M001685-01 2
M001685-01 2
M001685-01 2
4 Software
GALILEO
GALILEO OPEN
MXpro
Additional software
EPAM
Contents
XV200 1/2
XV400 1/3
XVS400 1/4
XVH300 1/5
XVC600 1/6
XVC100 1/7
Accessories 1/8
Licensing 1/10
Technical data
XV200 1/14
XV400 1/16
XVS400 1/18
XVH300 1/20
XVC600 1/22
XVC100 1/24
Dimensions 1/27
Display Version front Screen Display Resolution Communication Type Price Std. pack
diagonal area interface Order No.
Inch mm Pixels See price
sheet
Device overview XV200
XV200
Processor RISC CPU, 32-bit, 200 MHz
HMI and HMI-PLC
Resistive touch, Standard film 5.7 115 x 86 320 x 240 CAN XV-230-57CNN-1-10 1 off
5.7" FSTN-LCD 85 28 200010
(monochrome display), Standard film 5.7 115 x 86 320 x 240 Profibus1) XV-230-57MPN-1-10
256 grayscales 85 28 200050
Standard film 5.7 115 x 86 320 x 240 RS232 XV-232-57BAS-1-10
85 28 200000
Resistive touch, Standard film 5.7 115 x 86 320 x 240 CAN, XV-252-57CNN-1-10
5.7" CSTN-LCD RS232 85 28 200510
(color display), Standard film 5.7 115 x 86 320 x 240 Profibus1), XV-252-57MPN-1-10
256 colors RS232 85 28 200550
Display Version Screen Display area Resolution Slots for Type Price Std.
front diagonal communi- Order No. pack
cation See price
modules sheet
Notes: 1) A LIC-HMI-EPAM-STD license product paper is required for operation of EPAM a Licensing.
2) Is also approved for IP69K
3) Is also approved for II 2G EEx p II IP5x (ATEX 94/9/EC):
- Zone 1, category 2G (only for mounting in a pressurized housing! Max. permissible pressure: 10 mbar continuous.)
- Zone 2, category 3G (only for mounting in a pressurized housing! Max. permissible pressure: 10 mbar continuous.)
Display Version front Screen Display area Resolution Type Price Std. pack
diagonal Order No.
Inch mm Pixels See price
Device overview XVS400
sheet
XVS400
Processor RISC CPU, 32-bit, 400 MHz
HMI and HMI-PLC
Display Version front Screen Display Resolution Communication Type Price Std. pack
diagonal area interface Order No.
See price
XVH300
IR touch Standard film 5.7 115 x 86 320 x 240 CAN XVH-340-57CAN-1-10 1 off
(infra-red light matrix), 85 16 200610
robust, scratchproof front Standard film 5.7 115 x 86 320 x 240 Suconet K, XVH-342-57SKS-1-10
(safety glass) RS 232 85 16 200950
Resistive touch, Standard film 5.7 115 x 86 320 x 240 CAN XVH-330-57CAN-1-10
absolutely flat (seamless 85 16 200110
protective seal)
Notes: 1) A LIC-HMI-EPAM-STD license product paper is required for operation of EPAM a Licensing.
Display Screen Display area Resolution Additional Type Price Std. pack
diagonal interface Order No.
Inch mm Pixels See price
Device overview XVC600
sheet
XVC600
Processor: Pentium 200 MHz, ETX form factor, 64 MByte DRAM, 32 KByte SRAM
HMI and HMI-PLC
HMI-PLC XVC100
Text display HMI-PLC with small mounting depth for use in restricted spaces.
Windows CE licenses
HMI and HMI-PLC
XVH-3…
WinCE 5.0 Standard license with license sticker XV-2… LIC-OS-CE50-C
XV-4… In preparation
XVS-4…
XVH-3…
Professional license with license sticker XV-2… LIC-OS-CE50-P
XV-4… In preparation
XVS-4…
XVH-3…
Memory cards
– Compact Flash without operating system XV-2… MEMORY-CF-A1-S 1 off
XV-4… 50 61 000400
XVS-4…
XVH-3…
XVC-1…
– Compact Flash, bootable with Windows CE, XV-2… OS-FLASH-A1-S
without Windows CE license XV-4… 90 17 000060
XVS-4…
XVH-3…
– Compact Flash, bootable without operating system and XVC-6… MEMORY-CF-BRS-1
without runtime systems, 50 61 000510
for storing applications and data
XV license product papers
– PLC license product paper with license sticker XV-2xx-57BAS… LIC-PLC-MXP-LIGHT 1 off
XV-2xx-57CNN… 91 30 000050
– PLC license product paper with license sticker XV-2xx-57MPN… LIC-PLC-MXP-SMALL
XV-4xx-57… 91 30 000100
XVS-4xx-57…
– PLC license product paper with license sticker XV-4xx-10… LIC-PLC-MXP-MEDIUM
XV-4xx-12… 91 30 000110
XVS-4xx-10…
XVS-4xx-12…
– EPAM license product paper with license sticker XV-4… LIC-HMI-EPAM-STD
XVS-4… 91 30 000012
XVH-3…
– License product paper 40 POINTS XV-2… LIC-OPT-1ST-LEVEL
XV-4… 91 30 000400
XVS-4…
XVH-3…
– License product paper 80 POINTS XV-2… LIC-OPT-2ND-LEVEL
XV-4… 91 30 000420
XVS-4…
XVH-3…
Communication modules
– Multiprotocol board XV-4… COM-MPB1-TP 1 off
85 12 000009
– Multiprotocol board MPI XV-4… COM-MPB2-TP
85 12 000004
– PROFIBUS DP Master (12Mbaud) XV-4… COM-DPM-MC2
85 12 000200
– PROFIBUS DP Slave (12Mbaud) XV-4… COM-PDP-TP
85 12 000008
– EIB XV-4… COM-EIB2-TP
85 12 000011
Additional fixing brackets
– Additional fixing brackets for IP65 XV-4… ACCESSORIES-HKS-IP65 1 off
XVS-4… 65 01 000002
Set of retaining brackets for mounting the device XVH-3…
(4 retaining brackets with threaded pin)
Batteries
– Spare batteries XVC-6… ACCESSORIES-BAT01x 1 off
XVC-1… 45 60 000001
Accessories
8 Threaded pins for mounting the device
1 Sealing strip for mounting the device
1 Power supply connector
1 Touch pen
– Device accessories as replacement1) XV-4xx-57… ACCESSORIES-TP-57-RES-11)
1 Set of retaining brackets for mounting the device XVS-4xx-57… 83 17 000001
(4 retaining brackets with threaded pin) XVH-3…
1 Sealing strip for mounting the device
1 Power supply connector
1 Touch pen
– Device accessories as replacement XV-4xx-10… ACCESSORIES-TP-10/12-RES-1
2 Set of retaining brackets for mounting the device XV-4xx-12… 83 17 000007
(4 retaining brackets with threaded pin) XVS-4xx-10…
1 Sealing strip for mounting the device XVS-4xx-12…
1 Power supply connector
1 Touch pen
device and thus increase the number of internal license points on the device. the total. The resulting difference is the number of license points that must be added
using the license product papers.
Note:
If there are not enough license points on the device for the required functionality, a
message box of the touch display will prompt you at regular intervals to extend the
license for the device.
Notes: 1) A LIC-HMI-EPAM-STD license product paper is required for the operation of EPAM runtime on XV400, XVS400 and XVH300 devices. The sticker
provided on the license product paper must be affixed to the device. Validation of the certificate via the Internet is unnecessary.
Contact your Micro Innovation representative for any enquiries about other
protocols.
Licensing
EIB (3rd release) COM-EIB2-TP
Matsushita FP Series COM-MPB1-TP / COM-MPB2-TP
Mitsubishi A Series / F Series COM-MPB1-TP / COM-MPB2-TP
Moeller Suconet K COM-MPB1-TP / COM-MPB2-TP
Omron C H K Series COM-MPB1-TP / COM-MPB2-TP
Profibus DP Master (12 Mbaud) COM-DPM-MC2
Profibus DP Slave (12 Mbaud) COM-PDP-TP
Siemens MPI COM-MPB2-TP
Telemecanique Unitelway new COM-MPB1-TP / COM-MPB2-TP
Contact your Micro Innovation representative for any enquiries about other
protocols.
PLC function
PLC license product paper with license sticker XV-2xx-57BAS… LIC-PLC-MXP-LIGHT
XV-2xx-57CNN…
PLC license product paper with license sticker XV-2xx-57MPN… LIC-PLC-MXP-SMALL
XV-4xx-57…
XVS-4xx-57…
PLC license product paper with license sticker XV-4xx-10… LIC-PLC-MXP-MEDIUM
XV-4xx-12…
XVS-4xx-10…
XVS-4xx-12…
EPAM
EPAM license product paper with license sticker XV-4… LIC-HMI-EPAM-STD
XVS-4…
XVH-3…
Communication
40 license points XV-2… LIC-OPT-1ST-LEVEL
XV-4…
XVS-4…
XVH-3…
80 license points XV-2… LIC-OPT-2ND-LEVEL
XV-4…
XVS-4…
XVH-3…
Licensing examples:
HMI application: XV200, XVS400 HMI-PLC application: XV200 Profibus and XVS400 5.7“
PLC
PLC application 100 Points
Licensing
XV-230-57CNN-1-10 XV-230-57MPN-1-10
Display
Screen diagonal / type 5.7" FSTN-LCD (monochrome display)
Technical data XV200
Resolution QVGA (320 x 240 pixels and 240 x 320 pixels with portrait format)
HMI and HMI-PLC
GALILEO
MXpro
100Base-TX / 10Base-T
RS232, not electrically isolated (9-pin, D-Sub connector, male, UNC)
– CAN, not electrically isolated –
(9-pin, D-Sub connector, male, UNC)
– – Profibus1), not electrically isolated,
max. 1.5 Mbit/s (9-pin D-Sub connector,
female, UNC)
USB 1.1, not electrically isolated
IP65
IP20
UL
II 3D EEx II T70°C IP5x:
Zone 22, category 3D
EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61131-2
EN 50014, EN 60079-0, EN 50281-1-1, EN 13463
EN 60950 / UL 60950
EN 50178, EN 61131-2
Approx. 0.7 kg
0…+50°C
-20…60°C
10...95%, non-condensing
according to IEC68-2-27
according to IEC68-2-6
Display
Screen diagonal / type 5.7 "CSTN-LCD (color)
Technical data XV400
Resolution QVGA (320 x 240 pixels and 240 x 320 pixels with portrait format)
HMI and HMI-PLC
Applicable standards and EMC (in relation to CE) EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61131-2
regulations Explosion protection (in relation to CE) EN 50014, EN 60079-0, EN 50281-1-1, EN 13463
Safety EN 60950 / UL 60950
Product standards EN 50178, EN 61131-2
Weight Approx. 1.9 kg
Ambient conditions
Temperature Operation 0…+50°C
Storage / Transport -20…60°C
Relative air humidity 10...95%, non-condensing
Shock according to IEC68-2-27
Vibration according to IEC68-2-6
Infra-red touch, 79 x 59 logic channels Resistive touch, 4-wire Infra-red touch, 95 x 71 logic channels Resistive touch, 4-wire
GALILEO / EPAM
MXpro
100Base-TX / 10Base-T
RS232, not electrically isolated (9-pin, D-Sub connector, male, UNC)
CAN, electrically isolated (9-pin, D-Sub connector, male, UNC)
–
2x USB 2.0 (1.5 / 12 Mbit/s), not electrically isolated
USB 1.1, not electrically isolated
2
0…+50°C
-20…60°C
10...95%, non-condensing
according to IEC68-2-27
according to IEC68-2-6
XVS-440-57MPI-1-10 XVS-430-57MPI-1-10
Display
Screen diagonal / type 5.7 "CSTN-LCD (color)
Technical data XVS400
Resolution QVGA (320 x 240 pixels and 240 x 320 pixels with portrait format)
HMI and HMI-PLC
Infra-red touch, 79 x 59 logic channels Resistive touch, 4-wire Infra-red touch, 95 x 71 logic channels Resistive touch, 4-wire
GALILEO / EPAM
MXpro
100Base-TX / 10Base-T
RS232, not electrically isolated (9-pin, D-Sub connector, male, UNC)
–
Profibus1), not electrically isolated, max. 1.5 Mbit/s (9-pin D-Sub connector, female, UNC)
IP652)
IP20
UL
II 3D EEx II T70°C IP5x:
Zone 22, category 3D2)
EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61131-2
EN 50014, EN 60079-0, EN 50281-1-1, EN 13463
EN 60950 / UL 60950
EN 50178, EN 61131-2
Approx. 3.7 kg Approx. 4.1 kg
0…+50°C
-20…60°C
10...95%, non-condensing
according to IEC68-2-27
according to IEC68-2-6
Display
Screen diagonal / type 5.7 "CSTN-LCD (color)
Technical data XVH300
Resolution QVGA (320 x 240 pixels and 240 x 320 pixels with portrait format)
HMI and HMI-PLC
XVC-601-GTI-10-V1-000 XVC-601-GTI-10-DPM-V1-000
Display
Technical data XVC600
XVC-601-GTI-15-V1-000 XVC-601-GTI-15-DPM-V1-000
EPAM
MXpro
100Base-TX / 10Base-T
RS232, not electrically isolated (9-pin, D-Sub connector, male, UNC)
CAN, electrically isolated (9-pin, D-Sub connector, male, UNC)
– Profibus DP Master, not electrically isolated,
max. 12 Mbit/s
(9-pin D-Sub connector, female, UNC)
PS2
24 VDC
RMS value: 20.4 …28.8 DC
Ripple: F 5 %
10 ms
Max. 38 W
Yes
4 A, slow blow fuse
38 W
No (0V connected to housing potential)
IP65
IP20
EN 61000-6-2, EN 61000-6-4, EN 61131-2
EN 50014, EN 60079-0, EN 50281-1-1, EN 13463
EN 60950
EN 50178, EN 61131-2
Approx. 7 kg
XVC-101-C192K-K82
General
Technical data XVC100
Ambient temperature
Operation 0…60°C
HMI and HMI-PLC
XVC-101-C192K-K82
XVC-101-C192K-K82
Incremental encoder
Technical data XVC100
Number 1
Signals A, B, zero mark, zero mark active
HMI and HMI-PLC
Dimensions
f
a c d
e
Type a b c d e f
Description
Maximum system configuration 2/4
Accessories 2/12
Engineering 2/27
Dimensions 2/38
5
Remote I/O XI/ON
1 2
4
4
8 7
8
6
13 12 11 5
10 9
14
a Page 2/9
Base modules 5
2/3-wire
4-wire
4 x 2/3-wire
a Page 2/10
XN-S4x-SBBS-CJ
XN-B6x-SBBSBB
XN-B6x-SBCSBC
XN-S6x-SBBSBB
XN-S6x-SBCSBC
XN-P4x-SBBC-B
Base modules
XN-B4x-SBBC
XN-P4x-SBBC
XN-S4x-SBBC
XN-S4x-SBBS
XN-S4x-SBCS
XN-B3x-SBB
XN-B3x-SBC
XN-P3x-SBB
XN-S3x-SBB
XN-S3x-SBC
Digital input
XN-2DI-24VDC-P K K
XN-2DI-24VDC-N K K
XN-2DI-120/230VAC-P K K
XN-4DI-24VDC-P K K
XN-4DI-24VDC-N K K
XN-16DI-24VDC-P K K
XN-32DI-24VDC-P K
XNE-8DI-24VDC-P1)
XNE-16DI-24VDC-P1)
Digital output
XN-2DO-24VDC-2A-P K K
XN-2DO-24VDC-0,5A-P K K
XN-2DO-24VDC-0,5A-N K K
XN-4DO-24VDC-0,5A-N K K
XN-16DO-24VDC-P K
XN-32DO-24VDC-0.5A-P K
XNE-8DO-24VDC-0.5A-P1)
XNE-16DO-24VDC-0.5A-P1)
Relay modules
XN-2DO-R-NC K K
XN-2DO-R-NO K K
XN-2DO-R-CO K
Analog input
XN-1AI-I(0/4...20MA) K K
XN-2AI-I(0/4...20MA) K K
XN-1AI-U(-10/0...+10VDC) K K
XN-2AI-U(-10/0...+10VDC) K K
XN-2AI-PT/NI-2/3 K K
XN-2AI-THERMO-PI K
XN-4AI-U/I K
Analog output
XN-1AO-I(0/4...20MA) K
XN-2AO-I(0/4...20MA) K
XN-2AO-U(-10/0...+10V) K
Technology module
XN-1CNT-24VDC K
XN-1RS232 K
XN-1RS485/422 K
XN-1SSI K
XNE-1SWIRE1)
In preparation XN-GWBR-PROFINET
Gateway with integrated power supply and connection to Profinet In preparation
In preparation XN-GWBR-ETHERNET-IP
Gateway with integrated power supply and connection to Ethernet In preparation
In preparation XN-GWBR-PBDP-V1
Gateway with integrated power supply and connection to PROFIBUS-DP V1 In preparation
Programmable gateways
Gateway with integrated power supply XN-PLC-CANOPEN 1 off
Connection to CANopen 85 50 274124
Supports up to 74 modules in slice design
Transmission rate selectable up to 1Mbit/s
1 x open style connector
Connection of the power supply via spring-loaded terminals
PS/2 socket (programming interface for connecting to MXpro)
2 decimal rotary switches (operating mode and user)
Bus refreshing module is already integrated
Bus refreshing Module for supply/refreshing the (nominal) 5 V DC sys- XN-P3T-SBB XN-BR-24VDC-D 1 off
module tem voltage, via internal module bus. XN-P3S-SBB 85 50 225187
Supply for XI/ON modules with 24 V DC nominal volt- XN-P4T-SBBC
age. XN-P4S-SBBC
Gateways of type XN-GW-... require a bus refreshing XN-P4T-SBBC-B
module directly next to the gateway. XN-P4S-SBBC-B
In type XN-GWBR-... gateways the bus refreshing func-
tion is already integrated.
Power feeding Field power supply module with 24 V DC nominal volt- XN-P3T-SBB XN-PF-24VDC-D
module age XN-P3S-SBB 85 50 225186
XN-P4T-SBBC
XN-P4S-SBBC
Power feeding Field power supply module with 120/230 V AC nominal XN-P3T-SBB XN-PF-120/230VAC-D
module voltage XN-P3S-SBB 85 50 225188
XN-P4T-SBBC
XN-P4S-SBBC
I/O modules
Digital input 2 digital inputs, 24 V DC XN-S3T-SBB XN-2DI-24VDC-P 1 off
Positive switching XN-S3S-SBB 85 50 225169
2 digital inputs, 24 V DC XN-S4T-SBBC XN-2DI-24VDC-N
Negative switching XN-S4S-SBBC 85 50 225170
2 digital inputs, 120/230 V AC XN-2DI-120/230VAC
85 50 225171
4 digital inputs, 24 V DC XN-S4T-SBBS XN-4DI-24VDC-P
Positive switching XN-S4S-SBBS 85 50 225165
XN-S6T-SBBSBB
XN-S6S-SBBSBB
4 digital inputs, 24 V DC XN-S4T-SBBS XN-4DI-24VDC-N
Negative switching XN-S4S-SBBS 85 50 225172
XN-S6T-SBBSBB
XN-S6S-SBBSBB
16 digital inputs, 24 V DC XN-B3T-SBB XN-16DI-24VDC-P
Positive switching XN-B3S-SBB 85 50 229434
Block module XN-B4T-SBBC
XN-B4S-SBBC
32 digital inputs, 24 V DC XN-B6T-SBBSBB XN-32DI-24VDC-P
Positive switching XN-B6S-SBBSBB 85 50 230879
Block module
8 digital inputs, 24 V DC – XNE-8DI-24VDC-P
Positive switching 85 50 100794
16 digital inputs, 24 V DC – XNE-16DI-24VDC-P
Positive switching 85 50 101439
Digital output 2 digital outputs, 24 V DC/2 A XN-S3T-SBC XN-2DO-24VDC-2A-P
Positive switching XN-S3S-SBC 85 50 225168
2 digital outputs, 24 V DC/0.5 A XN-S4T-SBCS XN-2DO-24VDC-0.5A-P
Positive switching XN-S4S-SBCS 85 50 225166
2 digital outputs, 24 V DC/0.5 A XN-2DO-24VDC-0.5A-N
Negative switching 85 50 225174
2 digital outputs, 120/230 V AC/0.5 A XN-2DO-120/230VAC-0.5A
85 50 265697
4 digital outputs, 24 V DC/0.5 A XN-S4T-SBCS 85 50
XN-4DO-24VDC-0.5A-P
Positive switching XN-S4S-SBCS 85 50 230880
XN-S6T-SBCSBC
XN-S6S-SBCSBC
16 digital outputs, 24 V DC/0.5 A XN-B3T-SBC XN-16DO-24VDC-0.5A-P
Positive switching XN-B3S-SBC 85 50 229433
Block module
32 digital outputs, 24 V DC/0.5 A XN-B6T-SBCSBC XN-32DO-24VDC-0.5A-P
Positive switching XN-B6S-SBCSBC 85 50 289790
Block module
8 digital outputs, 24 V DC/0.5 A – XNE-8DO-24VDC-0.5A-P
Positive switching 85 50 100795
16 digital outputs, 24 V DC/0.5 A – XNE-16DO-24VDC-0.5A-P
Positive switching 85 50 101438
I/O modules
Spring-loaded terminal
Remote I/O XI/ON
2/3-wire
Base modules With XN-BR-24VDC-D/ base module for the gateway supply XN-BR-24VDC-D XN-P3T-SBB 1 off
With XN-PF-24VDC-D and XN-PF-120/230VAC-D/ base module XN-PF-24VDC-D 85 50 225190
to provide the field supply XN-PF-120/230VAC-D
Slice module XN-2DI-24VDC-P XN-S3T-SBB
XN-2DI-24VDC-N 85 50 225193
XN-2DI-120/230VAC
XN-1AI-I(0/4...20MA)
XN-2AI-I(0/4...20MA)
XN-1AI-U(-10/0...+10VDC)
XN-2AI-U(-10/0...+10VDC)
XN-2AI-PT/NI-2/3
XN-1AO-I(0/4...20MA)
XN-2AO-I(0/4...20MA)
XN-2AO-U(-10/0...+10VDC)
Connection to C rail XN-2DO-24VDC-0.5A-P XN-S3T-SBC
XN-2DO-24VDC-0.5A-N 85 50 225195
XN-2DO-24VDC-2A-P
XN-2DO-120/230VAC-0.5A
Block module XN-16DI-24VDC-P XN-B3T-SBB
85 50 227751
Block module XN-16DO-24VDC-0.5-P XN-B3T-SBC
Connection to C rail 85 50 227752
4-wire
Base modules With XN-BR-24VDC-D/ base module for the gateway supply XN-BR-24VDC-D XN-P4T-SBBC 1 off
With XN-PF-24VDC-D and XN-PF-120/230VAC-D/ base module XN-PF-24VDC-D 85 50 225192
to provide the field supply XN-PF-120/230VAC-D
Connection to C rail
Base modules for bus refreshing within the stations XN-BR-24VDC-D XN-P4T-SBBC-B
Connection to C rail 85 50 225191
Connection to C rail XN-2DI-24VDC-P XN-S4T-SBBC
XN-2DI-24VDC-N 85 50 225194
XN-2DI-120/230VAC
Connection to C rail XN-2DO-24VDC-0,5A-P XN-S4T-SBCS
XN-2DO-24VDC-0,5A-N 85 50 225196
XN-2DO-24VDC-2A-P
XN-2DO-R-NO
XN-2DO-R-NC
XN-2DO-120/230VAC-0.5A
Slice module XN-4DI-24VDC-P XN-S4T-SBBS
XN-4DI-24VDC-N 85 50 225197
XN-1AI-I(0/4...20MA)
XN-2AI-I(0/4...20MA)
XN-1AI-U(-10/0...+10VDC)
XN-2AI-U(-10/0...+10VDC)
XN-2DO-R-CO
XN-2DO-R-NO
XN-2DO-R-NC
XN-2AI-PT/NI-2/3
XN-1CNT-24VDC
Cold junction compensation XN-2AI-THERMO-PI XN-S4T-SBBS-CJ
85 50 225200
Block module XN-16DI-24VDC-P XN-B4T-SBBC
Connection to C rail XN-4AI-U/I 85 50 227753
4 (32) x 2/3-wire
Base modules Slice module XN-4DI-24VDC-P XN-S6T-SBBSBB 1 off
XN-4DI-24VDC-N 85 50 225198
Connection to C rail XN-4DO-24VDC-0.5A-P XN-S6T-SBCSBC
85 50 225199
Block module XN-32DI-24VDC-P XN-B6T-SBBSBB
85 50 227754
Block module XN-32DO-24VDC-0.5A-P XN-B6T-SBCSBC
85 50 289164
Screw terminal
Relay jumpers
The relay jumper are for bridging relay 1-pin XN-QV/1 10 off
roots. 85 50 225216
2-pin XN-QV/2
85 50 225217
3-pin XN-QV/3
85 50 225218
4-pin XN-QV/4
85 50 225219
5-pin XN-QV/5
85 50 225220
6-pin XNQV/6
85 50 225221
7-pin XN-QV/7
85 50 225222
8-pin XN-QV/8
85 50 225223
End plate
For covering a XI/ON station XN-ABPL 2 off
An end plate is supplied as part of the gateway package. 85 50 225250
End bracket
Networking
Fieldbus PROFIBUS-DP CANopen DeviceNet Modbus TCP CANopen
Networking
Fieldbus PROFIBUS-DP CANopen DeviceNet
Operating voltage V DC 5 (from bus refreshing module)
Permissible range V DC 4.7…5.3 4.7…5.3 4.7…5.3 4.7…5.3 4.7…5.3
Ripple % < 5 (to EN 61131-2)
Nominal current drawn from IMB mA F 430 F 430 F 410 F 350 F 250
module bus
Service interface PS/2 socket PS/2 socket PS/2 socket only for PS/2 socket PS/2 socket
firmware download
Connections, fieldbus 2 x SUB-D 1 x SUB-D 1 x SUB-D 1 x SUB-D Open style
connectors, 9-pin connector, 9-pin connector, 9-pin connector, 9-pin connector
2 x spring-loaded 1 x SUB-D
terminal strips for connector, 9-pin
direct wiring 2 x direct wiring,
5-pin;
spring-loaded
Data transmission rate Kbit/s 9.6…1500 9.6…12000 9.6…12000 20, 50, 125, 250, 125, 250, 500
500, 800, 1000
Selecting the data transmis- – – – Via DIP switch Via DIP switch
sion rate
Addressing 2 hex rotary coding plugs 2 rotary coding switches 2 decimal coding
switches
Fieldbus termination Via SUB-D Via SUB-D Via SUB-D Via SUB-D Via DIP switch
connector connector connector connector
Number of parameter bytes 5 bytes 5 bytes 5 bytes – –
Number of diagnostics bytes 3 bytes 3 bytes 3 bytes – –
Address range 1…125 dec. 1…125 dec. 1…125 dec. 1…127 dec. 0…63 dec.
4 4 16 32 8 16
24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC
24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC
-30 V…+5 V 0 V…+5 V -30 V…+5 V -30 V…+5 V -UL…+5 V -UL…+5 V
15 V…30 V > (UPF -11 V) 15 V…30 V 15 V…30 V 11 V…UL 11 V…UL
– – – – – –
< 200 < 200 < 200 < 200 < 100 < 150
< 200 < 200 < 200 < 200 < 200 < 300
– – – – – –
Notes 1) The supply terminal (UL) supplies the current for the module electronics and the loads at the outputs. The total current required for each
module is the sum of all partial currents.
2) Part of the electronics of the XI/ON module is supplied by the module bus voltage (5 V DC), and the other part by the supply terminal (UL).
2 4 16 32 8 16
F 35 F 30 F 45 F 50 15 mA3) 25 mA3)
– – – – – –
Normally 1 Normally 1 Normally 4 Normally 5 Normally 1.5 Normally 2.5
> UL (-2 V) min. L+ (-1 V) min. L+ (-1 V) min. L+ (-1 V) UL…1 V DC UL…1 V DC
< T/2 +1 ms < 250 < 100 < 300 < 300 < 300
< T/2 +1 ms < 250 < 100 < 300 < 300 < 300
at 120 VAC: 48 O…1 kO – 48 O…1 kO – –
240 O…6 kO
at 230 VAC:
460 O…11.5 kO
100 100 100 See Total module current 100 50%, max. 4 A2)
Resistive loads Resistive loads Resistive loads Resistive loads Resistive loads Resistive loads
Inductive loads Inductive loads Inductive loads Inductive loads Inductive loads Inductive loads
Lamp loads Lamp loads Lamp loads Lamp loads Lamp loads Lamp loads
f 48 f 48 f 48 f 48 f 48 f 48
F 1.2 F 1.2 Category DC 13 to F 1.2 To DC13 in accordance To DC13 in accordance
EN 60947-5-1 with IEC 60947-5-1 with IEC 60947-5-1
– F6 F3 F6 F6 F6
– 5000 (RLO < 1 kO) 100 (RLO < 1 kO) 100 (RLO < 1 kO) < 100 < 100
– 2 – – To DC13 in accordance To DC13 in accordance
with IEC 60947-5-1 with IEC 60947-5-1
– F 10 – – < 10 < 10
0 1 4 8 – –
– – – Yes – –
– – – Yes Yes Yes
– – – Automatic Automatic Automatic
Notes: 1) Two outputs can be switched in parallel to increase the maximum output current up to 1 A.
2) The supply terminal (UL) supplies the current for the module electronics and the loads at the outputs. The total current required for each
module is the sum of all partial currents.
3) Part of the electronics of the XI/ON module is supplied by the module bus voltage (5 V DC), and the other part by the supply terminal (UL).
XN-1AI-I(0/4...20MA) XN-2AI-I(0/4...20MA)
Transmitter supply Linked to L+ and L- of the sup- F 250 mA; Linked to L+ and L-
ply; Not short-circuit proof of the supply; Not short-circuit
proof
Cycle time ms – –
Connectable sensors – –
1 2 4 2 2
24 V DC 24 V DC 24 V DC 24 V DC 24 V DC
Relay modules
Contact type 2 break contacts 2 make contacts 2 changeover contacts,
isolated
XN-1CNT-24VDC
Counter module
Channels Number 1
Nominal voltage on supply terminal UL 24 V DC
Remote I/O XI/ON
Notes The nominal current values from the supply terminal apply for
load current = 0 mA.
Interfaces
Type RS 232 RS 484xRS 422 SSI
Nominal voltage on supply UL 24 V DC 24 V DC 24 V DC
Notes The figures for nominal current from the supply terminal apply when there is no sensor/transmitter current.
XNE-1SWIRE
Supply
Module bus voltage 4.75…5.25 V
Current module bus 60 mA
Remote I/O XI/ON
24 V H 24 V H
module bus supply module bus supply
11 21 11 21
24 V H – 24 V H –
12 22 12 22
fieldbus fieldbus
supply + supply +
13 23 13 23
PE 14 24
11 21 11 21
12 22 12 22
24 V H 24 V H
13 23 13 23
14 24
11 21 11 21
12 22 12 22
13 23 13 23
14 24
11 21 11 21
12 22 12 22
13 23 13 23
14 24
11 21 11 21
12 22 12 22
13 23 13 23
14 24
11 21 11 21
12 22 12 22
13 23 13 23
14 24
12 22 12 22
13 23 13 23
S 14 24 S 14 24
15 25
16 26
11 21 11 21
12 22 12 22
13 23 13 23
S 14 24 S 14 24
15 25
16 26
14 24 154 264
S
S 1
2 S
11 21 151 161 3
S
4 S
S 5
12 22 152 162
6 S
S 7
13 23 153 163 8
10
14 24 154 164
16 26 156 166
XNE-16DI-24VDC-P
S
S 1
2 S
S 3
4 S
S 5
6 S
S 7
8 S
S 9
10 S
S 11
12 S
S 13
14 S
S 15
16
24 VDC
12 22 12 22
13 23 13 23
14 24
11 21 11 21
+ + + +
12 22 12 22
13 23 13 23
14 24
11 21 11 21
N N N N
12 22 12 22
13 23 13 23
L L
14 24
11 21 11 21 151 161
12 22 12 22 152 162
13 23 13 23 153 163
14 24
S
S 1
Remote I/O XI/ON
2 S
11 21 3
S
4 S
S 5
12 22
6 S
S 7
13 23 8
10
14 24
15 25 GND
24 VDC
16 26
S
S 1
2 S
11 21
S 3
4 S
12 22 S 5
6 S
S 7
13 23 8 S
S 9
10 S
14 24
S 11
12 S
15 25 S 13
14 S
S 15
16 26
16
GND
12 22 12 22
13 23 13 23
14 24
11 21 11 21
12 22 12 22
13 23 13 23
14 24
Ch1+ Ch2+
11 21
Ch1- Ch2-
12 22
13 23
Ch3+ Ch4+
14 24
Ch3- Ch4-
15 25
16 26
11 21 11 21
12 22 12 22
13 23 13 23
14 24
i
+
11 21
PT100
12 22
a
13 23
PT100
14 24
+
XN-S4x-SBBS with externally applied supply and common potential link Module circuit XN-S4x-SBBS for XN-2DO-R-NC
for XN-2DO-R-NC
12 22
c
a a
13 23 CO0 CO1
14 24 b
a Linked in the electronics
b b Cross-link via QVR in the base module
c Electronic module
XN-S4x-SBCS supply via C-rail and common potential link Module circuit XN-S4x-SBCS for XN-2DO-R-NC
for XN-2DO-R-NC
B B
R1 R2
11 21 11 21 11 21
c
12 22 12 22 12 22 CO CO
13 23 13
a 13 23 b
23
a
14 24 14 24 14 24
24 V H
24 V H b
XN-S4x-SBBS with externally applied supply and common potential link Module circuit XN-S4x-SBBS for XN-2DO-R-NO
for XN-2DO-R-NO
11 21 R2 R1
23 13 M0 11 21 M1
12 22
a a c
22 12 CO 0 14 24 CO 1
13 23
14 24
b
b
a Linked in the electronics
b Cross-link via QVR in the base module
c Electronic module
XN-S4x-SBCS supply via C-rail and common potential link Module circuit XN-S4x-SBCS for XN-2DO-R-NO
for XN-2DO-R-NO
M M
R1 R2
11 21 11 21 11 21
c
CO CO
12 22 12 22 12 22
13 23 13
a 13 23 b
23
a
14 24 14 24 14 24
24 V H
24 V H b
Module circuit XN-S4x-SBBS for XN-2DO-R-CO Module circuit XN-S4x-SBBS for XN-2DO-R-CO
11 21
B M M B
12 22
a
13 23
CO CO
14 24
a Electronic module
10B
10A
0.1 1 10
/ [A]
XN-S4x-SBBS for XN-1RS232 and Submin-D connector XN-S4x-SBBS for XN-1RS485/422 in RS422 mode
RxD
SHLD
SHLD
XN-S4x-SBBS for XN-1SSI on an SSI rotary encoder XN-S4x-SBBS for XN-1RS485/422 in RS485 mode
SSI device
CL+ CL- TxD+/RxD+/P TxD-/RxD-/N
11 21 Clock 11 21
Parallel-serial-converter
12 22 12 22 TxEnable
UL UL UL SHLD SHLD
Data out
13 23 13 23
D+ D- Data out
14 24 14 24 SHLD
Technology module/counters
1
24 VDC +
2
Counter input A Counter input B supply =
or or UAUX − 3
4
pulse input direction input
5
6
11 21
SWIRE
12 22
13 23
14 24
XN-GW-PDBP-1.5MB
XN-GW-PDBP-12MB
Remote I/O XI/ON
XN-GW-PDBP-12MB-STD
XN-GW-CANOPEN
XN-GW-DNET
XN-PLC-CANOPEN
113.25
XN-S3T-SBB XN-P3T-SBB
XN-S3T-SBC XN-P4T-SBBC
XN-S4T-SBBC XN-P4T-SBBC-B
XN-S4T-SBBS XN-S4T-SBBS-CJ
17.6 50 50 50
129
155
41.6
41.6
12.6 41.6
23.5
Screw terminal
XN-S3S-SBB XN-P3S-SBB
XN-S3S-SBC XN-P4S-SBBC
XN-S4S-SBBC XN-P4S-SBBC-B
XN-S4S-SBBS XN-S4S-SBBS-CJ
XN-S4S-SBCS
XN-S6S-SBBSBB XN-x3...
XN-S6S-SBCSBC XN-x4... XN-x6...
17.6 50 50 50
129
155
48.2
48.2
12.6 48.2
23.5
XN-B3S-SBC
101 101
17.6 17.6
117.6
129
23.5
23.5
Spring-loaded 2/3-wire
XN-B6T-SBCSBC
101
17.6
155
23.5
55.4 101
46.1
72.1
72.1
74.1
74.1
47.3
73.1
48.3
67.8
74.5
74.5
129.5 13 161.5 13
48.4 47 8
41.3 4.5
56
114.4
9.2
Selection guide
CANopen 3/3
PROFIBUS-DP 3/19
Modules
CANopen 3/4
PROFIBUS-DP 3/20
PROFIBUS-DP eco 3/36
Accessories 3/44
Technical data
CANopen 3/7
PROFIBUS-DP 3/39
PROFIBUS-DP eco 3/39
Engineering
CANopen 3/10
PROFIBUS-DP 3/24
PROFIBUS-DP eco 3/37
Dimensions 3/45
4
Remote I/O WINbloc
3
CANopen
6
1
a Page 3/4
CAN-4AI/UI
CAN-32DI/P
CAN-16DI/P
CAN-4AO/UI
Digital input
Analog input
Digital output
CAN-4AI/PT100
CAN-8DO/R-NO
Analog output
CAN-16DI/P-2x8
CAN-3AI/1AO-UI
CAN-16DO/R-NO
Combi modules
CAN-4AI/THERMO
CAN-8DO/0.5A-PK
CAN-4DO/2.0A-PK
CAN-16DO/0.5A-PK
CAN-4DI/4DO/0.5A-PK
Digital relay modules
CAN-24DI/8DO/0.5A-PK
CAN-32DO/0.5A-P-2x16
CAN-16DO/0.5A-PK-2x8
Document M001685-01, 2006/2007
K
ZSB-1.5/8-S/+
K
ZSB-1.5/16-S/+
K
ZSB-1.5/8-S/S/+/+
K
ZSB-1.5/16-S/S/++
K
K
ZSB-1.5/8-S/-
2-wire connection
K
ZSB-1.5/16-S/-
K
ZSB-1.5/16-S/S/-/-
K
ZSB-1.5/8-S/S
K
ZSB-1.5/16-S/S
K
ZSB-1.5/16-S/S/+/-+
K
K
K
ZSB-1.5/16-S/S/PE
K
ZSB-1.5/8-S/+/-
K
ZSB-1.5/16-S/+/-
K
ZSB-1.5/8-S/S/+/+/-/-
K
ZSB-1.5/16-S/S/+/+/-/-
3-wire connection
K
K
ZSB-1.5/8-S/-/PE
K
ZSB-1.5/16-S/-/PE
K
ZSB-1.5/8-S/S/PE/PE/-/-
K
ZSB-1.5/16-S/S/P/P/-/-
K
ZSB-1.5/16-S/S/+/-+/-
K
ZSB-1.5/16-S/S/PE-TF
K
ZSB-1.5/8-S/+/-/PE
K
ZSB-1.5/16-S/+/-/PE
ZSB-1.5/8-S/S/-/PE
K
ZSB-1.5/16-S/S/-/PE
4-wire connection
K
ZSB-1.5/8-S/+/-/PE/EI
K
K
ZSB-1.5/16-S/S/PE-+UI
WINbloc CANopen
Selection guide
ZSB-1.5/16-S/S/PE-PT100
3/3
Inputs Outputs Description For use with Type Price Std. pack
Order No.
See price
sheet
Number Number
Remote I/O WINbloc
Bridges
A maximum of 10 I/O modules can be connected per bridge
– – CAN connection to ISO 11 898: – CAN-BRIDGE 1 off
CANopen
Electronic modules
Plugged onto the base modules
Connection types For use with Type Price Std. pack Notes
Order No.
See price
sheet
CANopen
CANopen: CAN-32DO/0.5A-P-2X16 ZSB-1.5/16-S/S/-/- –
85 51 224059
CANopen: CAN-8DI/P ZSB-1.5/8-S/+ Also suitable for Bero ® 2-wire initiator
85 51 224045
CANopen: CAN-24DI/8DO/0.5A-PK ZSB-1.5/16-S/S/+/-+ –
85 51 224063
CANopen: CAN-8DO/R-NO ZSB-1.5/8-S/S –
85 51 224061
CANopen: CAN-16DI/P ZSB-1.5/16-S/+ Also suitable for Bero ® 2-wire initiator
85 51 224048
CANopen: CAN-16DI/P-2x8 ZSB-1.5/8-S/S/+/+ –
85 51 224049
CANopen: CAN-4DO/2.0A-PK ZSB-1.5/8-S/- –
CANopen: CAN-8DO/0.5A-PK 85 51 224055
CANopen: CAN-16DO/R-NO ZSB-1.5/16-S/S –
85 51 224062
CANopen: CAN-16DO/0.5A-PK ZSB-1.5/16-S/- –
85 51 224056
Connection types For use with Type Price Std. pack Notes
Order No.
See price
sheet
Remote I/O WINbloc
Base modules
3-wire connection CANopen: CAN-16DO/0.5A-PK ZSB-1.5/16-S/-/PE 1 off –
85 51 224054
CANopen: CAN-16DI/P ZSB-1.5/16-S/+/- Also suitable for Bero ® 2-wire initiator
CANopen
85 51 224047
WINbloc CANopen
General
Standards IEC/EN 61131
CANopen
Ambient temperature
Operation °C 0…55
Storage °C -20/85
Relative air humidity, non-condensing % 15…95
(IEC/EN 60068-2-30)
Electromagnetic compatibility (EMC)
Immunity As per EN 50082-1 and IEC/EN 61000-6-2
Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD)
Air discharge kV 8
Contact discharge kV 4
Electromagnetic fields (IEC/EN 61000-4-3, RFI) V/m 10
Burst pulses (IEC/EN 61000-4-4, level 3) kV 2
RFI suppression (EN 55011)2) 10 V, requirements as per EN 55011 Group 1, Class A,
Emitted RFI as per EN 50081-2
Degree of protection (IEC/EN 60529) IP20
Vibration resistance (IEC/EN 60068-2-6) Yes
Shock resistance (IEC 60068-2-27) 20 m/s2 (2 g) to IEC 60068-2-27
Repetitive shock resistance (IEC/EN 60068-2-29) Yes
Approvals UL
Base modules
Base modules
Standards VDE 0611 Part 1/8.92
IEC/EN 60947-7-1
Rated voltage V 250
Rated current Ie A 17.5 A q continuous current via distribution strip ZVL
Conductor cross-section mm2 1.5
Rated impulse withstand voltage Uimp kV 4
Pollution degree 3
Connections in TOP direction Spring-loaded
Stripping length mm 8
Terminal capacity mm2 0.13…2.5
Solid mm2 0.5…2.5
Flexible mm2 0.5…1.5
Flexible with ferrule3) mm2 0.5…1.5
Plug gauge IEC/EN 60 947-1 A2
Bridges CAN-BRIDGE
Operating voltage V DC 24
Operating current mA < 60
Data transmission rate/distance 10 Kbit/s…1.0 Mbit/s
Weight 116 g
Status ‘1’
High signal UH 11 V DC…30 V DC 11 V DC…30 V DC 11 V DC…30 V DC 15 V DC…30 V DC
High signal IH 2 mA…4.5 mA 2 mA…4.5 mA 2 mA…3.5 mA 2 mA…3.5 mA
Status ‘0’
CANopen
Low signal UL -30 V DC…5 V DC -30 V DC…5 V DC -30 V DC…5 V DC -30 V DC…5 V DC
Input delay Rising edge, falling edge for “active low” < 200 ms (3-wire initiator)
Falling edge for “open switch” < 2 ms
Weight 167 g g 15% 313 g g 15% 167 g g 15% 313 g g 15%
CAN-8DO/R-NO CAN-16DO/R-NO
Relay modules
Operating voltage V DC 24 24
CANopen
Nominal load voltage 110 V DC/250 V AC 110 V DC/250 V AC
Continuous current Max. current per output: 2 A, AC 1 Max. current per output: 1 A, AC 1
Max. total current per group of 4: 6 A, AC 1 Max. total current per group of 4: 4 A, AC 1
Max. contact current: 60 W/500 VA Max. contact current: 60 W/500 VA
Min. contact current: 100 mA Min. contact current: 100 mA
Lifespan, mechanical Operations 2 x 107 2 x 107
5
Lifespan, electrical Operations 10 , at 250 V AC/2 A/AC 105, at 250 V AC/2 A/AC
Insulation test voltage, contact/coil kV 1 1
Creepage and clearance distances 3 mm between relay pairs 3 mm between relay pairs
Switching frequency 20 min-1 at nominal load 20 min-1 at nominal load
Weight 167 g g 15% 313 g g 15%
CAN-4AO/UI CAN-3AI/1AO-UI
CAN-4DI/4DO/0.5A-PK CAN-24DI/8DO/0.5A-PK
Combi modules
Operating voltage V DC 24 24
Permissible range V DC 18…30 18…30
Input delay Rising edge, falling edge for “active low” < 200 ms (3-wire initiator)
Falling edge for “open switch” < 2 ms
Potential isolation Operating voltage – field voltage: 500 Vrms/min Operating voltage – field voltage: 500 Vrms/min
Inputs/outputs as per standard Inputs: EN 61131-2, Type 1 Inputs: EN 61131-2, Type 1
Outputs: EN 61131
Field current (without load) F 20 mA F 35 mA
Status ‘1’
High signal UH 11 V DC…30 V DC 15 V DC…30 V DC
High signal IH 2 mA…4 mA 2 mA…4 mA
Status ‘0’
Low signal UL -30 V DC…5 V DC -30 V DC…5 V DC
Lamp load RLL W F2 F2
Utilization factor g % 100 100
Output delay Q 1 ms, DO RL F 1 kO Q 3 ms, DO RL F 1 kO
Output current A F0.5 F0.5
Weight 167 g g 15% 313 g g 15%
Filter
+
CAN
UL
CAN-8DI/P
Diagnostics
Logic UL 1 2 3 4 5 6 7 8 U+
Electrical separation
+ 8
F1
μF μF
Ω Ω
+S 1 ......... 8
CAN-16DI/P
Diagnostics
Logic
Electrical separation UL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 U+
+ 16
μF μF
Ω Ω F1
1................. . . . . . . . . . . . . . . . . . . 16
Electrical separation
CANopen
U- 9 10 11 12 13 14 15 16
μF μF + 8
Ω Ω
+ 16
F1
1 ............ 8
9 . . . . . . . . . . . 16
CAN-32DI/P-2X16
Diagnostics
Logic 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Electrical separation
U- 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
μF μF + 16
Ω Ω
+ 32
F1
1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Diagnostics
Electrical separation
U+ 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D
CANopen
A/D converter
Configuration U- 0V U1 0V I1 0V U2 0V I2 0V U3 0V I3 0V U4 0V I4
V/A inputs
Multiplexer
Ω
Ω F1 16
+ + + +
-10...+10V
0...20mA
4...20mA
CAN-PT100
Diagnostics
U+ 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D
Electrical separation
U- 1.1 1.2 1.3 1.4 2.1 2.2 2.3 2.4 3.1 3.2 3.3 3.4 4.1 4.2 4.3 4.4
D/A converter
Configuration
inputs Multiplexer 16
F1
i i i i
4 AI 2-cond.
4 AI 3-cond.
4 AI 4-cond.
Electrical separation
CANopen
U- 1.1 1.2 2.1 2.2 3.1 3.2 4.1 4.2
A/D converter
Configuration
V/A inputs
Multiplexer F1 16
4x
A B C D Cold junction +
4x compensation
+ + + +
ZQV (2-4) UL
CAN-4DO/2.0A-PK
Diagnostics
Logic
Electrical separation U 1 2 3 4 5 6 7 8 U+
F2
R1...R4
Diagnostics
Logic
U 1 2 3 4 5 6 7 8 U+
Electrical separation
CANopen
F2
R1 . . . . . . . . . . . . R8
CAN-16DO/0.5A-PK
Diagnostics
Logic
U 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 U+
Electrical separation
16
F1
R1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R16
CAN-16DO/0.5A-P-2X8
U 1 2 3 4 5 6 7 8 U+
Diagnostics
Logic
9 10 11 12 13 14 15 16
Electrical separation
16
F1 F16
F0
R1 . . . . . . . . . R8
R9 . . . . . . . . R16
Electrical separation
CANopen
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
16
F1 F16
F0
R1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R16
R17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R32
CAN-8DO/R-NO
Diagnostics
Logic U- 13 23 33 43 53 63 73 83
Electrical separation
U+ 14 24 34 44 54 64 74 84
13 23 33 43 53 63 73 83
F1
14 24 34 44 54 64 74 84
Root 13 23 33 43 53 63 73 83
CAN-16DO/R-NO
Diagnostics
Logic 13 23 33 43 53 63 73 83 93 103 113 123 133 143 153 163
Electrical separation
U+ 14 24 34 44 54 64 74 84 94 104 114 124 134 144 154 164
F1
Diagnostics
Electrical separation U+ 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D
CANopen
A/D converter
U- OV U1 OV I1 OV U2 OV I2 OV U3 OV I3 OV U4 OV I4
Configuration
V/A inputs
F1 16
RL RL RL RL
-10...+10V
0...20mA
4...20mA
CAN-4DI/4DO/0.5A-PK
Diagnostics
Logic
UL 1 2 3 4 5 6 7 8 U+
Electrical separation
Ω Ω + 8
μF μF
b a
RL
S+
PE
Electrical separation
CANopen
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Ω Ω
μF μF
+ 32
7
16
/9+
b
a
F1 R1 . . . . . . R7 9 . . . . . . . . . . 16
F2 c 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
CAN-3AI/1AO-UI
Diagnostics
Electrical separation
U+ 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D
Configuration U- 0V U1 0V I1 0V U2 0V I2 0V U3 0V I3 0V U4 0V I4
V/A inputs
Multiplexer
Ω
Ω
F1 16
+ + +
RL
-10...+10V
0...20mA
4...20mA
4
Remote I/O WINbloc
3
PROFIBUS-DP
1 6
a Page 3/20
ZSB-1.5/16-S/S/PE-PT100
ZSB-1.5/16-S/S/+/P+/-/-
ZSB-1.5/8-S/S/PE/PE/-/-
ZSB-1.5/16-S/S/PE-+UI
ZSB-1.5/16-S/S/+/+/-/-
ZSB-1.5/16-S/S/P/P/-/-
ZSB-1.5/16-S/S/+/-+/-
ZSB-1.5/16-S/S/PE-TF
ZSB-1.5/8-S/S/+/+/-/-
ZSB-1.5/16-S/S/+/-+
ZSB-1.5/16-S/+/-/PE
ZSB-1.5/16-S/-250V
ZSB-1.5/16-S/-/PE-Z
ZSB-1.5/16-S/S/-/PE
ZSB-1.5/8-S/S/+/-/-
ZSB-1.5/8-S/+/-/PE
ZSB-1.5/8-S/S/-/PE
ZSB-1.5/8-S/S/+/+
ZSB-1.5/16-S/S/PE
ZSB-1.5/16-S/S/-/-
ZSB-1.5/16-S/-/PE
ZSB-1.5/16-S/+/-
ZSB-1.5/8-S/-/PE
ZSB-1.5/8-S/+/-
ZSB-1.5/16-S/+
ZSB-1.5/16-S/S
ZSB-1.5/16-S/-
ZSB-1.5/8-S/+
ZSB-1.5/8-S/S
ZSB-1.5/8-S/-
PROFIBUS-DP
Digital input
DP-8DI/P K K K
DP-16DI/P K K K
DP-16DI/P-2X8 K K
DP-32DI/P-2X16 K K
DP-8DI/N K
DP-8DI/230VAC K
Digital output
DP-4DO/2.0A-PK K K
DP-8DO/0.5A-PK K K
DP-16DO/0.5A-PK K K
DP-16DO/0.5A-PK-2x8 K
DP-32DO/0.5A-P-2x16 K K
Analog input
DP-4AI/UI K K
DP-4AI/PT100 K
DP-4AI/THERMO K
Analog output
DP-4AO/UI K K
Technology modules
DP-1CNT/24V K
Combi modules
DP-8DI/8DO/0.5A-PK K
DP-24DI/8DO/0.5A-PK K K K
DP-3AI/1AO-UI K K
Inputs Outputs Description For use with Type Price Std. pack
Order No.
See price
sheet
Number Number
Remote I/O WINbloc
Bridges
A maximum of 10 I/O modules can be connected per bridge
PROFIBUS-DP
Electronic modules
Plugged onto the base modules
Inputs Outputs Description For use with Type Price Std. pack
Order No.
See price
sheet
Number Number
PROFIBUS-DP
output, short-circuit proof 85 51 224027
8 8 Positive switching, digital input/out- ZSB-1.5/8-S/S/+/-/- DP-8DI/8DO/0.5A-PK
put, short-circuit proof 85 51 224025
24 8 Positive switching, digital input/out- ZSB-1.5/16-S/S/+/-+ DP-24DI/8DO/0.5A-PK
put, short-circuit proof ZSB-1.5/16-S/S/+/-+/- 85 51 224023
ZSB-1.5/16-S/S/+/P+/-/-
Counter module – – 1 channel, up/down, 25 kHz ZSB-1.5/16-S/-/PE-Z DP-1CNT/24V
85 51 224028
Analog input 4 – Input range ZSB-1.5/16-S/S/PE DP-4AI/UI
voltage -10/0…+10 V ZSB-1.5/16-S/S/PE-+UI 85 51 224030
4 – PT100, 2, 3, 4-wire ZSB-1.5/16-S/S/PE- DP-4AI/PT100
PT100 85 51 224031
4 – Thermo K, J, R, S, T, N, E, B ZSB-1.5/16-S/S/PE-TF DP-4AI/THERMO
85 51 224032
Analog output – 4 Output range ZSB-1.5/16-S/S/PE DP-4AO/UI
voltage -10/0…+10 V ZSB-1.5/16-S/S/PE-+UI 85 51 224033
Output range,
current 0/4…20 mA
Relay module – 8 8-way relay, make contact ZSB-1.5/8-S/S DP-8DO/R-NO
ZSB-1.5/8-S/S/-/PE 85 51 224016
– 16 16-way relay, make contact ZSB-1.5/16-S/S DP-16DO/R-NO
ZSB-1.5/16-S/S/-/PE 85 51 224019
– 8 8-way relay, changeover contact iso- – DP8DO/R-CO
lated 85 51 224022
Combi modules 3 1 Input / output range, voltage ZSB-1.5/16-S/S/PE DP-3AI/1AO-UI
-10/0…+10 V ZSB-1.5/16-S/S/PE-+UI 85 51 224311
Input / output range, current
0/4…20 mA
Connection types For use with Type Price Std. pack Notes
Order No.
See price
sheet
Remote I/O WINbloc
Base modules
For connection to electronic module; rail-mounted
2-wire connection PROFIBUS: DP-24DI/8DO/0.5A-PK ZSB-1.5/16-S/S/+/-+ 1 off –
PROFIBUS-DP
85 51 224063
PROFIBUS: DP-16DO/R-NO ZSB-1.5/16-S/S –
85 51 224062
PROFIBUS: DP-8DI/P ZSB-1.5/8-S/+ Also suitable for Bero ® 2-wire initiator
85 51 224045
PROFIBUS: DP-8DI/115V AC ZSB-1.5/16-S/-250V –
PROFIBUS: DP-8DI/230V AC 85 51 224096
PROFIBUS: DP-8DO/R-NO ZSB-1.5/8-S/S –
85 51 224061
Connection types For use with Type Price Std. pack Notes
Order No.
See price
sheet
PROFIBUS-DP
PROFIBUS: DP-32DI/P-2X16 ZSB-1.5/16-S/S/+/+/-/- –
85 51 224052
PROFIBUS: DP-32DO/0.5A-P-2X16 ZSB-1.5/16-S/S/P/P/-/- –
224060
PROFIBUS: DP-24DI/8DO/0.5A-PK ZSB-1.5/16-S/S/+/-+/- –
85 51 224064
PROFIBUS: DP-1CNT/24V ZSB-1.5/16-S/-/PE-Z Cross-link (ZQV) for setting individual channels
85 51 224073 in delivery package
PROFIBUS: DP-8DI/8DO/0.5A-PK ZSB-1.5/8-S/S/+/-/- Cross-link (ZQV) for setting individual channels
85 51 224086 in delivery package
PROFIBUS: DP-4AI/THERMO ZSB-1.5/16-S/S/PE-TF Cold junction compensation and linearization
85 51 224075 Accuracy figures take into account linearity,
hysteresis and cold-junction compensation
error at Tu= 23 °C
A cable break is reliably detected.
Cross-link (ZQV) for setting individual channels
in delivery package.
PROFIBUS: DP-24DI/8DO/0.5A-PK ZSB-1.5/16-S/S/+/P+/-/- –
85 51 224065
PROFIBUS: DP-16DO/R-NO ZSB-1.5/16-S/S/-/PE –
85 51 224070
PROFIBUS: DP-8DO/R-NO ZSB-1.5/8-S/S/-/PE –
85 51 224069
PROFIBUS: DP-4AI/UI ZSB-1.5/16-S/S/PE-+UI Cross-link (ZQV) for setting individual channels
PROFIBUS: DP-4AO/UI 85 51 224074 in delivery package
PROFIBUS: DP-3AI/1AO-UI
PROFIBUS: DP-8DI/P ZSB-1.5/8-S/+/-/PE Also suitable for Bero ® 2-wire initiator
85 51 224043
PROFIBUS: DP-16DI/P ZSB-1.5/16-S/+/-/PE Also suitable for Bero ® 2-wire initiator
85 51 224046
PT100 2, 3, 4-wire PROFIBUS: DP-4AI/PT100 ZSB-1.5/16-S/S/PE-PT100 Cross-link (ZQV) for setting individual channels
connection and PT100 85 51 224076 in delivery package
mixed operation
Filter Filter
Fieldbus Fieldbus
UL UL
DP-8DI/P
Diagnostics
Logic UL 1 2 3 4 5 6 7 8 U+
Electrical separation
+ 8
F1
μF μF
Ω Ω
+S 1 ......... 8
DP-16DI/P
Diagnostics
Logic
Electrical separation UL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 U+
+ 16
μF μF
Ω Ω F1
1................. . . . . . . . . . . . . . . . . . . 16
PROFIBUS-DP
Electrical separation
U- 9 10 11 12 13 14 15 16
μF μF
+ 8
Ω Ω
+ 16
F1
1 ............ 8
9 . . . . . . . . . . . 16
DP-32DI/P-2X16
Diagnostics
Logic 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Electrical separation
U- 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
μF μF + 16
Ω Ω
+ 32
F1
1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
DP-8DI/N
Diagnostics
Logic
Electrical separation U 1 2 3 4 5 6 7 8 U+
1 ............ 8
Diagnostics
Logic
PROFIBUS-DP
Electrical separation PE 1 2 3 4 5 6 7 8
N 8
68 nF 68 nF
Ω Ω
h h
1 8
DP-4AI/UI
Diagnostics
Electrical separation
U+ 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D
A/D converter
U- 0V U1 0V I1 0V U2 0V I2 0V U3 0V I3 0V U4 0V I4
Configuration
V/A inputs
Multiplexer
Ω
Ω F1 16
+ + + +
-10...+10V
0...20mA
4...20mA
PROFIBUS-DP
Electrical separation
U- 1.1 1.2 1.3 1.4 2.1 2.2 2.3 2.4 3.1 3.2 3.3 3.4 4.1 4.2 4.3 4.4
A/D converter
Configuration
V/A inputs
Multiplexer 16
F1
Ω
Ω
i i i i
4 AI 2-cond.
4 AI 3-cond.
4 AI 4-cond.
Diagnostics
mP U+ 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D
PROFIBUS-DP
Electrical separation
U- 1.1 1.2 2.1 2.2 3.1 3.2 4.1 4.2
A/D converter
Configuration
V/A inputs
Multiplexer F1 16
4x
A B C D Cold junction +
4x compensation
+ + + +
ZQV (2-4) UL
DP-4DO/2.0A-PK
Diagnostics
Logic
U 1 2 3 4 5 6 7 8 U+
Electrical separation
F2
R1...R4
PROFIBUS-DP
U 1 2 3 4 5 6 7 8 U+
Electrical separation
F2
R1 . . . . . . . . . . . . R8
DP-16DO/0.5A-PK
Diagnostics
Logic
U 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 U+
Electrical separation
16
F1
R1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R16
DP-16DO/0.5A-PK-2X8
U 1 2 3 4 5 6 7 8 U+
Diagnostics
Logic
9 10 11 12 13 14 15 16
Electrical separation
16
F1 F16
F0
R1 . . . . . . . . . R8
R9 . . . . . . . . R16
Diagnostics
Logic U 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 U+
PROFIBUS-DP
Electrical separation
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
16
F1 F16
F0
R1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R16
R17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R32
DP-8DO/R-NO
Diagnostics
Logic U- 13 23 33 43 53 63 73 83
Electrical separation
U+ 14 24 34 44 54 64 74 84
13 23 33 43 53 63 73 83
F1
14 24 34 44 54 64 74 84
Root 13 23 33 43 53 63 73 83
DP-16DO/R-NO
Diagnostics
Logic 13 23 33 43 53 63 73 83 93 103 113 123 133 143 153 163
Electrical separation
U+ 14 24 34 44 54 64 74 84 94 104 114 124 134 144 154 164
F1
PROFIBUS-DP
11 14 12 21 24 22 31 34 32 41 44 42
Electrical separation
51 54 52 61 64 62 71 74 72 81 84 82
12 14 22 24 32 34 42 44
F1
11 21 31 41
52 54 62 64 72 74 82 84
51 61 71 81
DP-4AO/UI
Diagnostics
Electrical separation U+ 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D
A/D converter
U- OV U1 OV I1 OV U2 OV I2 OV U3 OV I3 OV U4 OV I4
Configuration
V/A inputs
F1 16
RL RL RL RL
-10...+10V
0...20mA
4...20mA
Diagnostics
Logic
PROFIBUS-DP
16
PE
8
/+
h i j k b
+
+ RL
+
S+
+
Supply of inputs
h Supply of output channel 1
i Supply of output channel 2
j Supply of output channel 3
k Supply of output channel 4
DP-8DI/8DO/0.5A-PK
Diagnostics
Logic
PE UL1 1 2 3 4 5 6 7 8 UL2
Electrical separation
9 10 11 12 13 14 15 16
Ω Ω
μF μF
+ 8
16
b a
RL
S+
PROFIBUS-DP
Electrical separation
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Ω Ω
μF μF
+ 32
7
16
/9+
b
a
F1 R1 . . . . . . R7 9 . . . . . . . . . . 16
F2 c 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
DP-1CNT/24V
Diagnostics
mP
U A B Z V+ 1 2 3 4 5 6 Q1 Q2 F F+ U+
Electrical separation
mP
16
Configuration
Counter
16
1nF
1 2 3 4 5 6
4x 2x +
250 O 24 H
F1 RL RL S
RL UL
Diagnostics
PROFIBUS-DP
Electrical separation
U+ 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D
Ω
Ω F1 16
+ + +
RL
-10...+10V
0...20mA
4...20mA
Inputs Outputs Description For use with Type Price Std. pack
Order No.
See price
sheet
Number Number
Remote I/O WINbloc
PROFIBUS-DP eco
Electronic modules
Plugged onto the base modules
Base modules
For connection to electronic module; rail-mounted
2-wire connection PROFIBUS eco: DP-16DO/0.5A-PK-ECO ZSBE-1.5/25-S/PE- 1 off
85 51 224079
PROFIBUS eco: DP-16DI/P-ECO ZSBE-1.5/25-S/PE-+
85 51 224080
PROFIBUS eco: DP-32DO/0.5A-PK-ECO ZSBE-1.5/25-S/S/+-/PE-
85 51 224082
PROFIBUS eco: DP-32DI/P-ECO ZSBE-1.5/25-S/S/+-+/PE+
85 51 224083
PROFIBUS-DP eco
PE GND +5V A A' B B' US I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 I12 I13 I14 I15 I16
PE
Filter I1 . . . . . . . . . . . . . . . . . . . . . . . . . I16
+
+
DP-32DI/P-ECO
Diagnostics
Logic
PE GND +5V A A' B B' US I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 I12 I13 I14 I15 I16
I17 I18 I19 I20 I21 I22 I23 I24 I25 I26 I27 I28 I29 I30 I31 I32
+
Filter
+
Q1 . . . . . . . . . . . . . . . . . . . Q16
+
Q17 . . . . . . . . . . . . . . . . . Q32
+
DP-16DO/0.5A-PK-ECO
Diagnostics
Logic
PE GND +5V A A' B B' US UL1 I1 I2 I3 I4 I5 I6 I7 I8 UL2 I9 I10 I11 I12 I13 I14 I15 I16
PE
Q1 . . . . . . . . . . . . . . . . . . . . . Q16
Filter
+
+
Diagnostics
Logic
PROFIBUS-DP eco
PE GND +5V A A' B B' US UL1 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 UL2 Q9 Q10 Q11 Q12 Q13 Q14 Q15 Q16
UL3 Q17 Q18 Q19 Q20 Q21 Q22 Q23 Q24 UL4 Q25 Q26 Q27 Q28 Q29 Q30 Q31 Q32
Filter
Q1 . . . . . . . . . . . . . . . . . . Q16
+
+
Q17 . . . . . . . . . . . . . . . . . Q32
+
DP-16DI-P/16DO/0.5A-PK-ECO
Diagnostics
Logic
PE GND +5V A A' B B' US UL1 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 UL2 Q9 Q10 Q11 Q12 Q13 Q14 Q15 Q16
I17 I18 I19 I20 I21 I22 I23 I24 I25 I26 I27 I28 I29 I30 I31 I32
Filter
+ +
Q1 . . . . . . . . . . . . . . Q16 S-+
+
I17 . . . . . . . . . . . . . . I32
+
General
Standards IEC/EN 61131 IEC/EN 61131-2 Type 1
Base modules
Base modules
Standards VDE 0611 Part 1/8.92
IEC/EN 60947-7-1
Rated voltage V 250
Rated current Ie A 17.5 A q continuous current via distribution
strip ZVL
Conductor cross-section mm2 1.5
Rated impulse withstand voltage Uimp kV 4
Pollution degree 3
Connections in TOP direction Spring-loaded
Stripping length mm 8
Terminal capacity mm2 0.13…2.5
Solid mm2 0.5…2.5
Flexible mm2 0.5…1.5
Flexible with ferrule1) mm2 0.5…1.5
Plug gauge IEC/EN 60 947-1 A2
Operating voltage V DC 24 24
Operating current mA < 80 < 80
Data transmission rate/distance 9.6 Kbit/s…1.5 Mbit/s 9.6 Kbit/s…12 Mbit/s
Weight 116 g 116 g
Type 1
Status ‘1’
High signal UH 11 V DC…30 V DC 15 V DC…30 V DC 0…2 V DC 184 V AC…265 V
AC
High signal IH 2 mA…5.5 mA 2 mA…4.5 mA 1.5 mA…2 mA Normally
5 mA/230 V AC
Status ‘0’
Low signal UL -30 V DC…5 V DC 15 V DC…30 V DC 0…40 V AC
Low signal IL -50 mA…1.5 mA – –
Input delay Rising edge, falling edge for “active low” < 200 ms (3-wire initiator) 200 ms
Falling edge for “open switch” < 2 ms
Input power loss mW/ – – – – – 200
chan-
nel
Input reactive current VA/ – – – – – 1.25
chan-
nel
Weight 167 g g 15% 313 g g 15% 167 g g 15% 313 g g 15% 167 g g 15% 167 g g 15%
Relay modules
Operating voltage V DC 24 24 24
DP-4AO/UI
Combi modules
Operating voltage V DC 24 24 24
Permissible range V DC 18…30 18…30 18…30
Input delay – – –
Potential isolation – – –
Inputs/outputs as per standard
Field current (without load) F 40 mA F 40 mA F 35 mA
Status ‘1’
High signal UH 11 V DC…30 V DC 11 V DC…30 V DC 11 V DC…30 V DC
High signal IH 2 mA…4 mA 2 mA…4.5 mA 2 mA…4 mA
Status ‘0’
Low signal UL -30 V DC…5 V DC -30 V DC…5 V DC -30 V DC…5 V DC
Low signal IL -50 mA…700 mA -50 mA…700 mA -50 mA…700 mA
Output load capacity 2 x Iout for 5 min. – –
Underload at Iload mA < 150/< 750 – –
Lamp load RLL W F 20 F2 F2
Utilization factor g % – 50 100
Output delay < 1 ms Q 1 ms, DO RL F 1 kO Q 1 ms, DO RL F 1 kO
Output current A F2 F0.5 F0.5
Weight 313 g g 15% 167 g g 15% 313 g g 15%
DP-3AI/1AO-UI
DP-1CNT/24V
Counter module
Operating voltage V DC 24
Permissible range V DC 18…30
Input voltage
Input voltage nominal value V DC 24 V DC
Low signal UL -1…+4 V DC (sensor/transmitter: -1…+1.5 V DC)
High signal UH +5…+30 V DC (sensor/transmitter: +4…+30 V DC)
Input current
High signal IH Normally 4 mA (sensor/transmitter: 2.5 mA)
Frequency F 100 Hz
Output current mA F 500, short-circuit proof
Nominal voltage on supply terminal UL 24 V DC
Ripple % g 5, permissible range (incl. ripple) 21.6…26.4 V DC
Nominal current drawn from module bus IMB mA F 60
Weight 313 g g 5%
DP-16DI/P-ECO DP-32DI/P-ECO
DP-16DI-P/16DO/0.5A-PK-ECO
Combi modules
Operating voltage V DC 24
Permissible range V DC 18…30
Input delay 3
Potential isolation from the fieldbus 500 Vrms/min
Inputs/outputs as per standard IEC/EN 61131
Field current (without load) F 20 mA per UL feed
Status ‘1’
High signal UH 15 V DC…30 V DC
High signal IH 1.2 mA…4 mA
Status ‘0’
Low signal UL -5 V DC…5 V DC
Lamp load RLL W F3
Output delay < 100 ms (for R F 1 kO)
Output current A F0.5
Weight 550 g g 15%
Accessories
ERbic PROFIBUS connector without termination resistor (gray) PROFIBUS ERBIC-PB-CONNECTOR/WITHOUT-TERMINAT. 1 off
85 51 231005
with termination resistor (yellow) ERBIC-PB-CONNECTOR/WITH-TERMINATION
85 51 231006
6+
36 45 36 48
CAN-BRIDGE
116
36 45
94
102
115
128
141
S S
S S
+ +
+ +
56 70
94
102
115
128
141
S S
S S
+ +
+ +
97 70
142 90
Page
Visualization software
GALILEO 4/2
GALILEO OPEN 4/2
EPAM 4/2
Software
MXpro 4/2
Additional software
S7-PG-Router 4/2
CE Telediag 4/2
CAN Monitor 4/2
DXS Server 4/2
Visualization software
GALILEO GALILEO, the MS-Windows™-based intelligent and interactive visual- SW-GALILEO 1 off
ization tool enables you to create projects for operating and visualizing 91 25 000021
machinery, plants and buildings in the simplest possible way.
Comprehensive help and documentation.
Software
GALILEO OPEN The LIC-GALILEO-OPEN-PC license product paper enables continuous LIC-GALILEO-OPEN-PC
and unrestricted operation of the GALILEO runtime system on a stan- 91 30 000020
dard PC. The runtime system software is part of the GALILEO develop-
ment software.
EPAM The Easy Page Machine (EPAM) visualization tool is designed as an SW-EPAM
open visualization system that must be integrated in MS-Excel as an
Add-in tool.
PLC programming software
MXpro Programming to IEC 61131-1 with IL, ST, LD, FBD, SFC, CFC. SW-MXPRO 1 off
Bus configuration CAN, PROFIBUS-DP, XI/ON. 91 24 000007
Comprehensive help and documentation.
Additional software
S7-PG-Router This tools enables the programming of S7 programmable controllers SW-S7-PG-ROUTER 1 off
connected to the Micro Innovation Panel via Ethernet interface of the 91 26 000001
panel. XV200 and XVS400 devices with onboard Profibus and Ethernet
interface support the S7 PG Routing function. This function requires 80
license points on the device → HMI / HMI-PLC licensing.
This product consists of the software with documentation and a license
product paper with 80 points for licensing a device.
CE Telediag This tool enables user-friendly teleservice via a modem connection with SW-CE-TELEDIAG
a dialup assistant and device callback. XV200, XVS400, XV400 and 91 26 000015
XVH300 devices with onboard System Port (RS232) interface support
the CE Telediag function. This function requires 40 license points on the
device → HMI / HMI-PLC licensing.
This product consists of the software with documentation and a license
product paper with 40 points for licensing a device.
CAN Monitor The CAN monitor tool enables the monitoring and tracing of CAN tele- SW-CAN-MONITOR
grams with a related time stamp, COB-ID and data. Error frames are not 91 26 000005
detected. XV200, XV400 and XVH300 devices with onboard CAN inter-
face support the CAN monitor function. This function does not require
any license points on the device.
This product consists of the software and documentation.
DXS Server DXS (Data Exchange Service) is a service for distributing data between SW-DXS-SERVER
all connected clients. A robust event-driven and transaction-oriented 91 26 000010
communication protocol for Micro Innovation devices with GALILEO
runtime is used. XV200, XVS400, XV400 and XVH300 devices with on-
board Ethernet interface and GALILEO runtime support the DXS client
function. This function requires 80 license points on the device → HMI
/ HMI-PLC licensing.
This product consists of the software with documentation and a license
product paper with 80 points for licensing a device.
Services