0% found this document useful (0 votes)
115 views2 pages

Data Sheet Sensors VEK S4 S4C

The document discusses FEIG Induction Loop Detectors for traffic counting and management. The VEK S4 and VEK S4C are 4-channel loop detectors that detect vehicle speed, length, and classify vehicles into 8+1 categories. They reliably collect vehicle data for traffic management systems and evaluation.

Uploaded by

badeaioana70
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
115 views2 pages

Data Sheet Sensors VEK S4 S4C

The document discusses FEIG Induction Loop Detectors for traffic counting and management. The VEK S4 and VEK S4C are 4-channel loop detectors that detect vehicle speed, length, and classify vehicles into 8+1 categories. They reliably collect vehicle data for traffic management systems and evaluation.

Uploaded by

badeaioana70
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

SENSORS

VEK S4 / VEK S4C

4 CHANNEL LOOP DETECTOR FOR ACQUISITION


OF VEHICLE SPEED AND VEHICLE CLASS
– Detection of vehicle speed, vehicle length, classification
of vehicles with a double loop system
– Classification of vehicles and data transfer according
to the TLS-guidelines in 8 + 1 classes accuracy class 2
– Detection of vehicles in both directions
– 4 open collector outputs with selectable function
– Available as detector in plastic housing
(direct installation on DIN rail) or as 19“ board
– High reliability, extreme high MTBF rate

FEIG Induction Loop Detectors for traffic counting Additional features:


and management
› Communication via RS485 or CAN interface
A generally increasing volume of traffic, dynamic traffic flows
› Advanced settings with S4 COM software tool
and particularly enormously increasing peak loads on the
roads are the challenges for an optimally controlled flow of › High speed open-collector outputs
traffic.
› Automatic system adjustment directly after power on
The FEIG 4-channel traffic detectors VEK S4 are specially
› Galvanic isolation between loop and detector electronics
­designed for use in traffic management systems and reliably
collect all the relevant vehicle data for a full evaluation: › Sensitivity adjustment independent of loop inductivity
speed, length, classification into 8 + 1 vehicle categories,
› Continuous readjustment of frequency drifts in order to
gap time intervals and loop status.
avoid environmental influences
FEIG also provides a settings and diagnostics program free of
› Quick response time
charge via RS485. All FEIG detectors are certified by the Federal
Highway Research Institute (BASt). › Power, com and synchronization of multiple VEK S4
­detectors via flat ribbon cable
Technical Data VEK S4 VEK S4C

Housing Polyamide PA 6.6, blue | 19” board, 3HE / 5TE


Dimensions (w x h x d) 22.5 mm x 99 mm x 114.5 mm | 100 mm x 600 mm
Weight 165 g | 150 g
Type of protection IP 30 | –
Supply voltage 12 – 24 V DC +/-20 % (SELV according to EN60950-1)
Power consumption typ. 0.9 W / max. 1.2 W typ. 0.9 W / max. 1.6 W
Temperature range Operation -20 °C up to 70 °C; Storage -40 °C up to 85 °C
Terminals Plug-in terminals 4-pin | Male connector DIN 41612
0.2 – 2.5 mm 2 (AWG 24 – 14) | Design B
VEK S4
Front ribbon cable 10-pin IDC plug | 14-pin IDC plug
RS485 VEK S4 protocol (option: SiTOS)
VEK S3 protocol and VEK S3 TLS protocol
2400, 4800, 9600, 19200, 38400 Baud
CAN CANopen, communication profile CiA DS-301
100, 125, 250, 500, 800, 1000 kBits/s
Device address DIP switch 4 Bit (+ Adr.-Offset) | DIP switch 4 Bit (+ Adr.-Offset)
or via male connector 5 Bit

Loop Characteristics

Loop channels 4 (multiplexing, 2 ms cycle per channel)


VEK S4C
Loop supply cable up to 300 m
Inductance range 25 – 1200 μH (recommended 80 – 300 μH)
Operating frequency 30 – 140 kHz (5 frequency bands)
Loop resistance max. 25 Ω (including loop supply line)
Loop inputs galvanic separation (1 kV), 90 V gas arrester to ground contact
Loop geometry max. head space 650 cm, max. loop length 400 cm
(recommended TLS loop type 2)

Classification

Lanes 2, both directions


Vehicle classes 8 + 1 classes according to TLS guidelines 2012, BASt certificated
(Motor cycle, car, car + trailer, lorry, truck, truck + trailer, bus,
semitrailer, other vehicles with lane changer)
Vehicle length 10 – 255 dm, tolerance +/-3 dm
Vehicle speed 10 – 255 km/h, tolerance +/-3 km/h < 100 km/h,+/-3 % > 100 km/h
Further vehicle data Net time gap, occupation time, jam recognition,
vehicle counter in RAM, option: axis information
TLS classification accuracy A2

Order Descpriptions

5044 VEK S4 4-channel induction loop detector


5054 VEK S4C 4-channel induction loop detector, 19” plug-in board 3HE / 5TE

FEIG ELECTRONIC GmbH Information updated: Mai 2020. The information in this document is subject to change
without prior notice and is not to be considered as a warranted characteristic.
35781 Weilburg, Germany, [email protected], www.feig.de All brand names, trademarks or logos are the property of their respective owners.