Solutions To High TCH Call Drop Rate

The document discusses solutions to high TCH call drop rates in BSCs. It describes checking hardware, transmission issues, and radio resource availability as potential causes. Traffic measurements and alarms are mapped to troubleshooting procedures to diagnose the root cause.

Uploaded by

mwaka emmy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views3 pages

Solutions To High TCH Call Drop Rate

The document discusses solutions to high TCH call drop rates in BSCs. It describes checking hardware, transmission issues, and radio resource availability as potential causes. Traffic measurements and alarms are mapped to troubleshooting procedures to diagnose the root cause.

Uploaded by

mwaka emmy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

1.

1 Solutions to High TCH Call Drop Rate


Before analyzing the causes of high TCH call drop rates, you should find out the
difference between the actual TCH call drop rate and the expected value. You
should also find out the impact of the problems and the related KPIs.
You can analyze the distribution of call drops based on the traffic measurement. If
a certain type of call drop accounts for a large proportion of total call drops, you
can locate the fault by performing the corresponding procedure. If no obvious
causes are found, you can perform the procedures shown in Ошибка! Источник
ссылки не найден.. The following table lists the mapping between the traffic
measurement counters and the troubleshooting procedures.

Traffic Measurement Counter Troubleshooting Procedure


M3100A (T200 expiry) Ошибка! Источник ссылки не
найден.Ошибка! Источник ссылки не
найден.
M3101A (radio link failure) Ошибка! Источник ссылки не
найден.Ошибка! Источник ссылки не
найден.
M3101D (radio resource unavailable) 1.1.1 Checking the Hardware
CM333 (Abis terrestrial link 1.1.2 Checking the Transmission
failure)
M314 (device failure) 1.1.1 Checking the Hardware

The following sections describe the solutions to high TCH call drop rates.
The traffic measurement counters and KPIs in this document are the same as
those in the BSC6000V9R8C01B051 version.

1.1.1 Checking the Hardware


If a TRX or a combiner is faulty or if an RF cable is incorrectly connected, seizing
the TCH becomes difficult, and thus the TCH call drop rate increases. See
Ошибка! Источник ссылки не найден..

You can check whether hardware is faulty by viewing BTS alarms or viewing the
hardware state on the Site Device Panel of the LMT. Table 1-1 lists the major BSC
alarms related to hardware failures.

Table 1-1 Major BSC alarms related to hardware failure


Alarm ID Alarm Name
1000 LAPD_OML Fault Alarm
2204 TRX Communication Alarm
4414 TRX VSWR Alarm

3606 DRU Hardware Alarm

In addition, you can locate the fault by checking the traffic measurement related to
hardware failures.

Cause BSC Level Cell Level

Equipment Access Measurement per BSC KPI Measurement per Cell:


failure in BSC Measurement: TCH Availability
Available TCHs per BSC Available TCHs
Configured TCHs per BSC Configured TCHs
Available TCHs per BSC TRX Measurement per Cell:
Number of configured TRXs in a
cell
Number of available TRXs in a
cell
Call Drop Measurement per Cell
in Call Measurement:
Call Drops due to Equipment
Failure (TCH)

1.1.2 Checking the Transmission


Poor transmission quality, unstable transmission links, or insufficient resources on
the Abis and A interface may lead to the increase of the TCH call drop rate. You
can check the transmission conditions by viewing the alarms related to
transmission. If a large number of transmission alarms are generated, you can
infer that transmission failure has occurred. Then, you should check the
transmission connections. See Ошибка! Источник ссылки не найден..

Table 1-2 BSC alarms related to transmission

Alarm ID Alarm Name


1000 LAPD_OML Fault Alarm
11270 LAPD Alarm
11278 E1 Local Alarm
11280 E1 Remote Alarm
20081 Loss of E1/T1 Signals (LOS)
20082 E1/T1 Frame Out-of-Synchronization (LOF)

In addition, you can locate the fault by checking the traffic measurement related to
transmission failures.

Cause BSC Level Cell Level

Transmission failure LAPD Measurement in Channel Activation


BSC Measurement Measurement per Cell in Call
Measurement:
CHAN ACTIV NACK
Messages Sent by BTS
Channel Activation Timeouts
Call Drop Measurement per
Cell in Call Measurement:
Measurement of Call Drops
Due to Abis Terrestrial Link
Failure