Shimizu Bim For Construction 20190515
Shimizu Bim For Construction 20190515
Shimizu Bim For Construction 20190515
SHIMIZU VIETNAM
Application of in construction
SHIMIZU CORPORATION
SHIMIZU VN BIM
1 2a 2b 3 4
OWNER
Movie ASME
BoQ
B.I.M
Perspective Coordinate
Design
Drawing
Construct. Shop drawing
Clashing Method &BBS
feedback
SHIMIZU CORPORATION
Application of in construction
SHIMIZU CORPORATION
TEMPORARY PLAN
SHIMIZU CORPORATION
TEMPORARY PLAN
Scaffolding Schedule
Scaffolding Erection Sequence
Scaffolding Plan Elevation
SHIMIZU CORPORATION
CONSTRUCTION SEQUENCE
SHIMIZU CORPORATION
4D MASTER SCHEDULE
SHIMIZU CORPORATION
4D MASTER SCHEDULE
SHIMIZU CORPORATION
4D DAILY Real time schedule control
SHIMIZU CORPORATION
REBAR CONTRONL - BAR BENDING SCHEDULE
Preassembly rebar
A
3D coordination model
= A+S+MEP
S MEP
SHIMIZU CORPORATION
PROJECT COORDINATION
SHIMIZU CORPORATION
SHOP DRAWING
S
STR model
Structural
Shop Drawing
(by Revit)
A
AR model
Finishing
Shop Drawing
(by Revit)
MEP model
MEP M&E
Shop Drawing
(by Revit)
SHIMIZU CORPORATION
SAMPLE PROJECT
SHIMIZU CORPORATION
Conclusion
BEP(BIM Execution Plan- kế hoạch triển khai BIM )
FOR
Aqua Central Project
BEP(BIM Execution Plan- kế hoạch triển khai BIM )
FOR
Aqua Central Project
By developing a BIM Execution Plan (BEP), the project and project team members can:
• clearly understand the strategic goals for implementing BIM on the project;
• understand their roles and responsibilities for model creation, maintenance and
• collaboration at different stages of the project;
• design a suitable process to participate in the implementation;
• define the content, level of detail and by when the model is to be delivered to
meet which objectives;
• benchmark the effectiveness of process with previous and future projects
• define contract language to ensure all project members fulfil their obligations
• provide a baseline plan to measure progress throughout the project
Section A: Project Information
1.Project Owner: Hanoi Water Tower JSC.,
2.Project Name: HANOI AQUA CENTRAL PROJECT
3.Project Location and Address:44 Yen Phu Street, Hanoi
4.Building's purpose : Multi-Purpose building includes : Commercial center, Residential
apartment, Hotel block for long-term lease
5.Project Numbers: VN51-16
Section A: Project Information NAME LEVEL
(STRUCTURE)
B3 -17.10
B2 -9.50
B1 -4.65
1FL 0.00
2FL 6.70
3FL 12.70
4FL 19.00
5FL 22.20
6FL 25.40
7FL 28.60
8FL 31.80
9FL 35.00
10FL 38.20
11FL 41.40
12FL 44.60
13FL 47.80
14FL 51.00
15FL 54.20
16FL 57.40
17FL 60.60
18FL 63.80
19FL 67.00
20FL 70.20
21FL 73.40
22FL 76.50
TUM 79.55
RFL 82.55
Section B: Project member
1.BIM PROJECT MEMBER:
ROLE ORGANIZATION CONTACT NAME LOCATION E-MAIL PHONE
Site office/
BIM Manager Shimizu P.T.Giang [email protected] 0906244086
HN office
BIM Site office/
Shimizu N.T.Duong [email protected]
Coordinator(A&S) HN office
BIM Site office/
Shimizu N.D.Thai [email protected]
Coordinator(M&E) HN office
BIM Coordinator
(sub-con A)
BIM Coordinator
(sub-con S)
BIM Coordinator
(sub-con M&E)
Section B: Project member
1.BIM PROJECT MEMBER CSA:
BIM BIM BIM BIM MODELER BIM MODELER BIM BIM MODELER BIM MODELER BIM
MODELER 1 MODELER 2 MODELER 3 MODELER 6 MODELER 3
(ARC) (ARC) (ARC) 4 (ARC) 5 (ARC) (ARC) 1 (STRUC) 2 (STRUC) (STRUC)
BIM BIM
MODELER 7 MODELER 8
(ARC) (ARC)
9 STAFFS 4 STAFFS
Section B: Project member
1.BIM PROJECT MEMBER MEP:
BIM COORDINATOR
(MECHANICAL) BIM COORDINATOR (ELECTRICAL)
6 STAFFS 3 STAFFS
Section B: Project member
2.BIM ROLES AND RESPONSIBILITIES:
ROLE RESPONSIBILITIES IN MODEL MANAGEMENT BIM RESPONSIBILITIES
STRUCTURAL M&E
DESIGNER DESIGNER
(CPG) (CPG)
DWG,PDF
STR CONTRACTOR
BIM Modeler
Modeler
2D
AR SUB-CON Drafter
coordinator SUB-CON
LIFT, ESCALATOR
FIRE
4.BIM USES:
- DESIGN REVIEWS
- 3D COORDINATION
- SHOP DRAWING
- RECORD MODELING (AS-BUILT)
Section D: Scope During Construction stage
BIM USE ORGANIZATION CHART:
Scope During Construction stage AUTHOR USER
Quality: BIM element is modeled with fabrication and assembly details where applicable or useful for
construction works; otherwise, details may be represented in 2D CAD drawings to complement the Detailed
Design models
Essential: Produce Construction Models from Architectural, Structural and MEP
Main
Expected Deliverables : ALL
Contractor
Construction Models with Key Services Coordinated.
Essential: Produce schedules of materials, areas and quantities from the BIM databases for
contractors’ reference
Main
Expected Deliverables ALL
Contractor
Schedules of materials, areas and quantities
Note: Schedule of material and quantity will be indicated in only selected shop drawing
Essential: Sub-contractors and specialist sub-contractors will generate documents based
on the Construction Models
Expected Deliverables
Main
Shop drawings (A&M&E) ALL
Contractor
Fabrication models and drawings
Combined Services Drawings (CSD)
Single Services Drawings (SSD)
Essential: Contractors should provide the latest record model and drawings to the
consultant if the consultant is required to do an amendment submission.
Expected Deliverables Main
ALL
Record model Contractor
Record model-generated drawings
Other non-BIM deliverables
Section E: Project Deliverables
1.FILE FORMAT:
BIM SUBMITTAL ITEM FORMAT NOTES
Design DWG&PDF From CPG
Model A for shop drawing REVIT version 2017(.RVT)export to DWG,PDF
Model S for Coordinator REVIT version 2017(.RVT)
Model M&E for Coordinator REVIT version 2017(.RVT)
Combined coordination model Navisworks 2014 (nwf or nwd)
Clash Detection Report Navisworks (html), PDF
Sample: SVN-AQUA_A_1F
Section E: Project Deliverables
3.MODEL OVER VIEW
Coordination Coordination
Section E: Project Deliverables
4.MODEL STRUCTURE
Structural model is divided into 5 Model 4
models. 21F~RF
Model 1
B3~1FL
Section E: Project Deliverables
4.MODEL STRUCTURAL
Model FILE NAME FLOOR 3D file
1 SVN-AQUA_S_B3~1FL B3~1FL Structural model
2 SVN-AQUA_S_2FL~4FL 2FL~4FL Structural model
3-6 SVN-AQUA_S_5FL~20FL 5FL~6FL Structural model
7 SVN-AQUA_S_21FL~RFL 21FL~RFL Structural model
Model 1
B3~1FL
Section E: Project Deliverables
5.MODEL ARCHITECTURAL (FOR GENERATE SHOP DRAWING)
1/SVN-AQUA_A_B3~1FL
6/SVN-AQUA_A_RLL
7.1/SVN-AQUA_A_U-B1
7.2/SVN-AQUA_A_U-B2-1,B2-2
7.3/SVN-AQUA_A_U-B3
7.4/SVN-AQUA_A_U-B4
7.5/SVN-AQUA_A_U-B5
7.6/SVN-AQUA_A_U-B6
7.7/SVN-AQUA_A_U-B7
7.8/SVN-AQUA_A_U-B8
7.9/SVN-AQUA_A_U-B9
7.10/SVN-AQUA_A_U-B10
7.11/SVN-AQUA_A_U-B11
Section E: Project Deliverables
5.MODEL ARCHITECTURAL
FLOOR 2D drawings generating from
Model FILE NAME
3D file
1 SVN-AQUA_A_ B3~1FL B3~1FL GFP, RCP
2 SVN-AQUA_A_2FL~4FL 2FL~4FL GFP, RCP, ELEVATIONS
3.1 SVN-AQUA_A_5FL~6FL 5FL~6FL GFP, RCP
3.2 SVN-AQUA_A_7FL~9FL 7FL~9FL GFP, RCP
3.3 SVN-AQUA_A_10FL~12FL 10FL~12FL GFP, RCP
3.4 SVN-AQUA_A_13FL~19FL 13FL~19FL GFP, RCP
3.5 SVN-AQUA_A_20FL 20FL GFP, RCP
4 SVN-AQUA_A_21FL~RFL 21FL~RFL GFP, RCP
5 SVN-AQUA_A_UBLKA -XX-XX Varies GFP, RCP,UNIT
6 SVN-AQUA_A_RLL-XX-XX Varies GFP, RCP, ELEVATIONS
7 SVN-AQUA_A_ UBLKB -XX-XX Varies GFP, RCP,UNIT
8 SVN-AQUA_A_HLL-XX-XX Varies GFP, RCP, ELEVATIONS
9 SVN-AQUA_A_STA-XX-XX Varies GFP, RCP,
10 SVN-AQUA_A_TOI-XX-XX Varies GFP, RCP,
Worksets
Tread Block
A_ BRICKWALL
A_ FINISHING
A_ DOOR&WINDOW
A_ FURNITURE
A_ SANITARY
A_ CEILING
Section E: Project Deliverables
6.MODEL MEP
Model FILE NAME FLOOR 3D file
1 SVN-AQUA_ME_B3~1FL B3~1FL M&E model
2 SVN-AQUA_ME_2FL~4FL 2FL~4FL M&E model
3 SVN-AQUA_ME_5FL~20FL 5FL~20FL M&E model
4 SVN-AQUA_ME_21FL~RFL 21FL~RFL M&E model
5 SVN-AQUA_ME_LIFT LOBBY All M&E model
1. ACMV SYSTEM.
2. PUMB SYSTEM.
3. FIRE FITING SYSTEM.
4. ELECTRICAL SYSTEM.
5. COMBINE
SECTION F:MODEL ELEMENT DELIVERABLE
MODEL ELEMENT
Elements 3D 2D
Site Model Site infrastructure within site boundary ⃝ 2
(roads, pavements, car park spaces, access and parking arrangements and surrounding land use)
Surface drainage (only indication of locations necessary) ⃝
External drainage & underground drainage ⃝ 2
Hard landscaped areas within site boundary ⃝ 2
Planter boxes including sub-soil drainage systems ⃝
Rooms /Spaces Room spaces ⃝ 2
Walls and Interior / Exterior walls / Non-structural walls / Blockwork walls (Including finishes to identify if tiled / painted / ⃝ 2
Curtain Walls plastered)
Studs* and individual layers of drywall ⃝
Curtain wall with mullions and window glazing units including shading devices ⃝ 2
Doors, Windows and Interior / Exterior doors ⃝ 2
Louvers Interior / Exterior windows ⃝ 2
Louvers ⃝ 2
Ironmongery (handles, locks*, hinges* etc) ⃝
Roofs Roofs with overall thickness (including finishes & insulation) ⃝ 2
Ceilings Ceilings (without support sub-frames) including module arrangement, materials. ⃝ 2
Hangars and sub-frames for ceilings* ⃝
Floors Horizontal floors ⃝ 2
Sloped floors and ramps ⃝ 2
Raised floor (without support) ⃝ 2
Vertical Steps & stairs including risers, threads and railings including headroom clearance requirements ⃝ 2
Circulation Elevator shafts (without fit-out installations by lift contractor) ⃝ 2
Escalators & moving walkways, not including motorized equipment inside. ⃝ 2
Access ladders and catwalks ⃝ 2
Architectural Specialties Building Maintenance Units (BMU) ⃝ 1
and Casework
Fixtures and Equipment* Casework & cabinets ⃝ 2
(with input from interior Appliances such as in kitchen equipment ⃝ 2
designers, specialist sub- Toilet fixtures, plumbing faucets ⃝ 2
contractors, etc) Irrigation pipe ⃝
Signage ⃝
* These elements may cause BIM models to become too big and unmanageable.
SECTION F:MODEL ELEMENT DELIVERABLE
2. STRUCTURAL BIM ELEMENTS
(ii) Structural BIM ElementBIM Elements Geometry Component
type grade
s
3D 2D
Foundations ⃝ 2
Beams ⃝ 2
Columns ⃝ 2
Walls ⃝ 2
Slabs including recesses, kurbs, and major penetrations ⃝ 2
Stairs (steps, risers, threads, landings): all framing members and openings ⃝ 2
Shafts and Pits (and openings) ⃝ 2
Concrete reinforcement details (Rebar), imbeds and cast-ins* ⃝
Steel frame structures ⃝ 2
Base plates, bolts, clip angles, fixings, etc.* ⃝
Connection details of structural steel members* ⃝
* These elements may cause BIM models to become too big and unmanageable.
SECTION F:MODEL ELEMENT DELIVERABLE
3.1. ACMV BIM ELEMENTS
(ElementBIM Elements Geometry type
Elements 3D 2D
ACMV Equipment Air Handling unit ⃝ 2
Chiller unit ⃝ 2
Variable refrigerant unit ⃝ 2
Cooling Tower ⃝ 2
Exhaust or extract air fans ⃝ 2
Fresh air fans ⃝ 2
Other fans such as jet fans ⃝ 2
Heat Exchanges for projects with District Cooling ⃝ 2
ACMV Distribution Exhaust air ducts (excluding hangars) ⃝ 2
Fresh air ducts (excluding hangars) ⃝ 2
Supply air ducts (excluding hangars) ⃝ 2
Return air ducts (excluding hangars) ⃝ 2
Transfer air ducts (excluding hangars) ⃝ 2
Diffusers, air-boots, air grilles, air filters, registers ⃝ 2
Fire dampers, motorized dampers, volume control dampers, CO2 sensors, CO sensors ⃝ 2
Mechanical Piping Chilled water supply pipes including connections, fittings & valves ⃝ 2
Chilled water return pipes including connections, fittings & valves ⃝ 2
Condensate drain pipes including connections, fittings & valves ⃝ 2
Others Switch boards, control, BMS & DDC panels, BMS control & monitoring modules ⃝ 2
Fan Coil unit ⃝ 2
Engineering Smoke Extract System (e.g. smoke curtains, ductless fans) ⃝ 2
SECTION F:MODEL ELEMENT DELIVERABLE
3.2. PLUMBING AND SANITARY BIM ELEMENTS
(ElementBIM Elements Geometry type
Elements 3D 2D
General Pipe supports and brackets * ⃝
Pumps ⃝ 2
Control panels, monitoring and control sensors ⃝ 2
Plumbing BIM Elements Fresh water piping, fittings, valves including hot & cold water pipe work with all plumbing ⃝ 2
only equipment, sinks
Water meters ⃝ 2
Storage, water holding tanks, pressure vessels ⃝ 2
Underground Public Utilities for water supply ⃝ 2
Underground Public Utilities for drainage ⃝ 2
Grey water systems ⃝ 2
Pool filtration equipment ⃝ 2
Sanitary BIM Elements Foul drainage, kitchen waste pipe work including floor drains, open trapped gullies, sealed ⃝ 2
only trapped gullies and clean outs, vents and manholes
Grease and sand traps ⃝ 2
Sump and sewage pits ⃝ 2
* These elements may cause BIM models to become too big and unmanageable.
SECTION F:MODEL ELEMENT DELIVERABLE
3.3. FIRE PROTECTION BIM ELEMENTS
(ElementBIM Elements Geometry type
3D 2D
System piping, droppers, fittings, valves and sprinkler heads, sprinkler inlets, sprinkler control valve set, ⃝ 2
subsidiary valves, flow switches
Pipe supports and brackets * ⃝
Fire alarm gongs & break glass unit ⃝ 2
Fire sprinkler pumps ⃝ 2
Sprinkler tanks ⃝ 2
Hydrants and hose reels (location of street fire hydrant determined by architects) ⃝ 2
Gas piping for suppression systems ⃝ 2
Heat or smoke detectors, control panels, monitoring and control sensors, pump panels, check meter ⃝ 2
positions
Fire extinguishers ⃝ 2
Fire shutters & hoods above ⃝ 2
Smoke Curtains ⃝ 2
* These elements may cause BIM models to become too big and unmanageable.
SECTION F:MODEL ELEMENT DELIVERABLE
3.4. ELECTRICAL BIM ELEMENTS
Geometry Component
((ElementBIM Elements type grade
3D 2D
Cable trays, trunking & cable containment, Electrical risers, conduit, Busduct, power feeds, ⃝ 2
Outlets, panels, wall switches, circuiting to devices, security devices, card access and “plug moulds” (socket ⃝ 2
points)
HV & LV switch boards, switchgear, MCCB boards, MCB boards ⃝ 2
Transformers ⃝ 2
Light fittings & fixtures & housings for light fixtures ⃝ 2
Conduit associated with access, data communication, security systems and electrical equipment * ⃝ 2
Telecom equipment and computer racks ⃝ 2
Generators and exhaust flues including acoustic treatments ⃝ 2
Diesel tanks & fuel pipes ⃝ 2
Security system including CCTV camera, smart card system, door monitoring system ⃝ 2
Car park control system, barrier gates ⃝ 2
Equipment and associated installations maintained by public utility companies (Including manholes / drawpits ⃝ 2
for the Power Grid)
Earthing and lighting protection system ⃝ 2
Lifts, PA systems, BMS equipments including display panels (e.g. power consumption display) ⃝ 2
* These elements may cause BIM models to become too big and unmanageable.
SECTION G: PROCESS FOR BIM CREATION AND COLLABORATION
4. QUALITY CONTROL:
Validation
Sheets from the BIM shall be published to DWF (preferred), PDF or other non -editable format, where they can be
checked, approved, issued and archived as traditional documents.
Validation of the BIM data prior to sharing shall check that:
1) Model file has been audited, purged and compressed;
2) File format and naming conventions follow BIM execution plan,
3) Model files are up-to-date.
4) Model files are detached from central file,
5) Any linked reference files have been removed and any other associated data required to load the model file
is made available,
6) Model is correctly assembled through visual inspection,
7) Any changes since the last issue are communicated to the project team.
Data Security & Saving
1) Staff access to BIM project data held on the network servers shall be through controlled access permissions.
2) Maximum number of Revit back-ups shall be set to 3.
3) Revit LOCAL files shall be saved back to CENTRAL hourly.
4) Revit save reminder interval shall be set to 30mins. A 'Splash Page' is included in the associated templates .
These shall be retained and the file information completed. The note may be discarded or replaced with
project-specific information if required.
Reviewing BIM data
Untrained users shall not open Revit models directly. Instead, the model shall be exported as a 3D DWF and review
freely available Autodesk Design Review software shall be used for interrogation and mark -up.
Modelling Methodology
Follow Singapore BIM Guide Version 2.
SECTION G: PROCESS FOR BIM CREATION AND COLLABORATION
4. QUALITY CONTROL:
RESPONSIBLE SOFTWARE FREQUENC
CHECKS DEFINITION
PARTY PROGRAM(S) Y
2.COMPUTERS/ HARDWARE:
OWNER OF
BIM USE HARDWARE SPECIFICATIONS
HARDWARE
Equivalent or higher,
DESIGN AUTHORING SHIMIZU Intel® Xeon® W5590 (8M Cache, 3.33 GHz,
Desktop PC
Level 1 Simple model VIETNAM 6.40 GT/s Intel® QPI, 4 Cores)4GB of RAM
1.5G - NVIDIA Quadro FX 4800
Equivalent or higher
DESIGN AUTHORING
SHIMIZU Intel® Core™ i7-2720QM (6M Cache, 2.20
Level 2 Complex Laptop PC
VIETNAM GHz)16GB of RAM
model
2.0G - NVIDIA Quadro 2000M GDDR3
Coordination
SHIMIZU Intel Core i7-4900MQ Processor32 GB of RAM 4
Clash detection Laptop PC
VIETNAM GB NVIDIA Quadro K4100M
Technical meeting
Appendix A: Clash detection report
Export REVIT model to NAVISWORKS format (**.NWC) including the link file by using the following setting.
UNIT A1
ARC+STR+MEP COMBINATION
3. TRANSFORMER & MSB ROOM AT BASEMENT 1.
1. MAKE MODEL.
2. CHECK CLASHING.
3. EXPORT SHOPDRAWING.
4. REQUEST BUILDER WORKS.
Requires changing the door height to
transport and install transformers
ARC+STR+MEP COMBINATION
3. PUMB ROOM AT BASEMENT 1
24 storeys
4 basements