Schletter-Product Sheets-Ground Mounted Systems-FS Duo
Schletter-Product Sheets-Ground Mounted Systems-FS Duo
Schletter-Product Sheets-Ground Mounted Systems-FS Duo
EN
FS DUO
PRODUCT SHEET
A geological survey of the subsoil and 3D terrain Optimal system stability under wind and snow loads
analysis on site form part of the detailed and is ensured through the selection of galvanised posts
individual project planning process. from a variety of size classes. The pile-driven posts we
develop ensure excellent integration with the ground
Load testing on the driven piles and chemical while maintaining maximum rigidity against bending.
analyses determine the load bearing capacity When necessary, hybrid solutions are also offered.
of the soil to create a soil profile.
The system takes into account all international
standards and can withstand any wind and snow loads
on site through the optimised design.
TECHNICAL DETAILS
Scope of application • Open area system with two pile-driven post foundation supports
Material • Posts: Steel, Z1200 hot-dip galvanized in accordance with DIN EN ISO 1461 or ZM600
coated in accordance with DIN EN 10346 (depending on soil conditions)
• Purlins/trusses: Steel, Z600 hot-dip galvanized in accordance with DIN EN ISO
12944-2 or ZM310 coated in accordance with DIN EN 10346
• Module clamps: Aluminium clamps or screw connections according to customer
requirements
• Fasteners and screws: Zinc flake coated steel or stainless steel
• Project-specific adjustments are possible, based on region and according to local
standards
Structural design • Individual system calculations based on regional data and guidelines
• Structural analysis of the terrain based on an external soil survey
• 3D terrain model for foundation design and optimisation (optional)
• The load assumptions correspond to DIN EN 1991-1 Parts 3 and 4, DIN EN 1990, DIN
EN 1999, DIN EN 1993 the regulations of the national annex (UL 2703, ASCE 07-05,
ASCE 07-10, ASCE 07-16, ASCE 07-20)
• In-house calculations according to 50 different worldwide standards (Eurocode, US
Code, IS, SANS, Australian Standard) with our own globally valid structural analysis
software
• Verification of all structural components based on FEM calculations or according to
an empirical test setup (wind tunnel tests)
Module mounting • Module fastening from above with Rapid clamps (adaptable to any module type)
• Module fastening from below with screws (adaptable to any module type)
• Integrated grounding of the modules (optional)