For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent
Applications
• Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Food processing plants
— Storage areas
— Waste and sewage treatment
— Parking garages
— Other areas where water, dirt and rough usage are a problem
Features
• Compact in size, attractively styled contemporary design,
rugged and dependable.
• Easy to install and service.
• One-piece housing.
• One-piece lens in hinged cover. Secured by four M6 captive Floodlight
stainless steel slotted hex-head bolts.
• Thermal shock- and impact-resistant glass lens standard.
• Diffused polycarbonate lens available as an option.
• Heavy duty, high temperature silicone rubber gasket,
mechanically secured.
• Universal design for flood and high bay mounting.
• Floodlight Mounting:
— Yoke mount, zinc plated steel yoke with architectural bronze
polyester finish.
• High Bay Mounting:
— (1) Conduit entry on back of luminaire with locking set screw.
— Rotate yoke up or remove.
• Chain Mounting: High Bay
— Mounts via eyebolts threaded into the corners of the fixture.
— Available with chain mounting, or as an accessory.
— Rotate yoke up or remove.
• Cool operating temperatures translate into long luminaire life.
• NEC/CEC versions available with a total of three (3) 3/4" NPT
entries with integral bushings.
• ATEX/IECEx version provided with one (1) 3/4" NPT/M20
adapter and two (2) close up plugs.
• Two (2) 3/4" NPT aluminum close up plugs provided.
• Electrical:
— NEC/CEC/ATEX/IECEx: 120-277 Vac, 50/60 Hz
— NEC/CEC: 347-480 Vac, 50/60 Hz.; 250 Vdc available on
AMLED77YBC.
— ATEX/IECEx: 220-240 Vac, 50/60 Hz.
— Surge Protection Common/Differential Mode: 4KV
• Terminal block (screw type for secure connection) can accept
UL/CSA 24-10AWG and IEC 0.2 - 4 mm2.
Standard Materials
• Housing and lens door: copperfree (4/10 of 1% max.) aluminum
• Gasket: silicone rubber
• Reflector: metallized high reflectance finish
• Yoke mount: zinc plated steel
• Bolts: stainless steel
• Close up plugs: (2) aluminum provided
Standard Finishes
• Housing, lens cover and yoke mount: architectural bronze
polyester
Class I, Zone 2 Group IIC Simultaneous Exposure Wet Locations EPL Gc and Dc EPL Db
Class II, Division 1, Groups Type 3R, 4, 4X Ex nA IIC; Ex tc IIIC Ex tb IIIC
E, F, G IP66/67 IP66, IK08 IK08
90° Rotation
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide — NEC/CEC and ATEX/IECEx Certified Areamaster LED
AMLED 77 Y BU1 FN
Series: Voltage:
AMLED: Areamaster LED Series BU1 - 120-277 Vac, 50/60 Hz
NEC/CEC and ATEX/ BH - 347-480 Vac, 50/60 Hz
IECEx Certified BC - 250 Vdc
Not available for use on the 750 and 1000 Watt equivalent.
Not available for use on the ATEX/IECEx certified fixtures.
Canadian Electrical Code does NOT allow fusing in hazardous locations. Fuse not CEC rated.
Not available for use on the 250, 750 and 1000 Watt equivalent.
For ATEX/IECEx versions.
All lumen values are typical tolerance +/- 10% for glass lens only.
Class I, Zone 2 Group IIC Simultaneous Exposure Wet Locations EPL Gc and Dc EPL Db
Class II, Division 1, Groups Type 3R, 4, 4X Ex nA IIC; Ex tc IIIC Ex tb IIIC
E, F, G IP66/67 IP66, IK08 IK08
T4 T4 T4 T4 T4 T3 68 83 67 82 70 85
AMLED67YBU1
114 (237) 129 (264) 109 (228) 124 (255) 117 (243) 132 (270) (154) (181) (153) (180) (158) (185)
T3 T3 T3 T3 T3 T3 75 90 74 89 77 92
AMLED77YBU1
144 (291) 159 (318) 146 (295) 161 (322) 150 (302) 165 (329) (167) (194) (165) (192 ) (171) (198)
T3 T3 T3 T3 T3 T2 83 98 82 97 87 102
AMLED87YBU1
178 (352) 193 (379) 176 (349) 191 (376) 183 (361) 198 (388) (181) (208) (180) (207) (198) (216)
“T” Numbers Represent the Maximum Internal Temperature or Maximum Surface Temperature
NEC/CEC
“T” # T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp. 351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
Range
(664- (619- (574- (538- (502- (448- (421- (394- (358- (331- (322- (277- (250- (214- (187-
ºC (˚ºF) (185)
842) 662) 617) 572) 536) 500) 446) 419) 392) 356) 329) 320) 275) 248) 212)
ATEX/IECEx
“T” # T1 T2 T3 T4 T5 T6
Temp. 86-
301-450 201-300 136-200 101-135 85
100
Range
(187-
ºC (˚ºF) (547-842) (394-572) (277-392) (214-275) (185)
212)
T numbers represent the maximum internal temperature for Class I, Division 2 and Class I, Zone 2 locations designated by the NEC and ATEX/IECEx.
T numbers represent the maximum surface temperature under a dust blanket for Class II, Division 1 and 2 as designated by the NEC or Zone 2 (Gas) and 22
(Dust) locations as designated by the IEC.
Watts Total
Input Power Input Amps Harmonic Color Temp
Voltage Range Frequency ( Hz) (Nom.) (Max.) Distortion Power Factor CRI CCT Catalog Number
120-277 Vac 50/60 86/85 0.72 - 0.35 0.5 > 0.98 70 5650K AMLED67YBU1
347-480 Vac 50/60 88/90 0.27 - 0.22 0.5 > 0.95 70 5650K AMLED67YBH
120-277 Vac 50/60 125/121 1.10 - 0.47 0.5 > 0.98 70 5650K AMLED77YBU1
347-480 Vac 50/60 124/125 0.37 - 0.29 0.5 > 0.95 70 5650K AMLED77YBH
120-277 Vac 50/60 174/169 1.60 - 0.70 0.5 > 0.98 70 5700K AMLED87YBU1
347-480 Vac 50/60 176/175 0.52 - 0.39 0.5 > 0.95 70 5700K AMLED87YBH
120-277 Vac 50/60 194/188 1.60 - 0.70 0.5 > 0.99 70 5500K AMLED92YBU1
347-480 Vac 50/60 200/199 0.58 - 0.44 0.5 > 0.98 70 5500K AMLED92YBH
Line Voltage
Catalog Number
NEC/CEC ATEX/IECEx
Catalog Number
Description NEC/CEC, ATEX/IEC
Crossarm Mounting Bracket
Has 180° horizontal adjustment — degree marked. Facilitates mounting
floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes
G-AM-8-CA
floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.
Pipe or Wall Mount Bracket
Used with G-AM-8-CA. Clamps to 1” to 2-1/2” pipe, vertical or horizontal,
or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts.
G-AM-8-WB
Malleable iron, zinc plated, chromate sealed, with architectural bronze polyster
finish.
Poletop Slip-Fitter
Slip-fits 1-1/2” or 2” pipe size poletop tenons. Includes floodlight yoke bolts,
3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate
G-SF20
sealed, with cast aluminum cap. Assembly has architectural bronze polyester
finish.
Slip-fits 1" or 1-1/2” pipe size poletop tenons. Includes floodlight yoke bolts,
3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate
AMLEDSF1
sealed, with cast aluminum cap. Assembly has architectural bronze polyester
finish.
Poletop Slip-Fitter
Chain
Chain mount assembly comes with two (2) 914.4 mm (36 inch) long chains,
four (4) eye bolts, four (4) hex bolts, four (4) lock washers, four (4) hex nuts,
eight (8) plain washers and an instruction sheet for complete assembly and AMLEDCM
mounting. Chains are galvanized steel, eye bolts are zinc plated steel, all other
hardware is stainless steel.
Catalog Number
Description NEC/CEC ATEX/IECEx
LED Array
With White LED's for the AMLED67 AMLED67AW AMLED67AW
With White LED's for the AMLED77 AMLED77AW AMLED77AW
With White LED's for the AMLED87 AMLED87AW AMLED87AW
Drivers
120 - 277 Vac — BU Version and BC Version AMLED77DBU —
120 - 277 Vac — BU1 Version — AMLED87: Left Side — AMLED67, AMLED77 AMLEDDBU1L AMLEDDBU1L
120 - 277 Vac — BU1 Version — AMLED87: Right Side AMLEDDBU1R AMLEDDBU1R
347 - 480 Vac — BH Version — AMLED67, AMLED77 AMLED77DBH —
347 - 480 Vac — BH Version — AMLED87: Left Side AMLED87DBHL —
347 - 480 Vac — BH Version — AMLED87: Right Side AMLED87DBHR —
Door Assembly
With a Glass Lens, Pins AMLEDMDOOR AMLEDMDOOR
With a Polycarbonate Lens, Pins AMLEDMDOORP —
182.9 mm
(7.20 in)
358.1 mm Conduit
(14.10 in) Entry 391.2 mm
(Pendant (15.40 in)
Mount)
Set
Screw 144.78 mm
(5.70 in)
Ceiling
Rotate Yoke Up
Recommended Minimum Juction Box or Remove
Mounting Distance Set Screw
304.8 mm (12 in)
152.4 mm
(6 in)
Polar Candela Distribution ISOCANDELA CURVES Zonal Lumen and Percentage at 25 °C (77 °F)
3
Zone Lumens % Lamp % Fixture
0-10 245.6 N.A. 3.0
90˚
10-20 771.8 N.A. 9.4
2
0.1 fc
20-30 1431 N.A. 17.4
0.5 fc
30-40 1842 N.A. 22.4
75˚
1 40-50 1785 N.A. 21.7
1250
2.5 fc 50-60 1448 N.A. 17.6
60-70 667.1 N.A. 8.1
60˚ 0
70-80 43.8 N.A. 0.5
80-90 4.5 N.A. 0.1
1 fc 1
2500
45˚
0.2 fc
2696
2
3750
3
0 1 2
0˚ 15˚ 30˚
Distance in units of mount height (25 ft)
Polar Candela Distribution Zonal Lumen Summary and Percentage at 25 °C (77 °F)
Zone Lumens % Lamp % Fixture
0-30 2434 N.A. 29.2
0-40 4283 N.A. 51.6
0-60 7553 N.A. 90.6
90˚
60-90 780 N.A. 9.4
0-90 8333 N.A. 100.0
75˚ 90-180 0 N.A. 0
0-180 8333 N.A. 100.0
1250
Vertical Angles
25.5 4964 4898 0
22.5 4910 4857
19.5 4700 4660
17.0 4456 4343 2500 -30
65 1239 938
55 3463 3477 581.8
60
47.5 4393 4345
42.5 4921 4831 2909
Vertical Angles
29 6656 6778
25.5 6998 7087 0
3 6003 5995
1 6002 6004
0 5999 5999
65 1903 1963
1087.48
55 5245 5337
60
47.5 6242 6344 5437.4
42.5 6793 6886
37.5 7786 8040 30
33 8717 8835
Vertical Angles
29 9328 9275 2719