Controller Programming Manual 20221125
Controller Programming Manual 20221125
VOTOL CONTROLLER
To program the controller, you must have the following power supplies active
The controller must be powered up by the power supplier line(Gray/Purple) with Elock+ (above 35V) for debuging .
eLOCK
GREY/PURPLE
Choose the USB connection port and click on the “OPEN” button. It will go to “CLOSE” state and then
click on “CONNECT”. The parameters will pop out once it is connect successfully.
It may pop out abnormal connection or unable to connect if the USB cable is not connected well or
the controller is not powered on.
Attention:
1, The controller will not output if it detect the voltage is higher than the overvoltage value or
Indicate the maximum and minimum values allowed (according lower than the undervoltage value. It will report the fault code accordingly.
to the battery parameters) 2, The value of undervoltage and overvoltage must be set according to the battery spec to avoid
Default +2V for over voltage select, while default +1V for under the hazard the battery cell and BMS components.
voltage select
Soft undervoltage:
The controller determines the current voltage value, which is
3V higher than the battery undervoltage value. If the current
voltage value is lower than the soft undervoltage value, the
controller output is immediately switched off to protect the
battery.
Undervoltage variation:
Para evitar medidas incorrectas por parte del controlador, se incrementa el valor de la tensión “undervoltage” para no provocar un daño en el pack de baterías. Normalmente se
suele marcar 1V, pero es posible aumentar dicho valor si queremos tener más seguridad.
To avoid incorrect measurements by the controller, the value of the "undervoltage" voltage is increased so as not to cause damage to the battery pack. Normally set with 3V, but
it is possible to increase this value if we want to have more security.
Busbar Current
Busbar Current
Corriente máxima permitida de alimentación al controlador.
El límite del controlador es 100A (72V)
Potencia máxima = 72V x 100A = 7200W = 7,20kW
Maximum allowable power supply current to the controller. Controller limit is 100A Phase Current Limited Value
(72V)Maximum power = 72V x 100A = 7200W = 7.20kW
Phase current = 9600
Especificar este valor y no modificar.
Specify this value and do not modify.
2. Starting voltage: Valor del voltaje a partir del cual el motor comienza a funcionar (sería el
punto del 0% del acelerador). Voltage value from which the motor starts to work (it would
be the 0% throttle point).
3. End voltage: Este valor marca el valor de tensión que establece el 100% del acelerador. Todo
valor de tension superior, se seguirá considerando 100%. This value marks the voltage value
that establishes 100% throttle. Any higher voltage value will continue to be considered
100% (The upper limit of the speed effective value, the max. speed value voltage.)
4. High protection value: Cuando el valor de tension sobrepasa este valor, aparece un error en
la señal del acelerador (valor muy alto). When the voltage value exceeds this value, an error
appears in the throttle signal (value too high).
100%
voltage
Throttle
signal
0%
• Start torque: Torque parameter at startup, usually set to 0 and not changed.
• Combinative torque: Starting delay parameter, the range is 0-350. The larger the
value, the more obvious the effect of the starting delay.
• These two parameter above is effective for middle motor with gear
• rate of rise : Acceleration slope, the range is 10-255, the larger the value, the faster
acceleration.
• rate of decline: Deceleration slope, 10-200 range value, the larger value, the more
obvious the speed drop, and the inertia of the loosening handle is reduced.
CONSIGNA DE PAR /
100% TORQUE SETPOINT • ST = Start Torque Rate of rise = tg(A)
• Rango de regulación / Regulation range = 10-250
A • A mayor pendiente, más rápida es la respuesta (más rápido se alcanzará la
consigna de par). The greater the slope, the faster the response (the faster the
torque setpoint will be reached)
SEÑAL ACELERADOR / • Rate of decline = tg(B)
100% THROTTLE SIGNAL
• Rango de regulación / Regulation range = 10-200
B • A mayor pendiente, más rápida es la respuesta (más rápido se alcanzará la
consigna de par). The greater the slope, the faster the response, the release
speed of the handlebar drops faster (the faster the torque setpoint will be
ST reached)
0% TIME
THROTTLE SIGNAL
Modulation of the time
∆t to reach the maximum
torque (100%)
∆Par
• Combinative torque
o Rango de regulación / Regulation range = 0-350
o As the value increases, more time is needed to reach the maximum torque
setpoint. In this way, the behavior of the motor, in terms of acceleration, is
smoothed out.
o If the value 0 is specified, it means that there is no modulation, so the slope
RATE OF RISE defined as Rate of Rise is followed until the torque setpoint is reached.
TIME
When controller turn into S gears, the motor will be in flux weaken condition, speed increased.
Setting value range is determined by motor condition:
The hub motor is 10~20, this parameter can adjust the size
of the reverse torque.
Top Speed in rpm HHC just suit for three wheeler, not works for two wheelers.
when HHC enabled, the vehicle will hold still when switching from the brake to
throttle pedal.
Escoger el tipo de mando que establece los 3 modos de Choose the type of control that establishes the 3 operating
funcionamiento: modes:
• Button = Botón mediante el cual se establece el modo en Button = Button through which the mode is set based on the
función del número de veces que se presione number of times it is pressed
Switch = Interruptor de 3 posiciones Switch = 3 position switch
Soft start selection, not hard start, the higher the level, the more
obvious the starting power.
En el caso de escoger “Button 3 speed”, establece la marcha que se activa por defecto.
In the case of choosing “Button 3 speed”, it establishes the gear that is activated by default.
Choose the default gear
Motor rotor magnet fixing type, Phase shift angle adjustment angle, in hub
the hall position in-hub motor motor usually with -60.
The controller to speedometer date output has 2 types: LIN protocol speedometer and
hall speedometer, it needs to be decided by the vehicle’s speedometer. We provide
standard LIN protocol speedometer.
If we use CAN protocol, then we need to integrate with CAN speedometer.
。
The vehicle moving assist function is used for two-wheeled vehicles, the
speed is less than 3KM/H, and the torque is 9-19N.M.
Brake/Reverse/Lock
Open the ECU program file (bin file) or configuration file (ini file)
Download: Import the ECU program file or configuration file into the controller.
Remove failure
Calibration values:
Voltage calibration: adjust whether the displayed voltage is consistent with the actual voltage,
no need to change
Current calibration: adjust whether the displayed current is consistent with the actual current,
no need to change Weake flux value: adjust D-axis voltage and Q-axis current ,without
changing
For V1 motor:
• When temperature is over 120°C, the controller shut down.
• When temperature less than 100°C, the controller work again.
Shows the value of the rotation rpm of the motor rotor in real time
Shows te value of the supply voltage to the controller in the rear time
Show the current value of the supply to the controller in real time
(bus current value)
Q-axis voltage: the range is 2000-3000 when the motor angle is correct
D-axis voltage: the range is -600 to -1000 when the motor angle is correct (may fluctuate slightly)
After the weakening flux is adjusted to the final speed, adjust the D-axis voltage by
adjusting the value of the weakening flux coefficient, the normal range is 0 to -300.
D-axis current: corresponds to the desired weakening flux value at the current speed.
If it is close to 0, weakening flux is not required for the current speed.
If with 500, the current speed needs 500 weakening flux to reach.
NOTE: The weakening flux value corresponds to the weakening flux value for the corresponding gear on
page 2 of settings.
ISDN 一线通
ISDN Parking
One speed 1速
Temperature control 温控
Sport gear S档
Thank you
for using
VOTOL USER MANUAL FOR PARAMETER SETTING VOTOL V.0 47