2-Latest EIC-C-1002-0 (Pilot Operated Relief Valve)
2-Latest EIC-C-1002-0 (Pilot Operated Relief Valve)
2-Latest EIC-C-1002-0 (Pilot Operated Relief Valve)
EIC-C-1002-0
■ Pilot Operated Relief Valves
These valves protect the hydraulic system from excessive
pressure, and can be used to maintain constant pressure in
a hydraulic system.
Remote control and unloading are permitted by vent circuit.
Graphic Symbol
Vent Connection C
Use high venting pressure type to reduce the response time from unload to onload.
■ Attachment
Mounting Bolts
Valve Qty Bolt Kit
Socket Head Cap Screw
Model Number Nos. Ordering Code
BG-03 M12 x 70Lg., M12 x 95Lg. 2 each BK BG-03-10
BG-06 M16 x 60Lg., M16 x 80Lg. 2 each BK BG-06-10
BG-10 M20 x 70Lg., M20 x 90Lg. 2 each BK BG-10-10
■ Sub-Plate
Valve Sub-plate Piping Mass
Model Number Model Number Size Kg.
BGM-03-3080 3/8 BSP.F 2.4
BG-03
BGM-03X-3080 1/2 BSP.F 3.1
BGM-06-3080 3/4 BSP.F 4.7
BG-06
BGM-06X-3080 1 BSP.F 5.7
BGM-10-3080 1-1/4 BSP.F 8.4
BG-10
BGM-10X-3080 1-1/2 BSP.F 10.3
Sub-plates are available. Specify sub-plate model from the table above. When sub-plates are not used, the mounting
surface should have a good machined finish.
■ Instructions
If a remote control relief valve is used in the vent circuit, see page 1 in EIC-C-1001-0. In addition, if the
internal volume of the vent line is too large, chattering is likely to occur. Thus, as far as possible reduce
the inside Dia. and the length of the pipe.
To adjust the pressure, loosen the lock nut and turn the handle slowly clockwise for higher pressure or
anti-clockwise for lower pressures. One revolution of the handle makes about a 50 Kgf/cm2 pressure
change. After adjustments, do not forget to tighten the lock nut.
Pressure is limited by collars fitted. If a working pressure cannot be attained, remove some collars.
One collar is equivalent to 100 Kgf/cm2.
Piping of the Tank line should not be connected to any tank line of the other valves, but connected
directly to the tank.
With a small flow, the setting pressure may be unstable. Use models numbered 03 and 06 with a
flow rate 8 L/min. and model 10 with 15 L/min.
There are two threaded connection pressure ports. They can be connected each other in-line one
as inlet and the other as an outlet or the valve can be used by plugging one of the pressure ports.
2
Pilot Operated Relief Valves
PRESSURE CONTROLS
Model
45 Dia.
Vent Port 5 B C G H J K L N
Number
"S" Thd. Fully Extended
BT-06 68.5 62 36 52 90 45
C
D
Pressure Port P
J
"Q" Thd.
G
2 Places
T
Pressure Gauge N
E Connection L
"T" Thd.
M o u n ti n g S ur f ace
03 B G- 0 3 : I S O 6 2 6 4 AR - 0 6 - 2 - A
BG-06 P- 32 B G- 0 3 : I S O 6 2 6 4 A S - 0 8 - 2 - A
10 B G - 0 3 : I SO 6 2 6 4 A T - 1 0 - 2 - A
Model
H J K L
Number
Mounting Surface BG-03 14.1 41 82 117
(O-Ring Furnished) Lock Nut 14 Hex. BG-06 17 52 104 141
Two Collars BG-10 20.7 62 124 175
"A" SQ.
Model
N P Q S
Number
BG-03 77 22 13.5 21
Pressure Adjustment Handle BG-06 83.5 4.5 17.5 26
(Selectable in Other 2 Position) BG-10 110 6 124 175
In case of BG-03,
B C no spotface are
Fully Extended Vent Port made at those two
45 Dia.
holes.
Locating Pin
P
6 Dia.
G
Pressure Gauge
L
Connection
1 BSP.T Thd.
N
6 4
Pressure Port
D H "Q" Dia. x Thru.
E J "S" Dia. Spotface
F Tank Port K 4 Places
6.2 Dia.
N
L
S
U
K
V
G
P
J
T
Q
"a" Dia.
2 Places
"f" Thd.
7 Dia. x 10 Deep
2 Places
Model Numbers A B C D E F G H J K L N P Q
BGM-03 86 26
86 60 13 53.8 3.1 26.9 149 13 123 32 97 53.8
BGM-03X 95 21
BGM-06 106.5 27.2
108 78 15 70 4 35 180 15 150 51 121 66.7
BGM-06X 119 18
BGM-10 138.2 30.2
126 94 16 82.6 5.7 41.3 227 16 195 62 154 88.9
BGM-10X 158 17
Model Numbers S T U V X Y Z a b d
BGM-03 32
19 47.4 0 22 22 20 14.5 11 17.5
BGM-03X 40
BGM-06 40
37 55.5 23.8 33.4 11 25 23 13.5 21
BGM-06X 50
BGM-10 50
42 76.2 31.8 44.5 12.7 32 28 17.5 26
BGM-10X 63
4
Pilot Operated Relief Valves
PRESSURE CONTROLS
Pressure
Pressure
160 160
150 150
140 140
16 19
13 16
10 13
Kgf/cm²
BG-10 C
160
150
140
20
16
12
6 12
High Venting
Pressure
Pressure
5 10 Pressure Type
4 8
3 6
Low Venting
2 Pressure Type
4
High Venting Low Venting
1 Pressure Type 2 Pressure Type
0 0
0 25 50 75 100 L/min. 0 50 100 150 200 L/min.
Flow Rate Flow Rate
BG-10
Vent Pressure
Kgf/cm² Min. Adjustment Pressure
6
High Venting
4 Pressure Type
2
0
Pressure
8
6
4
Low Venting
2 Pressure Type
0
0 100 200 300 400 L/min.
Flow Rate
6
Pilot Operated Relief Valves
PRESSURE CONTROLS
Solenoid Controlled
Relief valves
■ Specifications
Model Number Max. Operating Pres. Adj. Mass (Kg)
Max. Flow
Threaded Sub-Plate Pressure Range Double Single With Vent
L/min.
Connection Mounting Kgf/cm2 Kgf/cm2 Solenoid Solenoid Restrictor
BST-06-※-※-※-※-4680 - 200 7.4 6.8 7.8
- BSG-03-※-※-※-※-46 (Note) 100 7.1 6.5 7.5
250
- BSG-06-※-※-※-※-46 *~250 200 8.0 7.4 8.4
- BSG-10-※-※-※-※-46 400 11.3 10.7 11.7
Note: For Relief Valves, standard pilot operated relief valves are used.
* For minimum adjustment pressure and other characteristics, see page 5.
N:
T: AC: With Plug-in
F: V: *3
Threaded 06 2B3A *4 connector
Special *1 BS: *2 A120
A: Connection For High (DIN)
Seals for Solenoid 2B3B
Phosphate With Controlled Venting A240
2B2B 46 80
Ester Type Vent Relief Pressure
2B2 N1:
Fluids Restrictor Valves 03 Feature DC:
(Option) G: (Omit if not 3C2 With Plug-in
(Omit if not
Sub-Plate 06 required) 3C3 connector
required) D12,D24
Mounting with indicator
10 light (option)
*1 Models with vent restrictor are applicable only for the vent type 2B3A and 2B3B For details see page 9.
*2 Use high venting pressure types to reduce response time from unloading to onloading.
*3 For the details of the vent types, see the following page.
*4 The coil codes are the same as for solenoid directional valves DSG-01. See solenoid Rating on EIC-E-1001-0.
■ Vent type
Solenoid Operated Operation
Vent Type
Graphic Symbols Directional Valve
Model Number SOL “a” SOL “b” Vent Connecting
"A"
b
OFF Connected to “A” port
2B3A DSG-01-2B3A --
ON Connected to tank (no-load)
"B"
b
OFF Connected to tank (no-load)
2B3B DSG-01-2B3B --
ON Connected to “B” port
"B"
b Closed State (relief valve
OFF
Setting pressure)
2B2B DSG-01-2B2B --
ON Connected to “B” port
"A" "B"
b
OFF Connected to “A” port
2B2 DSG-01-2B2 --
ON Connected to “B” port
"A" "B"
Closed State (relief valve
a b OFF OFF
Setting pressure)
3C2 DSG-01-3C2 ON OFF Connected to “A” port
"A" "B"
a b OFF OFF Connected to tank (no-load)
8
Solenoid Controlled Relief Valves
PRESSURE CONTROLS
■ Attachment
Mounting Bolts
Valve Bolt Kit
Socket Head Cap Screw Qty.
Model Number Ordering Code
BSG-03 M12 x 70Lg., M12 x 95Lg. 2 each BKBG - 03 - 30
BSG-06 M16 x 60Lg., M16 x 80Lg. 2 each BKBG - 06 30
BSG-10 M20 x 70Lg., M20 x 90Lg. 2 each BKBG - 10 - 30
■ Sub-Plate
Valve Sub-Plate Piping Mass
Model Number Model Number Size Kg.
BGM-03-3080 3/8 BSP.F 2.4
BSG-03
BGM-03X-3080 1/2 BSP.F 3.1
BGM-06-3080 3/4 BSP.F 4.7
BSG-06
BGM-06X-3080 1 BSP.F 5.7 C
BGM-10-3080 1-1/4 BSP.F 8.4
BSG-10
BGM-10X-3080 1-1/2 BSP.F 10.3
Solenoid Controlled
Sub-plates are available. Specify sub-plate model from the table above. When sub-plates are not
Relief valves
used, the mounting surface should have a good machined finish.
The sub-plates are those for pilot operated relief valves . For dimensions, refer page 4.
■ Option
With vent restrictor
The type with a vent restrictor valve, in vent types 2B3A and 2B3B added between relief valve and a
solenoid operated directional valve. It prevents shock to the main circuit by gradually lowering the venting
pressure in the shift from set pressure to unloading.
Unloading pressures are the same as without a vent restrictor.
A-BS ※-※-2B3A A-BS ※-※-2B3B
b b
■ Instructions
The remote control relief valve is used in the vent circuit, see page 1 in EIC-C-1001. In addition, if
the internal volume of the vent line is too large, chattering is likely to occur. Thus, as far as
possible reduce the inside diameter and the length of the pipe.
To adjust the pressure, loosen the lock nut and turn the handle slowly clockwise for higher pressure
or anti-clockwise for lower pressures. One revolution of the handle makes about a
50 Kgf/cm2 pressure change. After adjustments, do not forget to tighten the lock nut.
Pressure is limited by collars fitted. If a working pressure cannot be attained, remove some collars.
one collar is equivalent to 100 Kgf/cm2.
Piping of the tank line should not be connected to any tank line of the other valves, but connected
directly to the tank.
With a small flow, the setting pressure may be unstable. Use models numbered 03 and 06 with a
flow rate above 8 L/min. and model 10 with 15 L/min.
There are two threaded connection pressure ports in BST type. They can be connected each other
in-line; one as inlet and the other as an outlet or the valve can be used by plugging one of the
pressure ports.
Solenoid Controlled Relief Valves 9
PRESSURE CONTROLS
h
i
Sol a Sol b
Model
U
Number
BSG-03, -N- 85
4680 Design
U
BSG-06, -N- 102.5
Remote Only
BSG-10, -N- 110
Control Port
"B"
1 BSP.F Thd.
8
105
Number
ee ff ee ff
A-BSG-03 115 77 245 180 256 191
d
ee
10
Solenoid Controlled Relief Valves
PRESSURE CONTROLS
Model Number T
※※※
f
107
e
BST-06- - - -N-
Model Number e f h
C
BST-※-※- 53 65 39
Solenoid Controlled
4680 Design Only (with AC solenoid)
T
BST-※-※-D-※-N-
Remote
Relief valves
Control Port "B" 64 76 39
1 BSP.F Thd.
8
(with DC solenoid)
Vent Port
3
8 BSP.Tr Thd.
Remote Control Port "A"
(Rear side) 1 BSP.F Thd.
8
Pressure Port
3
4 BSP.F Thd. Pressure Gauge Connection
2 Places 1 BSP.Tr Thd.
4
2B3A
A-BST-06- - - -4680
2B3B
105
zz
Graphic Symbols
Vent Connection
■ Specifications
Max. Operating
Pres. Adj. Range Max. Flow Mass (Approx)
Model Numbers Pressure
Kgf/cm2 L/min. Kg.
Kgf/cm2
※
YBG-03-P- -10
250 (3555) 60 2.7
* ~ 250
YBG-03-P-※-10H50
* Refer to ̒ ̒ Minimum Adjustment Pressure ̓ ̓ charecteristics on page 5.
■ Attachment
Mounting Bolts
Socket Head Cap
Model Number Qty. Bolt Kit Ordering Code
Screw
YBG-03-P- -10※ M12 x 55Lg. 4 BK-YBG-03-P- -10※
■ Sub-plate
Valve Model Sub-plate Model Mass (Approx)
Thread Size
Numbers Number Kg.
※
YBG-03-P- -10
BGM-03-3080 3/8 BSP.F 2.4
YBG-03-P-※-10H50
YBG-03-P-※-10
BGM-03-X-3080 3/8 BSP.F 2.4
YBG-03-P-※-10H50
Sub-plates are available. Specify sub-plate model from the table above. when sub-plates are not used, the mounting
surface should have a good machined finish.
■ Instructions
If the internal volume of the vent line is too large, chattering is likely to occur. Thus, as far as possible reduce the
inside dia.and lenth of the pipe
To adjust the pressure, loosen the lock nut and turn the handle slowely clockwise for higher pressure or
anti-clockwise for lower pressure. One revolution of the handle makes about a 50Kg/cm² pressure change. After
adjustment, do not forget to tighten the lock nut.
Piping of the tank line should not be connect to tank line of the other valves, but connect directly to tank.
With a small flow, the setting pressure may be unstable.
There are two threaded connection pressure ports. They can be connected to each other in-line one inlet and the other
as an outlet or the valve can be used by plugging one of the pressure ports.
YBG-03-P-※-10
184.5
54
33
C
7.5 35.5
Jum Nut
82
59.5
47.5
12.5
6
20 23
Surface Mounting
45.5 Locating Pin (O-Ring Furnished)
66.5 6 Dia.
Pressure
3 ssure
Vent Pre
Pressure
100
2
80
1
60
40 0 10 20 30 40 50 60 L/min.
20
Flow
0 10 20 30 40 50 60
Flow L/min.