3412 Aberto Fechado
3412 Aberto Fechado
3412 Aberto Fechado
**700 (875) **635 (793) *750 (937) *680 (850) Optimized for
*800 (1000) *725 (906) — — Low Fuel Consumption
Standard Features
Cat® Diesel Engine EMCP 4 Control Panels
• Designed and optimized for low fuel • User-friendly interface and navigation
consumption • Scalable system to meet a wide range of
• Reliable performance proven in thousands of installation requirements
applications worldwide • Expansion modules and site specific
programming for specific customer requirements
Generator Set Package
• Accepts 100% block load in one step and meets Warranty
NFPA 110 loading requirements • 24 months/1000-hour warranty for standby and
• Conforms to ISO 8528-5 G3 load mission critical ratings
acceptance requirements • 12 months/unlimited hour warranty for prime
• Reliability verified through torsional vibration, and continuous ratings
fuel consumption, oil consumption, transient • Extended service protection is available to
performance, and endurance testing provide extended coverage options
Alternators Worldwide Product Support
• Superior motor starting capability minimizes • Cat dealers have over 1,800 dealer branch
need for oversizing generator stores operating in 200 countries
• Designed to match performance and output • Your local Cat dealer provides extensive
characteristics of Cat diesel engines post-sale support, including maintenance and
repair agreements
Cooling System
• Cooling systems available to operate in ambient Financing
temperatures up to 49°C (120°F) • Caterpillar offers an array of financial products
• Tested to ensure proper generator set cooling to help you succeed through financial service
excellence
• Options include loans, finance lease,
operating lease, working capital, and revolving
line of credit
• Contact your local Cat dealer for availability in
your region
LEHE1468-02 Page 1 of 5
3412 Diesel Generator Sets
Electric Power
Optional Equipment
Engine Power Termination Vibration Isolators
Air Cleaner Type ❑ Spring
❑ Single element ❑ Bus bar
❑ Dual element ❑ Circuit breaker Cat Connect
❑ Heavy duty ❑ 1600A ❑ IEC Connectivity
❑ 2500A ❑ 3-pole Ethernet
Muffler
❑ UL ❑ 4-pole Cellular
❑ Industrial grade (10 dB) ❑ Manually operated
❑ Critical grade (35 dB) Satellite
❑ Electrically operated
Starting Trip Unit Extended Service Options
❑ Standard batteries ❑ LSI
❑ Oversized batteries Terms
❑ Heavy duty electric starter(s) ❑ 2 year (prime)
Factory Enclosure ❑ 3 year
❑ Dual electric starter(s)
❑ Jacket water heater ❑ Weather protective ❑ 5 year
❑ Sound attenuated ❑ 10 year
Alternator Coverage
Fuel Tank
Output voltage ❑ Silver
❑ 220V ❑ 440V ❑ 317 gal (1200 L) ❑ Gold
❑ 240V ❑ 480V ❑ Platinum
❑ 380V Control System ❑ Platinum Plus
Note: Some options may not be available on all models. Certifications may not be
available with all model configurations. Consult factory for availability.
LEHE1468-02 Page 2 of 5
3412 Diesel Generator Sets
Electric Power
Package Performance
Performance Standby Prime Standby Prime
Frequency 60 Hz 60 Hz 60 Hz 60 Hz
Gen set power rating with fan 700 ekW 635 ekW 750 ekW 680 ekW
Gen set power rating with fan @
875 kVA 793 kVA 937 kVA 850 kVA
0.8 power factor
Emissions Low Fuel Low Fuel Low Fuel Low Fuel
Performance number EM1156-01 EM1157-01 EM1162-01 EM1163-00
Fuel Consumption
100% load with fan – L/hr (gal/hr) 188.1 (42.0) 171.0 (45.2) 206.3 (54.5) 187.3 (49.5)
75% load with fan – L/hr (gal/hr) 144.5 (32.1) 133.0 (35.1) 156.0 (41.2) 142.7 (37.7)
50% load with fan – L/hr (gal/hr) 103.3 (22.5) 95.5 (25.2) 109.8 (29.0) 101.8 (26.9)
25% load with fan – L/hr (gal/hr) 62.9 (13.2) 59.0 (15.6) 66.2 (17.5) 62.0 (16.4)
Cooling System
Radiator air flow restriction (system) –
0.12 (0.48) 0.12 (0.48) 0.12 (0.48) 0.12 (0.48)
kPa (in. water)
Radiator air flow – m3/min (cfm) 923.0 (32595) 923.0 (32595) 923.0 (32595) 923.0 (32595)
Engine coolant capacity – L (gal) 58.6 (15.5) 58.6 (15.5) 58.6 (15.5) 58.6 (15.5)
Radiator coolant capacity – L (gal) 90.0 (23.8) 90.0 (23.8) 90.0 (23.8) 90.0 (23.8)
Total coolant capacity – L (gal) 148.8 (39.3) 148.8 (39.3) 148.8 (39.3) 148.8 (39.3)
Inlet Air
Combustion air inlet flow rate – m3/min (cfm) 52.2 (1843.3) 48.5 (1712.6) 65.2 (2302.4) 59.3 (2093.9)
Exhaust System
Exhaust stack gas temperature – °C (°F) 551.0 (1023.8) 542.5 (1008.5) 513.9 (957.0) 508.5 (947.3)
Exhaust gas flow rate – m3/min (cfm) 153.8 (5431.1) 141.1 (4982.5) 181.9 (6423.4) 164.3 (5801.5)
Exhaust system backpressure (maximum
6.7 (27.0) 6.7 (27.0) 6.7 (27.0) 6.7 (27.0)
allowable) – kPa (in. water)
Heat Rejection
Heat rejection to jacket water – kW (Btu/min) 434 (24682) 395 (22464) 474 (26957) 431 (24510)
Heat rejection to exhaust (total) – kW (Btu/min) 700 (39810) 637 (36227) 794 (45157) 715 (40661)
Heat rejection to aftercooler – kW (Btu/min) 71 (4061) 58 (3304) 130 (7394) 106 (6028)
Heat rejection to atmosphere from engine –
108 (6142) 94 (5334) 114 (6483) 104 (5914)
kW (Btu/min)
Heat rejection from alternator – kW (Btu/min) 31 (1746) 27 (1541) 28 (1592) 25 (1445)
Emissions (Nominal)
NOx mg/Nm3 (g/hp-h) 3936.3 (8.18) 4206.0 (8.71) 2827.4 (5.96) 2848.9 (5.97)
CO mg/Nm3 (g/hp-h) 321.6 (0.67) 307.1 (0.64) 334.2 (0.71) 313.8 (0.66)
HC mg/Nm (g/hp-h)
3
29.7 (0.06) 30.1 (0.06) 56.5 (0.13) 50.3 (0.12)
PM mg/Nm3 (g/hp-h) 45.2 (0.09) 40.0 (0.08) 42.4 (0.11) 39.7 (0.10)
Emissions (Potential Site Variation)
NOx mg/Nm3 (g/hp-h) 4762.9 (9.90) 5089.2 (10.54) 3421.1 (7.21) 3447.2 (7.22)
CO mg/Nm (g/hp-h)
3
601.4 (1.25) 574.3 (1.19) 625.0 (1.32) 586.8 (1.23)
HC mg/Nm3 (g/hp-h) 56.1 (0.12) 56.9 (0.12) 106.8 (0.25) 95.1 (0.22)
PM mg/Nm (g/hp-h)
3
88.2 (0.18) 78.0 (0.16) 82.7 (0.21) 77.4 (0.20)
LEHE1468-02 Page 3 of 5
3412 Diesel Generator Sets
Electric Power
Package Performance
Performance Standby Prime Standby Prime
Frequency 60 Hz 60 Hz — —
Gen set power rating with fan 800 ekW 725 ekW — —
Gen set power rating with fan @
1000 kVA 906 kVA — —
0.8 power factor
Emissions Low Fuel Low Fuel — —
Performance number EM1160-00 EM1161-01 —
Fuel Consumption
100% load with fan – L/hr (gal/hr) 221.9 (58.6) 198.8 (52.5) — —
75% load with fan – L/hr (gal/hr) 165.6 (43.8) 150.6 (39.8) — —
50% load with fan – L/hr (gal/hr) 115.7 (30.6) 106.5 (28.1) — —
25% load with fan – L/hr (gal/hr) 69.4 (18.3) 64.1 (16.9) — —
Cooling System
Radiator air flow restriction (system) –
0.12 (0.48) 0.12 (0.48) — —
kPa (in. water)
Radiator air flow – m3/min (cfm) 923.0 (32595) 923.0 (32595) — —
Engine coolant capacity – L (gal) 58.6 (15.5) 58.6 (15.5) — —
Radiator coolant capacity – L (gal) 90.0 (23.8) 90.0 (23.8) — —
Total coolant capacity – L (gal) 148.8 (39.3) 148.8 (39.3) — —
Inlet Air
Combustion air inlet flow rate – m3/min (cfm) 69.6 (2457.6) 63.0 (2224.5) — —
Exhaust System
Exhaust stack gas temperature – °C (°F) 517.8 (964.0) 539.4 (1002.9) — —
Exhaust gas flow rate – m3/min (cfm) 195.1 (6889.2) 139.1 (4913.4) — —
Exhaust system backpressure (maximum
6.7 (27.0) 6.7 (27.0) — —
allowable) – kPa (in. water)
Heat Rejection
Heat rejection to jacket water – kW (Btu/min) 508 (28890) 457 (25988) — —
Heat rejection to exhaust (total) – kW (Btu/min) 855 (48624) 764 (43445) — —
Heat rejection to aftercooler – kW (Btu/min) 147 (8360) 122 (6937) — —
Heat rejection to atmosphere from engine –
131 (7450) 108 (6142) — —
kW (Btu/min)
Heat rejection from alternator – kW (Btu/min) 31 (1746) 27 (1541) — —
Emissions (Nominal)
NOx mg/Nm3 (g/hp-h) 2793.2 (5.95) 2837.2 (5.96) — —
CO mg/Nm3 (g/hp-h) 400.2 (0.85) 317.9 (0.67) — —
HC mg/Nm (g/hp-h)
3
59.2 (0.14) 54.4 (0.13) — —
PM mg/Nm3 (g/hp-h) 53.1 (0.14) 40.0 (0.10) — —
Emissions (Potential Site Variation)
NOx mg/Nm3 (g/hp-h) 3379.8 (7.20) 3433.1 (7.21) — —
CO mg/Nm (g/hp-h)
3
748.4 (1.59) 594.5 (1.25) — —
HC mg/Nm3 (g/hp-h) 111.9 (0.26) 102.8 (0.24) — —
PM mg/Nm (g/hp-h)
3
103.5 (0.27) 78.0 (0.20) — —
LEHE1468-02 Page 4 of 5
3412 Diesel Generator Sets
Electric Power
A B
Standby Prime Standby Prime Dim “A” Dim “B” Dim “C” Dry Weight
60 Hz ekW (kVA) 60 Hz ekW (kVA) 60 Hz ekW (kVA) 60 Hz ekW (kVA) mm (in) mm (in) mm (in) kg (lb)
700 (875) 635 (793) — — 4125 (162.4) 1989 (78.3) 1906 (75) 5761 (12,700)
750 (937) 680 (850) 800 (1000) 725 (906) 4125 (162.4) 1989 (78.3) 1906 (75) 6021 (13,275)
Note: For reference only. Do not use for installation design. Contact your local Cat dealer for precise weights and dimensions.
Ratings Definitions
Standby Applicable Codes and Standards
Output available with varying load for the duration of AS1359, CSA C22.2 No100-04, UL142, UL489, UL869,
the interruption of the normal source power. Average UL2200, NFPA37, NFPA70, NFPA99, NFPA110, IBC,
power output is 70% of the standby power rating. Typical IEC60034-1, ISO 3046, ISO 8528, NEMA MG1-22,
operation is 200 hours per year, with maximum expected NEMA MG1-33, 2014/35/EU, 2006/42/EC, 2014/30/EU.
usage of 500 hours per year. Note: Codes may not be available in all model
Prime configurations. Please consult your local Cat dealer for
Output available with varying load for an unlimited time. availability.
Average power output is 70% of the prime power rating. Data Center Applications
Typical peak demand is 100% of prime rated ekW Tier III/Tier IV compliant per Uptime Institute
with 10% overload capability for emergency use for a requirements. ANSI/TIA-942 compliant for Rated-1
maximum of 1 hour in 12. Overload operation cannot through Rated-4 data centers.
exceed 25 hours per year.
Fuel Rates
Fuel rates are based on fuel oil of 35º API [16°C (60ºF)]
gravity having an LHV of 42,780 kJ/kg (18,390 Btu/lb)
when used at 29ºC (85ºF) and weighing 838.9 g/liter
(7.001 lbs/U.S. gal.)
www.cat.com/electricpower
©2019 Caterpillar
All rights reserved.
Materials and specifications are subject to change without notice.
The International System of Units (SI) is used in this publication.
CAT, CATERPILLAR, LET'S DO THE WORK, their respective logos, “Caterpillar Yellow”,
3412 PGDI the “Power Edge” and Cat “Modern Hex” trade dress as well as corporate and product
LEHE1468-02 (05-19) identity used herein, are trademarks of Caterpillar and may not be used without permission.
Enclosures
Sound Attenuated /
Weather Protective
Enclosures for
3412C Powered Generator Sets
Larne 50 / 60 Hz
These factory installed enclosures include
installed silencers, and are designed for safety
and aesthetic value. The enclosure is mounted
on either an integral fuel tank base or a wide
fabricated steel base. Rugged construction
provides weather protection and a high degree of
sound reduction.
Picture shown may not reflect actual configuration
Features
Robust / Highly Corrosion Security and Safety
Resistant Construction ● Lockable access doors with standard key
● Environmentally friendly, polyester powder ● Cooling fan and battery charging alternator
baked paint in Caterpillar yellow or white fully guarded
● Zinc plated or stainless steel fasteners ● Externally mounted emergency stop button
● 4 Gauge steel construction ● Designed for spreader-bar lifting to
● Internally mounted exhaust silencing system ensure safety
● Control panel viewing window
Excellent Access
Options
● Control panel mounted on right side
of package ● Interior lighting system
● Large cable entry area for ease of installation ● 1200L (317 Gal) integral fuel tank in base
● Accommodates right side entry access to
power terminal strips or circuit breaker
● Multiple doors on both sides allow easy access
to service points
● Hinged doors allow 180° opening rotation
● Lube oil and coolant drains piped to exterior of
enclosure and terminated with drain valves
● Radiator fill cover
LEHX9088-04 Page 1 of 2
Enclosure Dimensions
Sound Attenuated Weather Protective
Dimensions:
Length — mm (inch) 5900 (232) 5260 (207)
Height w/base — mm (inch) 2564 (101) 2564 (101)
Width w/base — mm (inch) 2238 (88) 2238 (88)
Approximate Weight of Package:
kg (lb) 9270 (20,394) 8812 (19,430)
For reference only. Do not use for installation design. Please contact your local dealer for exact weights and dimensions.
Information contained in this publication may be considered confidential. Discretion is recommended when distributing.
Materials and specifications are subject to change without notice.
CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Yellow,” the “Power Edge” and Cat “Modern Hex”
trade dress as well as corporate and product identity used herein, are trademarks
of Caterpillar and may not be used without permission.
www.cat,com/electricpower
©2019 Caterpillar
LEHX9088-04 (03/19) All rights reserved.