SENSORS
VEK S4 / VEK S4C
4 CHANNEL LOOP DETECTOR FOR ACQUISITION
OF VEHICLE SPEED AND VEHICLE CLASS
– Detection of vehicle speed, vehicle length, classification
of vehicles with a double loop system
– Classification of vehicles and data transfer according
to the TLS-guidelines in 8 + 1 classes accuracy class 2
– Detection of vehicles in both directions
– 4 open collector outputs with selectable function
– Available as detector in plastic housing
(direct installation on DIN rail) or as 19“ board
– High reliability, extreme high MTBF rate
FEIG Induction Loop Detectors for traffic counting Additional features:
and management
› Communication via RS485 or CAN interface
A generally increasing volume of traffic, dynamic traffic flows
› Advanced settings with S4 COM software tool
and particularly enormously increasing peak loads on the
roads are the challenges for an optimally controlled flow of › High speed open-collector outputs
traffic.
› Automatic system adjustment directly after power on
The FEIG 4-channel traffic detectors VEK S4 are specially
› Galvanic isolation between loop and detector electronics
designed for use in traffic management systems and reliably
collect all the relevant vehicle data for a full evaluation: › Sensitivity adjustment independent of loop inductivity
speed, length, classification into 8 + 1 vehicle categories,
› Continuous readjustment of frequency drifts in order to
gap time intervals and loop status.
avoid environmental influences
FEIG also provides a settings and diagnostics program free of
› Quick response time
charge via RS485. All FEIG detectors are certified by the Federal
Highway Research Institute (BASt). › Power, com and synchronization of multiple VEK S4
detectors via flat ribbon cable
Technical Data VEK S4 VEK S4C
Housing Polyamide PA 6.6, blue | 19” board, 3HE / 5TE
Dimensions (w x h x d) 22.5 mm x 99 mm x 114.5 mm | 100 mm x 600 mm
Weight 165 g | 150 g
Type of protection IP 30 | –
Supply voltage 12 – 24 V DC +/-20 % (SELV according to EN60950-1)
Power consumption typ. 0.9 W / max. 1.2 W typ. 0.9 W / max. 1.6 W
Temperature range Operation -20 °C up to 70 °C; Storage -40 °C up to 85 °C
Terminals Plug-in terminals 4-pin | Male connector DIN 41612
0.2 – 2.5 mm 2 (AWG 24 – 14) | Design B
VEK S4
Front ribbon cable 10-pin IDC plug | 14-pin IDC plug
RS485 VEK S4 protocol (option: SiTOS)
VEK S3 protocol and VEK S3 TLS protocol
2400, 4800, 9600, 19200, 38400 Baud
CAN CANopen, communication profile CiA DS-301
100, 125, 250, 500, 800, 1000 kBits/s
Device address DIP switch 4 Bit (+ Adr.-Offset) | DIP switch 4 Bit (+ Adr.-Offset)
or via male connector 5 Bit
Loop Characteristics
Loop channels 4 (multiplexing, 2 ms cycle per channel)
VEK S4C
Loop supply cable up to 300 m
Inductance range 25 – 1200 μH (recommended 80 – 300 μH)
Operating frequency 30 – 140 kHz (5 frequency bands)
Loop resistance max. 25 Ω (including loop supply line)
Loop inputs galvanic separation (1 kV), 90 V gas arrester to ground contact
Loop geometry max. head space 650 cm, max. loop length 400 cm
(recommended TLS loop type 2)
Classification
Lanes 2, both directions
Vehicle classes 8 + 1 classes according to TLS guidelines 2012, BASt certificated
(Motor cycle, car, car + trailer, lorry, truck, truck + trailer, bus,
semitrailer, other vehicles with lane changer)
Vehicle length 10 – 255 dm, tolerance +/-3 dm
Vehicle speed 10 – 255 km/h, tolerance +/-3 km/h < 100 km/h,+/-3 % > 100 km/h
Further vehicle data Net time gap, occupation time, jam recognition,
vehicle counter in RAM, option: axis information
TLS classification accuracy A2
Order Descpriptions
5044 VEK S4 4-channel induction loop detector
5054 VEK S4C 4-channel induction loop detector, 19” plug-in board 3HE / 5TE
FEIG ELECTRONIC GmbH Information updated: Mai 2020. The information in this document is subject to change
without prior notice and is not to be considered as a warranted characteristic.
35781 Weilburg, Germany, [email protected], www.feig.de All brand names, trademarks or logos are the property of their respective owners.