CSP 3000 Spec
CSP 3000 Spec
CSP 3000 Spec
■ ■
‧ ‧
‧ ‧
‧ ‧
‧ ‧
‧ ‧
‧ ‧
‧ ■
‧
‧
‧1
■
℃
■
PFC O.V.P.
CONTROL O.L.P.
PWM
DETECTION
O.T.P. CONTROL CIRCUIT P OK
REMOTE RC
CONTROL
LOAD CS
SHARING
FAN
AUX RECTIFIERS
POWER & AUX POWER
FILTER (12V/0.4A)
100
100
90
80
80
LOAD (%)
LOAD (%)
70 60
60 50
40
50
20
40
94
92
EFFICIENCY (%)
90
88
86
84
82
80
78
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
◎ CSP-3000-120 ◎ CSP-3000-250
130V 260V
1.36A, 250V 9A,250V
12A, 250V
125V
2.4A, 120V 15A,120V
240V
120V 25A,120V
220V
115V
110V 200V
105V 180V
17A, 176.5V
100V 30A,100V
160V
95V
140V
90V 30A,90V
2.4A, 90V 17A, 125V
85V 120V
1.36A, 125V
80V 100V
0A 5A 10A 15A 20A 25A 30A 35A 0A 3A 6A 9A 12A 15A 18A
Recommended High Performance Region Allowed Operational Region Recommended High Performance Region Allowed Operational Region
◎ CSP-3000-400
430V
0.8A, 400V 5.25A,400V 7.5A, 400V
400V
370V
340V
10A,300V
310V
280V
250V
220V
190V
0.8A, 200V 10A,200V
160V
130V
100V
0A 1.5A 3A 4.5A 6A 7.5A 9A 10.5A 12A 13.5A 15A
Function Manual
1. Output Voltage/Current Programming
※ Mode Setting
CN1:
CONDITION MODE FUNCTION
※ The factory default settings:PV mode output max voltage pin5/pin6 short by jumper cap.
When pull out the jumper cap,the default settings: PC mode output max constant current.
PIN6
PIN5
PV/PC MODE CHOSE
CN1
PV/PC SET(SVR2)
max.
PIN6
PIN5 PV/PC ADJUST
CN2
Vout Iout
100 100
CURRENT ADJUSTMENT /(%)
VOLTAGE ADJUSTMENT /(%)
80 80
Non-Linear Non-Linear
60 60
40 40
15
8
1.5 4 6 8 10 V 0.8 4 6 8 10 V
15 40 60 80 100 % 8 40 60 80 100 %
PIN5/PIN6 ACCESS TO EXTERNEL VOLTAGE SIGNALS(DC/PWM) PIN5/PIN6 ACCESS TO EXTERNEL VOLTAGE SIGNALS(DC/PWM)
2.Remote ON-OFF
※ Remote ON-OFF is activated by the configuration with respect to CN1 as shown in the following diagram.
PIN3 RC
PIN1 RCG
CN1
AUX
1KΩ 12V
RC
Internal
12V typ.
SW
RCG
AUXG
AUX
1KΩ RC
Internal
12V typ.
RCG
SW
AUXG
AUX
1KΩ
1KΩ RC
Internal
12V typ. SW
RCG
AUXG
◎ Connection Method
Example 2.2(A) Example 2.2(B) Example 2.2(C)
Power supply output ON SW Open(open) SW Open(open) SW Close(short)
SW Logic
Power supply output OFF SW Close(short) SW Close(short) SW Open(open)
PIN9(P-OK-GND) PIN4(P-OK-GND-2)
PIN7(P-OK) PIN2(P-OK-2)
CN1
Function Description Output of alarm(P OK, Relay Contact) Output of alarm(P OK2, TTL Signal)
The signal is "Low" when the power supply is above Low Low
80% of the rated output voltage, or, say, Power OK (0.5V max at 500mA) (0.5V max at 10mA)
P OK
The signal turns to be "High" when the power supply
High or open High or open
is under 80% of the rated output voltage, or, say,
(External applied voltage, 500mA max.) (External applied voltage, 10mA max.)
Power Fail
P OK P OK2
R R
V 0.1uF V
Fig. 3.2 Internal circuit of P OK (Relay, total is 10W) Fig. 3.3 Internal circuit of P OK2 (Open collector method)
PIN5 PIN5
PIN6 PIN6
Fig. 4.1 Insert the CN1 Fig. 4.2 Remove the CN1
Overload Protection Type : constant current limiting with delay shutdown after 3 seconds Overload Protection Type : constant current limiting
5.Current Sharing
CSP-3000 has the built-in active current sharing function and can be connected in parallel, up to 3 units, to provide higher output power as exhibited below :
※ The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
※ Difference of output voltages among parallel units should be less than 0.2V(Can Fine tune by SVR1).
※ The total output current must not exceed the value determined by the following equation:
Maximum output current at parallel operation=(Rated current per unit)×(Number of unit)×0.9
※ When out current<( 50% rate current)×(Number of unit),
the current shared among units may not be fully balanced.
+V
-V
+V
No.2(Slave) Load
-V
+V
-V
No.3(Slave)
+V
-V
Mechanical Specification
Case No.982B Unit:mm
278
236.3 27
12.5
63.5
CN1 CN2
38
1 1
10 8 6 4 2 8642
236.3 27 19max.
7.9
4-M4 L=5mm
16
1 1
13
OUTPUT
177.8
Air flow
162
direction
INPUT
10
13
1 1
16max.
1 2
7 8
Mating Housing HRS DF11-8DS or equivalent
1 2 Terminal HRS DF11-**SC or equivalent
Installation Manual