XDPIP036EN-I Expertise in Process Analytics Screen
XDPIP036EN-I Expertise in Process Analytics Screen
Process
Analytics
Process Sensors
Continuous
Measurement
Gives You
Maximum Control
SEVERAL SENSORS UNDER
Anton Paar’s process sensors ensure high product
ONE ROOF
quality, optimize your raw material consumption, and
maximize production capacity.
We offer the most effective
We are the one supplier for all of your needs: Whether solution or sensor combination
for density, sound velocity, or refractive index, we for your application with our
are the only company that can provide you with all broad sensor portfolio
three methods for the concentration measurement of
liquids. We are also the only company that can offer
measuring instruments for CO2, O2, N2, or N2O.
Ÿ Chemical
Ÿ Metal and Mining
Ÿ Pharma
GREAT PERFORMANCE,
Ÿ Semiconductors GREAT RESULTS
TAILORED SOLUTIONS
FIND OUT MORE
Ranging from process and 1 Contact our global sales 2 Develop an application 3 Use the right technology 4 Easily integrate our 5 Access your results
petroleum engineers to chemists and service team together for the right results sensors into your quickly and easily
and brewers, our specialized Whether you’re dealing We can provide you a Whether it’s for density, processes To get your measurement
with commonly used solution from our extensive sound velocity, or refractive The measuring principles results, choose from
team of experts leverages its
process liquids or new, application database or we’ll index, we have a wide range behind the sound velocity Pico 3000 (our smart
deep industry knowledge to tailored applications, we develop a concentration of sensor technologies on and refractive index sensors transmitter) or our powerful
develop tailored solutions for help you reliably measure formula with Anton Paar hand, which means we can are easy to install and mPDS 5 evaluation unit.
any application. In just five concentrations in your laboratory meters for your always provide the ideal reduce factory downtime. Alongside intuitive operation,
steps, we provide you with the process with high precision. sample, which helps us measurement technology for The density sensors are the wide range of fieldbus
Once you contact us, we pick a suitable and accurate your needs. We select the even optimized for easy communication options
comprehensive and professional
work with you towards a measurement system for sensors that give you highly installation with a modular means you can integrate
support you need to develop solution based on your you. precise measurement results adapter system. No matter both of these into your plant
applications and integrate our requirements. and meet your requirements. what you use, you’ll be able control system easily.
devices or complete systems to measure your process
into your plant. liquid reliably.
Access All Three Methods
with Anton Paar
The L-Dens inline density and concentration meters cover all Ÿ A wide range of pre-installed applications makes
them extremely versatile, even for small lab
your needs across a wide variety of applications in virtually
production setups and across various industries
all industries, including the chemical, beverage, petroleum,
Ÿ The wetted material – available in stainless steel
pharmaceutical, and ethanol industries.
or borosilicate glass – lets you measure both non-
corrosive and aggressive media
The L-Dens 3300 sensors are budget-friendly entry-level
models. The L-Dens 7000 series combines high accuracy
and a compact design, making it the number-one choice for
precise density and concentration measurements. Thanks to
the wide range of integration options, these instruments can
be easily integrated into your plant.
With our durable L-Rix 4100/5100/5200 inline refractometers, With a 35-year development history, the compact sound
conduct real-time concentration measurements and get velocity sensor L-Sonic 5100/6100 delivers a repeatability of
production control of raw, intermediate, and final products. The up to 0.005 m/s.
sensors continuously measure concentration at the process
temperature, giving you 24-hour production control. The built-in The sensors are designed for concentration measurement,
evaluation unit has a modern touchscreen. With the Pico 3000 phase detection, product identification and quality control in
software or the mPDS 5 evaluation unit, you don’t need any the chemistry, petroleum, mining and steel industries, as well
special training to set up and use the instrument – just follow as for HVAC and brewery businesses – and much more.
the directions on the interface.
12
Oxy L-Col
Dissolved Oxygen in Real Time Inline Color Measurement
With real-time results, the Oxy 4100 transmitter and L-Col 6100 detects the amount of absorbed
Oxy 5100 sensor measure dissolved oxygen directly in the light and assesses the product color to ensure it
production line, independent of the solution medium and complies with standards such as EBC/MEBAK®/
other dissolved gases. They’re both SIP-ready, and Oxy 5100 ASBC for beer color at 430 nm. Leverage tailored
is also EHEDG-certified. wavelength configurations to compensate for
turbidity. With L-Col 6100, follow your entire
production process, detect the maturity level of
your beverage during storage, control the dosing of
Oxy series: Inline oxygen sensor
additives, and manage your blending process.
Ÿ Clever sensor caps covering your complete
liquid range portfolio: from trace range up to
wide and ultra-wide range
Ÿ EBC/MEBAK®/ASCB compliant
Measuring range 500 kg/m³ to 2,000 kg/m³ 500 kg/m³ to 2,000 kg/m³ 500 kg/m³ to 2,000 kg/m³ Measuring range Max. 1,500 kg/m³ Max. 3,000 kg/m³ Max. 2,000 kg/m³ Max. 2,000 kg/m³
800 m/s to 2,000 m/s
Accuracy in adjusted range 1 kg/m³ 1 kg/m³ 1 kg/m³
Accuracy in adjusted 0.5 kg/m³ 0.1 kg/m³ 0.05 kg/m³ 0.05 kg/m³
Process temperature -10 °C to +60 °C SST: 10 °C to 80 °C SST: 10 °C to 80 °C range Tantalum 0.5 kg/m³ Repeatability sound
SST E: -10 °C to +60 °C GLS: -10 °C to +60 °C velocity: 0.01 m/s
CIP/SIP temperature and SST: 95 °C for 30 min SST: 95 °C for 30 min Process temperature -40 °C to +125 °C -25 °C to +125 °C
duration non-Ex version
Ambient temperature -10 °C to +50 °C SST: -10 °C to +50 °C -10 °C to +40 °C CIP/SIP temperature and 145 °C for max. 30 min
SST E: -10 °C to +60 °C duration non-Ex version
Process pressure absolute Max. 6 bar Max. 16 bar SST: max. 16 bar Ambient temperature -40 °C to +70 °C -25 °C to +65 °C
GLS: max. 6 bar non-Ex version
Material of the wetted parts GLS: glass, PVDF, Kalrez SST: 1.4571, 1.4404 SST: 1.4571, 1.4404, PVDF, Process pressure Max. 50 bar Max. 50 bar Max. 50 bar Max. 50 bar
GLS FCM: glass, PAS-PVDF, EPDM SST E: 1.4571, 1.4404, FKM Viton absolute (HP version max. 180 bar)
GLS PP: glass, PVDF, Kalrez GLS: glass, PVDF, Kalrez
Material of the wetted 1.4404 1.4404, Alloy C-276, Alloy C-276 Alloy C-276
Communication RS-232 RS-232 Analog, RS-232, RS-485, Relay parts Incoloy 825, Tantalum
Process connections GLS: Flange plate & adapters Flange plate & adapters G 1/8" Communication Can be combined with Pico 3000, Pico 3000 RC, and mPDS 5
GLS FCM: Flange plate & adapters
GLS PP: G 1/8" Process connections Adapter for inline, bypass, and tank installation
Flange: DIN/EN, ANSI, JIS, Tri-Clamp, VARIVENT® N, G 3/8”, Tube OD 12 mm, or 1/4”
U-tube inner diameter 2.0 mm 2.1 mm SST: 2.1 mm
GLS: 2.1 mm U-tube inner diameter 6.3 mm
Recommended flow rate 10 L/h to 70 L/h 10 L/h to 80 L/h SST: 10 L/h to 80 L/h Recommended flow rate 100 L/h to 500 L/h
GLS: 10 L/h to 70 L/h
Degree of protection IP 66 / 67 / NEMA 4X
Degree of protection IP 65
Certificates CE, ATEX, IECEx, NRTL, INMETRO
Certificates CE
Dimensions Ex: 245 mm x 160 mm x 245 mm x 145 mm x 190 mm x 145 mm x 258 mm x 142 mm x
Dimensions GLS: 88 mm x 38 mm x 48 mm SST: 99 mm x 34 mm x 38 mm 166 mm x 155 mm x 91 mm 205 mm 185 mm 185 mm 192 mm
GLS FCM: 88 mm x 38 mm x 48 mm SST E: 134 mm x 64 mm x 64 mm (Ex: 245 mm x 160 mm x (Ex: 190 mm x 160 mm x (Ex: 258 mm x 156 mm x
GLS PP: 126 mm x 56 mm x 46 mm 205 mm) 205 mm) 214 mm)
Standard adjustment range 500 kg/m³ to 2,000 kg/m³ 500 kg/m³ to 2,000 kg/m³ 500 kg/m³ to 2,000 kg/m³ Standard adjustment 600 kg/m³ to 1,200 kg/m³ 700 kg/m³ to 1,200 kg/m3
range 800 m/s to 2,000 m/s
Weight GLS, gLS FCM: 105 g SST: 105 g 1800 g
GLS PP: 275 g SST E: 400 g Weight 4.5 kg 4.8 kg 4.5 kg 5.3 kg
L-Sonic 5100 L-Sonic 6100 Oxy 4100 / Oxy 5100
Measuring range 800 m/s to 2,500 m/s 200 m/s to 1,560 m/s Sensor cap Ultra-trace range* Trace range Wide range Ultra-wide range*
Repeatability* 0.005 m/s 0.01 m/s Measuring range - 0 ppb to 2,000 ppb 0 ppm to 22.5 ppm 0 ppm to 45 ppm
(dissolved O2 in liquids) (Gas phase only)
Process temperature non-Ex -25 °C to +125 °C
version Measuring range (gas 0 ppmv to 200 ppmv 0 % O2 to 4.2 % O2 0 % O2 to 50 % O2 0 % to 100 % O2
phase O2 in CO2) (0 to 0.2 hPa) (0 to 40 hPa) (0 to 500 hPa) (0 to 1,000 hPa)
CIP/SIP temperature and duration 145 °C for max. 30 min
Accuracy for liquids (the - ≤±1 % ppb or ± 3% ≤±0.042 ppm or ±3% ≤±0.1 ppm or ±5%
Ambient temperature -25 °C to +65 °C without HMI larger value is valid) (Gas phase only)
-20 °C to +55 °C with HMI
Process temperature 0 °C to 40 °C -5 °C to +65 °C (Oxy 5100) -5 °C to +40 °C
Process pressure absolute According to flange specification Up to 70 bar @ 125 °C or -5 °C to +40 °C (Oxy 4100)
100 bar @ 50 °C
CIP/SIP temperature and Not suitable for CIP/SIP Max. 99 °C,
Material of the wetted parts Stainless steel 1.4404 (316L), Stainless steel 1.4404 (316L) duration max. 130 °C (max. 30 min)
Hastelloy®, Monel 400
24 k gold-coated, rhodium-coated Ambient temperature -5 °C to +50 °C
Communication Can be combined with Pico 3000, Pico 3000 RC and mPDS 5 Process pressure absolute 12 bar, max. 5 bar for measurements in gas phase
Process connections VARIVENT® N, VARIVENT® G Tube end: OD 12 mm Material of the wetted Stainless steel 1.4404 (AISI 316L)
DIN 11851 Compression type fitting (12mm, 1/2") parts
EN 1092-1, ANSI B16.5 Compression type fitting w. external thread
(NPT 3/4", G 3/4") Material of the wetted Sensor cap: Stainless steel 1.4404 (AISI 316L)
parts sensor cap Sensor spot coating: Silicone (FDA approved)
Fork length 56 mm, 125 mm (standard) - O-Ring: FKM 75.16-04 (FDA approved)
or customer-specific
Communication Pico 3000, Pico 3000 RC*, mPDS 5*
Recommended flow rate 0.1 m/s to 6 m/s 50 L/h to 700 L/h
Process connections Tuchenhagen VARIVENT® Type N
Degree of protection IP 66 / 67 / NEMA 4X
Degree of protection IP65; IP67
Certificates CE, ATEX, IECEx, NRTL, INMETRO
Certificates CE, EHEDG* (Type EL - Class I)
Dimensions Depending on model Non Ex: 150 mm x 145 mm x 175 mm
Ex version: 160 mm x 160 mm x 190 mm Dimensions 162 x 162 x 215 mm
*Is a measure for the variations in measurement taken by a single L-Sonic 5100/6100 instrument *Not available for Oxy 4100
L-Rix 4100 L-Rix 5100 L-Rix 5200 Carbo 5100 Carbo 6100 Carbo 6300
Measuring range 1.3100 to 1.4910 1.3100 to 1.5400 1.3100 to 1.4600 Measuring range 0 g/L to 20 g/L (0 vol to 10 vol) 0 g/L to 12 g/L (0 vol to 6 vol)
(equivalent to 0 % to 80 % mass) (equivalent to 0 % to 100 % mass) (equivalent to 0 % to 65 % mass)
Accuracy 0.05 g/L (0.025 vol)
Accuracy nD ±0.0002 nD ±0.0002 nD ±0.0001
(equivalent to ±0.1 % mass) (equivalent to ±0.1 % mass) (equivalent to ±0.05 % mass) Process temperature - 5 °C to +40 °C - 3 °C to +40 °C
Process temperature 0 °C to 100 °C -20 °C to +120 °C 0 °C to 105 °C CIP/SIP temperature and Up to 121 °C for 30 minutes Up to 95 °C for 4 h Up to 95 °C for 4 h or up to
duration 130 °C for 30 min
CIP/SIP temperature and Up to 145 °C for 30 minutes
duration Ambient temperature 0 °C to 50 °C -20 °C to +50 °C
Process pressure absolute 100 mbar to 10 bar 100 mbar to 16 bar (10 bar @ >120 °C) Material of the wetted parts WC, SSiC, Stainless steel 1.4404 (AISI 316L), PEEK, Sapphire (Al2O3 – 99.997%),
Stainless steel 1.4404 (AISI 316L) O-ring: VARIVENT® connection - EPDM 70.10-02 (FDA approved)
Material of the wetted parts Stainless steel 1.4404 (AISI 316L), PEEK, Sapphire (Al2O3 – 99.997%), O-ring: VARIVENT® connection - EPDM O-Rings, diaphragms: EPDM
70.10-02 (FDA approved) 70.10-02 (FDA-approved)
Communication Pico 3000 - Analog Pico 3000, Pico 3000 RC, mPDS 5 Communication Pico 3000, Pico 3000 RC, mPDS 5
Process connections Tuchenhagen VARIVENT® Type N Tuchenhagen VARIVENT® Type N, Tri-Clamp® 3‘‘ Process connections Tuchenhagen VARIVENT® Type N
Certificates CE, EHEDG (Type EL - Class I) Certificates CE CE, EHEDG (Type EL - Class I)
Light source LED 589 nm Dimensions 173 mm x 224 mm x 219 mm 142 mm x 142 mm x 220 mm
Sensor input L-Dens, L-Com, L-Sonic, L-Rix, Oxy, Carbo, L-Col, DPR(n), SPR(n), DSR(n), Sensor input L-Dens, L-Com, L-Sonic, L-Rix, Oxy, Carbo
and third-party sensors via analog input
Communication interfaces Analog/Digital, Frequency, HART, Modbus RTU, PROFIBUS DO, PROFINET IO, EtherNet/IP, Modbus TCP
Transducer board Transd. 1/Transd. 2: DPR(n), SPR(n), DSR(n)
only for old density/sound 2 analog inputs: 4 to 20 mA active/passive Mounting option Within sensor Wall, cabinet
velocity transducers 12 digital inputs/outputs or counter: e.g., filler stop, bottle
Housing material Stainless steel 1.4305 (AISI 303)
counter, limit alarms
Display 45 mm x 60 mm TFT display incl. 5 capacitive keys
Input/Output board 4 analog outputs: connection to PLC
3 analog inputs: 4 to 20 mA active/passive Degree of protection IP65; IP67
12 digital inputs/outputs or counter: e.g., filler stop, bottle
counter, product selector Certificates CE
2 relay outputs: alarms
Supply voltage DC 24 V (range DC 20 - 28.8 V)
FIeldbus boards PROFIBUS DP, PROFINET IO, EtherNet/IP, DeviceNet
Power consumption Max. 3 W
and Modbus TCP
Dimensions 142 mm x 142 mm 142 mm x 142 mm x 100 mm
Ambient temperature 5 °C to 40 °C
(wall mount length 240 mm)
Mounting option Control panel, switch cabinet
Reliable.
FIND OUT MORE
Inline Pump 300
Inline Pump 300 Ex d
Compliant.
Qualified.
Type Magnetically coupled centrifugal pump www.anton-paar.com/
service
Process temperature +5 °C to +100 °C +5 to +105 °C -25 °C to +80 °C (T4)
(+120 °C for max. 30 min.) (+145 °C for max. 30 min)
Viscosity max. 150 mPas 0.35 mPas to 10 mPas 0.35 mPas to 10 mPas
Our well-trained and certified technicians are ready
Ambient conditions -20 °C to +40 °C -5 °C to +60 °C -25 °C to +60 °C to keep your instrument running smoothly.
Power supply SELV DC 24 V powered by the sensor powered by the sensor
Wetted material 1.4404, SSiC, WC, EPDM 1.4404, SSiC, WC, EPDM 1.4404, SSiC, WC, EPDM or
FKM
24
Maximum uptime Warranty program Short response times A global service network
10 mm
©© 2024
2017 Anton
Anton Paar
Paar GmbH
GmbH | All rights reserved.
Specifications
Specifications subject
subject to change without notice.
document number
XDPIP036EN-I
10 mm
12 mm
www.anton-paar.com
12 mm