Storage Area 6 X 8 M: Cold Aisle Hot Aisle Hot Aisle Hot Aisle

The document describes a data center layout. It includes various equipment like servers, racks, power distribution units, and cooling systems in different aisles. The diagram labels multiple pieces of equipment and their locations within the data center infrastructure.

Uploaded by

ptapmc09
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views1 page

Storage Area 6 X 8 M: Cold Aisle Hot Aisle Hot Aisle Hot Aisle

The document describes a data center layout. It includes various equipment like servers, racks, power distribution units, and cooling systems in different aisles. The diagram labels multiple pieces of equipment and their locations within the data center infrastructure.

Uploaded by

ptapmc09
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

6100 6100

5874
ALMIRAH

Fire Cylinder
COLD AISLE HOT AISLE

DCDB
HOT AISLE 7100 R4

AC
KRONE

14
NLD-33 TR-1 TR-2 TR-3 TR-4 TR-5 7100 R4 7100 R1 7100 R2 7100 R3

DCDB
COLD AISLE HOT AISLE COLD AISLE

AC
TR-6 TR-7 TR-8 TR-9 TR-10 NLD VMGW GMGW MGW
PDU-1

DCDB

13

5966
COLD AISLE
PROPOSED PROPOSED

DCDB
7635

AC
CLOUD CLOUD
STORAGE AREA LAN

12
EPDU EPDU EPDU TELE
RNC-2
SWITCH NEW UNIFIED TELE
100 98 97 UNIFIED
ARNC-2 LBS CLOUD PHONY PHONY
EPDU EPDU EPDU CLOUD
TX
6x8M 91 90 92 RACK RACK 1 RACK 2
DCDB

AC
11
COLD AISLE
RACK RACK
EPDU EPDU
RNC4
SE MCPA SSNC SSNC
EPDU MSRNC/
96 99

EXIT
94
EPDU EPDU
93 95
HOT AISLE
DCDB

DCN SWAP SISCO 2921


2.4KW LOAD
WILL BE ADDED
2.4KW LOAD CISCO 7606
WILL BE ADDED

ORACLE

1000
IPMPLS IPMPLS IPMPLS
IPMPLS RACK
DCDB

IPMPLS RACK 4 RACK 3 RACK 2


CEN CEN RACK 1
RACK 5
NLD 34 NLD 35 1 2

600
COLD AISLE
DCDB

1200
4249 1510

AC
Akamai rack will be
POWER

10
installed after

6234
PROPOSED PROPOSED Removing ETOP2 OFF

MSS RNC-10
DCDB

PAC-1 MGW
10Tr. WAP CGF ETOP
ORACLE GATE LBS server UBONA ETOP ETOP
STORAGE

AC
RACK 2 1
WAY

9
COLD AISLE COLD AISLE
PROPOSED
6566

PROPOSED

AC
RNC6 PDU PDU PDU PDU EPDU EPDU
Ericsson RACK RACK
GMSC

8
2A1
POWER MSS 2B2 2A2 2B1
800

800

800
ROOM COLD AISLE

24000
PROPOSED PROPOSED

4x6M MPBN-2 MPBN-1 GMGW-2 GMGW-1 VMSC-1 MGW-2 GMGW-


DR
BC-1 MGW-3 VMGW-4 BC-2
MGW
GMGW
SWITCH ROOM
10390

AC
12 x COLD
24 M AISLE
800

800

7
HOT AISLE
PROPOSED
PAC-1
10Tr. NLD 7 NLD 6
MX480 HIQR VMGW4 HIQR HIQR HIQR NLD NLD NLD
1000

600

600

10 9 8
PROPOSED

LOBBY ODF ODF

AC
WASHROOM

6100
COLD AISLE
HOT AISLE 6
600

STP

4X4M 2 x 10 M
CP113E MCPA MB/CCG
MCPA MB/CCG SSNC SSNC CP113E
AC

HOT AISLE
5

PROPOSED

MSBSC MSBSC MSBSC MC C-RNC1 HSS PDU 1B2 DCDB1DCDB2


1 1 1 RNC2
DELTA DELTA

D3
900

D3 COLD AISLE
COLD AISLE

4 5
AC

RACK
KOL-VAG KOL-VAG
1 HSS GEOPROBE
VGC
4

HLR HIQR
ATCA HIQR 01 A00 00 A00
1715

PROPOSED ADDITION
935

2800 WATT 720W.EXTRA 720W.EXTRA


LOAD WILL LOAD ADDITION
EXTRA LOAD WILL BE ADDED
LOAD ADDITION
BE ADDED IN NEW LOAD (538.5W) IN EXITING IN EXITING
1.2KW LOAD
RECC RECC WILL BE EXPANSION RECC RACK 04 RECC RACK 05 UGE-1 1 KW
KOLKATA ACTIVE RECC KOLKATA
RATER RACK 1 ACTIVE RACK-2

HOT AISLE
AC

2250 RECC RECC RECC RECC RECC


3

RECC
KOLKATA KOLKATA KOLKATA KOLKATA KOLKATAKOLKATA
ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE RTSP Rack MCARBON RSTP
G14 RNC
1750 RATER RATER RATER RATER RATER RATER PROBE

SHAFT RACK 1 RACK 2 RACK 3 RACK 4 RACK 5 RACK 6


RACK CISCO
RACK
2230

6100
AC

2X2M
2

COLD AISLE
1300

COLD AISLE
3.2 3.2 3.2 3.2 3.2
AC

RACK 8 RACK 7 Rack-2 OCS OCS OCS OCS OCS


RACK 7 RACK 8 1 2 3
1

RATER RATER CMD/L RATER RATER 4 5


Active Storage DR Rack- DR Rack- DR Rack- DR Rack- DR Rack-
DR DR ACTIVE
1800

850
ACTIVE Chennei Chennei Chennei Chennei Chennei
Kolkata DR
UP
Chennei Chennei KOLKATA
RECC Kolkata KOLKATA RECC RECC RECC RECC RECC
RECC RECC RECC RECC

12000 HOT AISLE


930

HOT AISLE
NEW LOAD (807.8W)
NEW LOAD (538.5W)
WILL BE EXPANSION
WILL BE EXPANSION
RECC CHENNAI WILL BE IN THIS TWO RACK
RECC CHENNAI
DC RACK-8
DC RACK-7 RECC NEW LOAD EXPANSION

You might also like