0% found this document useful (0 votes)
89 views8 pages

Digital Thermometer Catalog

The document provides information on various digital thermometers from a company. It lists several models of thermometers, their key features and specifications. The thermometers can measure temperature using different sensor types and ranges and include features like data logging and alarms.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
89 views8 pages

Digital Thermometer Catalog

The document provides information on various digital thermometers from a company. It lists several models of thermometers, their key features and specifications. The thermometers can measure temperature using different sensor types and ranges and include features like data logging and alarms.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Digital Thermometer

PCE-T 390 PCE-T 1200


4-Channel Thermometer with SD Card 12-Channel Data Logger
• 4 channels for K and J type, 2 channels for Pt100 • LC display 4.5“ (82 x 61 mm)
• real-time memory due to SD memory card (1 ... • timer to adjust the logging interval
16GB) • Min / Max alarm for each input
• LCD 4 digits (backlight) • Min / Max / Hold / integrated calendar
• Min / Max values / Automatic Power Off • 2 GB SD card / cards of up to 16 GB possible
• Auto Power Off / Auto Temperature Compensation

TOP
seller

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS


Range K: -200 ... +1370 °C / Pt100: -200 ... +1562 °C Sensor Resol. Meas. range Accuracy
Resol. K: 0.1°C (-200 ... +1000 °C) / 1°C (>1000 °C) K type 0.1 °C -50.1 ... -100 °C ±0.4 % + 1 °C
Pt100: 0.1°C (-200 ... +850 °C) / 1°C (>850°C) 0.1 °C -50 ...+999.9 °C ±0.4 % + 0.5 °C
Accuracy K: ± 0.5 % of reading +1 °C 1 °C +1000...+1300 °C ±0.4 % + 1 °C
Pt100: ± 0.4 % of reading +1 °C J type 0.1 °C -50.1 ... -100 °C ±0.4 % + 1 °C
Inputs 4 x K type / 2 x Pt100 0.1 °C -50 ...+999.9 °C ±0.4 % + 0.5°C
Sampling rate 1 ... 3599 s (adjustable) 1 °C +1000...+1150 °C ±0.4 % + 1 °C
Memory flexible via SD card up to 16 GB T / E type 0.1 °C -50.1 ... -100 °C ±0.4 % + 1 °C
Display LCD 4 digits / 52 x 38 mm T type 0.1 °C -50 ... +400 °C ±0.4 % + 1 °C
Power supply 6 x 1.5 V AAA or mains adaptor E type 0.1 °C -50 ... +900 °C ±0.4 % + 0.5°C
Operating conditions 0 ... +50 °C, <80 % RH R type 1 °C 0 ... +1700 °C ±0.5 % + 3 °C
Dimensions 174 x 68 x 42 mm S type 1 °C 0 ... +1500 °C ±0.5 % + 3 °C
Weight 310 g Operating cond. 0 °C ... +50 °C / <85 % RH
INCLUDES Dimens. / weight 225 x 125 x 64 mm / 827 g
Thermometer, 2 x K type probes, batteries, SD card, SD INCLUDES
card reader, instruction manual 12-channel data logger, 2 K type wire sensors, batteries, SD card, carrying case, Instruction manual
ITEM NO. ITEM ITEM NO. ITEM
K-PCE-T390 4-channel thermometer K-PCE-T 1200 PCE-T 1200 data logger
OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES
K-NET-LUT mains adaptor K-CAL PCE-T1200 4-channel calibration certificate
K-CAL-PCE-T390 ISO calibration certificate K-NET-LUT mains adaptor
For more probes see page 11 For more probes see page 11

10 www.pce-instruments.com/us
Digital Thermometer
PCE-MF 1 PCE-777 PCE-888
Mini Infrared Thermometer +250 °C Mini Infrared Thermometer ≤330 °C IR Thermometer for Maintenance
• HACCP / Automatic Power Off / quick measurement • laser pointer for accurate targeting • large LC display of 3 1/2 digits with backlight /
• displays last value for 15 seconds • selectable units visible laser pointer

• distance-to-measuring point ratio of 1:1 (measuring • out-of-range indication • adjustable emissivity


point diameter approx. 10 cm at a distance of • display backlight • Automatic Power Off (after 7 seconds of inactivity)
approx. 10 cm) • good distance-to-measuring point diameter ratio
• Automatic Power Off
of 16:1, measuring point diameter approx 19 mm if
distance is approx.30 cm, 75 mm for 1.2 m and 150
mm for 2.4 m

TOP
seller

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS


Meas. range -35 ... +250 °C Meas. range -50 ... +330 °C Meas. range -50 ... +550 °C
Resolution 0.1 °C Resolution 0.1 °C Resolution ≤200 °C: 0.1 °C, otherwise 1 °C
Accuracy ±2 °C or ± 2 % (higher value) Accuracy -50...0°C: ±4°C; 0...+330°C: ±2°C Accuracy -50 ... -20 °C: ± 5 °C
Response time < 300 ms Response time <1 s -20 ... +550 °C: ± 1.5 % ± 2 °C
Optical resolution 1:1 Optical resolution 12:1 Response time <500 ms
Emissivity 0.95 Class II laser power <1 mW, 360 ~ 607 nm Emissivity 0.10 ... 1.0 (adjustable)
Spectral range 8 ... 14 μm Emissivity fixed at 0.95 Spectral range 8 ... 14 µm
Backlight included Spectral range 8 ... 14 µm Visible laser 1-point beam, extra bright
Data Hold 15 s Auto Power Off after 20 seconds of inactivity Backlight included
Power supply CR 2032 battery Display LCD, backlight Power supply 1 x 9 V battery
Operating cond. 0 ... +50 °C Power supply 9 V battery Operating cond. 0 ... +50 °C
Dimensions 40 x 75 x 20 mm Operating cond. 0 ... +50 °C / 10 ... 95 % RH Dimensions 230 x 56 x 100 mm
Weight 33 g Dimensions / weight 134 x 88.5 x 36 mm / 145 g Weight 290 g
INCLUDES INCLUDES INCLUDES
Infrared thermometer, battery, carrying strap, instruction Infrared thermometer, 9 V battery, Infrared thermometer, carrying case, battery,
manual instruction manual instruction manual
ITEM NO. ITEM ITEM NO. ITEM ITEM NO. ITEM
K-PCE-MF 1 infrared thermometer K-PCE-777 infrared thermometer K-PCE-888 Infrared thermometer
OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES
K-CAL-IR ISO calibration certificate K-CAL-PCE-888 ISO calibration certifcate

12 www.pce-instruments.com/us
Digital Thermometer
PCE-889A PCE-779N PCE-IR 425
Professional Thermometer up to IR Thermometer up to 760 °C IR Thermometer up to 1000 °C
+1050 °C • input for thermocouple sensor • input for thermocouple probe NiCr-Ni (K type)
• high accuracy • large display to show measurement value and min / • large display to show measurement value and min /
max values at the same time max or limit values at the same time
• non-contacting temperature measurement
• alarm values • functions: HOLD-, MAX-, MIN-, DIF-, AVG
• distance-to-measuring point diameter ratio 30:1
• signal when measured value is exceeded • audio / visual alarms
• data hold / continuous measurement function
• LC display with backlight • 2-point laser

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS


Meas. range -50 ... + 1050 °C Measurem. range IR: -50 ... +760 °C Meas. range IR: -60 ... +1000 °C
Resolution 0.1 °C K-type: -64 ... +1400 °C Type K: -64 ... +1370 °C
Accuracy -50 ... 0 °C: ±4 °C Resolution 0.1°C(-83.2...+999.9 °C),otherw. 1°C Resolution ≤+200 °C: 0.1 °C; otherwise: 1 °C
0 ... +1050 °C: ± 3 % of rdg. ± 2 °C Accuracy IR: TObj = -60 ... 0 ±(2+0.05/°C)°C, Accuracy IR: ±2 % or ±2 °C (higher value)
Response time <250 ms TObj= 0 ... 760: ±2 % of reading or Type K: ±1 % or ±1 °C (higher val.)
Emissivity 0.10 ... 1.00 (adjustable) ±2 °C; higher value applies Opt. resol. / response50:1 / < 200 ms
Spectral range 8 ... 14 µm K-type: ±1 % of reading or ±1 °C; Emissivity 0.10 ... 1.00 (adjustable)
Visible laser 1-point beam, extra bright higher value applies (measurement Laser 2 visible points / 6 ... 14 µm
Backlight included below TEnv= 23 ±6 °C) Power supply 2 x 1.5 V AAA batteries
Power supply 1 x 9 V battery Ratio / response t. 30:1 / 1 s Operating cond. 0 ... +50 °C / 10 ... 90 % RH
Operating cond. 0 ... +50 °C / 10 ... 95 % RH Emissivity 0.10 ... 1.00 (adjustable) (non-condensing)
Dimensions 155 x 98 x 27 mm Laser class 2 Dimensions 215 x 145 x 45 mm
Weight 271 g Power supply 2 x AAA (alkaline) Weight 1150 g
INCLUDES Operating cond. 0 ... +50 °C INCLUDES
Weight approx. 256 g (with batteries)
Infrared thermometer, carrying case, battery, instruction Infrared thermometer PCE-IR 425, carrying case,
manual INCLUDES batteries, instruction manual
ITEM NO. ITEM IR thermometer, K-TE-type, 2 x batteries, manual ITEM NO. ITEM
K-PCE-889 infrared thermometer ITEM NO. ITEM K-PCE-IR 425 infrared thermometer
OPTIONAL ACCESSORIES K-PCE-779N infrared thermometer OPTIONAL ACCESSORIES
K-CAL-PCE-889 ISO calibration certificate OPTIONAL ACCESSORIES K-CAL-PCE-IR 425 ISO calibration certificate
K-CAL-IR ISO calibration certificate (IR only) (IR sensor only)
K-MINI-STAT mini tripod

www.pce-instruments.com/english 13
Digital Thermometer
PCE-TH 5 PCE-310 PCE-320
Hygrometer with Dew point / Wet Bulb Psychrometer (Dew Point / ΔT) Psychrometer with IR Thermometer
• temperature / humidity determination by internal • ambient humidity / temperature by internal sensor • humidity / temperature of walls or products by
sensors • temperature sensor for walls and materials internal, external or infrared sensor
• calculates dew point, wet bulb temperature, heat • dual display for temperature and humidity • LCD dual display for temperature and humidity
index values and WBGT (heat stress index) • dew point and wet bulb
• dew point / wet bulb temperature
• functions: HOLD, MIN / MAX and MEAN values • HOLD, MIN, MAX
• differenial temperature T1 - T2
• alarm limit for heat index / WBGT • 4 seconds response time
• MIN / MAX / HOLD
• operated by lithium battery / battery saving function
• 60 seconds response time

TOP
seller

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS


Temp. meas. range -20 ... +50 °C Measurement range Temperature Relative hum. Meas. range Temperature Relative humidity
Resolution 0.1 °C (internal sensor) -20 ... +50 °C 0...100 % RH (internal sensor) -20 ... +60 °C 10 ... 90 % RH
Accuracy ± 0.6 °C Wet bulb -21.6 ... +50 °C Wet bulb -21.6 ... +60 °C
Ambient hum.m. r. 0 ... 99.9 % RH Dew point -78.7 ... + 50 °C Dew point -68 ... +60 °C
Resolution 0.1 % RH Temp. (ext. sensor) -20 ... +70 °C Temp. (ext. / IR) -20 ... +750 °C -50 ... +500 °C
Accuracy ± 3 % RH at +25 °C / 10 ... 90 %, Resolution Temperature Relative hum. Resolution Temperature Relative humidity
otherwise ±5 % 0.1 °C 0.1 % 0.1 °C 0.1 %
Power supply 3.0 V lithium battery, CR2032 Accuracy Temperature Relative hum. Accuracy Temperature Relative humidity
Operating cond. -20 ... +50°C, <80 % RH ±1 °C ±3 % ± 1.0 °C ± 3.0 %
Dimensions 135 x 18 x 36.3 mm Power supply 2 x 1.5 V AAA batteries Temp. (ext. / IR) ± 1.0 % ± 1.0 °C ± 2.0 % / ± 2.0 °C
Operating cond. -20 .. +50°C / 0 ..100 % RH Power supply 1 x 9 V battery
Dimensions / weight 25 x 50 x 180 mm / 130 g Dimen. / weight 257 x 76 x 53 mm / 355 g
INCLUDES INCLUDES INCLUDES
Thermohygrometer, battery, case, Psychrometer, external sensor with 1.1 m cable, Psychrometer, external wire sensor, (max.+220 °C),
instruction manual batteries, instruction manual software, PC cable, battery, instruction manual
ITEM NO. ITEM ITEM NO. ITEM ITEM NO. ITEM
K-PCE-TH 5 thermohygrometer K-PCE-310 psychrometer K-PCE-320 psychrometer
OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES
K-CAL-PCE-HT110 ISO calibration certificate K-PCE-310-TF replacement temperature sensor K-CAL-SET-RF calibration set 33 % / 75 % RH
K-CAL-SET-RF calibration set 33% / 75% RH K-CAL-PCE-HT110 ISO calibration certificate K-CAL-PCE-320 ISO certificate (RH / IR)
K-CAL-SET-RF calibration set 33% / 75% RH For other sensors see page 11

28 www.pce-instruments.com/us
Digital Thermometer
PCE-313 A PCE-G1 and PCE-G1A
Professional Climate Meter with SD Card Memory / Data Logger Display for Temperature and Humidity
• measures temperature and humidity by internal sensor and temperature by K type thermocouple • visible from distances of up to 50 m
• calculates the dew point and wet bulb temperature • clearly readable LED digits with a height of 100
• internal real-time memory via SD card (1 ... 16 GB) • the measured temperature and humidity values are
• the stored data are saved directly to the SD card in Excel format displayed in turns

• 2 GB SD card and card reader included in the delivery • 4 ... 20 mA output / quick response time

• optional software to transfer data to the PC in real time • long-term stable sensor
(software is not needed to analyse the stored data) • IP 54 protection
• PCE-313 S model includes sintered cap

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS


Meas. range RH: 5 ... 95 % / Temperature: internal sensor 0 ... +50 °C / K type -50 ... +1300 °C Meas. range 10 ... 95 % RH / 0 ... +60 °C
Resolution 0.1 % RH / 0.1 °C Resolution 1 % RH / 1 °C
Accuracy RH: ±3 % at >70 % RH / ±3 % of reading ±1 % at <70 % RH Accuracy ± 2 % RH / ± 1 °C
Temperature (internal sensor): ±0.8 °C / Temperature (type K): ± 0.4 % + 0.5 °C Sensor capacitive / Pt1000 / 1 m cable
Memory SD card (1 ... 16 GB) Output 4 ... 20 mA
Measurement rate 1 ... 3600 s (adjustable) Response time 4s
Interface RS-232 Display LED 100 mm
Display LCD Visibility from approx. 50 m
Operating cond. 0 ... +50 °C, < 85 % relative humidity Power supply 230 V / 50 ... 60 Hz
Power supply 6 x 1.5 V batteries Dimensions sensor: 50 x 70 x 20 mm
Dimensions 177 x 68 x 45 mm display: 175 x 175 x 75 mm
Weight 490 g Weight 1300 g
INCLUDES INCLUDES
Thermohygrometer, combined temperature and humidity sensor, SD memory card (2 GB), card reader, batteries, Display, sensor for RH and temperature, mains cable,
instruction manual instruction manual
ITEM NO. ITEM ITEM NO. ITEM
K-PCE-313A thermohygrometer K-PCE-G1 display
OPTIONAL ACCESSORIES K-PCE-G1A display with analogue output

K-PCE-313 S thermohygrometer / data logger (like PCE-313 A), with sintered cap OPTIONAL ACCESSORIES
K-SOFT-LUT-B02 RS-232 data cable with software to transfer data in real time K-CAL-PCE-G1 ISO calibration certificate
K-CAL-PCE-HT110 ISO calibration certificate
K-CAL-SET-RF calibration set 33% / 75% RH

1-800-TEST-INSTRUMENTS 29
Digital Thermometer
PCE-OWL Series PicoLite PCE-TD 60
USB Temp. Logger for Transport Disposable Data Logger USB Temperature Data Logger
• full-scale temperature determination • high-precision internal temperature sensor • Internal sensor / works with lithium battery
• fixed alarm values for refrigerated transport • direct USB interface for PC connection • integrated display for up-to-date values
• protection class IP 67 • can be used with free DataSuite software for data • internal memory of up to 32000 values
• possible operating systems: Win XP ... Win 8 analysis and alarm • sampling rates of 1 s ... 6 hrs selectable
• software available at • service life of 6 months at sampling rate 1 minute • time-specific data logging programmable
www-pce-instruments.de/deutsch • water- and dustproof according to IP67 • programmable optical alarm

TOP
seller

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS


Model Life Sampling rate (adjustable) Meas. range -40 ... +40 °C Meas. range -40°C ... +85 °C
PCE-OWL 6 6 days 1 / 2 / 3 / 5 / 6 min. Accuracy 0.5 °C Accuracy ±0.6 °C (-20 ... +50 °C),
PCE-OWL 60 60 days 1 / 2 / 3 / 5 / 6 min. Memory 16000 values ±1.2 °C (rest of range)
Measurem. range -30 ... +70 °C Sampling rate adjustable from 1 minute ..18 hrs Sampling rate 1 s ... 6 h
Accuracy / Resol.±0.5 °C (at -20 ... +40 °C) / 0.1 °C Activation via software Memory 32000 sets of data
Alarm PCE-OWL 6: -2 ... +4 °C / Display LED to display sampling and alarm Display LCD 3 digits
PCE-OWL 60: +2 ... +8 °C Interface USB 2.0 LED: flashing green-red: measuring
Interface USB 2.0 interface Power supply Battery CR2032 flashing red: below or above
Display 2 LED indicators (blue / red) Battery life up to 6 months measurement range
Memory 14400 measuerd values Protection class CE, EN12830, IP67 Power supply lithium battery 3.6 V, 1/2 AA
Operating cond. -30 ... +70 °C Dimensions 74 mm x 30 mm x 13 mm Operating conditions 0 ... +50 °C, <80 % RH
Dimens. / weight 80 x 48 x 5.8 mm / 11.5 g Weight 15 g Dimensions 135 x 28 mm, with cap
INCLUDES INCLUDES INCLUDES
Data logger, protective cover, instruction manual Data logger, instruction manual USB temperature logger, battery, box, strap, manual
ITEM NO. ITEM ITEM NO. ITEM ITEM NO. ITEM
K-PCE-OWL 6 disposable data logger, 6 days K-PICOLITE cold chain data logger K-PCE-TD 60 USB data logger
K-PCE-OWL 60 disposable data logger, 60 days OPTIONAL ACCESSORIES
K-CAL-T1 ISO calibration certificate

www.pce-instruments.com/english 43
Digital Thermometer
PT-DPM
Dew Point Meter for Identifying Critical Climatological Conditions in Surface Coatings
Probe head with a separate surface temperature
• two models / large display (rotatable 180 °) / interchangeable probe head
probe:
• 6 measurement parameters / internal memory / Automatic Log mode / various display languages
• norms: ISO 8502-4 / BS 7079-B4 / ASTM D3276-05 / NSTM 009-32 / IMO PSPC / SSPC-PA7 - includes integrated air temperature / humidity probe
and K type plug
- magnetic surface temperature probe with armoured
cable and locking to prevent unintentional uncoupling
from the instrument during unsupervised operation
- includes a magnetic mount to fix the dew point meter
to steel structures
- compatible with other K type temperature probes

TOP
seller

TECHNICAL SPECIFICATIONS
Standard (PT-DPM1) Advance (PT-DPM3) Parameter Range / Accuracy / Resolution
- LC display Monochrome Colour Surface temp. -40 ... +80 °C / ±0.5 °C / 0.1 °C
- Memory capacity 2500 in one group 20000 in up to +40 ... +190 °C / ±1.5 °C / 0.1 °C
1000 groups Air temperature -40 ... +80 °C / ±0.5 °C / 0.1 °C
- Battery life of rechargeable battery 50 hours up to 8 months Relative hum. 0 ... 100 % / ±3 % / 0.1 %
- Auto-Log mode for 5 parameters in Operating cond. -40 ... +80 °C
user-defined time intervals . Works Power supply 3 x 1.5 V AAA Alcaline
with battery or continuously via USB without supervision included included batteries
- Batch annotation - to create descriptive names and Dimensions 178 x 64 x 31 mm
enter the batch notes directly to the device not included included Weight 185 g without batteries
- Stream data logging via USB or Bluetooth
in fixed Auto Log intervals, ideal for remote supervision not included included
- Trend charts, measurement values in real time not included included INCLUDES
- user-defineable limit values for all parameters, Dew point meter, probe head (int. surface) USB cable,
with acoustic and visual alarms not included included probe protection cap, protective holster, batteries, case,
- WiFi technology for synchronisation with PosiTector.net, NIST calibration certificate (ISO equivalent), instruction
download of software updates and connection with mobile manual
devices for increased performance (available in Appstore) not included included ITEM NO. ITEM
- Wireless Bluetooth technology for data transfer to
PC or portable printer not included included K-PT-DPM1-E standard dew point meter
- Online help, real-time images, charts and batch notes not included included K-PT-DPM3-E advance dew point meter
OPTIONAL ACCESSORIES
K-PRBDPM-B replacement probe head

50 www.pce-instruments.com/us
Digital Thermometer
PCE-TA 30 PCE-007 PCE-THA 10
Vane Anemometer with Flexible Probe Vane Anemometer w. External Probe Anemo-Thermo-Hygrometer
• measures wind velocity, temperature and volume • calculates and displays volume flow • measures wind velocity and calculates air flow rate
flow • memory capacity for 2000 values • saves up to 20 readings (can be read out in the
• flexible 400 mm probe / selectable units • RS-232 interface / incl. software and data cable display)
• LCD indicates wind velocity and temperature at the • display units: m/s, ft/min, knots, km/h, mph
same time
• dual LCD / MIN, MAX, HOLD function
• MAX and MIN value indication / DATA HOLD
function

TOP
seller

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS


Wind velocity 1.0 ... 30 m/s Wind velocity 0.3 ... 45 m/s Temperature
Temperature -10.0 ... +60.0 °C Temperature 0.0 ... +45.0 °C Meas. range -15 ... +50 °C
Volume flow 0.0 ... 999900 ft3/min (calculated on Volume flow 0.0 ... 999900 m3/min (calculated on Wind velocity
the basis of velocity and surface after the basis of velocity and surface after Meas. range 0.4 ... 30 m/s, 80 ...5900 ft/min
entering the cross section) entering the cross section) Accuracy ±3 %
Resolution 0.01 m/s; 0.1 °C; 0.1 ft3/min Resolution 0.01 m/s; 0.2 °C; 0.001 ... 100 m3/min Units m/s, ft/min, km/h, knots, cm/s, air flow r.
Accuracy ±3 % ±0.2 of reading ±1.5 °C Accuracy ±3 % ±0.1 of reading ±1 °C Meas. range 0 ... 9.999 m³/s (air flow rate)
Ø vane 27.2 mm Ø vane 50 mm / plastic Air humidity
Display LC display Memory / softw. 2000 values / included, RS-232 Meas. range 5.0 ... 95.0 % RH
Propeller plastic Display 4 digits, dual LC display Accuracy ±3 % RH at +25 °C; otherwise ±5 % RH
Power supply 1 x 9 V block battery Power supply 1 x 9 V PP3 battery (typ. 50 h) Memory up to 20 sets of data
Operating cond. probe: 0 ... +50 °C / <80 % RH Operating cond. 500 mbar ... 2 bar / 0 °C ... +60 °C Power supply 3 x AAA batteries
Dimens. / weight sensor: 35 x 400 mm / 257 g (total) Dimens. / weight sensor: 60 x 130 x 25.5 mm / 350 g Dim. / weight 244 x 77 x 43 mm / approx. 200g
INCLUDES INCLUDES INCLUDES
Vane anemometer with flexible probe, battery, storage Anemometer with external vane, English software, data Anemo-thermo-hygrometer, batteries, USB cable,
box, instruction manual cable, battery, instruction manual storage box, bag, instruction manual
ITEM NO. ITEM ITEM NO. ITEM ITEM NO. ITEM
K-PCE-TA 30 vane anemometer K-PCE-007 vane anemometer K-PCE-THA 10 anemo-thermo-hygrometer
OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES
K-CAL-AM ISO calibration certificate K-RS232-USB adaptor RS-232 to USB
K-CAL-AM ISO calibration certificate

168 www.pce-instruments.com/us

You might also like