1.
ESDS bags are sealed by
a) zip locks
b) ESDS labels
c) twine (100% cotton)
2. What are the values of an ESDS wrist strap?
a) 250 kilohms to 1.5 megohms
b) 2 megohms to 5 megohms
c) 2 gigohms to 4 gigohms
3. What precautions are required when removing ESDS equipment
a) Wear a wrist strap connected to an approved ground point
b) Keep one hand on the airframe
c) No special precautions are required
4. A symbol generator displays ESDs warning. During replacement
a) you must wear a wrist strap connected to an approved earth point
b) make sure the pins are not touched and covers fitted
c) you must earth the unit to the airframe structure
5. A flight deck CRT LRU is being replaced. What does the ESDS label indicate?
a) Wrist straps should be worn
b) Do not touch plug pins or leave them exposed
c) Remove power before connecting
6. When using a wrist strap, before touching the LRU the resistance should be measured from your skin
to the end of the earth probe. This should be
a) more than 10 kilohms
b) less than 10 kilohms
c) less than 1 ohm
7. During an EFIS screen fit
a) use bonding strap
b) don’t touch terminals
c) no tooling is required
8. To stop earth loops forming, you would
a) leave both ends of the cable screen open circuit
b) earth both ends of the cable screen
c) earth only one end of the cable screen
9. The resistance of the wrist strap used as part of anti static precautions should be
a) 0 - 200 ohm
b) 250 kilohm - 1.5 megohm
c) 20 megohm - 200 megohm
10. How are earth loops prevented from forming?
a) Ground only one end of the cable screen
b) Ground both ends of the cable screen
c) Ground neither end of the cable screen
11. When carrying out a bonding check on a surface protected by anodic film
a) the anodic film should be removed locally to ensure a good contact
b) the film is conductive so no preparations are required
c) add a bonding factor to the result of the test to account for the resistance of the anodic film
12. When clamping cable looms containing co-axial cables
a) avoid distortion to the co-axial cable to maintain the dielectric constant
b) distortion of the outer sheath is allowed providing the inner cable is not affected
c) the clamps must be no more than 1 metre apart
13. When incorporating an aerial cable it must be
a) in the centre of the other wires
b) outside the other wires for easy access
c) positioned separately from the loom
14. Ribbon cables affected by mutual impedance and current loop leakage are protected by
a) earthing each conductor
b) earthing each alternate conductor
c) wrapping the complete ribbon in an earthed shield
15. When handling PCB's labelled ESDS, what precaution are taken?
a) Isolate electrical power before installing on Aircraft
b) First earth with aircraft then to it
c) Do not touch its pins as copper contamination can occur
16. After attaching a wrist strap to you wrist (which is connected to aircraft ground), prior to removal
of ESDS equipment, the resistance measured
a) between the strap and the pin ground must be >10 Megohms
b) between your skin and the pin ground must be <10 megohms
c) between the strap and the pin ground must be <10 meghms
17. When handling a PCB you should ensure that
a) electrical power is isolated
b) ground yourself first to aircraft then PCB
c) ensure you do not touch the ends so that copper contacts do not become contaminated
18. for braided cables, the amount of braiding
a) is a trade-off design feature
b) must conform to the requirement for the shielding to cover at least 50% of the surface of the
cable
c) keeps radiated power inside the emitting assembly or away from the susceptible circuit
19. Which of the following ESDS devices can withstand higher static electricity voltage?
a) ECL
b) MOSFET
c) SCR
20. Ribbon cables effected by mutual impedance and current loop leakage should be protected by
a) shielding each individual conductor
b) connecting all conductors to a common earth
c) earthing each alternative conductor to separate point
21. To shield a fibre optic from EMI you must
a) earth both transducer and couplings
b) shield it with a braided shield
c) use an opto-isolator
22. With a relative humidity of 10% to 20%, if you walked over a carpet what electrostatic voltage
value would you expect to see?
a) 6,000 volts
b) 12,000 volts
c) 35,000 volts
23. Before fitting a Printed Circuit Board you should check the
a) resistance between skin and strap end plug is less than 10 megohms
b) resistance between skin and strap end plug is more than 1 megohms
c) resistance between strap and strap end plug is less than 1 megohms
1 C 11 A 21 C 31 41 51
2 A 12 A 22 C 32 42 52
3 A 13 C 23 B 33 43 53
4 B 14 B 24 34 44 54
5 B 15 A 25 35 45 55
6 A 16 B 26 36 46 56
7 B 17 B 27 37 47 57
8 C 18 C 28 38 48 58
9 C 19 C 29 39 49 59
10 A 20 C 30 40 50 60