By359 1500
By359 1500
By359 1500
LIMITING VALUES
Limiting values in accordance with the Absolute Maximum System (IEC 134).
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
VRSM Peak non-repetitive reverse - 1500 V
voltage
VRRM Peak repetitive reverse voltage - 1500 V
VRWM Crest working reverse voltage - 1300 V
IF(peak) Peak forward current 16-32kHz TV BY359-1500 - 10 A
31-70kHz monitor BY359-1500S - 7 A
IF(RMS) RMS forward current - 15.7 A
IFRM Peak repetitive forward current sinusoidal; a = 1.57 - 60 A
IFSM Peak non-repetitive forward t = 10 ms - 60 A
current t = 8.3 ms - 66 A
sinusoidal; Tj = 150 ˚C prior to surge;
with reapplied VRWM(max)
Tstg Storage temperature -40 150 ˚C
Tj Operating junction temperature - 150 ˚C
THERMAL RESISTANCES
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
Rth j-mb Thermal resistance junction to - - 2.0 K/W
mounting base
Rth j-a Thermal resistance junction to in free air. - 60 - K/W
ambient
STATIC CHARACTERISTICS
Tj = 25 ˚C unless otherwise stated
BY359-1500 BY359-1500S
SYMBOL PARAMETER CONDITIONS TYP. MAX. TYP. MAX. UNIT
VF Forward voltage IF = 20 A 1.3 1.8 1.5 2.0 V
IF = 10 A; Tj = 150˚C 1.00 1.5 1.25 1.75 V
IR Reverse current VR = 1300 V 10 100 10 100 µA
VR = 1300 V; 50 300 100 600 µA
Tj = 100 ˚C
DYNAMIC CHARACTERISTICS
Tj = 25 ˚C unless otherwise stated
BY359-1500 BY359-1500S
SYMBOL PARAMETER CONDITIONS TYP. MAX. TYP. MAX. UNIT
trr Reverse recovery time IF = 2 A; VR ≥ 30 V; 0.47 0.60 0.28 0.35 µs
Qs Reverse recovery charge -dIF/dt = 20 A/µs 1.6 2.0 0.70 0.95 µC
Vfr Peak forward recovery voltage IF = 10 A; 11.0 - 17.0 - V
dIF/dt = 30 A/µs
dI I
I F F
F
dt
trr
time time
VF
Qs 100%
25%
V
fr
I
R I VF
rrm
time
Fig.1. Definition of trr, Qs and Irrm Fig.2. Definition of Vfr
40
30
10 typ
20
10 max
0 0
1ms 10ms 0.1s 1s 10s 0 1.0 2.0
tp / s VF / V
Fig.3. Maximum non-repetitive rms forward current. Fig.5. BY359-1500 forward characteristic IF = f(VF);
IF = f(tp); sinusoidal current waveform; Tj = 150˚C prior parameter Tj
to surge with reapplied VRWM.
Tj=25C
1
20
0.1
10 typ
0.01 PD tp tp
D=
T
max
t
T
0.001 0
1us 10us 100us 1ms 10ms 100ms 1s 10s
0 1.0 2.0
pulse width, tp (s) BY359 VF / V
Fig.4. Transient thermal impedance Zth = f(tp) Fig.6. BY359-1500S forward characteristic IF = f(VF);
parameter Tj
MECHANICAL DATA
Dimensions in mm
4,5
Net Mass: 2 g max
10,3
max
1,3
3,7
2,8 5,9
min
15,8
max
3,0 max
not tinned
3,0
13,5
min
1,3
max 1 2
(2x) 0,9 max (2x)
0,6
5,08 2,4
Notes
1. Refer to mounting instructions for TO220 envelopes.
2. Epoxy meets UL94 V0 at 1/8".
DEFINITIONS
Data sheet status
Objective specification This data sheet contains target or goal specifications for product development.
Preliminary specification This data sheet contains preliminary data; supplementary data may be published later.
Product specification This data sheet contains final product specifications.
Limiting values
Limiting values are given in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one
or more of the limiting values may cause permanent damage to the device. These are stress ratings only and
operation of the device at these or at any other conditions above those given in the Characteristics sections of
this specification is not implied. Exposure to limiting values for extended periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification.
Philips Electronics N.V. 1998
All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the
copyright owner.
The information presented in this document does not form part of any quotation or contract, it is believed to be
accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any
consequence of its use. Publication thereof does not convey nor imply any license under patent or other
industrial or intellectual property rights.