Excel Calculation
Excel Calculation
1
Pump Head mm m Description C Value
Input Data for pump selection GS 120
Collecting reservoir base elevation 1800 masl uPVC 130
Well head elevation 1750 masl DCI 130
Dynamic Water level 60 m HDPE 130
Recommended pump position 70 m
Recommended design discharge 5 0.005 l/s /(m3/s)
Reservoir
Data of Height
pipelines:from under ground upto m
reserviour
1 Riser pipe
Material: GS 110 C
Nominal diameter: 65 0.065 DN(mm)/m
Length: pp 70 m
Transmission Main:
2 From BH head to Collection Reservoir
Material: Gs 110 C
Nominal diameter: 80 0.08 DN/mm/m
Length: 1000 m
From BH head to Junction Point
Material:
Nominal diameter:
Length:
From Junction to Collecting Reservoir
Material: C
Nominal diameter: DN(mm)
Length: m
CALCULATOR
1. Dynamic Head, HD 0
Head Loss Calculation from BH to Reservoir
1.1 Riser pipe and head work pipe loss
( hrp),riser pipe DN65mm,L=70m, Q = 5 l/s
Hrp = 10.7 (Q/C)1.85 x L / (D)4.87
H riser pipe loss 4.1890139954
1.2Transmission Main Head Losses, head work
pipe loss ( hrp), DN 80, L=1000m,
headwork pipe length), Q = 5 l/s …(Assume
headwork pipe length)
Htp = 10.7 (Q/C)1.85 x L / (D)4.87
Bore Hole to Junction Point
Bore Hole to Reservoir, Hpressure pipe loss 21.769757008
Junction Point to Reservoir
Hrp + Htp 25.958771003
1.3 Minor Head Losses= 10%*(Hrp & Htp)
Hminor loss = 0.1*(Hrp +Htp) 2.5958771003
Htr = (Hrp + Htp)major + Hminor loss 28.554648104
HD 28.5546481
2. Static Head, HS
HS = Static Head = (Geo. Head+ Dynamic
Water Level) + Reservior Height
2.1 Geo. Head 50
2.2 Dynamic Water Level 60
2.3 Reservoir Height 5
HS 115
TOTAL PUMP HEAD, HT
HT = HD + HS 143.5546481
Take 145