
Standard Operating Temp. -10 to 60°C (14 to 140°F) Operating Humidity 5 to 95% RH (non-condensing)
Wide Operating Temp. -40 to 75°C (-40 to 167°F) Standards and Certifications
Storage Temp. -40 to 85°C (-40 to 185°F) Safety UL 508
Ambient Relative Humidity 5 to 95% RH (non-condensing) EMC EN 55032; EN 55024; EN 61000-6-2; EN 61000-6-4
Standards and Certifications EMI CISPR 32, FCC Part 15B Class A
Safety UL 508 EMS EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8
EMC EN 61000-6-2; EN 61000-6-4 Hazardous Location Class I Division 2, ATEX Zone 2
EMI CISPR 22, FCC Part 15B Class A
*Requires online registration at http://license.moxa.com/ (available free of charge)
EMS EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8 **The ioLogik E1213 uses source-type DOs
15 www.moxa.com/Smart_IO 16
Ethernet Remote I/O – 3 Phase AC Meter (Available in Q4, 2017) RS-485 Remote I/O
ioLogik E1230EM ioLogik R1210 ioLogik R1212 ioLogik R1214 ioLogik R1240 ioLogik R1241
Input/Output Input/Output
Current Inputs 4 Digital Inputs 16 8 6 – –
Voltage Inputs 3 Relay Outputs – – 6 – –
Ethernet Configurable DIOs – 8 – – –
Ports (Connector) 2 (RJ45) Analog Inputs – – – 8 –
Speed 10/100 Mbps Analog Outputs – – – – 4
Switch (Daisy Chain) Serial
Protocols Modbus/TCP (Slave), SNMPv1/v2c/v3, TCP/IP, UDP, DHCP, BOOTP, HTTP Ports (Connector) 2 (5-wire Euroblock terminal)
Environmental Limits Interface Dual RS-485
Standard Operating Temp. -10 to 60°C (14 to 140°F) Protocols Modbus/RTU (slave)
Wide Operating Temp. -40 to 75°C (-40 to 167°F) Environmental Limits
Storage Temp. -40 to 85°C (-40 to 185°F) Standard Operating Temp. -10 to 75°C (14 to 167°F)
Operating Humidity 5 to 95% RH (non-condensing) Wide Operating Temp. -40 to 85°C (-40 to 185°F)
Standards and Certifications Storage Temp. -40 to 85°C (-40 to 185°F)
Safety UL 61010 Operating Humidity 5 to 95% RH (non-condensing)
EMC EN 55032; EN 55024; EN 61000-3-2/3-3; EN 61000-6-2/6-4 Standards and Certifications
EMI CISPR 32, FCC Part 15B Class A Safety UL 508
EMS EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8 EMC EN 55032; EN 55024
EMI CISPR 32, FCC Part 15B Class A
EMS EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6; EN 61000-4-8
PoE Remote I/O with Power Daisy Chain (Available in Q4, 2017) Ethernet Remote I/O
ioLogik P1210 ioLogik P1212 ioLogik P1214 ioLogik P1242 ioLogik E1261W-T ioLogik E1263H-T ioLogik E1261H-T ioLogik E1510-M12-T ioLogik E1512-M12-T
Input/Output Input/Output
Digital Inputs 16 8 6 4 Digital Inputs – – – 12 4
Digital Outputs – 8 – – Configurable DIOs 12 24 12 – 4
Configurable DIOs – – – 4 Analog Inputs 5 10 5 – –
Relays – – 6 – RTDs 3 3 3 – –
Analog Inputs – – – 4 Ethernet
Power Output Channel 1 1 1 1 Ports (Connector) 1 (RJ45) 2 (RJ45) 1 (M12)
Ethernet Speed 10/100 Mbps
Ports (Connector) 2 (RJ45) Switch (Daisy Chain) – – –
Speed 10/100 Mbps Protocols Modbus/TCP (slave), TCP/IP, UDP, DHCP, BOOTP, HTTP
Power Daisy Chain* Environmental Limits
Protocols Modbus/TCP (Slave), TCP/IP, UDP, DHCP, Bootp, SNMP(v1/v2c/v3), SNMP Trap (v1/v2c), HTTP, HTTPS, CGI, RESTful API, SNTP Operating Temp. -40 to 75°C (-40 to 167°F) -40 to 85°C (-40 to 185°F)
Power-over-Ethernet (PoE) Ethernet port L1: 802.3 AF/AT; mode A/B as Powered Device (PD) Storage Temp. -40 to 85°C (-40 to 185°F)
Environmental Limits Operating Humidity 5 to 95% RH (non-condensing)
Standard Models -10 to 60°C (14 to 140°F) Standards and Certifications
Wide Temp. Models -40 to 75°C (-40 to 167°F) Safety UL 508
Storage Temp. -40 to 85°C (-40 to 185°F) EMC EN 55032; EN 55024 EN 61000-6-2/6-4
Operating Humidity 5 to 95% RH (non-condensing) EMI CISPR 32, FCC Part 15B Class A
Standards and Certifications EMS EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6; EN 61000-4-8
Safety UL 61010 Rail Traffic – – – EN 50155*, EN 50121-4
EMC EN 55032; EN 55024; EN 61000-6-2/6-4 Marine Communications – IEC 60945 – –
EMI CISPR 32, FCC Part 15B Class A
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For more information, please download the product datasheet from Moxa's website.
EMS EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8
Power Output Channel
Output Voltage 12/24 VDC
Current Rating 100 mA @ 12 VDC / 50 mA @ 24 VDC
*The ioLogik P1200 series Power Daisy Chain DOES NOT provide power as a PSE. The cascaded PD must connect to Ethernet port L2 and support DC direct input over Mode A/B.
17 www.moxa.com/Smart_IO 18