Structural Residence

Lighting in architecture- Building Utilities 3 Deisng lighting Lighting in architecture- Building Utilities 3 Deisng lighting

Uploaded by

2226558
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
98 views4 pages

Structural Residence

Lighting in architecture- Building Utilities 3 Deisng lighting Lighting in architecture- Building Utilities 3 Deisng lighting

Uploaded by

2226558
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

CONSTRUCTION NOTES

A. GENERAL NOTES

d
1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR STANDARD HOOKS, ALL GRADES
NOTED MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS. F. MASONRY WORKS
2. THE CONTRACTOR SHALL EXAMINE THE DRAWINGS AND SHALL NOTIFY THE ENGINEER/ARCHITECT OF ANY 1. ALL NON-LOAD BEARING TYPE CONCRETE BLOCKS SHALL HAVE A UNIT WEIGHT NOT TO EXCEED 80 PCF. FOR BAR SIZE FINISHED BEND STANDARD HOOKS
DISCREPANCIES HE MAY FINDBEFORE PROCEEDING WITH THE WORK, OR DURING CONSTRUCTION. LOAD BEARING TYPE, TYPE CONCRETE BLOCKS, A MINIMUM COMPRESSIVE STRENGTH OF 6.90 MPA SHALL BE
DEVELOPED. (GR. 60) DIAMETER, D 90° 180°
3. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORING & BRACINGS OF
THE STRUCTURE FOR ALL LOADS THAT MAYBE IMPOSED DURING CONSTRUCTION. 2. PROVIDE 1-Ø16 VERTICAL BARS AT CORNERS, INTERSECTIONS, END OF WALLS AND EACH SIDE OF OPENINGS. (MM) X (MM) Y (MM)
4. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEELS, 3. LINTEL BEAMS SHALL BEAR AT LEAST 8 INCHES (200 MM) ON EACH SIDE OF MASONRY WALL OPENING.
MISCELLANEOUS IRON, PRE-CAST CONCRETE ETC. SHALL BE SUBMITTED FOR ENGINEERS 4. WALL REINFORCEMENTS SHALL BE AS FOLLOWS. 10mmØ (#3) 60 180 100
APPROVAL BEFORE FABRICATION.
5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN CHECK WITH MECHANICAL WALL THICKNESS VERTICAL REINFORCEMENT HORIZONTAL REINFORCEMENT
12mmØ (#4) 72 216 120
180 DEG
AND ELECTRICAL CONTRACTORS FOR CONDUITS PIPE SLEEVES, ETC., TO BE EMBEDDED IN CONCRETE. 8 IN. (200 MM) Ø12 @ 600 MM Ø10 @ 600 MM
6. INSPECTION - ALL CONSTRUCTION AND WORKMANSHIP SHALL BE SUBJECT TO INSPECTION, EXAMINATION 6 IN. (150 MM) Ø12 @ 600 MM Ø10 @ 600 MM
AND TESTING BY THE ENGINEER. THE ENGINEER SHALL HAVE THE RIGHT REJECT DEFECTIVE MATERIALS AND 4 IN. (100 MM) Ø10 @ 600 MM Ø10 @ 600 MM 16mmØ (#5) 96 288 160
WORKMANSHIP OR REQUIRE ITS CORRECTION.

d
7. ALL SLABS, BEAMS, GIRDERS AND OTHER STRUCTURAL ELEMENTS WHICH ARE NOT INDICATED, DETAILED, 5. REINFORCING BARS SHALL BE LAPPED A MINIMUM OF 40 BAR DIAMETERS WHERE SPLICE DOWELS FROM FOOTING 20mmØ (#6) 120 360 200
DESIGNATED OR INADVERTENTLY OMITTED BUT ARE NECESSARY TO BE COORDINATED WITH THE OR SLABS SHALL EXTEND INTO THE BLOCK WALL A MINIMUM OF 40 BAR DIAMETERS, AND DOWELS TO MATCH.
ARCHITECTURAL AND OTHER ENGINEERING PLANS AS WELL AS TO COMPLETE THE STRUCTURAL WORK 6. ALL CELLS CONTAINING REINFORCING BARS OR INSERTS SHALL BE SOLIDLY FILLED WITH CONCRETE GROUT 22mmØ (#7) 132 396 220
IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS SHALL BE BROUGHT UP DURING (REFER TO SPECIFICATIONS).
PRE-BIDS/MEETINGS/NEGOTIATIONS. IT IS UNDERSTOOD THAT THE CONTRACTOR HAS PROVIDED AND INCLUDED
ALL THESE ITEMS IN THEIR BID. 25mmØ (#8) 150 450 250
ITEMS COVER

B. FOUNDATION NOTES CONCRETE CAST AGAINST EARTH 75mm 28mmØ (#9) 224 560 336
1. ASSUMED BEARING CAPACITY IS 100 kPa.
a. BOTTOM OF FOOTINGS SHOULD BE SOLID GROUND. ACTUAL DEPTH TO BE APPROVED BY THE ENGINEER. EXPOSED TO EXTERIOR OR WEATHER 50mm 32mmØ (#10) 256 640 384
b. SOIL BEARING CAPACITY SHALL BE INCREASED BY 33% WHEN COMBINATION WITH
90 DEG 90 DEG 135 DEG
FORMED SURFACE BELOW GRADE 50mm
SEISMIC OR WIND LOAD. 36mmØ (#11) 288 720 432
2. ALL COLUMN FOOTINGS SHALL REST ON 0.10m THICK WELL COMPACTED GRAVEL BASE COURSE. SLAB ON GRADE 50mm
3. BACKFILL SHALL BE PACED IN 0.20m LAYERS AND EACH LAYER SHALL BE COMPACTED TO
95%MAXIMUM DRY DENSITY. COLUMNS/SHEARWALLS AND BEAMS 40mm STANDARD HOOKS
4. WHERE LOOSE/SOFT MATERIAL IS ENCOUNTERED AT DEPTH OF EMBEDMENT EXCAVAVATE TO FIRM LAYER OR TO
STIRRUPS AND TIE-HOOKS
STRUCTURAL SLABS TOP AND BOTTOM (INTERIOR) 25mm
MAXIMUM OF 0.10m AND REPLACE LOOSE/SOFT MATERIALS UNDERNEATH THE FOOTING WITHIN THE FOOTING
AREA PLUS 1/2 OF THE DEPTH OF EXCAVATED SOFT MATERIAL ON ALL SIDES WITH SELECTED SAND/GRAVEL R.C. WALLS 20mm
BACKFILL MATERIALS COMPACTED AS DESIRED BY THE ENGINEER. CONCRETE HOLLOW BLOCKS REINFORCEMENT
5. THE STRUCTURAL ENGINEER-OF-RECORD, UPON NOTIFICATION, SHALL CONDUCT THOROUGH INSPECTION OF
CHB STIFFENER DETAILS
FOUNDATION WORKS AFTER EXCAVATION BEFORE FOOTINGS ARE COMPLETED. NO REINFORCING STEEL OR 6. WELDING OF REINFORCING STEEL IS NOT PERMITTED UNLESS MATERIAL TEST RESULT PROVES THAT THE BAR IS NOTE:
FORMWORKS SHALL BE PLACED PRIOR TO INSPECTION. CONCRETE POURING OF THE FOUNDATION SYSTEM WELDABLE. PROVIDE VERTICAL STIFFENERS EVERY 3000mm O.C. MAXIMUM
SHALL NOT BE ALLOWED WITHOUT FIRST OBTAINING WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER- 7. SHOP DRAWINGS: THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR REINFORCING STEEL PREPARED IN PROVIDE HORIZONTAL STIFFENERS EVERY 3000mm O.C. MAXIMUM
ON-RECORD. ACCORDANCE WITH ACI 315. INDICATE BENDING DIAGRAM, ASSEMBLY DIAGRAM, SPLICING AND LAPS OF RODS
AND SHAPES DIMENSIONS AND DETAILS FOR REINFORCING BARS.
C. SLAB-ON-GRADE NOTES 8. ANCHOR BOLTS, DOWELS, AND OTHER EMBEDDED ITEMS ARE TO BE SECURELY TIED IN PLACE BEFORE
1. THE SOIL, SUBGRADE AND FILL LAYERS BELOW ALL CONCRETE IS POURED. VERTICAL STIFFENER
SLABS-ON-GRADE, PAVING AND PIT SLABS SHALL BE
MECHANICALLY COMPACTED IN 200MM THICK LAYERS TO A
MINIMUM OF 95 PERCENT MDD. SCHEDULE OF DEVELOPMENT LENGTH
2. ALL SLAB-ON-GRADE SHALL BE PROVIDED WITH A MINIMUM
OF 100MM THICK COMPACTED CLEAN COARSE BAR SIZE DEVELOPMENT LENGTH (Ld)
GRAVEL BED, EXCEPT AS OTHERWISE DETAILED IN THE (GR. 60) f'c = 21MPa f'c = 28MPa f'c = 34MPa f'c = 42MPa f'c = 48MPa f'c = 55MPa f'c = 68MPa
PLANS. (3000 psi) (4000 psi) (5000 psi) (6000 psi) (7000 psi) (8000 psi) (10000 psi)
3. ALL SLAB-ON-GRADE ARE NOT DESIGNED AS PRESSURE SLAB 10mmØ (#3) 450 400 350 325 300 275 250
UNLESS OTHERWISE INDICATED ON PLAN.
4. SLAB-ON-GRADE SHALL BE 100MM THICK WITH 10MM DIA. 12mmØ (#4) 525 475 425 375 350 325 300
BARS SPACED AT 0.60M O.C. CONCRETE WALLS:
16mmØ (#5) 700 625 550 500 475 425 400
D. CONCRETE NOTES
20mmØ (#6) 875 775 675 625 575 550 475
ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF THE NATIONAL STRUCTURAL
CODE OF THE PHILIPPINES (NSCP) 2015 OR THE AMERICAN CONCRETE INSTITUTE BUILDING CODE FOR REINFORCED 22mmØ (#7) 975 850 750 675 625 600 525
CONCRETE ACI 318 - EXCEPT AS MODIFIED HEREIN.
1. CONSTRUCTION OR COLD JOINTS SHALL BE LOCATED WITHIN THE MIDDE THIRD OF SPANS OF SLABS, BEAMS, 25mmØ (#8) 1350 1175 1050 950 900 825 750
AND GIRDERS FOR CASE UNAVOIDABLE, PROPOSED LOCATION MUST BE APPROVED FIRST BY THE STRUCTURAL HORIZONTAL STIFFENER
ENGINEER. 28mmØ (#9) 1500 1300 1175 1075 1000 925 825
2. PIPES OR DUCTS EXCEEDING ONE THIRD THE SLAB OR WALL THICKNESS SHALL NOT BE PLACED IN STRUCTURAL
CONCRETE UNLESS SPECIFICALLY DETAILED. 32mmØ (#10) 1725 1500 1350 1225 1125 1050 950
3. REINFORCING BARS, ANCHOR BOLTS, AND OTHER INSERTS SHALL BE SECURED IN PLACE BEFORE POURING 36mmØ (#11) 1950 1675 1500 1375 1275 1200 1075
CONCRETE. BAR PLACEMENT AND SUPPORTS SHALL BE IN ACCORDANCE WITH THE RECOMMENDED ACI PRACTICE.
4. ALL INSERTS, ANCHOR BOLTS, ETC. TO BE EMBEDDED IN THE CONCRETE SHALL BE HOT DIP GALVANIZED UNLESS
NOTED OTHERWISE. SCHEDULE OF LAP SPLICE
5. IN GENERAL, THE LATEST EDITION OF THE MANUAL OF STANDARD PRACTICE FOR DETAILING CONCRETE LAP SPLICE (Lb)
BAR SIZE
STRUCTURES, ACI 315, SHALL BE ADHERED TO, UNLESS SHOWN OTHERWISE.
(GR. 60) f'c = 21MPa f'c = 28MPa f'c = 34MPa f'c = 42MPa f'c = 48MPa f'c = 55MPa f'c = 68MPa
6. USE OF ADMIXTURES IS PERMITTED TO PRODUCE PROPER SLUMP AND WORKABILITY BUT SUBJECT TO THE
(3000 psi) (4000 psi) (5000 psi) (6000 psi) (7000 psi) (8000 psi) (10000 psi)
ENGINEER'S APPROVAL. ADDITION OF WATER TO CONCRETE AT JOB SITE IS NOT ALLOWED.
7. PREPARE AND SUBMIT CONCRETE MIX DESIG INCLUDING AGGREGATES GRADATION, WATER AND CEMENT 10mmØ (#3) 600 525 475 425 400 375 325
CONTENTS, AND CYLINDER STRENGTH TEST RESULT FOR REVIEW.
12mmØ (#4) 700 625 575 500 475 425 400
SCHEDULE OF STRUCTURAL CONCRETE SCHEDULE OF CONCRETE 16mmØ (#5) 925 825 725 650 625 575 525
AT 28 DAYS COMPRESSIVE STRENGTH AGGREGATES
20mmØ (#6) 1150 1025 900 825 750 725 625

LOCATION STRUCTURAL 28-DAY COMPRESSIVE MAX. SLUMP ITEMS MAXIMUM 22mmØ (#7) 1275 1125 975 900 825 800 700
ELEMENTS STRENGTH MPa (psi) mm (in.) AGGREGATE SIZE
25mmØ (#8) 1775 1550 1375 1250 1175 1075 975
FOUNDATION FOOTING 20.7 (3000) 100 (4") FOOTINGS 19 mm (3/4")
28mmØ (#9) 1950 1700 1550 1400 1300 1225 1075
GROUND LEVEL SLAB ON GRADE 17.3 (2500) 100 (4") SLABS 13 mm (1/2")
32mmØ (#10) 2250 1950 1775 1600 1475 1375 1250
ALL LEVELS SLAB 20.7 (3000) 100 (4") WALLS 19 mm (3/4")
36mmØ (#11) 2550 2200 1950 1800 1675 1575 1400
ALL LEVELS BEAMS 20.7 (3000) 100 (4") BEAMS 19 mm (3/4")
SCHEDULE OF DEVELOPMENT LENGTH OF STANDARD HOOKS
ALL LEVELS COLUMNS 20.7 (3000) 100 (4") COLUMNS 19 mm (3/4")
BAR SIZE DEVELOPMENT LENGTH OF STANDARD HOOKS (Ldh)
(GR. 60) f'c = 21MPa f'c = 28MPa f'c = 34MPa f'c = 42MPa f'c = 48MPa f'c = 55MPa f'c = 68MPa
E. REINFORCING STEEL NOTES (3000 psi) (4000 psi) (5000 psi) (6000 psi) (7000 psi) (8000 psi) (10000 psi)
ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF THE NATIONAL STRUCTURAL 10mmØ (#3) 220 190 170 155 150 150 150
CODE OF THE PHILIPPINES (NSCP) 2015 OR THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION FOR REINFORCING STEEL AND
REINFORCING BARS EXCEPT AS MODIFIED HEREIN. 12mmØ (#4) 265 230 205 190 175 165 150

16mmØ (#5) 350 305 275 250 230 215 195


1. BARS SHALL BE CLEAN OF RUST, GREASE OR OTHER MATERIALS LIKELY TO IMPAIR BOND. ALL REINFORCING BAR
BEND SHALL BE MADE COLD. 20mmØ (#6) 440 380 340 310 290 270 240
2. IN GENERAL, BAR SPLICES SHALL BE MADE AT POINTS OF MINIMUM STRESS. SPLICES SHALL BE SECURELY WIRED
TOGETHER STAGGER SPLICES AT LEAST 600mm. WHENEVER POSSIBLE IN BEAMS AND SLABS, SPLICE TOP BAR AT 22mmØ (#7) 485 420 375 340 315 295 265
MIDSPAN AND BOTTOM BARS NEAR SUPPORT. SPLICE OF REINFORCEMENT SHALL BE MADE ONLY AS REQUIRED
OR PERMITTED ON DESIGN DRAWINGS OR AS ALLOWED BY THE ACI CODE OR AS AUTHORIZED BY THE 25mmØ (#8) 550 475 425 390 360 335 300
ENGINEERS.
28mmØ (#9) 615 530 475 435 405 375 340
3. BARS NOTED AS CONTINUOUS SHALL HAVE A MINIMUM SPLICE LENGTH OF 40 BAR DIAMETER BUT NOT LESS
THAN 300mm UNLESS OTHERWISE NOTED. 32mmØ (#10) 700 610 545 495 460 430 385
4. REINFORCEMENT SHALL BE SPLICED ONLY AS INDICATED IN THE DRAWINGS.
36mmØ (#11) 790 685 610 560 515 485 435

BAR SIZE DEVELOPMENT LENGTH OF STANDARD HOOKS (Ldh)


(GR. 40) f'c = 21MPa f'c = 28MPa f'c = 34MPa f'c = 42MPa f'c = 48MPa f'c = 55MPa f'c = 68MPa
(3000 psi) (4000 psi) (5000 psi) (6000 psi) (7000 psi) (8000 psi) (10000 psi)

10mmØ (#3) 150 150 150 150 150 150 150

12mmØ (#4) 175 155 150 150 150 150 150

CIVIL ENGINEER CLIENT SHEET CONTENT REVISIONS SHEET NO.


DRAWINGS AS INSTRUMENTS OF SERVICE GENERAL CONSTRUCTION
ARE THE PROPERTY OF THE COMPANY AND HAROLD LAENON L. BINDADAN MR. ENGELBERT VINOYA & MRS. MARY GYPSY VINOYA ST00 - 0.0.0
NOTES
SUCH MUST NOT BE REPRODUCED OR
COPIED IN PART OR IN WHOLE WITHOUT PTR NO : REG NO : PROJECT LOCATION PROJECT MILESTONE
THE WRITTEN PERMISSION. OF THE 7650324 145691
ISSUED ON : ISSUED AT :
ONE STOREY COMMERCIAL BUILDING TURAC, SAN CARLOS CITY, FOR PERMIT
ARCHITECT / ENGINEER.
01/11/2023 TUBA, BENGUET PANGASINAN
LD
3875 3875 LD

LINKS
LINKS

4-T16 4-T16

REF COL DET


REF COL DET

D12@200 C/C (B) D12@200 C/C (B)

EL. 0 m EL. 0 m
BOF BOF

300
300
300
300

C1 C2 C3
0 THK PCC
FC1 FC2 FC3 D12@200 C/C (B)
D12@200 C/C (B)
1200 1200

SECTION 1-1 2 SECTION 2-2

4850
D12@200 C/C (B)

D12@200 C/C
1 (B)
1

C4 C5 C6
1200
FC4 FC5 FC6

1200
0 THK PCC

FOOTING FC1- PLAN


S2 FOUNDATION PLAN
A SCALE: 1:100
S2 FOOTING SECTION DETAILS
SCALE: NTS
B

SHORT DIR D12@200 C/C D12@200 C/C D12@200 C/C D12@200 C/C D12@200 C/C D12@200 C/C

LONG DIR D12@200 C/C D12@200 C/C D12@200 C/C D12@200 C/C D12@200 C/C D12@200 C/C
FOOTING
D,d 300 300 300 300 300 300

C21:Fy414
SIZE 1200 x 1200 1200 x 1200 1200 x 1200 1200 x 1200 1200 x 1200 1200 x 1200

P.C.C 0 THK 1200 x 1200 1200 x 1200 1200 x 1200 1200 x 1200 1200 x 1200 1200 x 1200

C15
COLUMNS MARKED C1 C2 C3 C4 C5 C6

FOOTING SCHEDULE

S2 FOOTING SCHEDULE
SCALE: NTS
C
CIVIL ENGINEER CLIENT SHEET CONTENT REVISIONS SHEET NO.
DRAWINGS AS INSTRUMENTS OF SERVICE FOUNDATION PLAN
ARE THE PROPERTY OF THE COMPANY AND HAROLD LAENON L. BINDADAN MR. ENGELBERT VINOYA & MRS. MARY GYPSY VINOYA ST00 - 1.0.0
SUCH MUST NOT BE REPRODUCED OR
COPIED IN PART OR IN WHOLE WITHOUT PTR NO : REG NO : PROJECT LOCATION PROJECT MILESTONE
THE WRITTEN PERMISSION. OF THE 7650324 145691
ISSUED ON : ISSUED AT :
ONE STOREY COMMERCIAL BUILDING TURAC, SAN CARLOS CITY, FOR PERMIT
ARCHITECT / ENGINEER.
01/11/2023 TUBA, BENGUET PANGASINAN
(1) 4-D16

250
(1) 4-D16 (1) 4-D16

250
250
250
EL. 4.500 250 EL. 4.500 250
TOC EL. 4.500
TOC
C21 : Fy414 (M) : Fy276 (S) , COVER = 40mm C21 : Fy414 (M) : Fy276 (S) , COVER = 40mm TOC
CONFINING ZONE = FULL HEIGHT CONFINING ZONE = FULL HEIGHT

750
750
(1) 4-D16

(2) D10
(1) 4-D16

750

(2) D10

@50 C/C
4.5 M

@50 C/C
(2) D10
@50 C/C
1 1 1 1 (1) 4-D16

440
440

(2) D10
440

(2) D10

@125 C/C
@125 C/C
(2) D10
@125 C/C
1 1
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS

930
930
TO

(2) D10
930

(2) D10
D10 @ 50 --- --- D16 @ 50 --- ---

@125 C/C
@125 C/C
(2) D10
@125 C/C

440
440

(2) D10
4.923 M

440

(2) D10

@125 C/C
EL. 1.500

@125 C/C
(2) D10
EL. 1.500

@125 C/C

250
250
TOC EL. 1.500
D16 D16 TOC

(2) D10
(2) D10

@50 C/C
TOC

@50 C/C
(2) D10
250 250

@50 C/C

300 450
300 450

(2) D10
300 450

(2) D10

@50 C/C
@50 C/C
4-D16 4-D16

(2) D10
@50 C/C
C21 : Fy414 (M) : Fy276 (S) , COVER = 40mm C21 : Fy414 (M) : Fy276 (S) , COVER = 40mm C21 : Fy414 (M) : Fy276 (S) , COVER = 40mm
CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM

(2) D10
(2) D10

@50 C/C
EL. 0

@50 C/C
(2) D10
EL. 0
@50 C/C

1.5 M BOF EL. 0


BOF
BOF

DETAIL OF COLUMN C1 DETAIL OF COLUMN C2


DETAIL OF COLUMN C3
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
TO
D10 @ 50 --- D10 @ 125 D10 @ 50 --- D10 @ 125 D10 @ 50 --- D10 @ 125

4.5 M

250
250
250
D16 D16 D16
250 250 250

4-D16 4-D16 4-D16


C21 : Fy414 (M) : Fy276 (S) , COVER = 40mm C21 : Fy414 (M) : Fy276 (S) , COVER = 40mm C21 : Fy414 (M) : Fy276 (S) , COVER = 40mm
CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM

0M

(1) 4-D16 (1) 4-D16

250
250

Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS (1) 4-D16

250
TO
D10 @ 50 --- D10 @ 100 D10 @ 50 --- D10 @ 100 D10 @ 50 --- D10 @ 125 250
250 250
EL. 4.920 EL. 4.920
EL. 4.920 TOC TOC
1.5 M TOC EL. 4.500
EL. 4.500
EL. 4.500

250
250
250
TOC TOC
D16 D16 D16 (1) 4-D16
TOC (1) 4-D16
250 250 250 (1) 4-D16
750

1 1
750

4-D16 4-D16 4-D16 1 1


(2) D10 (2) D10

(1) 4-D16
@50 C/C@50 C/C

(2) D10 (2) D16

750
@50 C/C@50 C/C

1 1 (1) 4-D16

(2) D10 (2) D10


(1) 4-D16

@50 C/C@50 C/C


COLUMN MARKED C1, C2, C3 C4, C6 C5 1 1
440

440
(2) D10

1 1
(2) D10

440
@125 C/C

1 1
@125 C/C

(2) D10
@125 C/C
930

930
(2) D10

COLUMN AND WALL SCHEDULE


(2) D10

930
@125 C/C

@125 C/C

(2) D10
(SCALE 1:25)

@125 C/C
440

NOTES:
440
(2) D10

(2) D10

440
@125 C/C

EL. 1.500
@125 C/C

(2) D10
1. BE = BOUNDARY ELEMENT AS PER NSCP C101 - 2015. PROVIDE CONFINING REINFORCEMENT ACROSS ENTIRE HEIGHT OF WALL IN THE BOUNDARY ELEMENT EL. 1.500

@125 C/C
EL. 1.500 TOC
450

TOC
(2) D10
@50 C/C

(2) D10

2. Z1 = SPECIAL CONFINING ZONE AS PER NSCP C101 - 2015, Z2 = REMAINING ZONES AS PER NSCP C101 - 2015

450
@50 C/C

TOC

(2) D10
300 450

@50 C/C
300

3. (M) - STEEL GRADE FOR MAIN REINFORCEMENT


(2) D10
@50 C/C

(2) D10

300
@50 C/C

(2) D10
(1) 4-D16

@50 C/C
4. (S) - STEEL GRADE FOR SHEAR REINFORCEMENT/LINKS
(2) D10

(2) D10
@50 C/C

EL. 0
@50 C/C

EL. 0

(2) D10
@50 C/C
EL. 0 BOF
BOF
BOF

DETAIL OF COLUMN C5 DETAIL OF COLUMN C6


DETAIL OF COLUMN C4

S2 COLUMN SECTION DETAILS S2 COLUMN DETAILS


B SCALE: NTS SCALE: NTS
A

CIVIL ENGINEER CLIENT SHEET CONTENT REVISIONS SHEET NO.


DRAWINGS AS INSTRUMENTS OF SERVICE COLUMN STRUCTURAL DETAILS
ARE THE PROPERTY OF THE COMPANY AND HAROLD LAENON L. BINDADAN MR. ENGELBERT VINOYA & MRS. MARY GYPSY VINOYA ST00 - 2.0.0
SUCH MUST NOT BE REPRODUCED OR
COPIED IN PART OR IN WHOLE WITHOUT PTR NO : REG NO : PROJECT LOCATION PROJECT MILESTONE
THE WRITTEN PERMISSION. OF THE 7650324 145691
ISSUED ON : ISSUED AT :
ONE STOREY COMMERCIAL BUILDING TURAC, SAN CARLOS CITY, FOR PERMIT
ARCHITECT / ENGINEER.
01/11/2023 TUBA, BENGUET PANGASINAN
3875 3875
3875 3875

B1 B2
B1 B2
C1 C2 C3
C1 C2 C3

SLAB ON FILL 100MM SLAB ON FILL 100MM


USE D10MM BARS USE D10MM BARS

B5
B6
B7

SPACED @ 200MM SPACED @ 200MM

4850

B5
B6
B7
BOTH WAYS BOTH WAYS

4850
B3 B4
B3 B4
C4 C5 C6
C4 C5 C6

S3 GROUND FLR FRAME PLAN S4 ROOF FRAME PLAN


A SCALE: 1:100
A SCALE: 1:100

BEAM SCHEDULE (C21 : Fy414 (MAIN) : Fy276 (SHEAR)) (LEVEL: 1.5 m)

BEAM SIZE BOTTOM REINFORCEMENT TOP REINFORCEMENT SHEAR STIRRUPS

NUMBERS B D LEFT MID SPAN RIGHT LEFT MID SPAN RIGHT LEFT MID SPAN RIGHT
B1,B2,B3,B4 250 300 2-D12 2-D12 2-D12 3-D12 3-D12 3-D12 11-2L-D10@60 C/C 24-2L-D10@100 C/C 11-2L-D10@60 C/C

B5,B6,B7 250 300 2-D12 2-D12 2-D12 3-D12 3-D12 3-D12 11-2L-D10@60 C/C 27-2L-D10@125 C/C 11-2L-D10@60 C/C

BEAM SCHEDULE (C21 : Fy414 (MAIN) : Fy276 (SHEAR)) (LEVEL: 4.5 m)

BEAM SIZE BOTTOM REINFORCEMENT TOP REINFORCEMENT SHEAR STIRRUPS

NUMBERS B D LEFT MID SPAN RIGHT LEFT MID SPAN RIGHT LEFT MID SPAN RIGHT
B1,B2,B3,B4 250 300 2-D12 2-D12 2-D12 2-D12 2-D12 2-D12 11-2L-D10@60 C/C 24-2L-D10@100 C/C 11-2L-D10@60 C/C

B5,B6,B7 250 300 2-D12 2-D12 2-D12 2-D12 2-D12 2-D12 11-2L-D10@60 C/C 27-2L-D10@125 C/C 11-2L-D10@60 C/C

S4 ROOF BEAM SECTION DETAILS


SCALE: NTS
B
CIVIL ENGINEER CLIENT SHEET CONTENT REVISIONS SHEET NO.
DRAWINGS AS INSTRUMENTS OF SERVICE GROUND AND ROOF FRAMING
ARE THE PROPERTY OF THE COMPANY AND HAROLD LAENON L. BINDADAN MR. ENGELBERT VINOYA & MRS. MARY GYPSY VINOYA ST00 - 3.0.0
PLANS
SUCH MUST NOT BE REPRODUCED OR
COPIED IN PART OR IN WHOLE WITHOUT PTR NO : REG NO : PROJECT LOCATION PROJECT MILESTONE
THE WRITTEN PERMISSION. OF THE 7650324 145691
ISSUED ON : ISSUED AT :
ONE STOREY COMMERCIAL BUILDING TURAC, SAN CARLOS CITY, FOR PERMIT
ARCHITECT / ENGINEER.
01/11/2023 TUBA, BENGUET PANGASINAN