LINDAPTOR
LINDAPTOR
Type A
Lindapter’s standard clamp is used to resist
moderate tensile loading. Can also be used
with Type B in a Girder Clamp configuration.
Nose Recess
GIRDER CLAMPS
Clamping
Area
T
V
Y X
LIFTING POINTS
Z
HOLLO-BOLT
Packings are available to increase the clamping range, see page 10.
Location plate / end plate details can be found on page 11.
A08 M8 1.0 - 6 16 8 - 4 - 4 20
A10 M10 1.5 - 20 20 11 4 5 7 5 26
A12 M12 5.8 0.7 69 26 13 4.5 6 9.5 6 29
A16 M16 7.3 1.5 147 30 16 5.5 8 11 8 36
A20 M20 14.7 3.0 285 36 19 7 10 12.5 10 46
DECKING FIXINGS
For Characteristic Resistances when designing a connection to Eurocode 3, please refer to DoP No.003 on the website www.Lindapter.com/About/CE
®
+44 (0) 1274 521444 www.Lindapter.com © Lindapter International 2018
10 | Girder Clamps by Lindapter ®
T T
Z Z Z
Mild steel, zinc plated / hot dip galvanised. Mild steel, malleable iron, zinc plated / hot dip galv. Mild steel, malleable iron, zinc plated / hot dip galv.
RAIL FIXINGS
Product Bolt Size Dimension Product Bolt Size Dimension Product Bolt Size Dimension
Code Z T (mm) Code Z T (mm) Code Z T (mm)
CW24 M24 4 P1S24 M24 12 Note: The Type W is used to fill the recess in the
P2S10 M10 10 Type A to convert it into a flat top clamp to enable
* CW08 is only available zinc plated.
the bolt head or nut to be rotated.
P2S12 M12 12
P2S16 M16 16
P2S20 M20 20
P2S24 M24 24
HOLLO-BOLT
the table below. Please note these calculations are for beams up to
and including 5O sloped flanges. Type B
For example, a M24 Type A/B on a 26mm flange requires 1 x Type A/B
short tail (S), 1 x Type CW (CW) and 1 x Type P1 short (P1S). Packing
Piece
For thicker flanges contact Lindapter.
Flange M12 M16 M20 M24 Flange M12 M16 M20 M24
Thickness Thickness
SUPPORT FIXINGS
mm A/B CW P1S P2S A/B CW P1S P2S A/B CW P1S P2S A/B CW P1S P2S mm A/B CW P1S P2S A/B CW P1S P2S A/B CW P1S P2S A/B CW P1S P2S
5 S - - - S - - - - - - - - - - - 17 M 2 1 - L 2 - - S - 1 - S 2 - -
6 M - - - S - - - - - - - - - - - 18 M - - 1 L 2 - - M 2 - - S 2 - -
7 S 1 - - M - - - S - - - - - - - 19 S 1 - 1 L - 1 - S 3 - - L 1 - -
8 S 1 - - M - - - S - - - - - - - 20 S 1 - 1 L 3 - - M - 1 - L 1 - -
9 M 1 - - S 1 - - M - - - S - - - 21 M 1 - 1 L 3 - - S 1 1 - S - 1 -
10 L - - - L - - - M - - - S - - - 22 L - - 1 L 1 1 - M 3 - - S - 1 -
11 M 2 - - L - - - S 1 - - M - - - 23 S - 1 1 L 1 1 - L - 1 - M - 1 -
12 L 1 - - S 2 - - S 1 - - M - - - 24 M - 1 1 M - - 1 M 1 1 - M - 1 -
DECKING FIXINGS
13 S 1 1 - S - 1 - L - - - S 1 - - 25 S 1 1 1 L 2 1 - S 2 1 - S 1 1 -
14 S 1 1 - L 1 - - M 1 - - S 1 - - 26 S 1 1 1 L 2 1 - S 2 1 - S 1 1 -
15 L 2 - - S 3 - - S 2 - - L - - - 28 L - 1 1 S 2 - 1 M 2 1 - L - 1 -
16 L - 1 - M - 1 - S 2 - - L - - - 30 M - - 2 L 1 - 1 M - - 1 S 2 1 -
A/B = Type A/B S = A/B short M = A/B medium L = A/B long CW = Type CW P1S = Type P1 short P2S = Type P2 short
®
+44 (0) 1274 521444 www.Lindapter.com © Lindapter International 2018
Girder Clamps by Lindapter ® | 11
Location Plate
GIRDER CLAMPS
What is it?
Location plates are simple fabricated PLATE DIMENSIONS
items designed to sit between the L1 = Plate Length, L2 = Plate Width,
B1, B2 = Flange Width, C1, C2 = Hole Centres, d = Hole Ø
two sections to be clamped together
to ensure the bolts are fixed at the
L1
correct centres.
C1
RAIL FIXINGS
For other grades contact Lindapter.
LIFTING POINTS
M12 14 8 B1 + 14 B1 + 54 B2 + 14 B2 + 54 d
M16 18 10 B1 + 18 B1 + 70 B2 + 18 B2 + 70
M20 22 12 B1 + 22 B1 + 88 B2 + 22 B2 + 88
B1
M24 26 15 B1 + 26 B1 + 104 B2 + 26 B2 + 104
HOLLO-BOLT
End Plate
What is it?
End plates are simple fabricated items PLATE DIMENSIONS
that are pre-welded to support frames, L1 = Plate Length, L2 = Plate Width,
B = Flange Width, C1, C2 = Hole Centres, d = Hole Ø
bracket or sections, allowing connection
to the supporting structure with standard
L1
FLOOR FIXINGS
Lindapter clamps.
C1
mm mm mm mm mm mm C2 L2
M8 9 10 B+9 B + 36 40 C2 + 40
M10 11 12 B + 11 B + 44 50 C2 + 40 d
M12 14 12 B + 14 B + 54 60 C2 + 50
M16 18 15 B + 18 B + 70 70 C2 + 60
M20 22 20 B + 22 B + 88 90 C2 + 70
B
M24 26 25 B + 26 B + 104 110 C2 + 90
DECKING FIXINGS
1) Depending on the type of connection and associated end plate use, the thickness may need to be modified to comply with accepted local design codes.
To calculate the bolt length, add up the total distance that the bolt will pass through, plus half of the bolt diameter.
Then round up the total to the nearest available bolt length. An example can be found on page 6.
®
© Lindapter International 2018 www.Lindapter.com +44 (0) 1274 521444