Catalogue Final
Catalogue Final
Catalogue Final
Kirloskar Brothers Limited is a world-class pump manufacturing company with experience in engineering and
manufacture of systems for fluid management. Established in 1888 and incorporated in 1920, KBL is the flagship
company of the $2.1 billion Kirloskar Group. The market leader in fluid management, KBL provides complete fluid
management solutions for large infrastructure projects in the areas of water supply, power plants, irrigation, oil & gas
and marine & defence.
KBL’s commitment to quality and sustainability is as reliable as its products. This is why all plants of KBL are ISO 9001 &
ISO 14001, OHSAS 18001, ISO 14000 Environment Standard Certified. The plants apply Total Quality Management
tools using European foundation for Quality Management (EFQM) model.
As one of the largest pump manufacturers in India, KBL offers over 75 types of pumps in over 500 variants with up to
1,200 metre head and discharge of up to 120,000 cubic metres per hour. These pumps ensure the lowest life cycle cost;
it is because KBL pumps offer maximum reliability under all operating conditions, ensuring trouble-free operations at all
times and eliminating costly downtime. Additionally, KBL pumps are constructed with materials that offer the best
resistance to corrosion and abrasion, enhancing performance for years together.
Technological innovations employed in pump engineering also reduces overall energy use, enhancing efficiency and
cost saving.
1
2
INDUSTRIAL RANGE PUMPS
KDT
KS SRF
3
INDUSTRIAL RANGE PUMPS
KOSM KOS KV DV
4
INDUSTRIAL RANGE PUMPS
5
AGRICULTURE RANGE PUMPS
KDS DC
KAM
6
DOMESTIC RANGE PUMPS
Mini Series Self Priming Pumps - Ultra Series Mini Series Self Priming Pumps
7
DOMESTIC RANGE PUMPS
8
DOMESTIC RANGE PUMPS
Jet Pump Shallow Well Pumps Openwell Submersible Pumps - Single Phase
KOSi KOSi C
KJ
9
SUBMERSIBLE PUMPSETS
Borewell Submersible Pumps - Oil Cooled Borewell Submersible Pumps - Water Cooled
KP3S KU4 KP4 JALRAAJ UVA KU6i KS3 KS4 NEO KS6
Borewell Submersible Pumps - Water Cooled Openwell Submersible Pumps Vertical Openwell Pumps
10
OTHER PRODUCTS
End-Suction Pumps
NWD NW KE KH KHDT SR
11
CONTENT
JALTARA ...........................................................106
KAM ................................................................... 95
JALHANSA ........................................................ 106
DC / HASTI / PAMBA PUZHA.............................97
JALSENA ...........................................................106
DOMESTIC RANGE PUMPS
JALNAYAK ........................................................ 106
MINI SERIES SELF PRIMING PUMPS
AQUA KNIGHT................................................... 109
CHHOTU............................................................ 101
V FLOW ........................................................... 109
MINI 30C............................................................ 101 AQUA TORRENT-10FCL.................................... 109
13
CONTENT
K-BOOSTER....................................................... 129
KS3 ....................................................................150
STAR GALAXY.................................................... 131
KS4 ....................................................................152
HL PUMP
NEO ...................................................................158
HI - LIFTER......................................................... 133
14
CONTENT
KS9.....................................................................175 SR ......................................................................201
Note :
Information and declarations mentioned in this document or on nameplate are at standard test conditions and
as a part of continual improvements, specifications are subject to change without prior notice.
Images shown in the catalogue are for illustration purpose only. Actual product may vary. 15
16
INDUSTRIAL
PRODUCT RANGE
MONOBLOC PUMPS
THREE PHASE
17
TECHNICAL SPECIFICATION
Ultra Premium Efficiency
Head Range - Up to 54 Meters
Lower life cycle cost with lower operating cost.
Discharge Range - Up to 33 LPS
Power Rating - 1.1 - 3.7 kW (1.5 - 5.0 HP)
Higher Specific Discharge (discharge rate per unit power)
Voltage Range - 350 to 440 Volts
Up to 16.6 % less energy consumption for pumping same amount of fluid.
Insulation - F Class
KDI - EE5 High grade F-Class insulation with Temperature rise limited to B-Class
# Protection - IP55
Note:
n * KDI-318 EE5 can also be offered with pipe size 65 x 50.
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
19
TECHNICAL SPECIFICATION
Premium Efficiency IE4 Motor and Energy Saving Design
Head Range - Up to 80 Meters
Innovative design manufactured at state of art plant, delivers optimum efficiency at
lower energy consumption resulting in significant cost savings. Discharge Range - Up to 39 LPS
Power Rating - 1.5 to 15 kW (2 to 20 HP)
Superior Mechanical Seal Voltage Range - 350 to 440 Volts (Three Phase)
KDI - EE4 Superior quality of mechanical seal ensures zero leakage, lower friction loss,
protects from wearing of shaft, thus resulting in easy maintenance and longer life.
With Carbon Vs Ceramic mechanical seal and HNBR it can handle fluid up 120°C.
Insulation
Protection
-
-
F Class
IP55
20
PERFORMANCE CHART FOR KDI EE4 SERIES, 2 POLE, MONOBLOC PUMP, AT RATED VOLTAGE,
50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Rated TOTAL HEAD IN METRES
Power Rating Pipe Size (mm)
S. No. PUMP MODEL Voltage 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
kW HP SUC. DEL. (Volts) DISCHARGE IN LITRES PER SECOND
1 KDI - 216 EE4 1.5 2.0 65 50 415 - 11.0 10.0 8.7 7.0 4.0 - - - - - - - - - - - -
2 KDI - 225 EE4 1.5 2.0 50 40 415 - 5.4 5.2 5.0 4.7 4.5 4.1 3.7 3.2 2.7 - - - - - - - -
3 KDI - 235 EE4 1.5 2.0 50 40 415 - - 4.1 4.0 3.9 3.7 3.5 3.4 3.2 3.0 2.7 2.4 2.0 1.3 - - - -
4 KDI - 314 EE4 2.2 3.0 80 80 415 19.2 17.9 16.2 14.0 10.5 - - - - - - - - - - - - -
5 KDI - 318 EE4 2.2 3.0 80 65 415 - 13.4 12.6 11.7 10.7 9.2 7.5 4.5 - - - - - - - - - -
6 KDI - 318 EE4 2.2 3.0 65 50 415 - 13.4 12.6 11.7 10.7 9.2 7.5 4.5 - - - - - - - - - -
7 KDI - 335 EE4 2.2 3.0 50 40 415 - - - 5.05 4.9 4.8 4.6 4.5 4.35 4.2 4.0 3.8 3.5 3.2 2.7 2.0 - -
8 KDI - 515 EE4 3.7 5.0 100 100 415 33.0 30.5 28.0 24.0 19.0 12.0 - - - - - - - - - - - -
9 KDI - 520 EE4 3.7 5.0 80 80 415 - 23.4 22.0 20.8 19.5 18.0 16.0 13.2 10.0 - - - - - - - - -
10 KDI - 527 EE4 3.7 5.0 80 65 415 - - 16.0 15.4 14.8 14.2 13.4 12.5 11.4 10.0 8.3 5.8 - - - - - -
11 KDI - 538 EE4 3.7 5.0 65 50 415 9.0 8.90 8.85 8.8 8.7 8.6 8.55 8.45 8.35 8.25 8.1 7.9 7.6 7.1 6.6 6.0 5.1 4.0
12 KDI - 822 EE4 5.5 7.5 100 100 415 29.4 28.1 26.7 25.4 23.9 22.1 20.0 17.7 14.0 - - - - - - - -
13 KDI - 830 EE4 5.5 7.5 80 65 415 - - - - - 19.0 18.2 17.3 16.4 15.4 14.2 12.7 11.1 - - - - -
14 KDI - 837 EE4 5.5 7.5 65 65 415 - - - - - - - - 11.2 11.1 11.0 11.0 10.9 10.6 10.0 9.0 7.0 -
15 KDI - 1030 EE4 7.5 10.0 100 100 415 - - - 32.0 30.5 29.4 28.2 26.9 25.2 23.5 21.0 18.0 13.5 - - - - -
16 KDI - 1040 EE4 7.5 10.0 80 65 415 - - 23.5 23.0 22.5 22.0 21.5 20.9 20.3 19.5 18.7 17.9 17.0 15.8 14.6 13.3 11.0 9.0
17 KDI - 1331 EE4 9.3 12.5 100 100 415 - - 37.5 36.5 35.5 34.5 33.4 32.0 30.5 28.5 26.5 23.8 19.8 12.0 - - - -
18 KDI - 1537 EE4 11.0 15.0 100 100 415 - - 39.0 38.5 38.0 37.2 36.5 35.5 34.5 33.0 31.6 30.0 27.8 25.0 22.0 17.5 - -
22 24 26 28 30 32 34 36 38 40 44 46 48 52 56 60 64 68
19 KDI - 550 EE4 3.7 5.0 50 40 415 - - - - - - - - 5.0 4.8 4.1 3.7 3.2 1.6 - - - -
20 KDI - 844 EE4 5.5 7.5 65 65 415 11.5 11.3 11.0 10.6 10.2 9.7 9.0 8.4 7.7 7.0 4.2 - - - - - - -
21 KDI - 1050 EE4 7.5 10.0 65 65 415 - - 12.7 12.5 12.2 12.0 11.7 11.4 11.0 10.7 9.6 8.9 8.1 6.0 - - - -
22 KDI - 1065 EE4 7.5 10.0 65 50 415 - - - - - - - - - 7.8 7.3 7.1 6.9 6.4 5.8 5.1 4.3 3.0
14 16 20 22 24 28 30 32 34 36 38 40 42 44 46 48 52 54
23 KDI - 1348 EE4 9.3 12.5 80 65 415 - - 19.5 19.2 18.8 18.1 17.6 17.2 16.6 15.9 15.1 14.3 13.2 11.9 10.2 6.5 - -
24 KDI - 1555 EE4 11.0 15.0 80 65 415 - - - 19.75 19.7 19.5 19.4 19.2 18.8 18.5 18.0 17.4 16.7 16.0 15.0 14.2 12.2 10.5
25 KDI - 2050 EE4 15.0 20.0 100 80 415 35.0 34.2 33.0 32.2 31.7 30.1 29.5 28.8 28.0 27.0 26.0 25.0 24.0 22.5 21.0 19.4 13.5 -
18 22 28 30 34 36 40 44 46 48 52 56 60 64 68 72 76 80
26 KDI - 1360 EE4 9.3 12.5 65 50 415 12.9 12.7 12.4 12.3 12.0 11.7 11.3 10.7 10.4 10.0 9.1 8.3 7.0 4.5 - - - -
27 KDI - 1570 EE4 11.0 15.0 65 50 415 - - 13.2 13.1 12.9 12.8 12.5 12.0 11.8 11.5 10.7 10.0 9.0 8.0 6.5 - - -
28 KDI - 1575 EE4 11.0 15.0 65 50 415 - - - - - - - - - - - 7.7 7.3 6.9 6.4 5.8 4.9 3.4
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
21
TECHNICAL SPECIFICATION
High Efficiency IE2 Motor and Energy Saving Design
Innovative design manufactured at state of art plant, delivers optimum efficiency at Head Range - Up to 68 Meters
lower energy consumption resulting in significant cost savings. Discharge Range - Up to 33 LPS
Power Rating - 1.5 to 7.5 kW(2 to 10 HP)
Superior Mechanical Seal Voltage Range - 350 to 440 Volts(Three Phase)
Superior quality of mechanical seal ensures zero leakage, lower friction loss,
Insulation - F Class
KDI - EE2 protects from wearing of shaft, thus resulting in easy maintenance and longer life.
With Carbon Vs Ceramic mechanical seal and HNBR it can handle fluid up to Protection - IP55
120°C.
ENERGY EFFICIENT MONOBLOC MATERIAL OF CONSTRUCTION
PUMP WITH IE2 MOTOR EFFICIENCY Cathodic Electro Deposition (CED) Coating
CED is the latest coating technology for corrosion resistance with uniform coating,
provides 5 times more protection over conventional painting, resulting in longer Impeller - Cast Iron
life. All Hydraulic parts of Kirloskar pumps are CED coated. Delivery Casing - Cast Iron
Motor Body - Cast Iron
Dynamically Balanced Rotating Parts Pump Shaft - Stainless Steel
Seal with HNBR which can Minimum vibration protects the components from damage during the operation,
Sealing - Mechanical Seal
Handle uid up to 120°C thus ensuring consistent performance as concentricity is maintained.
(Carbon vs Ceramic with HNBR which can withstand fluid temperature up to 120°C)
22
PERFORMANCE CHART FOR KDI EE2 SERIES, 2 POLE, MONOBLOC PUMP, AT RATED VOLTAGE,
50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
23
FEATURES TECHNICAL SPECIFICATION
Flatter Efficiency Curve Head Range - Up to 80 Metres
Minimum variations in efficiency during entire operating range increases the utility of Discharge Range - Up to 39 LPS
pumpset for variable conditions.
Power Rating - 1.5 to 22 kW (2 to 30 HP)
Voltage Range - 350 to 440 Volts (Three Phase)
Wide Voltage Design
KDI The motor is designed to withstand wide voltage Variation from 350 to 440 volts and
reduces motor burning in case of low/high voltage.
Insulation
Protection
-
-
F Class
IP55
Mechanical Seal
Superior quality of mechanical seal ensures zero leakage, lower friction loss, protects
from wearing of shaft, thus resulting in easy maintenance and longer life.
24
PERFORMANCE CHART FOR KDI SERIES, 2 POLE, MONOBLOC PUMP, AT RATED VOLTAGE,
50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Rated TOTAL HEAD IN METRES
Power Rating Pipe Size (mm)
S. No. PUMP MODEL Voltage 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44
kW HP SUC. DEL. (Volts) DISCHARGE IN LITRES PER SECOND
1 KDI - 216+ 1.5 2.0 65 50 415 - 11.0 10.1 8.8 7.1 4.0 - - - - - - - - - - - - - -
2 KDI - 225++ 1.5 2.0 50 40 415 - 5.3 5.1 4.9 4.7 4.5 4.2 3.9 3.5 3.1 2.3 - - - - - - - - -
3 KDI - 235+ 1.5 2.0 50 40 415 - - 4.1 4.0 3.9 3.7 3.5 3.4 3.2 3.0 2.7 2.4 2.0 1.3 - - - - - -
4 KDI - 314+ 2.2 3.0 80 80 415 19.2 17.9 16.2 14.0 10.5 - - - - - - - - - - - - - - -
5 KDI - 318++ 2.2 3.0 80 65 415 - 13.4 12.6 11.7 10.7 9.2 7.5 4.5 - - - - - - - - - - - -
6 KDI - 318++ 2.2 3.0 65 50 415 - 13.4 12.6 11.7 10.7 9.2 7.5 4.5 - - - - - - - - - - - -
7 KDI - 325++ 2.2 3.0 65 50 415 - - 9.2 8.8 8.4 7.9 7.4 7.0 6.4 5.8 4.9 - - - - - - - - -
8 KDI - 335++ 2.2 3.0 50 40 415 - - - 5.05 4.9 4.8 4.6 4.5 4.35 4.2 4.0 3.8 3.5 3.2 2.7 2.0 - - - -
9 KDI - 515 3.7 5.0 100 100 415 33.0 30.5 28.0 24.0 19.0 12.0 - - - - - - - - - - - - - -
10 KDI - 520+ 3.7 5.0 80 80 415 - 23.0 22.0 20.8 19.5 17.9 16.0 14.0 11.0 - - - - - - - - - - -
11 KDI - 527++ 3.7 5.0 80 65 415 - - - - - 14.3 13.5 12.5 11.6 10.4 8.7 6.4 - - - - - - - -
12 KDI - 538+ 3.7 5.0 65 50 415 9.0 8.9 8.85 8.8 8.7 8.6 8.55 8.45 8.35 8.25 8.1 7.9 7.6 7.1 6.6 6.0 5.1 4.0 - -
13 KDI - 822++ 5.5 7.5 100 100 415 - - - 27.3 25.6 24.0 22.1 20.0 17.5 14.5 - - - - - - - - - -
14 KDI - 830++ 5.5 7.5 80 65 415 - - - - - 19.0 18.2 17.3 16.4 15.3 14.2 12.7 11.1 - - - - - - -
15 KDI - 837+ 5.5 7.5 65 65 415 - - - - - - - - 12.75 12.6 12.5 12.2 11.8 11.1 10.3 9.0 7.3 - - -
16 KDI - 844++ 5.5 7.5 65 65 415 - - - - - - - - - - 10.6 10.2 9.9 9.5 9.0 8.4 7.8 7.0 6.1 4.7
17 KDI - 1030+ 7.5 10 100 100 415 - - 32.0 31.0 29.7 28.3 27.0 25.2 23.5 21.0 18.0 13.5 - - - - - - -
18 KDI - 1040+ 7.5 10 80 65 415 - - 23.5 23.0 22.6 22.2 21.5 20.9 20.3 19.5 18.7 17.9 17.0 15.8 14.6 13.4 12.0 9.6 - -
19 KDI - 1331+ 9.3 12.5 100 100 415 - - 37.5 36.5 35.5 34.5 33.4 32.0 30.5 28.5 26.5 23.8 19.8 12.0 - - - - - -
20 KDI - 1537+ 11.0 15 100 100 415 - - 39.0 38.5 38.0 37.2 36.5 35.5 34.5 33.0 31.6 30.0 27.8 25.0 22.0 17.5 - - - -
14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 52 54
21 KDI - 550++ 3.7 5 50 40 415 - - - - - - - - - - - 4.1 3.9 3.7 3.5 3.3 3.0 2.7 2.0 -
22 KDI - 852++ 5.5 7.5 65 50 415 - - - - - - - - - 8.6 8.3 8.0 7.75 7.4 7.1 6.7 6.3 5.9 4.5 -
23 KDI - 1050+ 7.5 10 65 65 415 - - - - - - 12.7 12.5 12.2 12.0 11.7 11.4 11.0 10.7 10.2 9.6 8.9 8.1 6.0 -
24 KDI - 1348+ 9.3 12.5 80 65 415 - - - 19.5 19.2 18.8 18.5 18.1 17.6 17.2 16.6 15.9 15.1 14.3 13.2 11.9 10.2 6.5 - -
25 KDI - 1555+ 11.0 15 80 65 415 - - - - 19.75 19.7 19.6 19.5 19.4 19.2 18.8 18.5 18.0 17.4 16.7 16.0 15.0 14.2 12.2 10.5
26 KDI - 2050+ 15.0 20 100 80 415 35.0 34.2 33.8 33.0 32.2 31.7 30.8 30.1 29.5 28.8 28.0 27.0 26.0 25.0 24.0 22.5 21.0 19.4 13.5 -
18 22 26 28 30 32 34 36 40 44 46 48 52 56 60 64 68 72 76 80
27 KDI - 1065+ 7.5 10 65 50 415 - - - - - - - - 7.8 7.3 7.1 6.9 6.4 5.8 5.1 4.3 3.0 - - -
28 KDI - 1360+ 9.3 12.5 65 50 415 12.9 12.7 12.5 12.4 12.3 12.2 12.0 11.7 11.3 10.7 10.4 10.0 9.1 8.3 7.0 4.5 - - - -
29 KDI - 1570+ 11.0 15 65 50 415 - - - 13.2 13.1 13.0 12.9 12.8 12.5 12.0 11.8 11.5 10.7 10.0 9.0 8.0 6.5 - - -
30 KDI - 1575+ 11.0 15 65 50 415 - - - - - - - - - - - - 8.0 7.7 7.3 6.9 6.4 5.8 4.9 3.4
31 KDI - 2560+ 18.5 25 100 80 415 - - - - - - - - - 26.0 24.7 23.5 21.0 17.0 7.0 - - - - -
32 KDI - 3068+ 22.0 30 100 80 415 - - - - - - - - - - - 28.0 26.5 24.5 21.5 17.5 10.0 - - -
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
25
FEATURES TECHNICAL SPECIFICATION
26
PERFORMANCE CHART FOR 'KDS+/KDS++/GMC' SERIES, 2 POLE, MONOBLOC PUMP, AT RATED VOLTAGE,
50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Pipe Size Rated TOTAL HEAD IN METRES
Power Rating
S. No. PUMP MODEL (mm) Voltage 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44
kW HP SUC. DEL. (Volts) DISCHARGE IN LITRES PER SECOND
1 KDS - 0510+ 0.37 0.5 50 40 415 3.4 2.6 1.0 - - - - - - - - - - - - - - - - -
2 GMC - 112 0.75 1.0 50 50 415 6.5 5.4 4.0 2.0 - - - - - - - - - - - - - - - -
3 GMC - 116 0.75 1.0 50 40 415 5.4 5.0 4.6 4.2 3.6 3.0 1.9 - - - - - - - - - - - - -
4 GMC - 123 0.75 1.0 32 25 415 - - 4.1 3.6 3.2 2.7 2.2 1.7 0.9 - - - - - - - - - - -
5 GMC - 128 0.75 1.0 40 40 415 - - - 1.9 1.85 1.8 1.7 1.6 1.4 1.1 0.8 0.4 - - - - - - - -
6 GMC - 128 0.75 1.0 50 40 415 - - - 1.9 1.85 1.8 1.7 1.6 1.4 1.1 0.8 0.4 - - - - - - - -
7 GMC - 134 0.75 1.0 25 25 415 - - - - - 1.78 1.76 1.73 1.67 1.55 1.35 1.1 0.8 0.4 - - - - - -
8 GMC - 1.514 1.1 1.5 50 50 415 - 8.5 7.1 5.7 3.0 - - - - - - - - - - - - - - -
9 GMC - 1.522 1.1 1.5 50 40 415 - 6.3 5.9 5.5 5.0 4.5 3.9 3.1 1.8 - - - - - - - - - - -
10 GMC - 1.525 1.1 1.5 50 40 415 2.6 2.55 2.5 2.45 2.4 2.3 2.2 2.1 2.0 1.8 1.6 1.3 0.4 - - - - - - -
11 GMC - 1.540 1.1 1.5 32 25 415 - - - - - - - - 2.0 1.9 1.7 1.6 1.45 1.3 1.1 0.9 0.6 - - -
12 KDS - 212+ 1.5 2.0 80 80 415 14.1 12.4 10.5 7.5 - - - - - - - - - - - - - - - -
13 KDS - 216++ 1.5 2.0 65 50 415 - 11.0 10.1 8.8 7.1 4.0 - - - - - - - - - - - - - -
14 KDS - 225++ 1.5 2.0 50 40 415 - 5.3 5.1 4.9 4.7 4.5 4.2 3.9 3.5 3.1 2.3 - - - - - - - - -
15 KDS - 235+ 1.5 2.0 50 40 415 - - 4.1 4.0 3.9 3.7 3.5 3.4 3.2 3.0 2.7 2.4 2.0 1.3 - - - - - -
16 KDS - 314+ 2.2 3.0 80 80 415 19.2 17.9 16.2 14.0 10.5 - - - - - - - - - - - - - - -
17 KDS - 314+ 2.2 3.0 100 100 415 19.2 17.9 16.2 14.0 10.5 - - - - - - - - - - - - - - -
18 KDS - 318++ 2.2 3.0 80 65 415 - 13.4 12.6 11.7 10.7 9.2 7.5 4.5 - - - - - - - - - - - -
19 KDS - 318++ 2.2 3.0 65 50 415 - 13.4 12.6 11.7 10.7 9.2 7.5 4.5 - - - - - - - - - - - -
20 KDS - 325++ 2.2 3.0 65 50 415 - - 9.2 8.8 8.4 7.9 7.4 7.0 6.4 5.8 4.9 - - - - - - - - -
21 KDS - 335++ 2.2 3.0 50 40 415 - - - 5.05 4.9 4.8 4.6 4.5 4.35 4.2 4.0 3.8 3.5 3.2 2.7 2.0 - - - -
22 KDS - 515+ 3.7 5.0 100 100 400 33.0 30.5 28.0 24.0 19.0 12.0 - - - - - - - - - - - - - -
23 KDS - 520+ 3.7 5.0 80 80 400 - 23.0 22.0 20.8 19.5 17.9 16.0 14.0 11.0 - - - - - - - - - - -
24 KDS - 527++ 3.7 5.0 80 65 400 - - - - - 14.3 13.5 12.5 11.6 10.4 8.7 6.4 - - - - - - - -
25 KDS - 538+ 3.7 5.0 65 50 400 9.0 8.9 8.85 8.8 8.7 8.6 8.55 8.45 8.35 8.25 8.1 7.9 7.6 7.1 6.6 6.0 5.1 4.0 - -
26 KDS - 822++ 5.5 7.5 100 100 400 - - - 27.3 25.6 24.0 22.1 20.0 17.5 14.5 - - - - - - - - - -
27 KDS - 830++ 5.5 7.5 80 65 400 - - - - - 19.0 18.2 17.3 16.4 15.3 14.2 12.7 11.1 - - - - - - -
28 KDS - 837+ 5.5 7.5 65 65 400 - - - - - - - - 12.75 12.6 12.5 12.2 11.8 11.1 10.3 9.0 7.3 - - -
29 KDS - 844++ 5.5 7.5 65 65 400 - - - - - - - - - - 10.6 10.2 9.9 9.5 9.0 8.4 7.8 7.0 6.1 4.7
30 KDS - 1030+ 7.5 10.0 100 100 415 - - - 32.0 31.0 29.7 28.3 27.0 25.2 23.5 21.0 18.0 13.5 - - - - - - -
31 KDS - 1040+ 7.5 10.0 80 65 415 - - 23.5 23.0 22.6 22.2 21.5 20.9 20.3 19.5 18.7 17.9 17.0 15.8 14.6 13.4 12.0 9.6 - -
32 KDS - 1331+ 9.3 12.5 100 100 415 - - 37.5 36.5 35.5 34.5 33.4 32.0 30.5 28.5 26.5 23.8 19.8 12.0 - - - - - -
33 KDS - 1537+ 11.0 15.0 100 100 415 - - 39.0 38.5 38.0 37.2 36.5 35.5 34.5 33.0 31.6 30.0 27.8 25.0 22.0 17.5 - - - -
34 KDS - 2030+ 15.0 20.0 125 125 415 - - - - - 49.0 47.0 45.0 42.0 39.0 35.0 30.0 21.0 - - - - - - -
Note:
n All the pump set from 0.5 HP to 1.5 HP in mechanical seal arrangement and 2.0 HP to 20.0 HP in Gland pack arrangement except
KDS - 212+ which is supplied only in mechanical seal arrangement.
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
27
PERFORMANCE CHART FOR'KDS+/KDS++/GMC' SERIES, 2 POLE, MONOBLOC PUMP, AT RATED VOLTAGE,
50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Note:
n All the pump set from 0.5 HP to 1.5 HP in mechanical seal arrangement and 2.0 HP to 20.0 HP in Gland pack arrangement except
KDS - 212+ which is supplied only in mechanical seal arrangement.
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
28
FEATURES TECHNICAL SPECIFICATION
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
30
FEATURES TECHNICAL SPECIFICATION
Flatter Efficiency Curve Head Range - Up to 22 Metres
Minimum variations in efficiency during entire operating range increases the utility of Discharge Range - Up to 72.5 LPS
pumpset for variable conditions.
Power Rating - 2.2 to 7.5 kW (3 to 10 HP)
Voltage Range - 300 to 440 Volts (Three Phase)
Wide Voltage Design
KS The motor is designed to withstand wide voltage variation from 300 to 440 volts and
reduces motor burning in case of low/high voltage.
Insulation
Protection
-
-
B / F Class
IP44
31
PERFORMANCE CHART FOR 'KS+' SERIES, 4 POLE, MONOBLOC PUMPS, AT RATED VOLTAGE,
50Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
32
FEATURES TECHNICAL SPECIFICATION
33
PERFORMANCE CHART FOR 'SRF' SERIES, 2 POLE, MONOBLOC PUMPS, AT RATED VOLTAGE,
50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
34
35
INDUSTRIAL
PRODUCT RANGE
36
FEATURES TECHNICAL SPECIFICATION
KOSM Constructed with special grade engineering materials, compact designs for ease of
handling and installation.
Insulation
Protection
-
-
PP
IP68
Dynamically Balanced Rotating Parts
THREE PHASE Minimum vibration protects the components from damage during the operation, thus
MATERIAL OF CONSTRUCTION
OPEN-WELL PUMPS ensuring consistent performance as concentricity is maintained.
Impeller - Cast Iron / Noryl
Replaceable Wearing Parts Delivery Casing - Cast Iron
All wearing parts within the pumps are easily accessible and replaceable which Motor Body - Cast Iron
facilitates ease of maintenance thereby extending the life of the pump. Pump Shaft - Stainless Steel
Easy Maintainable Designs
Easy maintainable design and better interchangeability of components so that the APPLICATIONS
pump can be serviced even at remote locations by semi-skilled technicians.
Ÿ Domestic and community water supply
CED – Cathodic Electro Deposition Ÿ Gardening and small farm irrigation
CED is the latest coating technology for corrosion resistance with uniform coating. It Ÿ Water fountains
provides 5 times more protection over conventional painting, resulting in longer life.
All major CI parts of Kirloskar pumps coming in contact with the water are CED Ÿ Construction site
coated. Ÿ Water supply to over head tanks
37
PERFORMANCE CHART FOR 'KOS-M' SERIES, 2 POLE, OPENWELL SUBMERSIBLE PUMPS,AT RATED VOLATGE,
50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Pipe Size Rated TOTAL HEAD IN METERS
Power Rating
S. No. PUMP MODEL (mm) Voltage 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38
kW HP SUC. DEL. (Volts) DISCHARGE IN LITRES PER SECONDS
1 KOS - 116M 0.75 1.0 50 40 415 4.9 4.4 3.9 3.1 1.7 - - - - - - - - - - -
2 KOS - 123M 0.75 1.0 32 25 415 4.8 4.5 4.2 3.8 3.5 3.0 2.4 1.5 - - - - - - - -
3 KOS - 134M 0.75 1.0 25 25 415 - - 1.9 1.8 1.8 1.7 1.6 1.5 1.4 1.3 1.1 0.9 0.6 0.2 - -
4 KOS - 1.522M 1.1 1.5 50 40 415 6 5.7 5.3 4.9 4.4 3.6 2.5 - - - - - - - - -
5 KOS - 1.525M 1.1 1.5 50 40 415 - - 3.6 3.5 3.4 3.2 2.9 2.7 2.4 2.1 1.7 0.6 - - - -
6 KOS - 1.540M 1.1 1.5 32 25 415 - - - - - - - - 1.9 1.8 1.6 1.4 1.3 1.1 0.9 0.6
7 KOS - 216M 1.5 2.0 65 50 415 11.0 9.9 8.7 6.9 - - - - - - - - - - - -
8 KOS - 225M 1.5 2.0 50 40 415 - - 4.8 4.6 4.4 4.2 3.7 3.2 2.5 - - - - - - -
9 KOS - 235M 1.5 2.0 50 40 415 - - 4.4 4.2 4.0 3.8 3.6 3.3 3.0 2.7 2.3 1.7 0.8 - - -
Note:
n All models are also available in single phase. expect KOS-235M
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
38
FEATURES TECHNICAL SPECIFICATION
KOS Minimum variations in efficiency during entire operating range increases the utility of
pumpset for variable conditions.
Insulation
Protection
-
-
PP
IP68
Dynamically Balanced Rotating Parts
THREE PHASE
OPEN-WELL PUMPS Minimum vibration protects the components from damage during the operation, thus MATERIAL OF CONSTRUCTION
ensuring consistent performance as concentricity is maintained.
Impeller - Cast Iron
Replaceable Wearing Parts
Delivery Casing - Cast Iron
All wearing parts within the pumps are easily accessible and replaceable which
facilitates ease of maintenance thereby extending the life of the pump. Motor Body - Cast Iron
Pump Shaft - Stainless Steel
Easy Maintainable Designs
Easy maintainable design and better interchangeability of components so that the
pump can be serviced even at remote locations by semi-skilled technicians. APPLICATIONS
CED – Cathodic Electro Deposition
CED is the latest coating technology for corrosion resistance with uniform coating. It Ÿ Industrial service water supply schemes
provides 5 times more protection over conventional painting, resulting in longer life. Ÿ Domestic and community water supply
All major CI parts of Kirloskar pumps coming in contact with the water are CED Ÿ Construction site
coated.
Ÿ Irrigation in horticulture & agriculture
High Efficiency and Energy Saving Design Ÿ Water supplies for high rise building
Innovative design manufactured at state-of-the-art plant, delivers optimum efficiency
at lower energy consumption resulting in significant cost savings.
39
PERFORMANCE CHART FOR KOS SERIES, 2 POLE, OPENWELL SUBMERSIBLE PUMP, AT RATED VOLTAGE,
50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
40
41
INDUSTRIAL
PRODUCT RANGE
SET High grade F-Class insulation with Temperature rise limited to B-Class
#
Robust design to withstand higher temperatures reducing the chances of motor
Protection - IP55
MATERIAL OF CONSTRUCTION
ENERGY EFFICIENT burning and ensures the reliability, safety and enhanced life.
PUMPSET WITH IE5 MOTOR Impeller - Cast Iron / Stainless Steel / Bronze
High Efficiencies Achieved with AC Induction Motor Design
Rugged and most suited to work under varied field conditions. Easy to operate, Delivery Casing - Cast Iron
maintain and service at local levels as there is no use of permanent magnets / Motor Body - Cast Iron
added accessories/control equipment.
Ultra Premium Pump Shaft - Carbon Steel / Stainless Steel
Efciency IE5 Motor CED Coated Impeller
Shaft sleeve - Stainless Steel
Resistance to corrosion leading to longer life.
Sealing - Gland Packed / Mechanical Seal with
Optimum Fan and Fan Cover Design HNBR which can withstand fluid
Designed for optimum cooling with minimum power consumption and quiet
operation. temperature up to 120°C
Self-priming APPLICATIONS
No need of foot valve and priming pump set every time resulting into quicker start
up time. Ÿ Handling light chemicals, effluents, sewage,
ashwater, etc.
Non-clog Impeller Ÿ Flood / Rain water handling
Non-clog impeller to handle suspended soft solids up to 10.5 mm in size making it Ÿ Draining foundations, trenches and pits
suitable for waste water, sewage and dewatering applications. Ÿ Pumping water from docks, ports, vessels
Ÿ Draining accumulated water from basements,
Dynamically Balanced Rotating Parts Road, highways, parking lots, etc.
Minimum vibration protects the components from damage during the operation, Ÿ Cooling water for marine engines, shovels and
thus ensuring consistent performance as concentricity is maintained. piling equipment.
43
PERFORMANCE CHART FOR SP SERIES, SELF PRIMING,COUPLED SET WITH ENERGY EFFICIENT IE5 MOTORS
AT RATED RPM, THREE PHASE A.C. POWER SUPPLY
1 SP - 0 0.75 1.0 40 40 415 116 7.0 2760 4.6 4.1 3.5 2.6 1.5 0.7 - - - - - - - -
2 SP - 1H 1.5 2.0 40 40 415 134 8.5 2900 - - 6.3 5.6 4.8 4.5 3.9 3.4 2.7 1.9 - - - -
3 SP - 2H 2.2 3.0 50 50 415 145 10.5 2900 - - 9.2 8.7 8.1 7.8 7.3 6.9 6.5 6.0 5.4 4.2 2.6 1.8
20 22 23 24 26 28 30 32 34 36 38 40 42 43
4 SP - 3A 3.7 5.0 80 80 415 174 7.0 2900 10.1 9.1 8.7 8.0 6.8 5.2 3.7 1.9 - - - - - -
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
44
FEATURES TECHNICAL SPECIFICATION
MATERIAL OF CONSTRUCTION
IP55
ENERGY EFFICIENT Rugged and most suited to work under varied field conditions. Easy to operate,
PUMPSET WITH IE4 MOTOR maintain and service at local levels as there is no use of permanent magnets/added
Impeller - Cast Iron / Stainless Steel / Bronze
accessories/control equipment.
Delivery Casing - Cast Iron
Higher Specific Discharge (discharge rate per unit power) Motor Body - Cast Iron
Up to 14% less energy consumption for pumping same amount of fluid.
Premium Pump Shaft - Carbon Steel / Stainless Steel
Efciency IE4 Motor CED Coated Impeller Shaft sleeve - Stainless Steel
Resistance to corrosion leading to longer life. Sealing - Gland Packed / Mechanical Seal with
HNBR which can withstand fluid
Optimum Fan and Fan Cover Design
Designed for optimum cooling with minimum power consumption and quiet temperature up to 120°C
operation.
APPLICATIONS
Self-priming
No need of foot valve and priming pump set every time resulting into quicker start up Ÿ Handling light chemicals, effluents, sewage,
time. ashwater, etc.
Ÿ Flood / Rain water handling
Non-clog Impeller Ÿ Draining foundations, trenches and pits
Non-clog impeller to handle suspended soft solids up to 34 mm in size making it Ÿ Pumping water from docks, ports, vessels
suitable for waste water, sewage and dewatering applications.
Ÿ Draining accumulated water from basements,
Road, highways, parking lots, etc.
Dynamically Balanced Rotating Parts Ÿ Cooling water for marine engines, shovels and
Minimum vibration protects the components from damage during the operation, thus piling equipment.
ensuring consistent performance as concentricity is maintained.
45
PERFORMANCE CHART FOR SP SERIES, SELF PRIMING,COUPLED SET WITH ENERGY EFFICIENT IE4 MOTORS
AT RATED RPM, THREE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
46
FEATURES
Self Priming
No need of foot valve and priming pumpset every time for quicker operations.
APPLICATIONS
Ÿ Handling chemicals, effluents, sewage, ash-water
SP BS Ÿ Dewatering foundation, trenches and pits
Ÿ Flood water handling
Ÿ Pumping water from docks, ports, vessels
Ÿ Dewatering from basements, multi-storeys,
shopping malls, godowns
Ÿ Cooling water for marine engines and shovels
47
TECHNICAL SPECIFICATION
SP BARE SHAFT/MOTOR COUPLED SP MONOBLOC
MATERIAL OF CONSTRUCTION
SP BARE SHAFT SP MONOBLOC SP MOTOR COUPLED
Impeller - Cast Iron / Stainless Steel/ Bronze Cast iron / Stainless Steel/ Bronze Cast Iron / Stainless Steel/ Bronze
Delivery Casing - Cast Iron Cast Iron Cast Iron
Motor Body - - Cast Iron Cast Iron
Shaft - Carbon Steel / Stainless Steel Carbon Steel / Stainless Steel Carbon Steel / Stainless Steel
Shaft Sleeve - Stainless Steel Stainless Steel Stainless Steel
Sealing - Gland Packed / Mechanical Seal Gland Packed / Mechanical Seal Gland Packed / Mechanical Seal
48
PERFORMANCE CHART FOR SP SERIES, SELF PRIMING, BARE /COUPLED SET WITH ENERGY EFFICIENT IE2 MOTORS
AT RATED RPM, THREE PHASE A.C. POWER SUPPLY
Note:
n SP-8LA, SP-3HH Pump is supplied with Bare Shaft Arrangement Only.
n SP COUPLED SET with IE4 Motor is available upto 20.0 HP.
n SP COUPLED SET with IE5 Motor is available upto 5.0 HP with 2 Pole Motor Only.
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
49
PERFORMANCE CHART FOR SP-M SERIES, SELF PRIMING MONOBLOC PUMPS, AT RATED SPEED,
50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Note:
n SP-05M and SP-0M are supplied with mechanical seal arrangement and also available in single phase.
n All other models are supplied with stuffing box arrangement for gland packed or mechanical seal as per the requirement.
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
Note:
n In Engine coupled set bare shaft pump is only in the scope of KBL.
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
50
51
INDUSTRIAL
PRODUCT RANGE
VACUUM PUMPS
52
FEATURES MATERIAL OF CONSTRUCTION
KV/DV Lesser chances of motor burning as it does not get overloaded even if the pump is
operated at a head lower than recommended, thus ensuring substantial cost saving
due to low maintenance and breakdown. APPLICATIONS
VACUUM Replaceable Wearing Parts
PUMPS Ÿ Priming of large pumps
All wearing parts within the pumps are easily accessible and replaceable which
facilitates ease of maintenance thereby extending the life of the pump. Ÿ Evacuation of air from suction pipes and chambers
LIQUID RING TYPE
Ÿ Twist drilling machine, removing water from pulp
Dynamically Balanced Rotating Parts layer, labelling, bottle filling, de-odorising
Minimum vibration protect components from damage during the operation, thus Ÿ Drying, evaporation, distillation, filtration,
ensuring consistent performance as concentricity is maintained. sterilisation, condensation, degasification, sucking
gases
Ÿ Extrusion machines
TECHNICAL SPECIFICATION
KV DV
Vacuum - Up to 600 mm of mercury Up to 600 mm of mercury
KV Air Flow Rate - Up to 55 m3/hr Up to 162 m3/hr
(at mean sea level) (at mean sea level) COUPLED
Power Rating - 0.75 to 2.2 kW 3.7 to 7.5 kW WITH
(1 to 3 HP) (5 to 10 HP) IE2
MOTOR
Voltage Range - 180 to 240 Volts (Single Phase) 375 to 455 Volts
300 to 440 Volts (Three Phase) (Three Phase)
Insulation - B Class F Class
Protection - IP44 IP55
DV
DV Coupled Set
53
PERFORMANCE CHART FOR 'KV/DV' SERIES, VACUUM PUMPS, AT RATED SPEED, 50 Hz FREQUENCY,
THREE PHASE A.C. POWER SUPPLY
Note:
n KV-20 is also available in Single Phase. Performance applicablle for air at NTP based on employment of clear water at 30° C as working fluid.
n * Coupled sets with Energy Efficient IE2 motors.
54
55
INDUSTRIAL
PRODUCT RANGE
VERTICAL MULTISTAGE
INLINE PUMPS
56
FEATURES
Wide Operating Range with Flatter Characteristics for a Stable Head Range - Up to 181 Metres
Performance. Discharge Range - Up to 25 m3/hr
Minimum variations in efficiency during entire operating range increases the Power Rating - 1.1 to 4.5 kW (1.5 to 6 HP)
utility of pump set for variable conditions. Flatter performance curve ensure Voltage Range - 180 to 240 Volts (Single Phase)
wide operating range.
300 to 440 Volts (KVM 2 m3/hr – 3 phase)
KVM Engineering Polymer Impellers and Diffuser
Excellent chemical resistance to most of the acids, bases, chlorides and
350 to 440 Volts (KVM 4 m3 /hr – 3 phase)
370 to 440 Volts (KVM 10 & 15 m3/hr - 3 phase IE2)
VERTICAL cleaning agents Excellent hydrolytic stability Excellent long term dimensional Insulation - F Class
MULTI STAGE PUMPS stability for reliable and consistent performance Protection - IP44/ IP55
pH Value - 5 - 8.5
Keyed Shaft
Positive impeller locking for better life
Wide Voltage Range Diffuser & Impeller - High Grade Engineering Polymer
The motor is designed to withstand wide voltage variation which reduces motor
Discharge Casing - Cast Iron
burning in case of low/high voltage.
Suction Casing - Cast Iron
Light-weight Pump shaft - Stainless Steel
Easy handling and easy to integrate in the system
APPLICATIONS
High Efficiency
Low power consumption Ÿ RO Plant
Ÿ Pressure boosting and lifting water in apartments and
CED Coating
CED is the latest coating technology for corrosion resistance that comes with an bungalows
uniform coating, which provides 5 times more protection over conventional Ÿ Irrigation
painting, resulting in longer life. All major CI parts of Kirloskar pumps that come Ÿ Firefighting systems and washing systems
in contact with water are CED coated.
Ÿ Air conditioners, cooling system and industrial cleaning
Cartridge Type Mechanical Seal
Superior quality cartridge type mechanical seal with high quality graphite and
hard alloy ensures better heat resistance capacity, zero leakage and lower
friction loss. This protects the shaft from wear and tear thus ensuring easy
maintenance without opening the pump for a longer life.
57
PERFORMANCE CHART FOR KVM 2 m3/hr SERIES, 2 POLE, AT RATED VOLTAGE OF 230/415 VOLTS,
50 Hz FREQUENCY, SINGLE/THREE PHASE A.C. POWER SUPPLY
Pipe Size
Power Rating lps 0.28 0.42 0.56 0.69 0.83 0.97 1.11 1.25 1.39 1.53
(mm) No of
S. No. PUMP MODEL
Stages
kW HP SUC. DEL. m3/hr 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
PERFORMANCE CHART FOR KVM 4 m3/hr SERIES, 2 POLE, AT RATED VOLTAGE OF 230/415 VOLTS,
50 Hz FREQUENCY, SINGLE/THREE PHASE A.C. POWER SUPPLY
Pipe Size
Power Rating lps 0.28 0.56 0.83 1.11 1.39 1.67 1.94 2.22 2.50
(mm) No of
S. No. PUMP MODEL
Stages
kW HP SUC. DEL. m3/hr 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0
PERFORMANCE CHART FOR KVM 10 m3/hr SERIES, 2 POLE, AT RATED VOLTAGE OF 415 VOLTS,
50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Pipe Size
Power Rating lps 0.56 1.11 1.67 2.22 2.78 3.33 3.89 4.44 5.00
(mm) No of
S. No. PUMP MODEL
Stages
kW HP SUC. DEL. m3/hr 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0
PERFORMANCE CHART FOR KVM 15 m3/hr SERIES, 2 POLE, AT RATED VOLTAGE OF 415 VOLTS,
50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Pipe Size
Power Rating lps 0.83 1.67 2.50 3.33 4.17 5.00 5.83 6.66 6.94
(mm) No of
S. No. PUMP MODEL
Stages
kW HP SUC. DEL. m3/hr 3.0 6.0 9.0 12.0 15.0 18.0 21.0 24.0 25.0
1 KVM - 15045 3.7 5.0 65 65 4 Total Head 53.5 52.5 50.5 48 45 40.5 35 29 26
2 KVM - 15072 4.5 6.0 65 65 6 in meters 85 82 80 76.5 72 66 59 49 45
Note:
n KVM 10 and KVM 15 Series are supplied with IE2 three phase motor as standard scope of supply and also available in IE4 Motor.
n Above KVM 10 & KVM 15 series are Inline models.
n Performance under standard test conditions and may vary on site conditions.
58 n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
FEATURES TECHNICAL SPECIFICATION
Superior Pump Hydraulics Head Range - Up to 323 Metres
Superior pump hydraulics due to advanced manufacturing processes coupled with Discharge Range - Up to 110 m³/h
IE2 motor facilitate higher efficiency at par with international standard.
Power Rating - 0.37 to 45 kW
Cartridge Type Mechanical Seal (0.5 to 60 HP)
Superior quality cartridge type mechanical seal with high quality graphite and hard Voltage Range - 370 to 440 Volts
KCIL/KSIL alloy ensures better heat resistance capacity, zero leakage and lower friction loss.
This protects the shaft from wear and tear thus ensuring easy maintenance without
Protection
(Three Phase)
- IP55
opening the pump for a longer life.
VERTICAL MULTI STAGE Insulation - F Class
INLINE PUMPS Splined Shaft
Splined shaft made from cold extrusion technology with high surface strength pH Value - 4 to 10
facilitates better life and good axiality. Altitude - Up to 1000 metres
Liquid Temperature Range - -20° C to 120°C
Replaceable Wearing Parts
All wearing parts within the pumps are easily accessible and replaceable which Motors - All motors are designed
facilitates ease of maintenance thereby extending the life of the pump. under IE2 specification.
Maximum Operating
Dynamically Balanced Rotating Parts Pressure - 16 bar
Minimum vibration protect components from damage during the operation, thus (KCIL & KSIL-1 to 5 Series)
ensuring consistent performance as concentricity is maintained.
25 bar
Easy Maintainable Designs (KSIL & KCIL-10 to 90 Series)
Easy maintainable design and better interchangeability of components.
KCIL
KSIL 59
MATERIAL OF CONSTRUCTION
KCIL KSIL
Base Plate - Cast Iron Cast Iron
Drainage Plug Assembly - Stainless Steel Stainless Steel
Primary Diffuser - Stainless Steel Stainless Steel
Diffuser with Bearing - Stainless Steel Stainless Steel
Medium Diffuser - Stainless Steel Stainless Steel
Impeller - Stainless Steel Stainless Steel
Final Diffuser - Stainless Steel Stainless Steel
Motor Base - Cast Iron Cast Iron
Vent Plug Assembly - Stainless Steel Stainless Steel
Pump Shaft - Stainless Steel Stainless Steel
Pump Casing (Suc & Del) - Cast Iron Stainless Steel
APPLICATIONS
• Building Industry - Booster, Fire fighting, Hydro pneumatic systems, Heating, Ventilation and Air conditioning systems.
• Water Treatment - Reverse osmosis systems, softening, Ion exchange, demineralizing systems, distillation systems
60
PERFORMANCE CHART FOR KCIL / KSIL PUMPSETS - 1 SERIES, AT RATED VOLTAGE OF 415 VOLTS,
50 HZ FREQUENCY, THREE PHASE A.C. POWER SUPPLY
No DISCHARGE IN m³/hr
Power Rating Pipe Size (mm)
S. of
Pump Model 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
No. Stages
kW HP SUC. DEL. TOTAL HEAD IN METRES
1 KSIL/KCIL1-2 0.37 0.5 32 32 2 12 12 12 12 12 11 11 10 10
2 KSIL/KCIL1-3 0.37 0.5 32 32 3 18 18 18 18 17 17 16 15 14
3 KSIL/KCIL1-4 0.37 0.5 32 32 4 24 24 24 23 22 22 21 19 18
4 KSIL/KCIL1-5 0.37 0.5 32 32 5 30 30 30 29 28 27 26 24 22
5 KSIL/KCIL1-6 0.37 0.5 32 32 6 36 36 35 35 34 32 30 28 25
6 KSIL/KCIL1-7 0.37 0.5 32 32 7 42 42 41 41 39 37 35 32 30
7 KSIL/KCIL1-8 0.55 0.75 32 32 8 48 48 47 46 45 43 40 37 34
8 KSIL/KCIL1-9 0.55 0.75 32 32 9 54 54 53 52 50 48 45 41 37
9 KSIL/KCIL1-10 0.55 0.75 32 32 10 60 59 58 57 55 53 50 46 41
10 KSIL/KCIL1-11 0.55 0.75 32 32 11 65 65 64 62 61 58 54 50 45
11 KSIL/KCIL1-12 0.75 1.0 32 32 12 73 72 71 69 67 64 61 55 50
12 KSIL/KCIL1-13 0.75 1.0 32 32 13 78 78 77 75 73 69 65 60 54
13 KSIL/KCIL1-15 0.75 1.0 32 32 15 90 90 88 86 83 79 74 68 61
14 KSIL/KCIL1-17 1.1 1.5 32 32 17 103 102 101 99 95 91 85 79 70
15 KSIL/KCIL1-19 1.1 1.5 32 32 19 115 114 112 109 106 101 94 87 78
16 KSIL/KCIL1-21 1.1 1.5 32 32 21 126 125 123 120 116 110 103 95 85
17 KSIL/KCIL1-23 1.1 1.5 32 32 23 137 136 134 131 126 120 112 103 92
18 KSIL/KCIL1-25 1.5 2.0 32 32 25 153 152 150 147 142 136 128 118 106
19 KSIL/KCIL1-27 1.5 2.0 32 32 27 165 164 162 158 153 146 137 127 114
20 KSIL/KCIL1-30 1.5 2.0 32 32 30 182 181 178 175 169 162 152 140 126
21 KSIL/KCIL1-33 2.2 3.0 32 32 33 203 202 199 195 189 181 170 157 142
22 KSIL/KCIL1-36 2.2 3.0 32 32 36 221 220 217 212 206 197 185 171 154
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
61
PERFORMANCE CHART FOR KCIL / KSIL PUMPSETS - 2 SERIES, AT RATED VOLTAGE OF 415 VOLTS,
50 HZ FREQUENCY, THREE PHASE A.C. POWER SUPPLY
No DISCHARGE IN m³/hr
Power Rating Pipe Size (mm)
S. of
Pump Model 1.0 1.2 1.6 2.0 2.4 2.8 3.2 3.5
No. Stages
kW HP SUC. DEL. TOTAL HEAD IN METRES
1 KSIL/KCIL2-2 0.37 0.50 32 32 2 18 17 16 15 13 12 10 8
2 KSIL/KCIL2-3 0.37 0.50 32 32 3 27 26 24 22 20 18 15 12
3 KSIL/KCIL2-4 0.55 0.75 32 32 4 36 35 33 30 26 24 17 16
4 KSIL/KCIL2-5 0.55 0.75 32 32 5 45 43 40 37 33 30 24 20
5 KSIL/KCIL2-6 0.75 1.00 32 32 6 53 52 50 45 40 36 30 24
6 KSIL/KCIL2-7 0.75 1.00 32 32 7 63 61 57 52 47 41 35 28
7 KSIL/KCIL2-8 1.10 1.50 32 32 8 71 69 65 59 54 47 40 33
8 KSIL/KCIL2-9 1.10 1.50 32 32 9 80 78 73 67 61 54 45 37
9 KSIL/KCIL2-10 1.10 1.50 32 32 10 89 86 81 74 67 59 49 40
10 KSIL/KCIL2-11 1.10 1.50 32 32 11 98 95 89 82 73 64 54 44
11 KSIL/KCIL2-12 1.50 2.00 32 32 12 107 103 97 90 81 71 59 47
12 KSIL/KCIL2-13 1.50 2.00 32 32 13 116 114 106 98 89 78 65 52
13 KSIL/KCIL2-14 1.50 2.00 32 32 14 125 122 118 105 94 84 69 57
14 KSIL/KCIL2-15 1.50 2.00 32 32 15 134 130 123 112 100 90 73 60
15 KSIL/KCIL2-16 2.20 3.00 32 32 16 143 139 131 120 107 96 79 66
16 KSIL/KCIL2-17 2.20 3.00 32 32 17 152 148 139 128 114 102 85 70
17 KSIL/KCIL2-18 2.20 3.00 32 32 18 161 157 148 136 121 108 91 76
18 KSIL/KCIL2-19 2.20 3.00 32 32 19 170 165 156 143 127 113 95 81
19 KSIL/KCIL2-20 2.20 3.00 32 32 20 179 174 164 150 134 119 100 85
20 KSIL/KCIL2-21 2.20 3.00 32 32 21 188 183 172 157 141 124 105 88
21 KSIL/KCIL2-22 2.20 3.00 32 32 22 197 192 180 165 148 130 110 90
22 KSIL/KCIL2-23 3.00 4.00 32 32 23 204 201 188 173 155 137 117 97
23 KSIL/KCIL2-24 3.00 4.00 32 32 24 214 210 197 181 163 144 120 105
24 KSIL/KCIL2-25 3.00 4.00 32 32 25 223 219 205 189 168 151 125 107
25 KSIL/KCIL2-26 3.00 4.00 32 32 26 232 228 214 198 178 158 130 110
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
62
PERFORMANCE CHART FOR KCIL / KSIL PUMPSETS - 3 SERIES, AT RATED VOLTAGE OF 415 VOLTS,
50 HZ FREQUENCY, THREE PHASE A.C. POWER SUPPLY
DISCHARGE IN m³/hr
Power Rating Pipe Size (mm) No
S. of 1.2 1.6 2.0 2.4 2.8 3.0 3.2 3.6 4.0
Pump Model
No. Stages
kW HP SUC. DEL.
TOTAL HEAD IN METRES
17 KSIL/KCIL3-23 2.2 3.0 32 32 23 146 141 135 128 119 114 108 95 81
18 KSIL/KCIL3-25 2.2 3.0 32 32 25 158 153 146 138 128 123 117 102 87
19 KSIL/KCIL3-27 2.2 3.0 32 32 27 170 164 157 148 138 132 125 110 93
20 KSIL/KCIL3-29 2.2 3.0 32 32 29 182 176 168 159 147 140 133 118 100
21 KSIL/KCIL3-31 3 4.0 32 32 31 197 191 183 173 161 153 146 128 110
22 KSIL/KCIL3-33 3 4.0 32 32 33 210 203 194 183 170 162 152 137 116
23 KSIL/KCIL3-36 3 4.0 32 32 36 228 221 211 200 185 177 168 149 126
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
63
PERFORMANCE CHART FOR KCIL / KSIL PUMPSETS - 4 SERIES, AT RATED VOLTAGE OF 415 VOLTS,
50 HZ FREQUENCY, THREE PHASE A.C. POWER SUPPLY
DISCHARGE IN m³/hr
Power Rating Pipe Size (mm) No
S. of
Pump Model 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0
No. Stages
kW HP SUC. DEL.
TOTAL HEAD IN METRES
20 KSIL/KCIL4-21 4.00 5.50 32 32 21 203 190 184 169 152 132 103 75
21 KSIL/KCIL4-22 4.00 5.50 32 32 22 211 200 192 178 160 138 108 79
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
64
PERFORMANCE CHART FOR KCIL / KSIL PUMPSETS - 5 SERIES, AT RATED VOLTAGE OF 415 VOLTS,
50 HZ FREQUENCY, THREE PHASE A.C. POWER SUPPLY
DISCHARGE IN m³/hr
Power Rating Pipe Size (mm) No
S. of
Pump Model 1 2 3 4 5 6 7
No. Stages
kW HP SUC. DEL.
TOTAL HEAD IN METRES
4 KSIL/KCIL5-5 0.75 1 32 32 5 33 32 30 28 24 22 18
8 KSIL/KCIL5-9 1.5 2 32 32 9 60 59 56 53 48 44 37
9 KSIL/KCIL5-10 1.5 2 32 32 10 67 65 62 59 54 48 41
10 KSIL/KCIL5-11 2.2 3 32 32 11 74 73 70 66 61 54 47
11 KSIL/KCIL5-12 2.2 3 32 32 12 81 79 76 72 66 59 51
12 KSIL/KCIL5-13 2.2 3 32 32 13 88 85 82 78 71 64 55
13 KSIL/KCIL5-14 2.2 3 32 32 14 95 92 89 83 77 69 60
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
65
PERFORMANCE CHART FOR KCIL / KSIL PUMPSETS - 10 SERIES, AT RATED VOLTAGE OF 415 VOLTS,
50 HZ FREQUENCY, THREE PHASE A.C. POWER SUPPLY
DISCHARGE IN m³/hr
Power Rating Pipe Size (mm) No
S. of 2 4 6 8 10 12
Pump Model
No. Stages
kW HP SUC. DEL.
TOTAL HEAD IN METRES
2 KSIL/KCIL10-2 0.75 1 42 42 2 20 20 19 18 15 12
4 KSIL/KCIL10-4 1.5 2 42 42 4 40 40 40 36 32 26
5 KSIL/KCIL10-5 2.2 3 42 42 5 51 51 50 46 40 33
6 KSIL/KCIL10-6 2.2 3 42 42 6 61 61 59 55 48 39
7 KSIL/KCIL10-7 3.0 4 42 42 7 72 72 70 65 56 46
8 KSIL/KCIL10-8 3.0 4 42 42 8 82 82 80 74 64 53
9 KSIL/KCIL10-9 3.0 4 42 42 9 92 92 89 82 70 59
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
66
PERFORMANCE CHART FOR KCIL / KSIL PUMPSETS - 15 SERIES, AT RATED VOLTAGE OF 415 VOLTS,
50 HZ FREQUENCY, THREE PHASE A.C. POWER SUPPLY
DISCHARGE IN m³/hr
Power Rating Pipe Size (mm) No
S. of
Pump Model 3 6 9 12 15 18 21
No. Stages
kW HP SUC. DEL.
TOTAL HEAD IN METRES
2 KSIL/KCIL15-2 2.2 3 65 65 2 28 27 26 25 23 21 18
3 KSIL/KCIL15-3 3 4 65 65 3 42 41 40 38 35 32 28
4 KSIL/KCIL15-4 4 5.5 65 65 4 58 55 55 51 47 43 38
5 KSIL/KCIL15-5 4 5.5 65 65 5 70 68 66 64 58 53 48
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
67
PERFORMANCE CHART FOR KCIL / KSIL PUMPSETS - 20 SERIES, AT RATED VOLTAGE OF 415 VOLTS,
50 HZ FREQUENCY, THREE PHASE A.C. POWER SUPPLY
DISCHARGE IN m³/hr
Power Rating Pipe Size (mm) No
S. Pump Model of 4 8 12 16 20 24 28
No. Stages
kW HP SUC. DEL.
TOTAL HEAD IN METRES
2 KSIL/KCIL20-2 2.2 3 65 65 2 28 28 27 25 23 19 15
3 KSIL/KCIL20-3 4.0 5 65 65 3 43 43 42 39 36 30 23
6 KSIL/KCIL20-6 7.5 10 65 65 6 87 84 83 80 72 62 49
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
68
PERFORMANCE CHART FOR KCIL PUMPSETS - 32 SERIES, AT RATED VOLTAGE OF 415 VOLTS,
50 HZ FREQUENCY, THREE PHASE A.C. POWER SUPPLY
No DISCHARGE IN m³/hr
Power Rating Pipe Size (mm)
S. of 15 20 25 32 35 40
No. Pump Model
Stages
kW HP SUC. DEL.
TOTAL HEAD IN METRES
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
69
PERFORMANCE CHART FOR KCIL PUMPSETS - 45 SERIES, AT RATED VOLTAGE OF 415 VOLTS,
50 HZ FREQUENCY, THREE PHASE A.C. POWER SUPPLY
DISCHARGE IN m³/hr
Power Rating Pipe Size (mm) No
S. Pump Model of 25 30 35 40 45 50 55
No. Stages
kW HP SUC. DEL.
TOTAL HEAD IN METRES
13 KCIL45-7-2 30.0 40.0 80 80 7 168 163 156 147 135 123 109
14 KCIL45-7 30.0 40.0 80 80 7 176 171 163 155 144 132 116
15 KCIL45-8-2 30.0 40.0 80 80 8 193 187 179 168 155 142 126
16 KCIL45-8 30.0 40.0 80 80 8 200 194 187 176 164 149 134
17 KCIL45-9-2 30.0 40.0 80 80 9 217 211 202 189 174 159 142
18 KCIL45-9 30.0 40.0 80 80 9 226 219 210 199 185 170 151
19 KCIL45-10-2 37.0 50.0 80 80 10 242 236 225 212 196 179 159
20 KCIL45-10 37.0 50.0 80 80 10 251 243 233 220 205 187 166
21 KCIL45-11-2 45.0 60.0 80 80 11 273 264 253 238 222 201 179
22 KCIL45-11 45.0 60.0 80 80 11 281 272 261 246 230 209 187
23 KCIL45-12-2 45.0 60.0 80 80 12 298 289 276 261 242 220 195
24 KCIL45-12 45.0 60.0 80 80 12 306 296 284 268 251 229 204
25 KCIL45-13-2 45.0 60.0 80 80 13 323 313 300 283 263 239 212
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
70
PERFORMANCE CHART FOR KCIL PUMPSETS - 64 SERIES, AT RATED VOLTAGE OF 415 VOLTS,
50 HZ FREQUENCY, THREE PHASE A.C. POWER SUPPLY
DISCHARGE IN m³/hr
Power Rating Pipe Size (mm) No
S. of
Pump Model 30 40 50 64 70 80
No. Stages
kW HP SUC. DEL.
TOTAL HEAD IN METRES
13 KCIL64-5-1 30.0 40.0 100 100 5 134 129 122 109 102 88
14 KCIL64-5 30.0 40.0 100 100 5 141 136 129 116 109 96
15 KCIL64-6-2 30.0 40.0 100 100 6 154 148 140 124 115 99
16 KCIL64-6-1 37.0 50.0 100 100 6 162 156 148 132 124 108
17 KCIL64-6 37.0 50.0 100 100 6 170 163 155 139 131 116
18 KCIL64-7-2 37.0 50.0 100 100 7 182 176 166 147 138 119
19 KCIL64-7-1 37.0 50.0 100 100 7 190 183 173 155 145 126
20 KCIL64-7 45.0 60.0 100 100 7 202 194 184 165 155 136
21 KCIL64-8-2 45.0 60.0 100 100 8 214 207 196 174 163 140
22 KCIL64-8-1 45.0 60.0 100 100 8 222 214 203 181 170 148
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
71
PERFORMANCE CHART FOR KCIL PUMPSETS - 90 SERIES, AT RATED VOLTAGE OF 415 VOLTS,
50 HZ FREQUENCY, THREE PHASE A.C. POWER SUPPLY
DISCHARGE IN m³/hr
Power Rating Pipe Size (mm) No
S. Pump Model of 50 60 70 80 90 100 110
No. Stages
kW HP SUC. DEL.
TOTAL HEAD IN METRES
10 KCIL90-5 37.0 50.0 100 100 5 142 136 129 121 111 101 87
11 KCIL90-6-2 45.0 60.0 100 100 6 161 154 145 135 123 108 92
12 KCIL90-6 45.0 60.0 100 100 6 175 166 156 146 135 123 108
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
72
73
INDUSTRIAL
PRODUCT RANGE
STAINLESS STEEL
MONOBLOC PUMP
74
FEATURES
High Efficiency and Energy Saving Design
Head Range - Up to 55 Meters
Innovative design manufactured at state-of-the-art plant, delivers optimum
Discharge Range - Up to 12 m3/h
efficiency at lower energy consumption resulting in significant cost savings.
Power Rating - 0.37 to 2.2 kW (0.5 to 3 HP)
Voltage Range - 220 Volts±10% and 415 Volts±10%
Compact Reliable and Silent
AGNES Dynamically balanced rotating parts, superior quality bearings and SS fabricated
Insulation
Protection
-
-
F Class
IP55
impellers with compact design ensures reliable and silent operations Max Liquid Temp - 85° C
HORIZONTAL MULTISTAGE
PUMP High Head Applications
The pump has been designed for high head applications, helping customers to
Impeller - SS 304
achieve high turnaround time and productivity
Diffuser - SS 304
Delivery Casing - Cast Iron
Dynamically Balanced Rotating Parts
Shaft - SS-304
Minimum vibration protect components from damage during the operation, thus
Motor Body - Aluminium
ensuring consistent performance as concentricity is maintained.
Mechanical Seal - Carbon vs Ceramic
APPLICATIONS
75
PERFORMANCE CHART FOR AGNES 2 SERIES PUMP, 2POLE, AT RATED VOLTAGE OF 220/415 VOLTS,
50 HZ FREQUENCY, SINGLE/THREE PHASE A.C. POWER SUPPLY’
Sr. Pump Model Power Rating Current Pipe Size (mm) DISCHARGE
3
No. kW HP 1Ø 3Ø Suc Del Q (m /h) 0 0.6 1.2 1.8 2.4 3.0 3.6
1 AGNES 2-20 0.37 0.5 2.4 1.1 25 25 18.0 16.0 15.0 13.0 12.0 10.0 8.0
2 AGNES 2-30 0.37 0.5 2.8 1.3 25 25 27.0 24.0 22.0 20.0 18.0 16.0 12.0
Head (m)
3 AGNES 2-40 0.55 0.75 3.3 1.5 25 25 35.0 33.0 30.0 26.0 24.0 21.0 16.0
4 AGNES 2-50 0.55 0.75 3.6 1.9 25 25 45.0 40.0 37.0 33.0 30.0 24.0 19.0
5 AGNES 2-60 0.75 1.0 4.5 2.1 25 25 53.0 50.0 45.0 40.0 36.0 30.0 23.0
PERFORMANCE CHART FOR AGNES 4 SERIES PUMP, 2POLE, AT RATED VOLTAGE OF 220/415 VOLTS,
50 Hz FREQUENCY, SINGLE/THREE PHASE A.C. POWER SUPPLY’
Sr. Model Pump Power Rating Current Pipe Size (mm) DISCHARGE
3
No. kW HP 1Ø 3Ø Suc Del Q (m /h) 0 1 2 3 4 5 6 7
1 AGNES 4-20 0.55 0.75 3.5 1.9 32 25 18.0 17.0 16.0 15.0 13.0 12.0 10.0 8.0
Head (m)
2 AGNES 4-30 0.55 0.75 3.5 1.9 32 25 28.0 27.0 25.0 23.0 21.0 19.0 16.0 13.0
3 AGNES 4-40 0.75 1.0 4.5 2.1 32 25 38.0 36.0 34.0 32.0 28.0 26.0 22.0 17.0
4 AGNES 4-50 1.1 1.5 6.2 2.7 32 25 48.0 46.0 43.0 40.0 36.0 33.0 28.0 21.0
5 AGNES 4-60 1.1 1.5 6.2 2.7 32 25 58.0 55.0 52.0 48.0 43.0 39.0 33.0 26.0
PERFORMANCE CHART FOR AGNES 10 SERIES , 2POLE, AT RATED VOLTAGE OF 220/415 VOLTS,
50 Hz FREQUENCY, SINGLE/THREE PHASE A.C. POWER SUPPLY
2 AGNES 10-20 0.75 1.0 4.4 1.9 38 32 19.5 19 18.7 17.9 17.1 16.3 15.3 14.0 12.5 10.6
Head (m)
3 AGNES 10-30 1.1 1.5 6.3 2.6 38 32 29.3 28.6 28.3 27.1 26.3 24.9 23.4 21.4 19.3 16.9
4 AGNES 10-40 1.5 2.0 8.2 3.3 38 32 38.1 39.6 39.8 38.6 37.6 35.9 33.9 31.2 28.2 24.6
5 AGNES 10-50 2.2 3.0 10.0 4.1 38 32 49.9 49.2 49.1 47.8 46.4 44.4 42.2 39.5 35.9 31.1
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
76
FEATURES TECHNICAL SPECIFICATION
Stainless Steel – Wetted Components Head Range - Up to 50 Metres
All wetted components are made of Stainless Steel which made it suitable for
Discharge Range - Up to 18 LPS
handling various liquids.
Power Rating - 0.75 to 7.5 kW(1 to 10 HP)
Mechanical Seal Voltage Range - 350 to 440 Volts
Superior quality of mechanical seal ensures zero leakage, lower friction loss, protects (Three Phase)
KSMB from wearing of shaft, thus resulting in easy maintenance and longer life. Insulation
Protection
-
-
F Class
IP44 / IP55
High Efficiency and Energy Saving Design
STAINLESS STEEL Innovative design manufactured at state of art plant, delivers optimum efficiency at pH Value - 5 to 9
MONOBLOC PUMPSETS lower energy consumption resulting in significant cost savings. Liquid Temperature - -10°C to 85°C (Up to 3 HP)
Range - -20°C to 100°C
Superior Hydraulics
(5 HP and above)
Superior hydraulics due to advanced manufacturing processes provides efficiency at
Maximum Ambient Temperature - 40°C
par with international standard.
Ÿ Pharmaceutical industries
Ÿ Food processing
Ÿ Demineralising plant
Ÿ Air conditioning and refrigeration systems
Ÿ Diary and beverages
77
PERFORMANCE CHART FOR KSMB SERIES, STAINLESS STEEL MONOBLOC PUMP, AT RATED VOLTAGE,
50 HZ FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
78
79
INDUSTRIAL
PRODUCT RANGE
SEWAGE DE-WATERING
SUBMERSIBLE PUMPS
80
FEATURES TECHNICAL SPECIFICATION
ETERNA CW
81
PERFORMANCE CHART FOR ETERNA CW+ / CW SERIES, SEWAGE DE-WATERING PUMPS, AT RATED VOLTAGE,
50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
82
FEATURES
Special Cutter
Equipped with a effective and reliable grinder system which grinds solids into Head Range - Up to 39 Meters
Discharge Range - Up to 365 LPM
small pieces so that they can be drawn away through discharge pipes of a
Power Rating - 1.2 to 4 kW
relatively small diameter.
(1.6 to 5.5 HP)
Stainless Steel Clamp Ÿ Waste water with discharge from water closets
Easy and quick dismantling of pump casing without the use of any special tool Ÿ Sewage from restaurants / hotels / camping sites etc
that enables 180 degree rotation of the pump casing. Easily serviceable, suitable Ÿ Effluents from abattoirs
for both temporary and permanent installation and can either be installed on auto Ÿ Effluents & waste from waste water or effluent
coupling system or can stand freely at the bottom of the pit. treatment plants.
Ÿ Sewage treatment in communities or area where no
sewer system is available
CWC
83
PERFORMANCE CHART FOR CWC SERIES, CUTTER PUMP, AT RATED VOLTAGE, 50 HZ FREQUENCY,
THREE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
84
FEATURES PRODUCT
TECHNICAL SNAPSHOT
SPECIFICATION
SW/BW No installation required, just drop it in the tank, and it is ready to use. Voltage Range
Protection
- 180 to 240 Volts (Single Phase)
- IP68
Corrosion Free
Stainless steel body and other rust free parts prevent corrosion. Insulation - SW - F Class / BW - B Class
SEWAGE DE-WATERING
SUBMERSIBLE PUMPS Cable Length - 9.5 meters
TOP - Thermal Overload Protector pH Value - 4 - 10
The pump set features a Thermal Overload Protector that protects the motor from
Max. Liquid density - 1.2 x 103 kg/m3
overloading, shielding of the motor and associated circuit from the effects of fault
current. Max. liquid temperature - +40O C
MATERIAL OF CONSTRUCTION
SW BW
Impeller - Noryl Cast Iron
Delivery Casing - Stainless Steel Cast Iron
Motor Body - Stainless Steel Stainless Steel
Pump Shaft - Stainless Steel Stainless Steel
Cutter - - 40 Cr Steel
APPLICATIONS
85
PERFORMANCE CHART FOR SW AND BW PUMPS AT RATED VOLTAGE, 50 Hz FREQUENCY,
SINGLE-PHASE AC POWER SUPPLY
3 1300BW 1.3 1.75 50 220 - - - 270 240 204 162 132 60 10 530
4 1800BW 1.8 2.5 65 220 - - - 330 300 240 180 120 - 10 630
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
86
FEATURES TECHNICAL SPECIFICATION
87
PERFORMANCE CHART OF ‘KPP SERIES’-2 POLE PUMPS, AT RATED VOLTAGE, 50HZ FREQUENCY,
SINGLE PHASE A.C. POWER SUPPLY
HEAD (m)
2 KPP - 800 0.75 1.0 50 50 220 10.8 10.3 9.2 7.0 4.5 1.5 - - - -
3 KPP - 1100 1.10 1.5 50 50 220 14.8 14.2 13.2 12.0 10.3 8.0 4.8 - - -
4 KPP - 1600 1.50 2.0 50 50 220 16.8 16.3 15.5 14.5 13.5 12.0 9.6 7.0 3.5 -
5 KPP - 2200 2.20 3.0 50 50 220 17.9 17.5 16.7 15.9 14.7 13.4 11.6 9.5 7.0 3.5
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
88
89
AGRICULTURE
PRODUCT RANGE
MONOBLOC PUMPS
Single Phase
90
FEATURES TECHNICAL SPECIFICATION
Wide Voltage Design Head Range - Up to 52 Metres
The motor is designed to withstand wide voltage variation which reduces motor Discharge Range - Up to 28 LPS
burning in case of low/high voltage. Power Rating - 0.37 to 3.7 kW
Replaceable Wearing Parts (0.5 to 5.0 HP)
All wearing parts within the pumps are easily accessible and replaceable which Voltage Range - 180 to 240 Volts (Single Phase)
KDS facilitates ease of maintenance thereby extending the life of the pump. 120 to 220 Volts (Low Voltage)
230 to 400 Volts (“P” Series)
TOP - Thermal Overload Protector
SINGLE PHASE The pump set features a Thermal Overload Protector that protects the motor from Insulation - B / F Class
MONOBLOC PUMPS overloading, shielding of the motor and associated circuit from the effects of fault Protection - IP44
current
91
PERFORMANCE CHART FOR KDS SERIES, 2 POLE, MONOBLOC PUMP, AT RATED VOLTAGE,
50 Hz FREQUENCY, SINGLE PHASE A.C. POWER SUPPLY
Power Pipe Size Rated TOTAL HEAD IN METRES
S. N. PUMP MODEL Rating (mm) Voltage 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34
kW HP SUC. DEL. (Volts) DISCHARGE IN LITRES PER SECOND
1 KDS - 0510+ 0.37 0.50 50 40 210 - 3.4 2.6 1.0 - - - - - - - - - - - -
2 KDS - 112 0.75 1.00 50 50 210 - 6.9 5.5 3.9 2.0 - - - - - - - - - - -
3 KDS - 116++ 0.75 1.00 50 40 210 - 5.4 5.0 4.6 4.2 3.6 3.0 1.9 - - - - - - - -
4 KDS - 116++ 0.75 1.00 50 50 210 - 5.4 5.0 4.6 4.2 3.6 3.0 1.9 - - - - - - - -
5 KDS - 123+ 0.75 1.00 32 25 210 - - - 4.1 3.6 3.2 2.7 2.2 1.7 0.9 - - - - - -
6 KDS - 128+ 0.75 1.00 32 25 210 - - - - 1.9 1.85 1.8 1.7 1.6 1.4 1.1 0.8 0.4 - - -
7 KDS - 128+ 0.75 1.00 50 40 210 - - - - 1.9 1.85 1.8 1.7 1.6 1.4 1.1 0.8 0.4 - - -
8 KDS - 128+ 0.75 1.00 40 40 210 - - - - 1.9 1.85 1.8 1.7 1.6 1.4 1.1 0.8 0.4 - - -
9 KDS - 134+ 0.75 1.00 25 25 210 - - - - - - - 2.1 1.9 1.7 1.5 1.3 1.0 0.7 - -
10 KDS - 1.514 1.10 1.50 65 50 210 - - 8.5 7.1 5.7 3.0 - - - - - - - - - -
11 KDS - 1.514++ 1.10 1.50 50 50 210 - - 8.5 7.1 5.7 3.0 - - - - - - - - - -
12 KDS - 1.522++ 1.10 1.50 50 40 210 - - 6.3 5.9 5.5 5.0 4.5 3.9 3.1 1.8 - - - - - -
13 KDS - 1.525+ 1.10 1.50 50 40 210 - 2.6 2.55 2.5 2.45 2.4 2.3 2.2 2.1 2.0 1.8 1.6 1.3 0.4 - -
14 KDS - 211N 1.50 2.00 80 80 230 14.3 12.7 10.7 8.0 - - - - - - - - - - - -
15 KDS - 216M 1.50 2.00 80 80 230 - - 11.0 10.1 8.8 7.1 4.0 - - - - - - - - -
16 KDS - 216++ 1.50 2.00 65 50 230 - - 11.0 10.1 8.8 7.1 4.0 - - - - - - - - -
17 KDS - 222 1.50 2.00 65 50 220 - - - 8.4 8.0 7.5 6.7 5.7 4.2 2.0 - - - - - -
18 KDS - 225++ 1.50 2.00 50 50 230 - - 5.3 5.1 4.9 4.7 4.5 4.2 3.9 3.5 2.8 - - - - -
19 KDS - 225++ 1.50 2.00 50 40 230 - - - - 6.3 6.1 5.9 5.6 5.2 4.8 4.2 3.0 - - - -
20 KDS - 235+ 1.50 2.00 50 40 230 - - 4.3 4.2 4.1 4.0 3.9 3.7 3.5 3.3 3.0 2.9 2.3 2.0 1.3 0.5
21 KDS - 312 2.20 3.00 100 100 230 20.0 17.5 14.5 10.5 - - - - - - - - - - - -
22 KDS - 314+ 2.20 3.00 100 100 230 - 19.2 17.9 16.2 14.0 10.5 - - - - - - - - - -
23 KDS - 314+ 2.20 3.00 80 80 230 - 19.2 17.9 16.2 14.0 10.5 - - - - - - - - - -
24 KDS - 318++ 2.20 3.00 80 65 230 - - 13.4 12.6 11.7 10.7 9.2 7.5 4.5 - - - - - - -
25 KDS - 318++ 2.20 3.00 65 50 230 - - 13.4 12.6 11.7 10.7 9.2 7.5 4.5 - - - - - - -
26 KDS - 318+ 2.20 3.00 80 80 230 - - 13.4 12.6 11.7 10.7 9.2 7.5 4.5 - - - - - - -
27 KDS - 325++ 2.20 3.00 65 50 230 - - - 9.2 8.8 8.4 7.9 7.4 7.0 6.4 5.8 4.9 - - - -
28 KDS - 335++ 2.20 3.00 50 40 230 - - - - 5.7 5.5 5.4 5.2 5.0 4.8 4.5 4.3 3.9 3.5 3.0 2.3
29 KDS - 515+ 3.70 5.00 100 100 230 - - - 28.0 24.0 19.0 12.5 - - - - - - - - -
30 KDS - 520+ 3.70 5.00 80 80 230 - 23.8 23.0 22.1 21.0 19.6 17.9 15.8 13.5 11.0 - - - - - -
31 KDS - 527+ 3.70 5.00 80 65 230 - - - - - - 14.3 13.5 12.6 11.6 10.4 9.1 6.8 - - -
16 18 20 22 24 26 28 30 32 34 36 38 40 44 48 52
32 KDS - 1.540+ 1.10 1.50 32 25 230 - - - 2.0 1.9 1.7 1.6 1.45 1.3 1.1 0.9 0.6 - - - -
33 KDS - 246 1.50 2.00 32 25 210 - - - - - - - 3.2 2.9 2.7 2.5 2.2 1.7 0.5 - -
34 KDS - 538+ 3.70 5.00 65 50 230 - 8.4 8.3 8.2 8.1 7.9 7.7 7.5 7.1 6.6 5.8 5.0 4.0 - - -
35 KDS - 550++ 3.70 5.00 50 40 230 - - - - - - - - - - 4.1 3.9 3.7 3.3 2.7 2.0
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
92
PERFORMANCE CHART FOR 'KDS-LV' SERIES, 2 POLE, MONOBLOC PUMPS, AT RATED VOLTAGE,
50Hz FREQUENCY , SINGLE PHASE A.C. POWER SUPPLY
Note:
n LV Denotes - Low Voltage
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
93
PERFORMANCE CHART FOR 'KDS-P' SERIES, 2 POLE, MONOBLOC PUMPS, AT RATED VOLTAGE,
50Hz FREQUENCY , SINGLE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
94
FEATURES TECHNICAL SPECIFICATION
95
PERFORMANCE CHART FOR KAM SERIES, 2 POLE, MONOBLOC PUMPS, AT RATED VOLTAGE,
50 Hz FREQUENCY, SINGLE PHASE A.C. POWER SUPPLY
Note:
n LV Denotes - Low Voltage
n KAM-05 is Also Available With Extended Shaft.
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
96
FEATURES TECHNICAL SPECIFICATION
Wide Voltage Design Head - Up to 26 Metres
The motor is designed to withstand wide voltage variation which reduces motor Capacity - Up to 4.7 LPS
DC burning in case of low/high voltage.
Power Rating - 0.37 to 0.55 kW
(0.5 to 0.75 HP)
HASTI Designed to Prevent Overloading
Lesser chances of motor burning even if the pump operates at lower head than Voltage Range - 180 to 240 Volts ( Single phase)
PAMBA PUZHA recommended as motor does not get overload thus ensures substantial saving from
maintenance cost and breakdown.
except Hasti Pumps
160 to 240 Volts ( Single phase)
SINGLE PHASE Dynamically Balanced Rotating Parts for Hasti Pumps
MONOBLOC PUMPS Minimum vibration protects components from damage during the operation, thus Insulation - B Class
ensures consistent performance over longer time period as concentricity is Protection - IP44
maintained.
PAMBA PUZHA
97
PERFORMANCE CHART FOR 'DC/HASTI/PAMBA PUZHA' SERIES, 2 POLE, MONOBLOC PUMPS, AT RATED VOLTAGE,
50 Hz FREQUENCY,SINGLE PHASE A.C. POWER SUPPLY
Note:
n LV Denotes - Low Voltage
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
98
99
DOMESTIC
PRODUCT RANGE
MINI SERIES
SELF PRIMING PUMPS
100
MINI RANGE
101
FEATURES
JALRAAJ - 1 ULTRA
102
PERFORMANCE CHART FOR MINI RANGE PUMPS, 2 POLE, AT RATED VOLTAGE, 50 Hz FREQUENCY,
SINGLE PHASE A.C. POWER SUPPLY
Note:
n ** ES - Extended Shaft.
n MINI 30C and MINI 50C are also available in three phase.
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
103
TECHNICAL SPECIFICATION
Cathodic Electro Deposition (CED) Coating AARNA - II/ ANAYA - II/ RIAN - II AARNA - I/ ANAYA - I/ RIAN - I
CED is the latest coating technology for corrosion resistance with a uniform
Head Range - 6 to 21 Meters 6 to 30 Meters
coating. It provides 5 times more protection over conventional painting,
resulting in longer life. All major CI parts of Kirloskar pumps coming in contact Capacity Range - 1980 to 680 LPH 2700 to 650 LPH
with the water are CED coated. Power Rating - 0.37 kW / 0.5 HP 0.75 kW / 1.0 HP
104
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
105
JAL JALDAKSH JALHASTI II / JALHASTI I JALTARA II / JALTARA I
SERIES
MINI PUMPS
For Domestic Applications
106
TECHNICAL SPECIFICATION
High Efficiency and Energy Saving Design Head Range - Up to 55 Meters
Innovative design manufactured at state of art plant, delivers optimum efficiency at lower Capacity Range - Up to 4300 LPH
energy consumption resulting in significant cost savings.
Power Rating - 0.37 to 0.75 kW/ 0.5 to 1.0 HP
Wide Voltage Range Phase - Single / Three
The motor is designed to withstand wide voltage variation and reduces chances of motor (Only for JALNAYAK Three Phase Model)
burning due to low/high voltage.
Voltage Range - 180 to 260 Volts (Single Phase)
Cathodic Electro Deposition (CED) Coating 300 to 440 Volts (Three Phase)
CED is the latest coating technology for corrosion resistance with uniform coating, provides 5 (for JALNAYAK Three Phase Model)
times more protection over conventional painting, resulting in longer life. Hydraulic parts of Insulation - B CLASS / F CLASS (Gold Series)
Kirloskar pumps are CED coated
SERIES
ensures the reliability, safety and enhanced life. Motor Body - Aluminium
Enhanced Safety
All electrical parts of the pump are covered, which makes it safer to use.
107
PERFORMANCE CHART FOR JAL SERIES MINI RANGE PUMPS, 2 POLE,
AT RATED VOLTAGE, 50 Hz FREQUENCY, SINGLE PHASE A.C. POWER SUPPLY BRONZE
Power Pipe Size TOTAL HEAD IN METERS
S. Rated
Pump Model Rating (mm) Voltage 6 10 14 18 22 26 28 30 32 34 36 40 41 45 48 50
No.
kW HP SUC. DEL (Volts) DISCHARGE IN LITRES PER HOUR
1 JALHANSA ll 0.37 0.5 25 25 220 2050 1725 1440 1115 790 500 - - - - - - - - - -
2 JALDAKSH 0.75 1.0 25 25 220 3000 2735 2450 2200 1945 1655 1550 1400 1300 1150 1005 750 - - - -
3 JALHANSA l 0.75 1.0 25 25 220 3100 2845 2555 2300 2050 1765 1620 1510 1365 1220 1115 850 - - - -
Note:
n JALNAYAK I and JALNAYAK II are also available in three phase.
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
108
AQUA KNIGHT V-FLOW AQUA TORRENT-10FCL CMS N
109
PERFORMANCE CHART FOR 'AQUA' SERIES, 2 POLE, MONOBLOC PUMPS, AT RATED VOLTAGE,
50 Hz FREQUENCY, SINGLE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
110
111
DOMESTIC
PRODUCT RANGE
JET PUMPS
112
FEATURES TECHNICAL SPECIFICATION
113
PERFORMANCE CHART FOR KJ PUMPS AT RATED VOLTAGE, 50 Hz FREQUENCY,
SINGLE-PHASE AC POWER SUPPLY
Min. Min. Power Rated DEPTH TO LOW WATER LEVEL IN METRES
Sr. Pump Model Jet Well Operating Rating Pipe Size (mm)
Size Pressure Voltage 9 12 15 18 21 24 27 30 33 36 39 42 45 48
No. Twin Type Unit (Volts)
(mm) (Meters) kW HP DEL. PRESS. DIS. DISCHARGE IN LITRES PER HOUR
1 KJ - 05V/H 4T6 100 8 0.37 0.5 32 25 25 210 1920 1680 1320 1020 720 540 360 - - - - - - -
2 KJ - 10V/H 4T3 100 19 0.75 1.0 32 25 25 210 2700 2520 2220 1800 1500 1250 960 660 - - - - - -
3 KJ - 10V 4T6 100 19 0.75 1.0 32 25 25 210 1800 1790 1525 1300 1090 900 725 570 432 300 180 120 - -
4 KJ - 10V/H 5T2 115 19 0.75 1.0 40 32 25 210 3360 3090 2700 2340 1990 1600 1240 1000 - - - - - -
5 KJ - 15V/H 4T6 100 23 1.10 1.5 32 32 25 210 1940 1920 1880 1860 1740 1560 1350 1170 1050 920 810 690 570 480
6 KJ - 15V/H 4T6 110 23 1.10 1.5 32 25 25 210 1896 1884 1860 1764 1584 1356 1152 960 780 648 516 384 264 -
7 KJ - 15V/H 5T2 115 22 1.10 1.5 40 32 25 210 3600 3360 3000 2670 2350 2010 1680 1320 1080 720 - - - -
PACKER TYPE
8 KJ - 10V/H 2P1 50 20 0.75 1.0 32 25 25 210 - 1600 1200 1062 900 540 - - - - - - - -
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
114
115
DOMESTIC
PRODUCT RANGE
116
FEATURES TECHNICAL SPECIFICATION
LIFTER
117
PERFORMANCE CHART FOR 'LIFTER/KSW' SERIES, 2 POLE, SHALLOW WELL PUMPS, AT RATED VOLTAGE,
50 Hz FREQUENCY, SINGLE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
118
119
DOMESTIC
PRODUCT RANGE
120
100
FEATURES TECHNICAL SPECIFICATION
121
PERFORMANCE CHART FOR 'KOSi' SERIES, 2 POLE, OPENWELL SUBMERSIBLE PUMPS,
50 Hz FREQUENCY, SINGLE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
122
FEATURES TECHNICAL SPECIFICATION
KOSi C Constructed with special grade engineering materials, compact designs for ease of
handling and installation.
Insulation
Protection
-
-
PP
IP68
Dynamically Balanced Rotating Parts
SINGLE PHASE OPEN-WELL Minimum vibrations protect components from damages during the operations, thus MATERIAL OF CONSTRUCTION
SUBMERSIBLE PUMPS ensuring consistent performance as concentricity is maintained.
Impeller - Cast Iron / Noryl
Replaceable Wearing Parts Delivery Casing - Cast Iron
All wearing parts within the pumps are easily accessible and replaceable which Motor Body - Cast Iron
WITH CAST IRON MOTOR BODY facilitates ease of maintenance thereby extending the life of the pump.
Shaft - Stainless Steel
Easy Maintainable Designs
Easy maintainable design and better interchangeability of components so that APPLICATIONS
pump can be serviced even at remote locations by semi-skilled technicians.
Ÿ Domestic and community water supply
CED – Cathodic Electro Deposition
Ÿ Gardening and small farm irrigation
CED is the latest coating technology for corrosion resistance with uniform coating. It
provides 5 times more protection over conventional painting, resulting in longer life. Ÿ Water fountains
All major CI parts of Kirloskar pumps coming in contact with the water are CED Ÿ Construction site
coated. Ÿ Water supply to over head tanks
High Efficiency and Energy Saving Design
Innovative design manufactured at state of art plant, delivers optimum efficiency at
lower energy consumption resulting in significant cost savings.
123
PERFORMANCE CHART FOR 'KOSi Cast Iron Motor Body' SERIES, 2 POLE, OPENWELL SUBMERSIBLE PUMPS,
50 Hz FREQUENCY, SINGLE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
124
125
DOMESTIC
PRODUCT RANGE
126
FEATURES TECHNICAL SPECIFICATION
CPBS The pump set features a Thermal Overload Protector that protects the motor from
overloading, shielding of the motor and associated circuit from the effects of fault
Voltage Range
Insulation
-
-
180 to 240 Volts (Single Phase)
B Class
current Protection - IP 44
PRESSURE Tank Size - 24 Litres
Diaphragm Type Pressure Tank
BOOSTING SYSTEM
Diaphragm type pressure tank made from high grade engineering material.
MATERIAL OF CONSTRUCTION
Reliable and Durable Components
Reliable and durable peripheral parts such as Pressure Switch, Standardized Impeller - Stainless Steel
Size of 5 Way Connector, and Italian make NRV and SS hose pipe.
Diffuser - Stainless Steel
Easy Maintainable Designs Motor Body - Aluminum Die Cast
Easy maintainable design and better interchangeability of components so that pump Pump Shaft - Stainless Steel
can be serviced even at remote locations by semi-skilled technicians.
Pump Stage Casing - Stainless Steel
Suction & Delivery Casing - Cast Iron
APPLICATIONS
127
PERFORMANCE CHART FOR 'CPBS' SERIES, PRESSURE BOOSTING SYSTEM, AT RATED VOLTAGE,
50 Hz FREQUENCY, SINGLE PHASE A.C. POWER SUPPLY
Pump Model Power Pipe Size Rated Rated Pressure No. of No. DISCHARGE IN LPM
S. Rating (mm) Current Voltage Range Outlets/ of
Horizontal/ 20 40 60 80 100 120 140
No. (Volts) (kg/cm2) Taps Stages
Vertical Models kW HP SUC. DEL. (Amps) TOTAL HEAD IN METERS
1 CPBS - 52424H / V 0.4 0.6 25 25 5.5 220 1.4 - 2.4 5 2 25 21 17 6 - - -
2 CPBS - 62824H / V 0.6 0.8 25 25 6.5 220 1.8 - 2.8 6 3 35 30 26 16 6 - -
3 CPBS - 73624H / V 0.75 1.0 25 25 7.5 220 2.2 - 3.6 7 4 41 37 33 29 24 18 6
4 CPBS - 84424H / V 1.1 1.5 25 25 8.5 220 2.4 - 4.4 8 5 52 47 43 37 30 24 12
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
128
FEATURES TECHNICAL SPECIFICATION
129
PERFORMANCE OF K-BOOSTER, PRESSURE BOOSTING SYSTEM, AT RATED VOLTAGE,
50 Hz, SINGLE PHASE A.C. POWER SUPPLY
1 Kirloskar K-Booster 0.37 0.5 25 25 3 220 1.4 - 2.4 2050 1655 1400 1150 865 500 360
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
130
FEATURES TECHNICAL SPECIFICATION
131
PERFORMANCE OF STAR GALAXY, PRESSURE BOOSTING SYSTEM, AT RATED VOLTAGE,
50 Hz FREQUENCY, SINGLE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
132
FEATURES TECHNICAL SPECIFICATION
133
PERFORMANCE CHART FOR ‘HI – LIFTER (SINGLE STAGE)’ PUMPS, 50 HZ FREQUENCY,
SINGLE PHASE A.C. POWER SUPPLY
PERFORMANCE CHART FOR ‘HI – LIFTER (MULTI STAGE)’ PUMPS, AT RATED VOLTAGE, 50 HZ FREQUENCY,
SINGLE PHASE A.C. POWER SUPPLY
Note:
n Performance under standard test conditions and may vary on site conditions.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
134
135
BOREWELL SUBMERSIBLE
8 CM,10 CM & 15 CM OIL COOLED PUMPSETS
136
TECHNICAL SPECIFICATION
KP3S The motor is designed to withstand wide voltage variations which reduces the
chances of motor burning at low voltage.
Insulation
Type of Cooling
-
-
F Class
Oil Cooled
Protection - IP68
8 CM BOREWELL Dynamically Balanced Rotating Parts
SUBMERSIBLE PUMPS Minimum vibration protects components from damage during the operation, thus
ensures consistent performance over longer time period as concentricity is MATERIAL OF CONSTRUCTION
maintained.
Pump Housing - Stainless Steel
Design to Prevent Overloading Pump Shaft - Stainless Steel
Lesser chances of motor burning even if the pump operates at lower head than Motor Housing - Stainless Steel
recommended as motor does not get overload thus ensures substantial saving from
Motor Shaft - Stainless Steel
maintenance cost and breakdown.
Pump Bushes - LTB
Lightweight and Compact Design Impeller - Noryl
Constructed with special grade engineering materials, compact designs for ease of Diffuser - Noryl
handling and installation. NRV - Cast Iron
Suction - Cast Iron
Splined Shaft
Splined shaft made from cold extrusion technology with high surface strength Bearing type - Ball bearing
provides better life and good axiality.
CO APPLICATIONS
O LE D Flatter Efficiency Curve
Minimum variations in efficiency during entire operating range increases the utility of
pumpset for variable conditions. Ÿ Domestic and community water supply
Ÿ Rural water supply
Suitable for Horizontal Applications Ÿ Gardening and small farm irrigation
Motor with ball bearings are suitable for horizontal installation for water transfer at
Ÿ Construction Site
high heads in residential complexes.
Ÿ Water supplies for high rise building
137
PERFORMANCE CHART FOR 8 CM BOREWELL SUBMERSIBLE PUMPSETS - KP3S SERIES
AT RATED VOLTAGE OF 220 VOLTS - SINGLE PHASE, 50 Hz FREQUENCY, AC SUPPLY
138
TECHNICAL SPECIFICATION
High Efficiency and Energy Saving Design Head Range - Up to 251 Metres
Innovative design manufactured at state of art plant, delivers optimum efficiency at
lower energy consumption resulting in significant cost savings. Discharge Range - Up to 350 LPM
Power Rating - 0.37 to 3.70 kW (0.5 to 5.0 HP)
Wide Voltage Design Voltage Range - 150 to 240 Volts (Single Phase)
The motor is designed to withstand wide voltage variations which reduces the
KU4 chances of motor burning at low voltage. Insulation -
280 to 440 Volts (Three Phase)
F Class
Dynamically Balanced Rotating Parts Type of Cooling - Oil Cooled
10 CM BOREWELL Minimum vibration protects components from damage during the operation, thus Protection - IP68
SUBMERSIBLE PUMPS ensures consistent performance over longer time period as concentricity is
maintained.
MATERIAL OF CONSTRUCTION
Design to Prevent Overloading
Pump Housing - Stainless Steel
Lesser chances of motor burning even if the pump operates at lower head than
recommended as motor does not get overload thus ensures substantial saving from Pump Shaft - Stainless Steel
maintenance cost and breakdown. Motor Housing - Stainless Steel
Motor Shaft - Stainless Steel
Lightweight and Compact Design Motor Bearing - Ball Bearing
Constructed with special grade engineering materials, compact designs for ease of
Pump Bushes - NBR
handling and installation.
Impeller - Noryl
Splined Shaft Diffuser - Noryl
Splined shaft made from cold extrusion technology with high surface strength NRV - Stainless Steel
provides better life and good axiality. Suction - Stainless Steel
CO Flatter Efficiency Curve
O LE D Minimum variations in efficiency during entire operating range increases the utility of
APPLICATIONS
pumpset for variable conditions.
Ÿ Domestic and community water supply
Suitable for Horizontal Applications
Motor with ball bearings are suitable for horizontal installation for water transfer at Ÿ Rural water supply
high heads in residential complexes. Ÿ Gardening and small farm irrigation
Ÿ Construction Site
Ÿ Water supplies for high rise building
139
PERFORMANCE CHART FOR 10 CM BOREWELL SUBMERSIBLE PUMPSETS - KU4 - 02 SERIES AT RATED
VOLTAGE OF 220 VOLTS - SINGLE PHASE / 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
NA
NA
NA
NA
140
PERFORMANCE CHART FOR 10 CM BOREWELL SUBMERSIBLE PUMPSETS - KU4 - 07 SERIES AT RATED
VOLTAGE OF 220 VOLTS - SINGLE PHASE / 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
NA
NA
141
PERFORMANCE CHART FOR 10 CM BOREWELL SUBMERSIBLE PUMPSETS - KU4 - 15 SERIES AT RATED
VOLTAGE OF 220 VOLTS - SINGLE PHASE / 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
NA
NA
142
TECHNICAL SPECIFICATION
High Efficiency And Energy Saving Design Head Range - Up to 169 Metres
Innovative design manufactured at state of art plant, delivers optimum efficiency at Discharge Range - Up to 350 LPM
lower energy consumption resulting in significant cost savings.
Power Rating - 0.37 to 2.2 kW
(0.5 to 3.0 HP)
KP4 Wide Voltage Design
The motor is designed to withstand wide voltage variations which reduces the
Voltage Range - 150 to 240 Volts (Single Phase)
143
PERFORMANCE CHART FOR 10 CM BOREWELL SUBMERSIBLE PUMPSETS - "KP4 JALRAAJ UVA"
OIL FILLED SERIES AT RATED VOLTAGE OF 220 VOLTS - SINGLE PHASE, 50 HZ FREQUENCY, AC SUPPLY
m3/h
32
32
32
32
32
32
m3/h
m3/h
144
Higher Efficiencies and Lower Power Consumption Head Range - Up to 325 Metres
Innovative motor designs with the advantage of better lubricating and cooling Discharge Range - Up to 530 LPM
properties of oil deliver unmatched performances with 4 to 5% higher efficiencies at
less power consumption, having considerable savings in electricity bills. Power Rating - 2.2 to 15.0 kW (3.0 to 20.0 HP)
Voltage Range - 250 to 440 Volts (Three Phase)*
No Health Hazard
Inefficacious on health, all the motors are prefilled with non-toxic, non-hazardous
purified paraffin oil, which has no fear of health hazard
Unmatched Warranty
Inscription of Indian International product with an unmatched 24-month warranty 145
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS - KU6i HHN 210 SERIES WITH
OIL FILLED MOTORS AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS - KU6i HHN 240 SERIES WITH
OIL FILLED MOTORS AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
146
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS - KU6i HHN 300 SERIES WITH
OIL FILLED MOTORS AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS - KU6i HHN 350 SERIES WITH
OIL FILLED MOTORS AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
147
148
BOREWELL SUBMERSIBLE
8 CM & 10 CM WATER COOLED PUMPSET
149
TECHNICAL SPECIFICATION
Wide Voltage Design Head Range - Up to 131 Metres
The motor is designed to withstand wide voltage variations which reduces the
Discharge Range - Up to 95 LPM
chances of motor burning at low voltage.
Power Rating - 0.37 to 1.1 kW (0.5 to 1.5 HP)
Design to Prevent Overloading Voltage Range - 160 to 240 Volts (Single Phase)
Lesser chances of motor burning even if the pump operates at lower head than Insulation - B Class
KS3 recommended as motor does not get overload thus ensures substantial saving from
maintenance cost and breakdown.
Type of Cooling - Water Cooled
Protection - IP68
8 CM BOREWELL High Efficiency and Energy Saving Design
SUBMERSIBLE PUMPS Innovative design manufactured at state of art plant, delivers optimum efficiency at
lower energy consumption resulting in significant cost savings. MATERIAL OF CONSTRUCTION
150
PERFORMANCE CHART FOR 8 CM BOREWELL SUBMERSIBLE PUMPSETS - KS3 HIGH HEAD SERIES
AT RATED VOLTAGE OF 220 VOLTS - SINGLE PHASE, 50 HZ FREQUENCY, AC SUPPLY
0 30 40 50 57 65 75 95
0.0 1.8 2.4 3.0 3.4 3.9 4.5 5.7
KS3 PURNA 60 - 0505 0.37 0.50 5 32 4.4 22 19 17 15 13 12 10 5
KS3 PURNA 60 - 0808 0.55 0.75 8 32 6.0 34 30 26 23 21 18 15 8
KS3 PURNA 60 - 1010 0.75 1.00 10 32 7.8 43 37 33 29 26 23 19 10
KS3 PURNA 60 - 1312 0.93 1.25 12 32 9.7 52 44 40 35 31 28 23 12
KS3 PURNA 60 - 1515 1.1 1.50 15 32 10.5 65 56 50 44 39 35 29 15
151
TECHNICAL SPECIFICATION
Wide Voltage Design Head Range - Up to 520 Metres
The motor is designed to withstand wide voltage variations which reduces the Discharge Range - Up to 420 LPM
chances of motor burning at low voltage.
Power Rating - 0.37 to 5.5 kW (0.5 to 7.5 HP)
High Efficiency and Energy Saving Design Voltage Range - 160 to 240 Volts (Single Phase)
KS4 Innovative design manufactured at state of art plant, delivers optimum efficiency at
lower energy consumption resulting in significant cost savings. Insulation -
280 to 440 Volts (Three Phase)
B Class
Type of Cooling - Water Cooled
10 CM BOREWELL Dynamically Balanced Rotating Parts
Protection - IP68
SUBMERSIBLE PUMPS Minimum vibration protects components from damage during the operation, thus
ensures consistent performance over longer time period as concentricity is
maintained. MATERIAL OF CONSTRUCTION
Longer and Trouble Free Life Pump Housing - Stainless Steel
High grade engineering materials like Graded Cast Iron Components, Stainless Steel
Pump Shaft - Stainless Steel
Shaft, Noryl Impellers, Bronze Bushes, Heavy duty Carbon + SS Thrust Plate, 99.9 %
Electro Grade Copper Rotor and Winding Wires for longer and trouble free life. Motor Housing - Stainless Steel
Motor Shaft - Stainless Steel
Advanced Water Cooled Motors Designs Thrust Bearing - Carbon + Stainless Steel
The motor is filled with potable water, protects from overheating and facilitates Pump / Motor Bushes - NBR / LTB
smoother and trouble free operation for the years.
Impeller - Noryl
Wide Voltage Motor Designs with Copper Rotor Diffuser - Noryl
Motors are designed with extra overload capacities, more water spaces and NRV - Cast Iron
engineered with 99.9% pure Electro Grade Copper rotor performs well in low voltage Suction - Cast Iron
with minimum discharge drops and suitable for wide voltage applications.
Cooled
CED – Cathodic Electro Deposition APPLICATIONS
CED is the latest coating technology for corrosion resistance with uniform coating,
provides 5 times more protection over conventional painting, resulting in longer life. Ÿ Domestic and community water supply
All major CI parts of Kirloskar pumps coming in contact with the water are CED Ÿ Rural water supply
coated.
Ÿ Gardening and small farm irrigation
Ÿ Construction Site
Ÿ Water supplies for high rise building
152
PERFORMANCE CHART FOR 10 CM BOREWELL SUBMERSIBLE PUMPSETS - KS4 - AN SERIES AT RATED
VOLTAGE OF 220 VOLTS SINGLE PHASE / 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
NA
NA
153
PERFORMANCE CHART FOR 10 CM BOREWELL SUBMERSIBLE PUMPSETS - KS4 - C SERIES AT RATED VOLTAGE OF
220 VOLTS SINGLE PHASE / 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
1
2
3
4
5
6
7
8
9
10
11
12
PERFORMANCE CHART FOR 10 CM BOREWELL SUBMERSIBLE PUMPSETS - KS4 - D SERIES AT RATED VOLTAGE OF
220 VOLTS SINGLE PHASE / 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
154
PERFORMANCE CHART FOR 10 CM BOREWELL SUBMERSIBLE PUMPSETS - KS4 - E SERIES AT RATED
VOLTAGE OF 220 VOLTS SINGLE PHASE / 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
155
PERFORMANCE CHART FOR 10 CM BOREWELL SUBMERSIBLE PUMPSETS - KS4 - H SERIES AT RATED
VOLTAGE OF 220 VOLTS SINGLE PHASE / 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
156
PERFORMANCE CHART FOR 10 CM BOREWELL SUBMERSIBLE PUMPSETS - KS4 - HF SERIES AT RATED
VOLTAGE OF 220 VOLTS SINGLE PHASE / 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
PERFORMANCE CHART FOR 10 CM BOREWELL SUBMERSIBLE PUMPSETS - KS4 - BIGFLOW SERIES RATED
VOLTAGE OF 220 VOLTS - SINGLE PHASE, 50 HZ FREQUENCY, AC SUPPLY
PERFORMANCE CHART FOR 10 CM BOREWELL SUBMERSIBLE PUMPSETS - KS4 - ‘B’ HIGH HEAD SERIES
RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
3PH
157
TECHNICAL SPECIFICATION
Wide Voltage Range Operability Head Range - Up to 165 Metres
The motor is designed to withstand wide voltage variations from 180 - 240 Volts Discharge Range - Up to 105 LPM
which reduces the chances of motor burning at low voltage.
Power Rating - 0.37 to 1.5 kW
(0.5 to 2.0 HP)
High Efficiency and Energy-saving Design Voltage Range - 180 to 240 Volts (Single Phase)
NEO Innovative design manufactured at state of art plant, delivers optimum efficiency at
lower energy consumption resulting in significant cost savings.
Type of Cooling
Insulation
-
-
Water Cooled
B Class
10 CM BOREWELL
Protection - IP68
Dynamically Balanced Rotating Parts
SUBMERSIBLE PUMPS
Minimum vibration protects components from damage during the operation, thus
ensures consistent performance over longer time period as concentricity is MATERIAL OF CONSTRUCTION
maintained.
Pump Housing - Stainless Steel
Longer and Trouble Free Life Pump Shaft - Stainless Steel
High grade engineering materials like Graded Cast Iron Components, Stainless Motor Housing - Stainless Steel
Steel Shaft, Noryl Impellers, Bronze Bushes, Heavy duty Carbon + SS Thrust Motor Shaft - Stainless Steel
Plate, 99.9 % pure Copper Winding Wires for longer and trouble free life. Thrust Bearing - Carbon + Stainless Steel
Pump/Motor Bushes - NBR / LTB
Advanced Water Cooled Motors Designs Impeller - Noryl
The motor is filled with potable water, protects from overheating and facilitates Diffuser - Noryl
smoother and a trouble free operation for the years.
NRV - Cast Iron
Suction - Cast Iron
Sand Fighter Designs
Cooled Innovative Sand Fighter Design restricts the entry of sand in motors,protects
bushes of pump and motor thus pumpset perform well in sandy borewells and APPLICATIONS
increase life of pumpset.
Ÿ Domestic and community water supply
CED - Cathodic Electro Deposition Coating Ÿ Rural water supply
CED is the latest coating technology for corrosion resistance with uniform coating, Ÿ Gardening and small farm irrigation
provides 5 times more protection over conventional painting, resulting in longer Ÿ Construction site
life. All major CI parts of Kirloskar pumps coming in contact with the water are Ÿ Water supplies for high rise building
CED coated.
158
PERFORMANCE CHART FOR 10 CM BOREWELL SUBMERSIBLE PUMPSETS - “NEO SERIES”
AT RATED VOLTAGE OF 220 VOLTS SINGLE PHASE, 50 HZ FREQUENCY, AC SUPPLY
NEO 25 SERIES
Power Rating Outlet Rated LPM 0 6 13 20 25 34 40 47
No of Current
S. No. Pump Model Size
Stages
kW HP (mm) m /h3
0 0.4 0.8 1.3 1.5 2.1 2.5 2.9
1 NEO 25 - 0510 0.37 0.50 10 32 5.8 67 65 64 60 48 45 30 14
METERS
HEAD IN
2 NEO 25 - 1020 0.75 1.00 20 32 8.2 134 130 128 120 97 90 60 27
3 NEO 25 - 1525 1.10 1.50 25 32 11.5 168 163 160 150 121 112 75 34
NEO 30 SERIES
Power Rating Outlet Rated LPM 0 6 18 24 30 36 42 48
No of Current
S. No. Pump Model Size
Stages
kW HP (mm) m /h3
0 0.4 1.1 1.4 1.8 2.2 2.5 2.9
1 NEO 30 - 0507 0.37 0.50 7 32 5.8 49 46 44 42 39 35 30 25
HEAD IN METERS
2 NEO 30 - 1014 0.75 1.00 14 32 8.2 98 91 88 84 77 70 60 50
3 NEO 30 - 1016 0.75 1.00 16 32 8.2 112 104 101 96 88 80 69 58
4 NEO 30 - 1518 1.10 1.50 18 32 11.5 126 117 113 108 99 90 77 65
5 NEO 30 - 1520 1.10 1.50 20 32 11.5 140 130 126 120 110 100 86 72
6 NEO 30 - 2025 1.50 2.00 25 32 15.0 175 163 158 150 138 125 108 90
NEO 35 SERIES
Power Rating Outlet Rated LPM 0 12 23 28 35 42 58 64
No of Current
S. No. Pump Model Size
Stages
kW HP (mm) m3/h 0 0.7 1.4 1.7 2.1 2.5 3.5 3.8
1 NEO 35 - 1012 0.75 1.00 12 32 8.2 89 83 77 71 61 49 35 15
HEAD IN METERS
2 NEO 35 - 1515 1.10 1.50 15 32 11.5 111 104 96 89 76 61 44 19
3 NEO 35 - 1516 1.10 1.50 16 32 11.5 119 110 103 95 81 65 47 20
4 NEO 35 - 1517 1.10 1.50 17 32 11.5 126 117 109 100 87 70 50 22
5 NEO 35 - 2022 1.50 2.00 22 32 15.0 163 152 141 130 112 90 65 28
NEO 60 SERIES
Power Rating Outlet Rated LPM 0 15 30 45 60 72 90 105
No of Current
S. No. Pump Model Size
Stages
kW HP (mm) m /h3
0 0.9 1.8 2.7 3.6 4.3 5.4 6.3
1 NEO 60 - 1008 0.75 1.00 8 32 8.2 62 59 56 50 41 32 18 6
HEAD IN METERS
159
160
SUBMERSIBLE
PRODUCT RANGE
161
FEATURES TECHNICAL SPECIFICATION
Wide Voltage Motor Designs with Copper Rotor Head Range -
Up to 276 Metres
Motors are designed with extra overload capacities, more water spaces and Discharge Range -
Up to 1540 LPM
engineered with 99.9% pure Electro Grade Copper rotor performs well in low voltage Power Rating -
1.5 to 18.5 kW (2 to 25 HP)
with minimum discharge drops and suitable for wide voltage applications.
Voltage Range -
160 to 240 Volts (Single Phase)
200 to 440 Volts (Three Phase)*
KS6 Sand Fighter Designs
Innovative Sand Fighter Design restricts the entry of sand in motors,protects bushes
of pump and motor thus pumpset perform well in sandy borewells and increase life of
Insulation - B Class
Type of Cooling - Water Cooled
15 CM BOREWELL
pumpset. Protection - IP68
SUBMERSIBLE PUMPS *Under ideal condition with suitable cable size.
Dynamically Balanced Rotating Parts
Minimum vibration protects components from damage during the operation, thus
ensures consistent performance over longer time period as concentricity is MATERIAL OF CONSTRUCTION
maintained.
Impeller - Stainless Steel / Noryl
Longer and Trouble Free Life Diffuser - Cast Iron / Noryl
High grade engineering materials like Graded Cast Iron Components, Stainless Steel Bowl/Stage casing - Cast Iron
Shaft, Noryl/Stainless Steel Impellers, Bronze Bushes, Heavy duty Carbon + SS
Pump Shaft - Stainless Steel
Thrust Plate, 99.9 % Electro Grade Copper Rotor and Winding Wires for longer and
trouble free life. Motor Housing - Stainless Steel
Motor Shaft - Stainless Steel
High Efficiency and Energy Saving Design Finished Rotor - Copper
Innovative design manufactured at state of art plant, delivers optimum efficiency at NRV - Cast Iron
lower energy consumption resulting in significant cost savings.
Suction - Cast Iron
CED – Cathodic Electro Deposition Pump / Motor Bushes - NBR / LTB
CED is the latest coating technology for corrosion resistance with uniform coating, Thrust Bearing - Carbon + SS
provides 5 times more protection over conventional painting, resulting in longer life.
Cooled
All major CI parts of Kirloskar pumps coming in contact with the water are CED
coated. APPLICATIONS
Ÿ Irrigation in horticulture & agriculture
Design to Prevent Overloading
Lesser chances of motor burning even if the pump operates at lower head than Ÿ Domestic and community water supply
recommended as motor does not get overload thus ensures substantial saving from Ÿ Sprinkler and drip irrigation
maintenance cost and breakdown. Ÿ Rural water supply
Ÿ Ground water supply to water works
Glycol-mixed Water
Motors filled with specially developed Glycol mixed water to improve the anti-freezing
properties of motor and prevent corrosion.
162
RADIAL FLOW PUMPS
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS - KS6-180 SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Power Rating Outlet Rated Current LPM
No. of (ampere) 0 60 120 160 180 240 270 300
S. No. Model Size
kW HP Stages
(mm) 3Ø m /h 3
0.0 3.6 7.2 9.6 10.8 14.4 16.2 18.0
1 KS6 180 - 0205 1.5 2.0 5 50 4.5 48 46 41 36 35 24 18 9
2 KS6 180 - 0206 1.5 2.0 6 50 4.5 57 55 49 43 42 29 21 11
3 KS6 180 - 0408 3.0 4.0 8 50 8.5 76 74 65 57 56 39 28 15
4 KS6 180 - 0409 3.0 4.0 9 50 8.5 86 83 74 65 63 44 32 17
Head in Meters
5 KS6 180 - 0410 3.0 4.0 10 50 8.5 95 92 82 72 70 48 35 18
6 KS6 180 - 0411 3.0 4.0 11 50 8.5 105 101 90 79 77 53 39 20
7 KS6 180 - 0512 3.7 5.0 12 50 10.0 114 110 98 86 84 58 42 22
8 KS6 180 - 0613 4.5 6.0 13 50 12.0 124 120 106 93 91 63 46 24
9 KS6 180 - 0614 4.5 6.0 14 50 12.0 133 129 114 100 98 68 49 26
10 KS6 180 - 0615 4.5 6.0 15 50 12.0 143 138 123 108 105 73 53 28
11 KS6 180 - 0816 5.5 7.5 16 50 14.5 153 147 131 115 112 77 56 29
12 KS6 180 - 0820 5.5 7.5 20 50 14.5 191 184 163 143 140 97 70 37
13 KS6 180 - 1024 7.5 10.0 24 50 19.5 229 221 196 172 168 116 84 44
14 KS6 180 - 1330 9.3 12.5 30 50 25.0 286 276 245 215 210 145 105 55
Meters
5 KS6C' - 0808 5.5 7.5 8 50 14.5 91 88 84 80 71 56 44 22
6 KS6C' - 0809 5.5 7.5 9 50 14.5 102 100 95 90 80 63 50 25
7 KS6C' - 0810 5.5 7.5 10 50 14.5 113 111 106 100 89 69 56 28
8 KS6C' - 1011 7.5 10.0 11 50 19.5 125 122 116 110 98 76 61 31
in
9 KS6C' - 1012 7.5 10.0 12 50 19.5 136 133 127 120 107 83 67 33
Head
10 KS6C' - 1313 9.3 12.5 13 50 25.0 147 144 137 130 116 90 72 36
11 KS6C' - 1315 9.3 12.5 15 50 25.0 170 166 158 150 133 104 83 42
12 KS6C' - 1516 11.0 15.0 16 50 29.0 181 177 169 160 142 111 89 44
13 KS6C' - 1518 11.0 15.0 18 50 29.0 204 199 190 180 160 125 100 50
14 KS6C' - 1820 13.0 17.5 20 50 34.0 227 221 211 200 178 139 111 56
15 KS6C' - 2024 15.0 20.0 24 50 39.0 272 265 253 240 213 167 133 67
163
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS KS6C SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Meters
2 KS6D - 0505 3.7 5.0 5 65 10 64 59 56 53 49 45 39 23
3 KS6D - 0806 5.5 7.5 6 65 14.5 77 71 68 64 59 54 47 28
4 KS6D - 1008 7.5 10.0 8 65 19.5 103 95 90 85 79 72 63 38
in
5 KS6D - 1310 9.3 12.5 10 65 25 128 119 113 106 98 89 78 47
6 KS6D - 1512 11.0 15.0 12 65 29 154 143 135 128 118 107 94 56
Head
7 KS6D - 1814 13.0 17.5 14 65 34 180 166 158 149 137 125 109 66
8 KS6D - 2016 15.0 20.0 16 65 39 206 190 180 170 157 143 125 75
MIX FLOW PUMPS
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS (MIX FLOW) - KS6EA SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Power Rating Outlet Rated Current LPM 0 240 360 480 600 720 840 900
No of (Ampere)
S. No. Pump Model Size
Stages
kW HP (mm) 3PH m /h3
0.0 14.4 21.6 28.8 36.0 43.2 50.4 54.0
1 KS6EA - 0808 5.5 7.5 8 80 14.5 66 58 51 43 33 23 12 7
Head in Meters
164
MIX FLOW PUMPS
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS (MIX FLOW) - KS6F SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Power Rating Outlet Rated Current LPM 0 400 500 600 700 800 900 1000
No of (Ampere)
S. No. Pump Model Size
Stages
kW HP (mm) 3PH m /h3
0.0 24.0 30.0 36.0 42.0 48.0 54.0 60.0
1 KS6F - 0503 3.7 5.0 3 80 10 39 29 26 23 21 18 15 10
Meters
2 KS6F - 0604 4.5 6.0 4 80 12 51 39 35 31 27 23 19 13
3 KS6F - 0805 5.5 7.5 5 80 14.5 64 48 43 38 33 29 24 17
4 KS6F - 1006 7.5 10.0 6 80 19.5 77 58 52 46 40 35 29 20
in
5 KS6F - 1308 9.3 12.5 8 80 25 103 77 69 61 53 47 39 27
6 KS6F - 1509 11 15.0 9 80 29 116 87 78 69 60 53 44 30
Head
7 KS6F - 1811 13 17.5 11 80 34 141 106 95 84 73 64 53 37
8 KS6F - 2013 15 20.0 13 80 39 167 126 113 100 87 76 63 43
MIX FLOW PUMPS
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS (MIX FLOW) - KS6G SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Power Rating Outlet Rated Current LPM 0 140 240 480 720 840 960 1200
No of (Ampere)
S. No. Pump Model Size
Stages
kW HP (mm) 3PH m /h3
0.0 8.4 14.4 28.8 43.2 50.4 57.6 72.0
1 KS6G - 0502R 3.7 5.0 2 100 10.0 25 24 22 20 16 15 12 7
Meters
2 KS6G - 0603R 4.5 6.0 3 100 12.0 38 36 33 30 24 22 18 10
3 KS6G - 0804R 5.5 7.5 4 100 14.5 51 48 44 41 33 29 24 13
4 KS6G - 1005R 7.5 10.0 5 100 19.5 64 60 56 51 41 36 30 16
in
5 KS6G - 1306R 9.3 12.5 6 100 25.0 76 72 67 61 49 44 36 20
6 KS6G - 1507R 11.0 15.0 7 100 29.0 89 84 78 71 57 51 42 23
Head
7 KS6G - 1808R 13.0 17.5 8 100 34.0 102 96 89 81 65 58 48 26
8 KS6G - 2010R 15.0 20.0 10 100 39.0 127 120 111 101 81 73 60 33
MIX FLOW PUMPS
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS (MIX FLOW) - KS6J SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Power Rating Outlet Rated Current LPM 0 340 540 740 940 1140 1340 1540
No of (Ampere)
S. No. Pump Model Size
Stages
kW HP (mm) 3PH m /h3
0.0 20.4 32.4 44.4 56.4 68.4 80.4 92.4
1 KS6J - 0803 5.5 7.5 3 100 14.5 36 34 31 28 24 20 16 11
Head in Meters
165
FEATURES TECHNICAL SPECIFICATION
Wide Voltage Motor Designs with Copper Rotor Head Range - Up to 81 Metres
Motors are designed with extra overload capacities, more water spaces and Discharge Range - Up to 2100 LPM
engineered with 99.9% pure Electro Grade Copper rotor performs well in low voltage Power Rating - 4.5 to 18.5 kW (6 to 25 HP)
with minimum discharge drops and suitable for wide voltage applications.
Voltage Range - 280 to 440 Volts (Three Phase)
Glycol-mixed Water
Motors filled with specially developed Glycol mixed water to improve the anti-freezing
properties of motor and prevent corrosion.
166
PERFORMANCE CHART FOR 17.5 CM BOREWELL SUBMERSIBLE PUMPSETS - KS7P-'A' SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Power Rating Outlet Rated Current LPM 0 900 1000 1100 1200 1300 1400 1500 1600
No of (Ampere)
S. No. Pump Model Size
Stages
kW HP (mm) 3PH m3/h 0 54 60 66 72 78 84 90 96
1 KS7P - 0602 4.5 6.0 2 100 12.0 26 19 18 16 15 14 11 9 6
HEAD IN METERS
2 KS7P - 0803 5.5 7.5 3 100 14.5 39 28 26 25 23 20 17 14 9
3 KS7P - 1004 7.5 10.0 4 100 19.5 52 38 35 33 30 27 22 18 12
4 KS7P - 1305 9.3 12.5 5 100 25.0 65 47 44 41 38 34 28 23 15
5 KS7P - 1506 11.0 15.0 6 100 29.0 78 56 53 49 46 41 34 28 18
6 KS7P - 1807 13.0 17.5 7 100 34.0 91 66 62 57 53 48 39 32 21
7 KS7P - 2008 15.0 20.0 8 100 39.0 104 75 70 66 61 54 45 37 24
METERS
HEAD IN
2 KS7P - 1304 9.3 12.5 4 100 25.0 60 43 41 39 34 27 23 19 14
3 KS7P - 1505 11.0 15.0 5 100 29.0 75 54 51 49 43 34 29 24 18
4 KS7P - 2007 15.0 20.0 7 100 39.0 104 75 72 68 60 47 40 33 25
167
PERFORMANCE CHART FOR 17.5 CM BOREWELL SUBMERSIBLE PUMPSETS - KS7P-'C' SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Power Rating Outlet Rated Current LPM 0 600 800 1000 1200 1400 1600 1800 1850
No of (Ampere)
S. No. Pump Model Size
Stages
kW HP (mm) 3PH 3
m /h 0 36 48 60 72 84 96 108 111
1 KS7P - 0802 5.5 7.5 2 100 14.5 33 27 25 23 21 18 14 9 7
METERS
HEAD IN
2 KS7P - 1303 9.3 12.5 3 100 25.0 49 41 38 34 31 26 21 13 11
3 KS7P - 1504 11.0 15.0 4 100 29.0 66 54 50 46 42 35 28 18 14
4 KS7P - 2506 18.5 25.0 6 100 48.0 99 81 75 68 62 53 41 26 21
METERS
HEAD IN
1 KS7C - 1002 7.5 10.0 2 100 19.5 34 27 25 23 21 19 15 13 11
2 KS7C - 1503 11.0 15.0 3 100 29.0 52 40 37 34 32 28 23 20 16
3 KS7C - 2004 15.0 20.0 4 100 39.0 69 53 49 45 43 37 31 27 21
168
PERFORMANCE CHART FOR 17.5 CM BOREWELL SUBMERSIBLE PUMPSETS - KS7 SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
HEAD IN METERS
2 KS7P - 1302 9.3 12.5 2 100 25.0 34 - 28 27 26 25 24 23 22 20 19 17 15
3 KS7C - 0802 5.5 7.5 2 100 14.5 30 - 26 25 24 23 22 21 19 17 16 - -
4 KS7C - 1303 9.3 12.5 3 100 25.0 46 40 38 37 36 34 33 31 29 26 23 - -
5 KS7C - 1804 13.0 17.5 4 100 34.0 61 53 51 49 47 45 44 41 39 35 31 - -
169
FEATURES
Wide Voltage Motor Designs with Copper Rotor Head - Up to 270 Metres
Motors are designed with extra overload capacities, more water spaces and Discharge Range - Up to 2700 LPM
engineered with 99.9% pure Electro Grade Copper rotor performs well in low voltage Power Rating - 4.5 to 45 kW / 6 to 60 HP
with minimum discharge drops and suitable for wide voltage applications.
Voltage Range - 280 to 440 Volts (Three Phase)
Sand Fighter Designs Insulation - B Class
KS8 Innovative Sand Fighter Design restricts the entry of sand in motors,protects bushes
of pump and motor thus pumpset perform well in sandy borewells and increase life of
Type of Cooling
Protection
-
-
Water Cooled
IP68
pumpset.
20 CM BOREWELL
SUBMERSIBLE PUMPS
Dynamically Balanced Rotating Parts
Minimum vibration protects components from damage during the operation, thus Impeller - Stainless Steel
ensures consistent performance over longer time period as concentricity is
Diffuser Casing/Bowl - Cast Iron
maintained.
Diffuser - Cast Iron
Longer and Trouble Free Life Pump Shaft - Stainless Steel
High grade engineering materials like Graded Cast Iron Components, Stainless Steel Motor Body - Stainless Steel
Shaft, Stainless Steel Impellers, Bronze Bushes, Heavy duty Carbon + SS Thrust Motor Shaft - Stainless Steel
Plate, 99.9 % Electro Grade Copper Rotor and Winding Wires for longer and trouble
Finished Rotor - Copper
free life.
NRV - Cast Iron
High Efficiency and Energy Saving Design Suction - Cast Iron
Innovative design manufactured at state of art plant, delivers optimum efficiency at Pump / Motor Bushes - NBR / LTB
lower energy consumption resulting in significant cost savings. Thrust Bearing - Carbon + SS
CED – Cathodic Electro Deposition
CED is the latest coating technology for corrosion resistance with uniform coating, APPLICATIONS
provides 5 times more protection over conventional painting, resulting in longer life.
Cooled • Irrigation in horticulture & agriculture
All major CI parts of Kirloskar pumps coming in contact with the water are CED
coated. • Domestic and community water supply
• Sprinkler and drip irrigation
Design to Prevent Overloading • Rural water supply
Lesser chances of motor burning even if the pump operates at lower head than
• Ground water supply to water works
recommended as motor does not get overload thus ensures substantial saving from
maintenance cost and breakdown.
Glycol-mixed Water
Motors filled with specially developed Glycol mixed water to improve the anti-freezing
properties of motor and prevent corrosion.
170
PERFORMANCE CHART FOR 20 CM BOREWELL SUBMERSIBLE PUMPSETS (RADIAL FLOW) KS8D AT RATED VOLTAGE OF
415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
Power Rating Outlet Rated LPM 0 300 400 500 600 700 800 950
No of
S. No. Pump Model Size Current
Stages (Ampere)
kW HP (mm) 3
m /h 0.0 18.0 24.0 30.0 36.0 42.0 48.0 57.0
Meters
in
Head
PERFORMANCE CHART FOR 20 CM BOREWELL SUBMERSIBLE PUMPSETS (RADIAL FLOW) KS8E AT RATED VOLTAGE OF
415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
Power Rating Outlet Rated LPM 0 240 360 480 650 720 840 960
No of
S. No. Pump Model Size Current
Stages (Ampere)
kW HP (mm) 3
m /h 0 14.4 21.6 28.8 39.0 43.2 50.4 57.6
10.0
15.0
Meters
17.5
20.0
25.0
in
30.0
35.0
Head
40.0
45.0
50.0
171
PERFORMANCE CHART FOR 20 CM BOREWELL SUBMERSIBLE PUMPSETS (MIX FLOW) KS8F AT RATED VOLTAGE OF
415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
Power Rating Outlet Rated LPM 0 700 900 1100 1300 1500 1700 1900
No of
S. No. Pump Model Size Current
Stages (Ampere)
kW HP (mm) 3
m /h 0.0 42.0 54.0 66.0 78.0 90.0 102.0 114.0
Meters
in
Head
PERFORMANCE CHART FOR 20 CM BOREWELL SUBMERSIBLE PUMPSETS (MIX FLOW) KS8G AT RATED VOLTAGE OF
415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
Power Rating Outlet Rated LPM 0 500 800 1000 1200 1400 1500 1600
No of
S. No. Pump Model Size Current
Stages (Ampere)
kW HP (mm) 3
m /h 0.0 30.0 48.0 60.0 72.0 84.0 90.0 96.0
1 KS8G - 1303 9.3 12.5 3 100 25.0 58 49 43 39 35 27 23 19
2 KS8G - 1804 13.0 17.5 4 100 34.0 77 66 58 52 46 36 31 25
Meters
3 KS8G - 2005 15.0 20.0 5 100 39.0 96 82 72 65 58 45 38 32
4 KS8G - 2506 18.5 25.0 6 100 48.0 115 99 87 78 69 54 46 38
5 KS8G - 3007 22.0 30.0 7 100 57.0 135 115 101 91 81 63 54 44
in
6 KS8G - 3508 26.0 35.0 8 100 66.0 154 132 116 104 92 72 61 51
7 KS8G - 4009 30.0 40.0 9 100 76.0 173 148 130 117 104 81 69 57
8 KS8G - 4510 33.0 45.0 10 100 82.0 Head 192 164 144 130 116 90 77 63
9 KS8G - 5012 37.0 50.0 12 100 85.0 231 197 173 156 139 108 92 76
172
PERFORMANCE CHART FOR 20 CM BOREWELL SUBMERSIBLE PUMPSETS (MIX FLOW) KS8P AT RATED VOLTAGE OF
415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
Power Rating Outlet Rated LPM 0 750 950 1150 1350 1550 1750 1800
No of
S. No. Pump Model Size Current
Stages (Ampere)
kW HP (mm) m /h3
0.0 45.0 57.0 69.0 81.0 93.0 105.0 108.0
Head in Meters
PERFORMANCE CHART FOR 20 CM BOREWELL SUBMERSIBLE PUMPSETS (MIX FLOW) KS8B - ‘A’ AT RATED VOLTAGE OF
415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
Power Rating Outlet Rated LPM 0 800 1100 1400 1700 2000 2300 2700
No of
S. No. Pump Model Size Current
Stages (Ampere)
kW HP (mm) m /h3
0.0 48.0 66.0 84.0 102.0 120.0 138.0 162.0
Head in
Meters
PERFORMANCE CHART FOR 20 CM BOREWELL SUBMERSIBLE PUMPSETS (MIX FLOW) KS8B - ‘B’ AT RATED VOLTAGE OF
415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
Power Rating Outlet Rated LPM 0 900 1200 1500 1800 2100 2400 2700
No of
S. No. Pump Model Size Current
Stages (Ampere)
kW HP (mm) m /h3
0.0 54.0 72.0 90.0 108.0 126.0 144.0 162.0
Head in
Meters
PERFORMANCE CHART FOR 20 CM BOREWELL SUBMERSIBLE PUMPSETS (MIXED FLOW) KS8B - ‘C’ AT RATED VOLTAGE OF
415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
Power Rating Outlet Rated LPM 0 1300 1500 1700 1900 2100 2300 2400
No of
S. No. Pump Model Size Current
Stages (Ampere)
kW HP (mm) m3/h 0.0 78.0 90.0 102.0 114.0 126.0 138.0 144.0
Head in Meters
173
PERFORMANCE CHART FOR 20 CM BOREWELL SUBMERSIBLE PUMPSETS (MIX FLOW) KS8 AT RATED VOLTAGE OF
415 VOLTS - THREE PHASE, 50 HZ FREQUENCY, AC SUPPLY
Outlet Rated LPM 0 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
S. Pump Power Rating No of Size Current
No. Model Stages
kW HP (mm) (Ampere) m3/h 0.0 30.0 36.0 42.0 48.0 54.0 60.0 66.0 72.0 78.0 84.0 90.0 96.0 102.0 108.0
Meters
in
Head
174
FEATURES
Wide Voltage Motor Designs with Copper Rotor Head - Up to 114 Metres
Motors are designed with extra overload capacities, more water spaces and Discharge Range - Up to 3150 LPM
engineered with 99.9% pure Electro Grade Copper rotor performs well in low voltage Power Rating - 15 to 45 kW / 20 to 60 HP
with minimum discharge drops and suitable for wide voltage applications.
Voltage Range - 350 to 440 Volts (Three Phase)
Insulation - B Class
KS9 Dynamically Balanced Rotating Parts
Minimum vibration protects components from damage during the operation, thus
ensures consistent performance over longer time period as concentricity is
Type of Cooling - Water Cooled
Protection - IP68
22.5 CM BOREWELL
maintained.
SUBMERSIBLE PUMPS
Longer and Trouble Free Life
High grade engineering materials like Graded Cast Iron Components, Stainless Steel
Shaft, Stainless Steel Impellers, Bronze Bushes, Heavy duty Carbon + SS Thrust Impeller - Stainless Steel
Plate, 99.9 % Electro Grade Copper Rotor and Winding Wires for longer and trouble Stage Casing/Bowl - Cast Iron
free life. Pump Shaft - Stainless Steel
Motor Body - Stainless Steel
High Efficiency and Energy Saving Design
Innovative design manufactured at state of art plant, delivers optimum efficiency at Motor Shaft - Stainless Steel
lower energy consumption resulting in significant cost savings. Finished Rotor - Copper
NRV - Cast Iron
CED – Cathodic Electro Deposition Suction - Cast Iron
CED is the latest coating technology for corrosion resistance with uniform coating,
Pump / Motor Bushes - LTB
provides 5 times more protection over conventional painting, resulting in longer life.
All major CI parts of Kirloskar pumps coming in contact with the water are CED Thrust Bearing - Carbon + SS
coated.
175
PERFORMANCE CHART FOR 22.5 CM BOREWELL SUBMERSIBLE PUMPSETS - KS9A SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Head in Meters
2 KS9A - 4003 30.0 40.0 3 125 76.0 82 68 64 60 55 49 40 30
3 KS9A - 5004 37.0 50.0 4 125 85.0 110 91 86 80 73 65 54 40
4 KS9A - 6005 45.0 60.0 5 125 100.0 137 114 107 100 91 81 67 50
Head in Meters
2 KS9C - 3003 22.0 30.0 3 125 57.0 75 55 52 48 44 39 33 28
3 KS9C - 4004 30.0 40.0 4 125 76.0 99 73 69 64 58 52 45 38
4 KS9C - 5005 37.0 50.0 5 125 85.0 124 91 86 81 73 66 56 47
5 KS9C - 6006 45.0 60.0 6 125 100.0 149 110 103 97 88 79 67 56
176
FEATURES
Wide Voltage Motor Designs with Copper Rotor Head - Up to 427 Metres
Motors are designed with extra overload capacities, more water spaces and Discharge Range - Up to 650 LPM
engineered with 99.9% pure Electro Grade Copper rotor performs well in low voltage Power Rating - 2.2 to 18.5 kW / 3 to 25 HP
with minimum discharge drops and suitable for wide voltage applications.
Voltage Range - 200 to 440 Volts (Three Phase)*
Insulation - B Class
HHF/HHN Sand Fighter Designs
Innovative Sand Fighter Design restricts the entry of sand in motors,protects bushes
of pump and motor thus pumpset perform well in sandy borewells and increase life of
Type of Cooling - Water Cooled
Protection - IP68
pumpset. *Under ideal condition with suitable cable size.
15 CM HIGH HEAD
SUBMERSIBLE PUMPS
Dynamically Balanced Rotating Parts
Minimum vibration protects components from damage during the operation, thus
ensures consistent performance over longer time period as concentricity is
maintained.
HHN HHF
Longer and Trouble Free Life Impeller - Noryl Stainless Steel
High grade engineering materials like Graded Cast Iron Components, Stainless Steel Diffuser - Noryl Stainless Steel
Shaft, Stainless Steel/ Noryl Impellers, Bronze Bushes, Heavy duty Carbon + SS Diffuser Casing - Cast Iron Stainless Steel
Thrust Plate, 99.9 % Electro Grade Copper Rotor and Winding Wires for longer and Pump Shaft - Stainless Steel Stainless Steel
trouble free life.
Motor Body - Stainless Steel Stainless Steel
High Head Applications Motor Shaft - Stainless Steel Stainless Steel
The pump has been designed to deliver large volumes of water for high head Finished Rotor - Copper Copper
applications, helping customers to achieve high turnaround time and productivity. NRV - Cast Iron Cast Iron
Suction - Cast Iron Cast Iron
CED – Cathodic Electro Deposition
Pump / Motor Bushes - NBR / LTB NBR / LTB
CED is the latest coating technology for corrosion resistance with uniform coating,
provides 5 times more protection over conventional painting, resulting in longer life. Thrust Bearing - Carbon + SS Carbon + SS
All major CI parts of Kirloskar pumps coming in contact with the water are CED DOL - Cast Iron Cast Iron
coated.
177
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS - 60HHN SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Power Rating Outlet Rated Current LPM 0 120 150 180 210 240 270 300
Pump No of (Ampere)
S. No. Size
Model Stages
kW HP (mm) 3Ø m3/h 0.0 7.2 9.0 10.8 12.6 14.4 16.2 18.0
1 60HHN - 0305 2.2 3.0 5 50 6.5 61 57 55 52 49 44 40 35
2 60HHN - 0407 3.0 4.0 7 50 8.5 85 80 77 73 69 62 56 49
Head in Meters
3 60HHN - 0508 3.7 5.0 8 50 10.0 97 91 88 83 78 71 64 56
4 60HHN - 0610 4.5 6.0 10 50 12.0 121 114 110 104 98 89 80 70
5 60HHN - 0812 5.5 7.5 12 50 14.5 146 137 132 125 118 106 96 84
6 60HHN - 1016 7.5 10.0 16 50 19.5 194 182 176 166 157 142 128 112
7 60HHN - 1319 9.3 12.5 19 50 25.0 230 217 209 198 186 168 152 133
8 60HHN - 1524 11.0 15.0 24 50 29.0 291 274 264 250 235 212 192 168
9 60HHN - 1829 13.0 17.5 29 50 34.0 352 331 319 302 284 257 232 203
Power Rating Outlet Rated Current LPM 0 60 120 180 240 300 360 420
Pump No of (Ampere)
S. No. Size
Model Stages
kW HP (mm) 3Ø m /h3
0 3.6 7.2 11.5 14.4 18 21.6 25.2
1 80HHN - 0304 2.2 3.0 4 50 6.5 56 55 52 48 43 38 29 20
2 80HHN - 0405 3.0 4.0 5 50 8.5 70 68 65 60 54 47 36 24
3 80HHN - 0506 3.7 5.0 6 50 10.0 84 82 78 72 65 56 44 29
Head in Meters
4 80HHN - 0608 4.5 6.0 8 50 12.0 112 109 103 95 87 75 58 39
5 80HHN - 0810 5.5 7.5 10 50 14.5 140 137 129 119 108 94 73 49
6 80HHN - 1012 7.5 10.0 12 50 19.5 169 164 155 143 130 113 88 59
7 80HHN - 1315 9.3 12.5 15 50 25.0 211 205 194 179 163 141 109 73
8 80HHN - 1518 11.0 15.0 18 50 29.0 253 246 233 215 195 169 131 88
9 80HHN - 1821 13.0 17.5 21 50 34.0 295 287 271 250 228 197 153 102
10 80HHN - 2024 15.0 20.0 24 50 39.0 337 328 310 286 260 225 175 117
178
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS - 100HHN SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Power Rating Outlet Rated Current LPM 0 120 180 240 300 360 420 480
Pump No of (Ampere)
S. No. Size
Model Stages
kW HP (mm) 3Ø m /h3
0.0 7.2 10.8 14.4 18.0 21.6 25.2 28.8
1 100HHN - 0505 3.7 5.0 5 65 10.0 72 67 63 58 52 44 35 23
2 100HHN - 0606 4.5 6.0 6 65 12.0 86 80 76 70 62 53 42 28
Head in Meters
3 100HHN - 0808 5.5 7.5 8 65 14.5 115 107 101 93 83 70 56 37
4 100HHN - 1010 7.5 10.0 10 65 19.5 144 134 126 116 104 88 70 46
5 100HHN - 1312 9.3 12.5 12 65 25.0 172 161 151 139 125 106 84 55
6 100HHN - 1515 11.0 15.0 15 65 29.0 215 201 189 174 156 132 105 69
7 100HHN - 1818 13.0 17.5 18 65 34.0 258 241 227 209 187 158 126 83
8 100HHN - 2020 15.0 20.0 20 65 39.0 287 268 252 232 208 176 140 92
9 100HHN - 2525 18.3 25.0 25 65 48.0 359 335 315 290 260 220 175 115
Power Rating Outlet Rated Current LPM 0 100 220 280 350 410 470 530
Pump No of (Ampere)
S. No. Size
Model Stages
kW HP (mm) 3Ø m /h3
0.0 6.0 13.2 16.8 21.0 24.6 28.2 31.8
1 125HHN - 0403 3.0 4.0 3 65 8.5 45 44 41 38 34 29 23 16
2 125HHN - 0504 3.7 5.0 4 65 10.0 60 59 55 51 45 39 31 21
Head in Meters
3 125HHN - 0605 4.5 6.0 5 65 12.0 75 73 68 63 57 48 38 27
4 125HHN - 0806 5.5 7.5 6 65 14.5 90 88 82 76 68 58 46 32
5 125HHN - 1008 7.5 10.0 8 65 19.5 120 117 109 101 91 77 61 43
6 125HHN - 1310 9.3 12.5 10 65 25.0 150 147 137 127 113 97 77 53
7 125HHN - 1512 11.0 15.0 12 65 29.0 180 176 164 152 136 116 92 64
8 125HHN - 1814 13.0 17.5 14 65 34.0 210 205 191 177 159 135 107 75
9 125HHN - 2016 15.0 20.0 16 65 39.0 240 235 219 203 181 155 123 85
Power Rating Outlet Rated Current LPM 0 90 105 120 135 150 165 195
Pump No of (Ampere)
S. No. Size
Model Stages
kW HP (mm) 3Ø m /h3
0.0 5.4 6.3 7.2 8.1 9.0 9.9 11.7
1 50HHF - 0306 2.2 3.0 6 50 6.5 88 79 77 72 66 60 53 32
Head in Meters
179
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS - 60HHF SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Power Rating Outlet Rated LPM 0 100 120 140 160 180 200 220
Pump No of
S. No. Size Current
Model Stages
kW HP (mm) (Ampere) m /h3
0.0 6.0 7.2 8.4 9.6 10.8 12.0 13.2
1 60HHF - 0304 2.2 3.0 4 50 6.5 64 59 56 53 48 42 34 24
2 60HHF - 0305 2.2 3.0 5 50 6.5 79 74 70 66 61 53 42 29
3 60HHF - 0407 3.0 4.0 7 50 8.5 111 103 98 92 85 74 59 41
4 60HHF - 0508 3.7 5.0 8 50 10.0 127 118 112 105 97 84 67 47
5 60HHF - 0610 4.5 6.0 10 50 12.0 159 147 139 132 121 105 84 59
Head in Meters
6 60HHF - 0812 5.5 7.5 12 50 14.5 191 177 167 158 145 126 101 71
7 60HHF - 1013 7.5 10.0 13 50 19.5 207 192 181 171 157 137 109 77
8 60HHF - 1016 7.5 10.0 16 50 19.5 254 236 223 211 194 168 135 94
9 60HHF - 1319 9.3 12.5 19 50 25.0 302 280 265 250 230 200 160 112
10 60HHF - 1524 11.0 15.0 24 50 29.0 381 354 335 316 291 253 202 141
11 60HHF - 1829 13.0 17.5 29 50 34.0 461 427 404 382 351 305 244 171
Pump Power Rating Outlet Rated LPM 0 80 120 160 200 240 260 280
No of
S. No. Size Current
Model Stages (Ampere)
kW HP (mm) m /h3
0.0 4.8 7.2 9.6 12.0 14.4 15.6 16.8
1 80HHF - 0304 2.2 3.0 4 50 6.5 66 62 60 56 46 36 30 23
2 80HHF - 0405 3.0 4.0 5 50 8.5 82 78 75 70 58 46 38 29
3 80HHF - 0506 3.7 5.0 6 50 10.0 98 94 89 83 69 55 45 35
Head in Meters
4 80HHF - 0607 4.5 6.0 7 50 12.0 115 109 104 97 81 64 53 41
5 80HHF - 0810 5.5 7.5 10 50 14.5 164 156 149 139 115 91 75 58
6 80HHF - 1012 7.5 10.0 12 50 19.5 197 187 179 167 138 109 90 70
7 80HHF - 1315 9.3 12.5 15 50 25.0 246 234 224 209 173 137 113 87
8 80HHF - 1518 11.0 15.0 18 50 29.0 295 281 268 250 207 164 135 104
9 80HHF - 1821 13.0 17.5 21 50 34.0 344 328 313 292 242 191 157.5 122
10 80HHF - 2024 15.0 20.0 24 50 39.0 394 374 358 334 276 218 180 139
180
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS - 100HHF SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Power Rating Outlet Rated LPM 0 100 150 200 250 300 350 425
Pump No of
S. No. Size Current
Model Stages (Ampere)
kW HP (mm) m /h3
0.0 6.0 9.0 12.0 15.0 18.0 21.0 25.5
1 100HHF - 0303 2.2 3.0 3 50 6.5 50 48 45 43 38 31 20 8
2 100HHF - 0404 3.0 4.0 4 50 8.5 66 63 60 57 51 42 27 11
3 100HHF - 0505 3.7 5.0 5 50 10.0 83 79 75 71 63 52 33 13
Head in Meters
4 100HHF - 0606 4.5 6.0 6 50 12.0 100 95 90 85 76 63 40 16
5 100HHF - 0808 5.5 7.5 8 50 14.5 133 127 120 113 101 83 53 21
6 100HHF - 1010 7.5 10.0 10 50 19.5 166 158 150 142 127 104 67 27
7 100HHF - 1312 9.3 12.5 12 50 25.0 199 190 180 170 152 125 80 32
8 100HHF - 1515 11.0 15.0 15 50 29.0 249 238 225 213 190 156 100 40
9 100HHF - 1818 13.0 17.5 18 50 34.0 299 285 270 255 228 188 120 48
10 100HHF - 2020 15.0 20.0 20 50 39.0 332 317 300 283 253 208 133 53
Power Rating Outlet Rated LPM 0 80 160 240 320 400 480 520
Pump No of
S. No. Size Current
Model Stages
kW HP (mm) (Ampere) m3/h 0.0 4.8 9.6 14.4 19.2 24.0 28.8 31.2
1 125HHF - 0403 3.0 4.0 3 65 8.5 48 48 47 42 34 24 12 4
2 125HHF - 0504 3.7 5.0 4 65 10.0 64 64 62 55 45 32 16 5
3 125HHF - 0605 4.5 6.0 5 65 12.0 81 80 78 69 57 40 20 6
Head in Meters
4 125HHF - 0806 5.5 7.5 6 65 14.5 97 96 93 83 68 48 24 8
5 125HHF - 1008 7.5 10.0 8 65 19.5 129 127 124 111 91 64 31 10
6 125HHF - 1310 9.3 12.5 10 65 25.0 161 159 155 138 113 80 39 13
7 125HHF - 1512 11.0 15.0 12 65 29.0 193 191 186 166 136 96 47 15
8 125HHF - 1814 13.0 17.5 14 65 34.0 225 223 217 194 159 112 55 18
9 125HHF - 2016 15.0 20.0 16 65 39.0 258 255 248 221 181 128 63 20
181
PERFORMANCE CHART FOR 15 CM BOREWELL SUBMERSIBLE PUMPSETS - 150HHF SERIES
AT RATED VOLTAGE OF 415 VOLTS - THREE PHASE, 50 Hz FREQUENCY, AC SUPPLY
Power Rating Outlet Rated LPM 0 180 240 300 360 420 480 540
Pump No of
S. No. Size Current
Model Stages
kW HP (mm) (Ampere) m /h3
0.0 10.8 14.4 18.0 21.6 25.2 28.8 32.4
1 150HHF - 0503 3.7 5.0 3 65 10.0 48 45 43 41 37 30 21 9
2 150HHF - 0604 4.5 6.0 4 65 12.0 64 60 58 55 50 40 29 13
Head in Meters
3 150HHF - 0805 5.5 7.5 5 65 14.5 80 75 72 68 62 49 36 16
4 150HHF - 1007 7.5 10.0 7 65 19.5 112 105 101 95 87 69 50 22
5 150HHF - 1308 9.3 12.5 8 65 25.0 128 120 115 109 99 79 57 25
6 150HHF - 1510 11.0 15.0 10 65 29.0 160 150 144 136 124 99 71 31
7 150HHF - 1812 13.0 17.5 12 65 34.0 192 180 173 164 149 119 86 38
8 150HHF - 2013 15.0 20.0 13 65 39.0 208 195 187 177 161 128 93 41
Power Rating Outlet Rated LPM 0 100 200 300 400 500 600 650
Pump No of
S. No. Size Current
Model Stages
kW HP (mm) (Ampere) m /h3
0.0 6.0 12.0 18.0 24.0 30.0 36.0 39.0
1 200HHF - 0402 3.0 4.0 2 65 8.5 30 30 30 28 24 18 8 3
2 200HHF - 0603 4.5 6.0 3 65 12.0 45 45 45 43 37 27 12 4
Head in Meters
3 200HHF - 0804 5.5 7.5 4 65 14.5 60 60 60 57 49 36 16 6
4 200HHF - 1005 7.5 10.0 5 65 19.5 76 75 75 71 61 46 21 7
5 200HHF - 1306 9.3 12.5 6 65 25.0 91 90 89 85 73 55 25 8
6 200HHF - 1508 11.0 15.0 8 65 29.0 121 120 119 114 98 73 33 11
7 200HHF - 2010 15.0 20.0 10 65 39.0 151 150 149 142 122 91 41 14
182
183
SUBMERSIBLE
PRODUCT RANGE
OPENWELL SUBMERSIBLE
PUMPSET
184
FEATURES TECHNICAL SPECIFICATION
Wide Voltage Design Head Range - Up to 64 Metres
The motor is designed to withstand wide voltage variations which reduces the Discharge Range - Up to 48.5 LPS
chances of motor burning at low voltage.
Power Rating - 2.2 to 15 kW (3 to 20 HP)
Design to Prevent Overloading Voltage Range* - 200 to 440 Volts (Three Phase)
Lesser chances of motor burning even if the pump operates at lower head than Insulation - PP
JOS recommended as motor does not get overload thus ensures substantial saving from
maintenance cost and breakdown.
Protection - IP68
*Under ideal condition with suitable cable size.
HORIZONTAL High Efficiency and Energy Saving Design
OPENWELL PUMPS MATERIAL OF CONSTRUCTION
Innovative design manufactured at state of art plant, delivers optimum efficiency at
lower energy consumption resulting in significant cost savings.
Impeller - Cast Iron
Dynamically Balanced Rotating Parts Delivery Casing - Cast Iron
Minimum vibration protects components from damage during the operation, thus Motor Body - Cast Iron
ensures consistent performance over longer time period as concentricity is Pump Shaft - Stainless Steel
maintained.
APPLICATIONS
Advanced Water Cooled Motors Designs
The motor is filled with potable water, protects from overheating and facilitates Ÿ Irrigation in horticulture & agriculture
smoother and trouble free operation for the years. Ÿ Sprinkler and drip irrigation
Ÿ Water supplies for high rise building
Wide Voltage Motor Designs
Motors are designed with extra overload capacities, more water spaces and Ÿ Rural water supply
engineered with high grade materials to performs well in low voltage with minimum Ÿ Domestic and community water supply
discharge drops and suitable for wide voltage applications.
185
PERFORMANCE CHART FOR JOS SERIES, 2 POLE, OPENWELL PUMPS, AT RATED VOLTAGE,
50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
186
FEATURES TECHNICAL SPECIFICATION
Wide Voltage Design Head - Up to 147 Metres
The motor is designed to withstand wide voltage variations which reduces the Capacity - Up to 840 LPM
chances of motor burning at low voltage.
Power Rating - 2.2 to 15 kW / 3 to 20 HP
Design to Prevent Overloading Voltage Range - 200 to 440 Volts (Three Phase)*
Lesser chances of motor burning even if the pump operates at lower head than
JVS recommended as motor does not get overload thus ensures substantial saving from
maintenance cost and breakdown.
Insulation
Protection
-
-
PP
IP68
187
PERFORMANCE CHART FOR 'JVS' SERIES, 2 POLE, MULTISTAGE VERTICAL OPENWELL SUBMERSIBLE PUMPS,
AT RATED VOLTAGE OF 415 VOLTS, 50 Hz FREQUENCY, THREE PHASE A.C. POWER SUPPLY
MOTOR FULL LPM 120 240 360 480 600 720 840
OUTLET
Sr. PUMP RATING NO. OF LOAD
SIZE
No. MODEL STAGES CURRENT
(mm) m3/hr 7 14 22 29 36 43 50
kW HP (Amps)
1 JVSA 0502 3.7 5 2 80 10 37 35 34 31 25 16 7
2 JVSA 0803 5.5 7.5 3 80 14.5 55 53 51 46 37 24 10
3 JVSA 1004 7.5 10 4 80 19.5 HEAD IN 73 71 68 61 49 32 13
4 JVSA 1305 9.3 12.5 5 80 25 METERS 92 88 85 77 62 40 17
5 JVSA 1506 11 15 6 80 29 110 106 102 92 74 48 20
6 JVSA 2008 15 20 8 80 39 147 141 136 123 99 64 27
LPM 120 180 240 300 360 420 480
m3/hr 7 11 14 18 22 25 29
7 JVSC 0302 2. 2 3 2 80 6.5 35 34 32 29 25 20 14
8 JVSC 0503 3.7 5 3 80 10 HEAD IN 53 51 48 44 38 30 21
9 JVSC 0805 5.5 7.5 5 80 14.5 METERS 88 85 80 73 63 50 35
10 JVSB 1007 7.5 10 7 80 19.5 119 115 109 98 84 65 42
LPM 120 240 360 420 480 600 720
m3/hr 7 14 22 25 29 36 43
11 JVSD 0804 5.5 7.5 4 80 14.5 77 73 65 60 54 39 20
12 JVSD 1005 7.5 10 5 80 19.5 HEAD IN 96 91 81 75 68 49 25
13 JVSD 1306 9.3 12.5 6 80 25 METERS 116 109 98 90 81 59 30
14 JVSD 1507 11 15 7 80 29 135 127 114 105 95 68 35
MOTOR FULL LPM 180 300 420 540 660 780 840
RATING OUTLET
Sr. PUMP NO. OF LOAD
IN
No. MODEL STAGES CURRENT
mm 3
m /hr 11 18 25 32 40 47 50
kW HP (Amps)
1 JVSA - 0502N 3.7 5 2 65 10 HEAD IN 45 43 40.5 36 30 23 18.5
2 JVSA - 0803N 5.5 7.5 3 65 14.5 METERS 65.5 61.5 57 51.25 41.5 31 24.5
Note:
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
n Vertical Openwell Submersible(JVS) Pump at 50 Hz frequency and 415 rated Voltage.
188
189
OTHER
PRODUCT RANGE
END-SUCTION PUMPS
190
FEATURES
Flatter Efficiency Curve Engine Coupled Motor Coupled
Minimum variations in efficiency during the entire operating range increases the Head - Up to 44 Metres Up to 32 Meters
utility of pump set for variable conditions.
Discharge Range - Up to 96.5 LPS Up to 87 LPS
Automatic Air Release Power Rating - 3.7 to 18.7 kW 2.2 to 11 kW
Automatically releases air when the pump starts ensuring swifter and smoother (5 to 25 HP) (3 to 15 HP)
NW/NWD operations, thus eliminating the necessity of operating air release cock.
NWD
191
PERFORMANCE CHART FOR NW / NW+ / NWD ENGINE COUPLED END SUCTION PUMPS AT RATED SPEED
Note:
n NW-9D (pipe size : 150 x 150 mm) can be supplied with 125 to 150 mm extension flanges for both suction and delivery sizes against requirement.
direction of rotation for all pump models is clockwise except for NW8D, NW10D, NW11D, and Nw12D it is anticlockwise when viewed from suction side.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
192
PERFORMANCE CHART FOR NW / NW+ / NWD ENGINE COUPLED END SUCTION PUMPS AT RATED SPEED
193
PERFORMANCE CHART FOR NW / NW+ / NWD ENERGY EFFICIENT IE2 MOTOR COUPLED PUMPS AT RATED SPEED
PERFORMANCE CHART FOR NW / NW+ / NWD ENERGY EFFICIENT IE2 MOTOR COUPLED PUMPS AT RATED SPEED
Power Pipe Size Impeller
Sr. Pump Model Rating (mm) Diameter 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
No. (mm)
kW HP DEL
Note:
n NW-9D (pipe size : 150 x 150 mm) can be supplied with 125 to 150 mm extension flanges for both suction and delivery sizes against requirement.
direction of rotation for all pump models is clockwise except for NW8D, NW10D, NW11D, and Nw12D it is anticlockwise when viewed from suction side.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
194
FEATURES
Flatter Efficiency Curve Head - Up to 23 Metres
Minimum variations in efficiency during entire operating range increases the utility of
Discharge Range - Up to 37 LPS
pump set for variable conditions.
Power Rating - 3.7 to 5.9 kW (5 to 8 HP)
Automatic Air Release
Automatically releases air when the pump starts ensuring swifter and smoother
KE operations, thus eliminating the necessity of operating air release cock.
Impeller - Cast Iron
Design To Prevent Overloading Delivery casing - Cast Iron
END-SUCTION Lesser chances of motor burning as it does not get overloaded even if the pump is
PUMPS operated at a heat lower than recommended, thus ensuring substantial cost saving Pump shaft - Carbon Steel
due to low maintenance and breakdown.
APPLICATIONS
Replaceable Wearing Parts
All wearing parts within the pumps are easily accessible and replaceable which • Irrigation in (horticulture & agriculture)
provides ease of maintenance thereby extending the life of the pump.
• Rural water supply
Dynamically Balanced Rotating Parts • Mounting on water tanker
Minimum vibration protect components from damage during the operation, thus
ensuring consistent performance as concentricity is maintained.
195
PERFORMANCE CHART FOR ‘KE’ SERIES, COUPLED END SUCTION PUMPS AT RATED SPEED
Note:
n All pumps except 100 KE-215+, type TA-1 are ISI complied.
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
196
FEATURES
Flatter Efficiency Curve Head - Up to 52 Metres
Minimum variations in efficiency during entire operating range increases the utility of
Discharge Range - Up to 12 LPS
pump set for variable conditions.
Power Rating - 0.25 to 7.5 kW (0.33 to 10 HP)
Automatic Air Release
Automatically releases air when the pump starts ensuring swifter and smoother
KH operations, thus eliminating the necessity of operating air release cock.
Impeller - Cast Iron
Design To Prevent Overloading
END-SUCTION Delivery casing - Cast Iron
Lesser chances of motor burning as it does not get overloaded even if the pump is
PUMPS operated at a heat lower than recommended, thus ensuring substantial cost saving Pump shaft - Carbon Steel
due to low maintenance and breakdown.
197
PERFORMANCE CHART FOR ‘KH’ SERIES, COUPLED END SUCTION PUMPS AT RATED SPEED
Power Pipe Size Rated Impeller TOTAL HEAD IN METERS
Sr. Pump Model Rating (mm) Speed Diameter 6 7 8 9 10 11 12 13 14 15 16 17 18 19
No. (RPM) (mm)
kW HP SUC. DEL DISCHARGE IN LITRES PER SECOND
1 KH-1 0.25 0.33 25 25 2900 80 2.0 1.6 0.8 - - - - - - - - - - -
2 KH-1 0.37 0.5 25 25 2900 91 - 2.4 2.2 2.0 1.6 - - - - - - - -
3 KH-1 0.55 0.75 25 25 2900 99 - 2.8 2.6 2.4 2.2 1.6 0.4 - - - - - -
15 16 17 18 19 20 21 22 23 24 25 26 27 28
4 KH-3 2.2 3 40 30 2810 146 - - - - - - - 6.4 6.1 5.8 5.4 4.9 4.4 3.4
5 KH-4 1.5 2 40 40 2800 148 6.0 5.6 5.2 4.9 4.5 4.0 3.5 3.0 2.3 1.1 - - - -
6 KH-5 2.2 3 40 40 2810 149 - - - - - - - - 6.4 6.0 5.4 4.7 3.7 -
30 32 34 36 38 40 42 44 46 48 50 52 54 56
7 KH-6 3.7 5 50 40 2820 172 6.8 6.4 5.5 4.5 3.0 - - - - - - - - -
8 KH-7 5.5 7.5 50 40 2840 197.5 - 8.5 8.3 8.2 8.0 7.6 7.2 6.6 6.0 5.2 4.0 1.0 - -
9 KH-12 7.5 10 65 50 2830 195 - 12.0 11.8 11.5 11.1 10.6 9.9 9.0 8.1 6.8 - - - -
Note:
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
198
FEATURES
Flatter Efficiency Curve Head - Up to 104 Metres
Minimum variations in efficiency during entire operating range increases the utility of
Discharge Range - Up to 19.4 LPS
pump set for variable conditions.
Power Rating - 3.7 to 15 kW (5 to 20 HP)
Automatic Air Release
Automatically releases air when the pump starts ensuring swifter and smoother
KHDT operations, thus eliminating the necessity of operating air release cock.
Impeller - Cast Iron
Design To Prevent Overloading Delivery casing - Cast Iron
END-SUCTION Lesser chances of motor burning as it does not get overloaded even if the pump is
PUMPS Pump shaft - Carbon Steel
operated at a heat lower than recommended, thus ensuring substantial cost saving
due to low maintenance and breakdown.
APPLICATIONS
Replaceable Wearing Parts
All wearing parts within the pumps are easily accessible and replaceable which • Irrigation in (horticulture & agriculture)
provides ease of maintenance thereby extending the life of the pump. • Rural water supply
199
PERFORMANCE CHART FOR 'KHDT+' END SUCTION PUMPS AT RATED SPEED
Note:
n Performance applicable to liquid of specific gravity 1 and viscosity as of water.
200
FEATURES
Flatter Efficiency Curve
Head - Up to 136 Metres
Minimum variations in efficiency during entire operating range increases the utility of
pump set for variable conditions. Discharge Range - Up to 14.8 LPM
Power Rating - 5.9 to 19 kW (8 to 26 HP) with Engine
Automatic Air Release 3.7 to 9.3 kW (5 to 12.5 HP)
Automatically releases air when the pump starts ensuring swifter and smoother
SR operations, thus eliminating the necessity of operating air release cock.
201
PERFORMANCE CHART FOR 'SR' SERIES,ENGINE COUPLED END SUCTION PUMPS
AT RATED SPEED
Rated TOTAL HEAD IN METERS
Power Rating Pipe Size (mm)
S. No. PUMP MODEL SPEED 50 60 70 80 90 95 100 110 120 130 136
kW HP SUC. DEL. (RPM) DISCHARGE IN LITRES PER SECOND
1 8SR7 5.9 8 65 50 1800 5.4 4.8 4.2 3.5 2.5 1.9 1.0 - - - -
2 16SR6 11.8 16 80 65 1800 12.0 10.7 9.5 8.0 6.2 5.0 - - - - -
3 26SR9* 19 26 80 65 1800 14.8 13.9 13.1 12.4 11.5 11.1 10.6 9.5 8.5 7.0 5.8
PERFORMANCE CHART FOR 'SR' SERIES, MOTOR COUPLED END SUCTION PUMPS
AT RATED SPEED
Note:
n * Also Available in reverse rotation as 26SR9R (Direction anti-clockwise when viewed from non-driving end).
202