2-Latest EIC-C-1002-0 (Pilot Operated Relief Valve)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

PRESSURE CONTROLS

EIC-C-1002-0
■ Pilot Operated Relief Valves
These valves protect the hydraulic system from excessive
pressure, and can be used to maintain constant pressure in
a hydraulic system.
Remote control and unloading are permitted by vent circuit.

Graphic Symbol

Vent Connection C

Pilot Operated Relief Valves


■ Specifications
Model Number Max. Operating Pres. Adj. Mass Kg.
Max. Flow
Threaded Sub-plate Pressure Range
L/min. BT type BG type
Connection Mounting Kgf/cm2 Kgf/cm2
- BG-03-※-32 100 - 4.7
BT-06-※-3280 BG-06-※-32 250 * ~ 250 200 5 5.6
- BG-10-※-32 400 - 8.7
* Refer to the Minimum adjustment Pressure characteristics on Page 5.

■ Model Number Designation


F- B T -03 P -V -32 ※
Type of Valve Plunger High Venting Design Design
Special Seal Series Number
Mounting Size Type Pres. Feature Number Standards
T:
F: Threaded 06 V: 32 80
Special Seals Connections For High
for Phosphate B: Venting
03 P: 32
Ester type Pilot Operated Pressure
G: Pull Type
Fluids. Relief Valves Feature
(omit if not Sub-plate 06
(Omit if not
32 ━
required) Mounting required)
10 32

Use high venting pressure type to reduce the response time from unload to onload.

Pilot Operated Relief Valves 1


PRESSURE CONTROLS

■ Attachment
Mounting Bolts
Valve Qty Bolt Kit
Socket Head Cap Screw
Model Number Nos. Ordering Code
BG-03 M12 x 70Lg., M12 x 95Lg. 2 each BK BG-03-10
BG-06 M16 x 60Lg., M16 x 80Lg. 2 each BK BG-06-10
BG-10 M20 x 70Lg., M20 x 90Lg. 2 each BK BG-10-10

■ Sub-Plate
Valve Sub-plate Piping Mass
Model Number Model Number Size Kg.
BGM-03-3080 3/8 BSP.F 2.4
BG-03
BGM-03X-3080 1/2 BSP.F 3.1
BGM-06-3080 3/4 BSP.F 4.7
BG-06
BGM-06X-3080 1 BSP.F 5.7
BGM-10-3080 1-1/4 BSP.F 8.4
BG-10
BGM-10X-3080 1-1/2 BSP.F 10.3
Sub-plates are available. Specify sub-plate model from the table above. When sub-plates are not used, the mounting
surface should have a good machined finish.

■ Instructions
If a remote control relief valve is used in the vent circuit, see page 1 in EIC-C-1001-0. In addition, if the
internal volume of the vent line is too large, chattering is likely to occur. Thus, as far as possible reduce
the inside Dia. and the length of the pipe.
To adjust the pressure, loosen the lock nut and turn the handle slowly clockwise for higher pressure or
anti-clockwise for lower pressures. One revolution of the handle makes about a 50 Kgf/cm2 pressure
change. After adjustments, do not forget to tighten the lock nut.
Pressure is limited by collars fitted. If a working pressure cannot be attained, remove some collars.
One collar is equivalent to 100 Kgf/cm2.
Piping of the Tank line should not be connected to any tank line of the other valves, but connected
directly to the tank.
With a small flow, the setting pressure may be unstable. Use models numbered 03 and 06 with a
flow rate 8 L/min. and model 10 with 15 L/min.
There are two threaded connection pressure ports. They can be connected each other in-line one
as inlet and the other as an outlet or the valve can be used by plugging one of the pressure ports.

2
Pilot Operated Relief Valves
PRESSURE CONTROLS

BT-06P- -3280 DIMENSIONS IN


MILLIMETRES

Lock Nut 14 Hex.


Two Collars Model Number “Q” Thd. “S” Thd. “T” Thd.

BT-06P- -3280 3/4 BSP.F 3/8 BSP.F 1/4 BSP. Tr
"A" SQ.

Pressure Adjustment Handle


(Selectable in other 3 positions) Model
A B C D E F
Number
BT-06 75 40 105 52 78 150.5

Model
45 Dia.

Vent Port 5 B C G H J K L N
Number
"S" Thd. Fully Extended
BT-06 68.5 62 36 52 90 45
C
D

Pilot Operated Relief Valves


H
F

Pressure Port P
J

"Q" Thd.
G

2 Places
T
Pressure Gauge N
E Connection L
"T" Thd.

M o u n ti n g S ur f ace
03 B G- 0 3 : I S O 6 2 6 4 AR - 0 6 - 2 - A
BG-06 P- 32 B G- 0 3 : I S O 6 2 6 4 A S - 0 8 - 2 - A
10 B G - 0 3 : I SO 6 2 6 4 A T - 1 0 - 2 - A

Model
H J K L
Number
Mounting Surface BG-03 14.1 41 82 117
(O-Ring Furnished) Lock Nut 14 Hex. BG-06 17 52 104 141
Two Collars BG-10 20.7 62 124 175
"A" SQ.

Model
N P Q S
Number
BG-03 77 22 13.5 21
Pressure Adjustment Handle BG-06 83.5 4.5 17.5 26
(Selectable in Other 2 Position) BG-10 110 6 124 175

In case of BG-03,
B C no spotface are
Fully Extended Vent Port made at those two
45 Dia.

holes.

Locating Pin
P

6 Dia.
G

Pressure Gauge
L

Connection
1 BSP.T Thd.
N

6 4

Pressure Port
D H "Q" Dia. x Thru.
E J "S" Dia. Spotface
F Tank Port K 4 Places

Pilot Operated Relief Valves 3


PRESSURE CONTROLS
03, 03X
Sub-Plate: BGM - 06, 06X-3080 DIMENSIONS IN
10, 10X MILLIMETRES

"b" Dia. x Thru.


"d" Dia. Spotface
4 Places A
B C
Y
"e" Thd. D E
4 Places 1 BSP.F Thd. Z
F 4
H

6.2 Dia.
N
L

S
U
K

V
G

P
J

T
Q

"a" Dia.
2 Places
"f" Thd.
7 Dia. x 10 Deep
2 Places

Model Numbers A B C D E F G H J K L N P Q
BGM-03 86 26
86 60 13 53.8 3.1 26.9 149 13 123 32 97 53.8
BGM-03X 95 21
BGM-06 106.5 27.2
108 78 15 70 4 35 180 15 150 51 121 66.7
BGM-06X 119 18
BGM-10 138.2 30.2
126 94 16 82.6 5.7 41.3 227 16 195 62 154 88.9
BGM-10X 158 17

Model Numbers S T U V X Y Z a b d
BGM-03 32
19 47.4 0 22 22 20 14.5 11 17.5
BGM-03X 40
BGM-06 40
37 55.5 23.8 33.4 11 25 23 13.5 21
BGM-06X 50
BGM-10 50
42 76.2 31.8 44.5 12.7 32 28 17.5 26
BGM-10X 63

Model Numbers “e” Thd. “f” Thd.


BGM-03 3/8 BSP.F
M12 Thd. x 20 Deep
BGM-03X 1/2 BSP.F
BGM-06 3/4 BSP.F
M16 Thd. x 25 Deep
BGM-06X 1 BSP.F
BGM-10 1 - 1/4 BSP.F
M20 Thd. x 28 Deep
BGM-10X 1 - 1/2 BSP.F

4
Pilot Operated Relief Valves
PRESSURE CONTROLS

■ Nominal Override Characteristics


BG-03 BG-06
Kgf/cm² Kgf/cm²
250 250
240
240 230
230

Pressure
Pressure

160 160
150 150
140 140
16 19
13 16
10 13

0 25 50 75 100 L/min. 0 50 100 150 200 L/min.


Flow Rate Flow Rate

Kgf/cm²
BG-10 C

Pilot Operated Relief Valves


250
240
230
Pressure

160
150
140
20
16
12

0 100 200 300 400 L/min.


Flow Rate

■ Min. Adj Pressure & Vent Pressure Vs Flow


BG-03 BG-06, BG-06
Vent Pressure Vent Pressure
Kgf/cm² Min. Adjustment Pressure Kgf/cm² Min. Adjustment Pressure
7 14

6 12
High Venting
Pressure

Pressure

5 10 Pressure Type

4 8
3 6
Low Venting
2 Pressure Type
4
High Venting Low Venting
1 Pressure Type 2 Pressure Type
0 0
0 25 50 75 100 L/min. 0 50 100 150 200 L/min.
Flow Rate Flow Rate

BG-10
Vent Pressure
Kgf/cm² Min. Adjustment Pressure
6
High Venting
4 Pressure Type
2
0
Pressure

8
6
4
Low Venting
2 Pressure Type
0
0 100 200 300 400 L/min.
Flow Rate

Pilot Operated Relief Valves 5


PRESSURE CONTROLS

■ Spare Parts List


List of Seals Quantity
Sl. Name of Part
No. Parts Number BG-03 BG-06 BG-10 BT-06
1 O-Ring SO-NA-P9 1 1 1 1
2 O-Ring SO-NB-P9 1 - 1 -
3 O-Ring SO-NB-P11 - 1 - -
4 O-Ring SO-NB-P18 2 - - -
5 O-Ring SO-NB-P28 - 2 - -
6 O-Ring SO-NB-P32 1 1 2 1
7 O-Ring SO-NB-P42 - - 1 -
Note: When ordering the seals, please specify the seal kit number from the table below.

List of Seal Kit


Model Numbers Seal Kit Numbers
BG-03 KS-BG-03-32
BG-06 KS-BG-06-32
BG-10 KS-BG-10-32
BT-06 KS-BT-06-32

6
Pilot Operated Relief Valves
PRESSURE CONTROLS

■ Solenoid Controlled Relief valves


These valves are a combination of relief valve and solenoid valve. Piping between the two is eliminated as the
solenoid valves is directly mounted on the relief valve and connected with the relief valve vent. Pump pressure may
be unloaded remotely by an electrical signal to the solenoid, or by connecting pilot relief valves to the solenoid valve
ports.

Solenoid Controlled
Relief valves
■ Specifications
Model Number Max. Operating Pres. Adj. Mass (Kg)
Max. Flow
Threaded Sub-Plate Pressure Range Double Single With Vent
L/min.
Connection Mounting Kgf/cm2 Kgf/cm2 Solenoid Solenoid Restrictor
BST-06-※-※-※-※-4680 - 200 7.4 6.8 7.8
- BSG-03-※-※-※-※-46 (Note) 100 7.1 6.5 7.5
250
- BSG-06-※-※-※-※-46 *~250 200 8.0 7.4 8.4
- BSG-10-※-※-※-※-46 400 11.3 10.7 11.7
Note: For Relief Valves, standard pilot operated relief valves are used.
* For minimum adjustment pressure and other characteristics, see page 5.

■ Model Number Designation


F- A- BS T -03 -V -2B3A -A120 -N -46 80
Type of
Special With Vent Series Type of Valve High Venting Vent Design Design
Coil Type electrical
Seals Restrictor Number Mounting Size Pres. Feature Type Number Standard
Connection

N:
T: AC: With Plug-in
F: V: *3
Threaded 06 2B3A *4 connector
Special *1 BS: *2 A120
A: Connection For High (DIN)
Seals for Solenoid 2B3B
Phosphate With Controlled Venting A240
2B2B 46 80
Ester Type Vent Relief Pressure
2B2 N1:
Fluids Restrictor Valves 03 Feature DC:
(Option) G: (Omit if not 3C2 With Plug-in
(Omit if not
Sub-Plate 06 required) 3C3 connector
required) D12,D24
Mounting with indicator
10 light (option)

*1 Models with vent restrictor are applicable only for the vent type 2B3A and 2B3B For details see page 9.
*2 Use high venting pressure types to reduce response time from unloading to onloading.
*3 For the details of the vent types, see the following page.
*4 The coil codes are the same as for solenoid directional valves DSG-01. See solenoid Rating on EIC-E-1001-0.

Solenoid Controlled Relief Valves 7


PRESSURE CONTROLS

■ Vent type
Solenoid Operated Operation
Vent Type
Graphic Symbols Directional Valve
Model Number SOL “a” SOL “b” Vent Connecting

"A"
b
OFF Connected to “A” port
2B3A DSG-01-2B3A --
ON Connected to tank (no-load)

"B"
b
OFF Connected to tank (no-load)
2B3B DSG-01-2B3B --
ON Connected to “B” port

"B"
b Closed State (relief valve
OFF
Setting pressure)
2B2B DSG-01-2B2B --
ON Connected to “B” port

"A" "B"
b
OFF Connected to “A” port
2B2 DSG-01-2B2 --
ON Connected to “B” port

"A" "B"
Closed State (relief valve
a b OFF OFF
Setting pressure)
3C2 DSG-01-3C2 ON OFF Connected to “A” port

OFF ON Connected to “B” port

"A" "B"
a b OFF OFF Connected to tank (no-load)

3C3 DSG-01-3C3 ON OFF Connected to “A” port

OFF ON Connected to “B” port

■ Spare Parts List


List of Seals
Sl. Name of Part Quantity
No. Parts Number BSG-03 BSG-06 BSG-10 BST-06
1 O-Ring SO-NB-P9 1 - 1 -
2 O-Ring SO-NB-P18 2 1 - -
3 O-Ring SO-NB-P32 1 1 - -
4 O-Ring SO-NB-P9 - 1 1 1
5 O-Ring SO-NB-P32 - - 4 1
6 O-Ring SO-NB-P42 - - 1 -
Note: When ordering the seals,
Please specify the seal kit number from the table below.

List of Seal Kits


Model Numbers Seal kit numbers
BSG-03 KS-BSG-03-4680
BSG-06 KS-BSG-06-4680
BSG-10 KS-BSG-10-4680
BST-06 KS-BST-06-4680

8
Solenoid Controlled Relief Valves
PRESSURE CONTROLS
■ Attachment
Mounting Bolts
Valve Bolt Kit
Socket Head Cap Screw Qty.
Model Number Ordering Code
BSG-03 M12 x 70Lg., M12 x 95Lg. 2 each BKBG - 03 - 30
BSG-06 M16 x 60Lg., M16 x 80Lg. 2 each BKBG - 06 30
BSG-10 M20 x 70Lg., M20 x 90Lg. 2 each BKBG - 10 - 30

■ Sub-Plate
Valve Sub-Plate Piping Mass
Model Number Model Number Size Kg.
BGM-03-3080 3/8 BSP.F 2.4
BSG-03
BGM-03X-3080 1/2 BSP.F 3.1
BGM-06-3080 3/4 BSP.F 4.7
BSG-06
BGM-06X-3080 1 BSP.F 5.7 C
BGM-10-3080 1-1/4 BSP.F 8.4
BSG-10
BGM-10X-3080 1-1/2 BSP.F 10.3

Solenoid Controlled
Sub-plates are available. Specify sub-plate model from the table above. When sub-plates are not

Relief valves
used, the mounting surface should have a good machined finish.
The sub-plates are those for pilot operated relief valves . For dimensions, refer page 4.

■ Option
With vent restrictor
The type with a vent restrictor valve, in vent types 2B3A and 2B3B added between relief valve and a
solenoid operated directional valve. It prevents shock to the main circuit by gradually lowering the venting
pressure in the shift from set pressure to unloading.
Unloading pressures are the same as without a vent restrictor.
A-BS ※-※-2B3A A-BS ※-※-2B3B
b b

■ Instructions
The remote control relief valve is used in the vent circuit, see page 1 in EIC-C-1001. In addition, if
the internal volume of the vent line is too large, chattering is likely to occur. Thus, as far as
possible reduce the inside diameter and the length of the pipe.
To adjust the pressure, loosen the lock nut and turn the handle slowly clockwise for higher pressure
or anti-clockwise for lower pressures. One revolution of the handle makes about a
50 Kgf/cm2 pressure change. After adjustments, do not forget to tighten the lock nut.
Pressure is limited by collars fitted. If a working pressure cannot be attained, remove some collars.
one collar is equivalent to 100 Kgf/cm2.
Piping of the tank line should not be connected to any tank line of the other valves, but connected
directly to the tank.
With a small flow, the setting pressure may be unstable. Use models numbered 03 and 06 with a
flow rate above 8 L/min. and model 10 with 15 L/min.
There are two threaded connection pressure ports in BST type. They can be connected each other
in-line; one as inlet and the other as an outlet or the valve can be used by plugging one of the
pressure ports.
Solenoid Controlled Relief Valves 9
PRESSURE CONTROLS

■ Models with Plug-in Connector


DIMENSIONS IN
03 MILLIMETRES
BSG-06- - - -N-4680
10
Cable Departure
210 Cable Applicable :
48.5 48.5 j Outside Dia. ..... 8-10mm
Conductor Area .....
Not Exceeding 1.5mm²

h
i
Sol a Sol b

Model
U
Number
BSG-03, -N- 85
4680 Design

U
BSG-06, -N- 102.5
Remote Only
BSG-10, -N- 110
Control Port
"B"
1 BSP.F Thd.
8

Remote Control Port


"A"
1 BSP.F Thd.
8
Vent Port Model Number i h j

Pressure Gauge BSG-※-※-※-A-N-4680 53 65 39


Pressure Port Connection (with AC solenoid)
BSG-※-※-※-D※-N-
1 BSP.Tr Thd.
4
64 76 39
(with DC solenoid)
Tank Port

■ Option-Models With Vent Restrictor


Plug-in Connector Type
03 2B3A
A-BSG-06- - -4680
10 2B3B

105

Plug-in Connector Type


Item
Sol b AC DC
Model d Q
Solenoid Solenoid
ff

Number
ee ff ee ff
A-BSG-03 115 77 245 180 256 191
d

ee

A-BSG-06 132.5 83.5 281 185 292 196.5


A-BSG-10 140 110 315 193 326 204
Q

10
Solenoid Controlled Relief Valves
PRESSURE CONTROLS

■ Models with Plug-in Connector


DIMENSIONS IN
MILLIMETRES
BST-06- - - -N-4680
Cable Departure
210 Cable Applicable :
Outside Dia. ..... 8-10mm
48.5 48.5 h Conductor Area .....
Not Exceeding 1.5mm²

Model Number T
※※※

f
107

e
BST-06- - - -N-

Model Number e f h
C
BST-※-※- 53 65 39

Solenoid Controlled
4680 Design Only (with AC solenoid)

T
BST-※-※-D-※-N-
Remote

Relief valves
Control Port "B" 64 76 39
1 BSP.F Thd.
8
(with DC solenoid)

Vent Port
3
8 BSP.Tr Thd.
Remote Control Port "A"
(Rear side) 1 BSP.F Thd.
8
Pressure Port
3
4 BSP.F Thd. Pressure Gauge Connection
2 Places 1 BSP.Tr Thd.
4

Tank Port 3 4 BSP.F Thd.

■ Option-Models With Vent Restrictor


Plug-in Connector Type

2B3A
A-BST-06- - - -4680
2B3B
105
zz

Plug-in Connector Type


yy
d

Item AC Solenoid DC Solenoid


d P
Model
yy zz yy zz
Number
A-BST-06 137 68.5 270.5 190 281.5 201
P

Solenoid Controlled Relief Valves 11


PRESSURE CONTROLS

■ Pilot Operated Relief Valve


These valves protect the hydraulic system from excessive pressure and can be used to maintain constant
Pressure in a hydraulic system. Vent circuit permits remote control and unloading.

Graphic Symbols

Vent Connection

■ Specifications
Max. Operating
Pres. Adj. Range Max. Flow Mass (Approx)
Model Numbers Pressure
Kgf/cm2 L/min. Kg.
Kgf/cm2

YBG-03-P- -10
250 (3555) 60 2.7
* ~ 250
YBG-03-P-※-10H50
* Refer to ̒ ̒ Minimum Adjustment Pressure ̓ ̓ charecteristics on page 5.

■ Model Number Designation


Y B G -03 -P -V -10
Type of Valve Plunger High Venting Pressure Design *
Series Number
Mounting Size Type Feature Number
V: For High Venting 10
B:Pilot Operated G:Sub-Plate P: Pull
Y:YIL 03 Pressure Feature
Relief Valve Mounting Type 10H50
(Omit if not required)
* Design number subject to change from 10 to 19, but installation dimensions remain as shown.
10-H50 - Change in Control Knob

■ Attachment
Mounting Bolts
Socket Head Cap
Model Number Qty. Bolt Kit Ordering Code
Screw
YBG-03-P- -10※ M12 x 55Lg. 4 BK-YBG-03-P- -10※

■ Sub-plate
Valve Model Sub-plate Model Mass (Approx)
Thread Size
Numbers Number Kg.

YBG-03-P- -10
BGM-03-3080 3/8 BSP.F 2.4
YBG-03-P-※-10H50
YBG-03-P-※-10
BGM-03-X-3080 3/8 BSP.F 2.4
YBG-03-P-※-10H50

Sub-plates are available. Specify sub-plate model from the table above. when sub-plates are not used, the mounting
surface should have a good machined finish.

Pilot Operated Relief Valve


12
PRESSURE CONTROLS

■ Instructions
If the internal volume of the vent line is too large, chattering is likely to occur. Thus, as far as possible reduce the
inside dia.and lenth of the pipe
To adjust the pressure, loosen the lock nut and turn the handle slowely clockwise for higher pressure or
anti-clockwise for lower pressure. One revolution of the handle makes about a 50Kg/cm² pressure change. After
adjustment, do not forget to tighten the lock nut.
Piping of the tank line should not be connect to tank line of the other valves, but connect directly to tank.
With a small flow, the setting pressure may be unstable.
There are two threaded connection pressure ports. They can be connected to each other in-line one inlet and the other
as an outlet or the valve can be used by plugging one of the pressure ports.

YBG-03-P-※-10
184.5
54
33
C
7.5 35.5

Pilot Operated Relief Valves


Pressure Adj. Knob
44
54
81

Jum Nut

13 Dia. x Thru. Lock Nut


20 Dia. Spotface x 12.5 Deep M16 x 1.5
4 Places
44.5 Dia.
79.5

82
59.5
47.5
12.5
6

20 23
Surface Mounting
45.5 Locating Pin (O-Ring Furnished)
66.5 6 Dia.

* For subplate details, see page 4.

Pilot Operated Relief Valve


13
PRESSURE CONTROLS

■ Nominal Override Characteristics ■ Min. Adj. Pressure & Vent


Kgf/cm² Pressure vs Flow
160
Kgf/cm²
5
140
stment. Pressure
Min. adju
4
120

Pressure
3 ssure
Vent Pre
Pressure

100
2
80
1
60

40 0 10 20 30 40 50 60 L/min.
20
Flow

0 10 20 30 40 50 60

Flow L/min.

■ Spare Parts List


List of Seals
Sl.
Name of Parts Parts Number Qty.
No.
1 O-Ring SO-NA-P4 1
2 O-Ring SO-NA-P9 2
3 O-Ring SO-NA-P14 2
4 O-Ring SO-NA-P22A 1
Note : When ordering the seals, please specify the seal kit number KS-YBG-03-10.

Pilot Operated Relief Valve